Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography

A high-performance liquid chromatographic method was developed as an alternative to automated enzymatic analysis of uric acid in human urine preserved with thymol and/or thimerosal. Uric acid (tR = 10 min) and creatinine (tR = 5 min) were separated and quantified during isocratic elution (0.025 M acetate buffer, pH 4.5) from a mu Bondapak C18 column. The uric-acid peak was identified chemically by incubating urine samples with uricase. The thymol/thimerosal peak appeared at 31 min during the washing step and did not interfere with the analysis. We validated the high-performance liquid chromatographic method for linearity, precision and accuracy, and the results were found to be excellent.

NASA Discipline Regulatory Physiology↗

Interstellar Isomers: The Importance of Bonding Energy Differences

We present strong detections of methyl cyanide (CH3CN), vinyl cyanide (CH2CHCN), ethyl cyanide (CH3CH2CN) and cyanodiacetylene (HC4CN) molecules with the Green Bank Telescope (GBT) toward the Sgr B2(N) molecular cloud. Attempts to detect the corresponding isocyanide isomers were only successful in the case of methyl isocyanide (CH3NC) for its J(sub K) = 1(sub 0) - 0(sub 0) transition, which is the first interstellar report of this line. To determine the spatial distribution of CH3NC, we used archival Berkeley-Illinois-Maryland Association (BIMA) array data for the J(sub K) = 1(sub 0) - 0(sub 0) transitions but no emission was detected. From ab initio calculations, the bonding energy difference between the cyanide and isocyanide molecules is greater than 8500 per centimeter (greater than 12,000 K). Thus, cyanides are the more stable isomers and would likely be formed more preferentially over their isocyanide counterparts. That we detect CH3NC emission with a single antenna (Gaussian beamsize(omega(sub B))=1723 arcsec(sup 2)) but not with an interferometer (omega(sub b)=192 arcsec(sup 2)), strongly suggests that CH3NC has a widespread spatial distribution toward the Sgr B2(N) region. Other investigators have shown that CH3CN is present both in the LMH hot core of Sgr B2(N) and in the surrounding medium, while we have shown that CH3NC appears to be deficient in the LMH hot core. Thus, largescale, non-thermal processes in the surrounding medium may account for the conversion of CH3CN to CH3NC while the LMH hot core, which is dominated by thermal processes, does not produce a significant amount of CH3NC. Ice analog experiments by other investigators have shown that radiation bombardment of CH3CN can produce CH3NC, thus supporting our observations. We conclude that isomers separated by such large bonding energy differences are distributed in different interstellar environments, making the evaluation of column density ratios between such isomers irrelevant unless it can be independently shown that these species are co-spatial.

Remijan, Anthony J.↗

Optimizing GRACE/GRACE-FO Data and A priori Hydrological Knowledge for Improved Global Terrestial Water Storage Component Estimates

The comprehensive information of global terrestrial water storage (TWS) components (soil moisture, groundwater, snow, surface water) is essential for effective assessment of water resource availability, climate variation, and disaster mitigation measures. Observational data provided by the Gravity Recovery And Climate Experiment (GRACE) and GRACE Follow-On satellite missions offer global TWS variation (ΔTWS) in terms of an integrated water column. However, GRACE spatial resolution is relatively coarse (i.e., 3°), and the vertically integrated value cannot be separated into ΔTWS components directly. This study demonstrates the feasibility to estimate ΔTWS components at any desired spatial-vertical resolution by effectively maintaining the native resolution of the employed hydrological knowledge. It utilizes a least-squares with constraints (LSC) approach to rigorously incorporate GRACE and GRACE-FO data and a priori hydrological knowledge, with the aim to improve global ΔTWS components’ accuracy and spatial resolution. The 3°×3° GRACE mascon derived ΔTWS data is disaggregated into the 0.5°×0.5° anomalous soil moisture storage (ΔSMS), groundwater storage (ΔGWS), snow water equivalent (ΔSWE), and surface water storage (ΔSWS) based on the covariance information obtained from the Community Atmosphere Biosphere Land Exchange (CABLE) and the PCRaster Global Water Balance (PCR-GLOBWB) models. Evaluation with different ground measurements and satellite products between 2002 and 2019 exhibits significantly improved accuracy in all individual ΔTWS components. This improvement is of particular note in ΔGWS and ΔSWS, where the LSC approach increases the globally averaged correlation values by approximately 0.13 and 0.05, respectively. Reliable prior knowledge leads to a more accurate ΔTWS component estimate, and the use of ensemble-mean knowledge yields the best result.

GRACE↗

Airborne 2-Micron Double-Pulsed Integrated Path Differential Absorption Lidar for Column CO2 Measurement

Double-pulse 2-micron lasers have been demonstrated with energy as high as 600 millijouls and up to 10 Hz repetition rate. The two laser pulses are separated by 200 microseconds and can be tuned and locked separately. Applying double-pulse laser in DIAL system enhances the CO2 measurement capability by increasing the overlap of the sampled volume between the on-line and off-line. To avoid detection complicity, integrated path differential absorption (IPDA) lidar provides higher signal-to-noise ratio measurement compared to conventional range-resolved DIAL. Rather than weak atmospheric scattering returns, IPDA rely on the much stronger hard target returns that is best suited for airborne platforms. In addition, the IPDA technique measures the total integrated column content from the instrument to the hard target but with weighting that can be tuned by the transmitter. Therefore, the transmitter could be tuned to weight the column measurement to the surface for optimum CO2 interaction studies or up to the free troposphere for optimum transport studies. Currently, NASA LaRC is developing and integrating a double-Pulsed 2-micron direct detection IPDA lidar for CO2 column measurement from an airborