Search NASA⌕ Search

SEARCH · Search NASA

Results for “clinical development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Clinical Outcome Metrics for Optimization of Robust Training

Introduction: The emphasis of this research is on the Human Research Program (HRP) Exploration Medical Capability's (ExMC) "Risk of Unacceptable Health and Mission Outcomes Due to Limitations of In-Flight Medical Capabilities." Specifically, this project aims to contribute to the closure of gap ExMC 2.02: We do not know how the inclusion of a physician crew medical officer quantitatively impacts clinical outcomes during exploration missions. The experiments are specifically designed to address clinical outcome differences between physician and non-physician cohorts in both near-term and longer-term (mission impacting) outcomes. Methods: Medical simulations will systematically compare success of individual diagnostic and therapeutic procedure simulations performed by physician and non-physician crew medical officer (CMO) analogs using clearly defined short-term (individual procedure) outcome metrics. In the subsequent step of the project, the procedure simulation outcomes will be used as input to a modified version of the NASA Integrated Medical Model (IMM) to analyze the effect of the outcome (degree of success) of individual procedures (including successful, imperfectly performed, and failed procedures) on overall long-term clinical outcomes and the consequent mission impacts. The procedures to be simulated are endotracheal intubation, fundoscopic examination, kidney/urinary ultrasound, ultrasound-guided intravenous catheter insertion, and a differential diagnosis exercise. Multiple assessment techniques will be used, centered on medical procedure simulation studies occurring at 3, 6, and 12 months after initial training (as depicted in the following flow diagram of the experiment design). Discussion: Analysis of procedure outcomes in the physician and non-physician groups and their subsets (tested at different elapsed times post training) will allow the team to 1) define differences between physician and non-physician CMOs in terms of both procedure performance (pre-IMM analysis) and overall mitigation of the mission medical impact (IMM analysis); 2) refine the procedure outcome and clinical outcome metrics themselves; 3) refine or develop innovative medical training products and solutions to maximize CMO performance; and 4) validate the methods and products of this experiment for operational use in the planning, execution, and quality assurance of the CMO training process The team has finalized training protocols and developed a software training/testing tool in collaboration with Butler Graphics (Detroit, MI). In addition to the "hands on" medical procedure modules, the software includes a differential diagnosis exercise (limited clinical decision support tool) to evaluate the diagnostic skills of participants. Human subject testing will occur over the next year.

Ebert, D.↗

Cardio-Muscular Conditioner

In the mid-sixties, Gary Graham, a Boeing designer, developed a cardiovascular conditioner for a planned Air Force orbiting laboratory. After the project was cancelled, Graham participated in space station conditioning studies for the Skylab program. Twenty years later, he used this expertise to develop the Shuttle 2000-1, a physical therapy and athletic development conditioner, available through Contemporary Designs. The machine is used by football teams, sports clinics and medical rehabilitation centers. Cardiovascular fitness and muscular strength development are promoted through both kinetic and plyometric exercises.

Source record↗

Cutting Edge Technologies Presentation: An Overview of Developing Sensor Technology Directions and Possible Barriers to New Technology Implementation

The aerospace industry requires the development of a range of chemical sensor technologies for such applications as leak detection, emission monitoring, fuel leak detection, environmental monitoring, and fire detection. A range of chemical sensors are being developed based on micromachining and microfabrication technology to fabricate microsensors with minimal size, weight, and power consumption; and the use of nanomaterials and structures to develop sensors with improved stability combined with higher sensitivity, However, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. These technologies and technical approaches have direct relevance to breath monitoring for clinical applications. This presentation gives an overview of developing cutting-edge sensor technology and possible barriers to new technology implementation. This includes lessons learned from previous microsensor development, recent work in development of a breath monitoring system, and future directions in the implementation of cutting edge sensor technology.

Hunter, Gary W.↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Tissue fluid pressures - From basic research tools to clinical applications

This paper describes clinical applications of two basic research tools developed and refined in the past 20 years: the wick catheter (for measuring tissue fluid pressure) and the colloid osmometer (for measuring osmotic pressure). Applications of the osmometer include estimations of the reduced osmotic pressure of sickle-cell hemoglobin with deoxygenation, and of reduced swelling pressure of human nucleus pulposus with hydration or upon action of certain enzymes. Clinical uses of the wick-catheter technique include an improvement of diagnosis and treatment of acute and chronic compartment syndromes, the elucidation of the tissue pressure thresholds for neuromuscular dysfunction, and the development of a better tourniquet for orthopedics.

Hargens, Alan R.↗

Multiplexed Quantitative Proteomics in Prostate Cancer Biomarker Development

Prostate cancer (PCa) is the most common non-skin cancer among men in the United States. However, the widely used protein biomarker in PCa, prostate-specific antigen (PSA), while useful for initial detection, its use alone cannot detect aggressive PCa and can lead to overtreatment. This chapter provides an overview of PCa protein biomarker development. It reviews the state-of-the-art liquid chromatography-mass spectrometry-based proteomics technologies for PCa biomarker development, such as enhancing the detection sensitivity of low-abundance proteins through antibody-based or antibody-independent protein/peptide enrichment, enriching post-translational modifications such as glycosylation as well as information-rich extracellular vesicles, and increasing accuracy and throughput using advanced data acquisition methodologies. This chapter also summarizes recent PCa biomarker validation studies that applied those techniques in diverse specimen types, including cell lines, tissues, proximal fluids, urine, and blood, developing novel protein biomarkers for various clinical applications, including early detection and diagnosis, prognosis, and therapeutic intervention of PCa.

Prostate cancer, SRM, PRM, DIA, protein biomarker↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural basis for inhibition of coagulation factor VIII reveals a shared antigenic hotspot on the C1 domain

Hemophilia A arises from dysfunctional or deficient coagulation factor (F)VIII and leads to inefficient fibrin clot formation and uncontrolled bleeding events. The development of antibody inhibitors is a clinical complication in hemophilia A patients receiving FVIII replacement therapy. LE2E9 is an anti-C1 domain inhibitor previously isolated from a mild/moderate hemophilia A patient and disrupts FVIII interactions with von Willebrand factor and FIXa, though the intermolecular contacts that underpin LE2E9-mediated FVIII neutralization are undefined. To determine the structure of the complex between FVIII and LE2E9 and characterize its mechanism of inhibition. FVIII was bound to the antigen binding fragment (Fab) of NB2E9, a recombinant construct of LE2E9, and its structure was determined by cryogenic electron microscopy. Here, this report communicates the 3.46 Å structure of FVIII bound to NB2E9, with its epitope comprising FVIII residues S2040 to Y2043, K2065 to W2070, and R2150 to H2155. Structural analysis reveals that the LE2E9 epitope overlaps with portions of the epitope for 2A9, a murine-derived inhibitor, suggesting that these residues represent a shared antigenic region on the C1 domain between FVIII –/– mice and hemophilia A patients. Furthermore, the FVIII:NB2E9 structure elucidates the orientation of the LE2E9 glycan, illustrating how the glycan sterically blocks interactions between the FVIII C1 domain and the von Willebrand factor D' domain. A putative model of the FVIIIa:FIXa complex suggests potential clashing between the NB2E9 glycan and FIXa light chain. These results describe an antigenic “hotspot” on the FVIII C1 domain and provide a structural basis for engineering FVIII replacement therapeutics with reduced antigenicity.

60 APPLIED LIFE SCIENCES↗

A reproducible study design for the MIMIC-IV in-hospital mortality task

Open, tabular electronic health record (EHR) datasets such as MIMIC-III and MIMIC-IV have become critical resources for developing machine learning (ML) models addressing clinical prediction tasks, including hospital readmission, length of stay, and in-hospital mortality (IHM). While MIMIC-III has benefited from well-established preprocessing pipelines and standardized feature sets, MIMIC-IV remains comparatively challenging to work with because there are no standardized benchmarks to support reproducibility and comparability across studies. To address this limitation, we present a rigorously curated MIMIC-IV custom feature set optimized for IHM prediction, constructed through a reproducible preprocessing pipeline and feature selection strategy.

97 MATHEMATICS AND COMPUTING↗

The executive disruption model of tinnitus distress: Model validation in two independent datasets using factor score regression

This study presents the executive disruption model (EDM) of tinnitus distress and subsequently validates it statistically using two independent datasets (the Construction Dataset: n = 96 and the Validation Dataset: n = 200). The conceptual EDM was first operationalised as a structural causal model (construction phase). Then multiple regression was used to examine the effect of executive functioning on tinnitus-related distress (validation phase), adjusting for the additional contributions of hearing threshold and psychological distress. For both datasets, executive functioning negatively predicted tinnitus distress score by a similar amount (the Construction Dataset: β = −3.50, p = 0.13 and the Validation Dataset: β = −3.71, p = 0.02). Theoretical implications and applications of the EDM are subsequently discussed; these include the predictive nature of executive functioning in the development of distressing tinnitus, and the clinical utility of the EDM.

Clarke, Nathan A.↗

Training Ultrasound Image Classification Deep-Learning Algorithms for Pneumothorax Detection Using a Synthetic Tissue Phantom Apparatus

Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.

Boice, Emily N. (ORCID:0000000171802842)↗

Development and marketing of a prosthetic urinary control valve system

An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.

Tenney, J. B., Jr.↗

An Earthling to an Astronaut: Medical Challenges

Humans can travel safely into space in low Earth orbit (LEO) or to near-Earth objects if several medical, physiological, environmental, and human factors issues risks are mitigated. Research must be performed in order to set standards in these four areas, and current NASA standards are contained in the Space Flight Human System Standards volumes 1 and 2, and crew medical certification standards. These three sets of standards drive all of the clinical, biomedical research and environmental technology development for the NASA human space flight program. These standards also drive the identification of specific risks to crew health and safety, and we currently manage 65 human system risks within the human space flight program. Each risk has a specific program of research, technology development, and development of operational procedures to mitigate the risks. Some of the more important risks tat will be discussed in this talk include exposure to radiation, behavioral health due to confinement in a closed cabin, physiological changes such as loss of bone, muscle and exercise capability, reduction in immune system capability, environmental threats of maintaining an adequate atmosphere and water for drinking, avoidance of toxic or infectious material, protection of hearing, and human factors issues of equipment and task design. A nutritious and varied food supply must also be provided. All of these risks will be discussed and current strategies for mitigating these risks for long-duration human space flight. In mitigating these 65 human system risks, novel approaches to problem solving must be employed to find the most appropriate research and technology based applications. Some risk mitigations are developed internally to NASA while others are found through research grants, technology procurements, and more recently open innovation techniques to seek solutions from the global technical community. Examples and results will be presented from all of these approaches including the more recent use of prizes to stimulate innovation.

Davis, Jeffrey R.↗

Can We Trust Computational Modeling for Medical Applications?

Operations in extreme environments such as spaceflight pose human health risks that are currently not well understood and potentially unanticipated. In addition, there are limited clinical and research data to inform development and implementation of therapeutics for these unique health risks. In this light, NASA's Human Research Program (HRP) is leveraging biomedical computational models and simulations (M&S) to help inform, predict, assess and mitigate spaceflight health and performance risks, and enhance countermeasure development. To ensure that these M&S can be applied with confidence to the space environment, it is imperative to incorporate a rigorous verification, validation and credibility assessment (VV&C) processes to ensure that the computational tools are sufficiently reliable to answer questions within their intended use domain. In this presentation, we will discuss how NASA's Integrated Medical Model (IMM) and Digital Astronaut Project (DAP) have successfully adapted NASA's Standard for Models and Simulations, NASA-STD-7009 (7009) to achieve this goal. These VV&C methods are also being leveraged by organization such as the Food and Drug Administration (FDA), National Institute of Health (NIH) and the American Society of Mechanical Engineers (ASME) to establish new M&S VV&C standards and guidelines for healthcare applications. Similarly, we hope to provide some insight to the greater aerospace medicine community on how to develop and implement M&S with sufficient confidence to augment medical research and operations.

Mulugeta, Lealem↗

Credibility Assessment of Deterministic Computational Models and Simulations for Space Biomedical Research and Operations

Human missions beyond low earth orbit to destinations, such as to Mars and asteroids will expose astronauts to novel operational conditions that may pose health risks that are currently not well understood and perhaps unanticipated. In addition, there are limited clinical and research data to inform development and implementation of health risk countermeasures for these missions. Consequently, NASA's Digital Astronaut Project (DAP) is working to develop and implement computational models and simulations (M&S) to help predict and assess spaceflight health and performance risks, and enhance countermeasure development. In order to effectively accomplish these goals, the DAP evaluates its models and simulations via a rigorous verification, validation and credibility assessment process to ensure that the computational tools are sufficiently reliable to both inform research intended to mitigate potential risk as well as guide countermeasure development. In doing so, DAP works closely with end-users, such as space life science researchers, to establish appropriate M&S credibility thresholds. We will present and demonstrate the process the DAP uses to vet computational M&S for space biomedical analysis using real M&S examples. We will also provide recommendations on how the larger space biomedical community can employ these concepts to enhance the credibility of their M&S codes.

Mulugeta, Lealem↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 1

A small, portable, relatively inexpensive computer system was developed for on-line use in clinical or laboratory situations. The system features an integrated hardware-software package that permits use of all peripherals, such as analog-to-digital converter, oscilloscope, plotter, digital bus, with an interpreter constructed around the BASIC programming language. The system is conceptually similar to the LINC system developed in 1962, but is more compact and powerful due to intervening advances in integrated circuit technology. A description of the hardware of the system was given. A reference manual, user manual, and programming guides were also presented. Finally, a stereo display system for vectorcardiograms was described.

Mark, R. G.↗

Biomagnetic instrumentation and measurement

The instruments and techniques of biomagnetic measurement have progressed greatly in the past 15 years and are now of a quality appropriate to clinical applications. The paper reports on recent developments in the design and application of SQUID (Superconducting Quantum Interference Device) magnetometers to biomagnetic measurement. The discussion covers biomagnetic field levels, magnetocardiography, magnetic susceptibility plethysmography, ambient noise and sensor types, principles of operation of a SQUID magnetometer, and laboratory techniques. Of the many promising applications of noninvasive biomagnetic measurement, magnetocardiography is the most advanced and the most likely to find clinical application in the near future.

Iufer, E. J.↗

Medics: Medical Decision Support System for Long-Duration Space Exploration

The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.

Colombano, Silvano↗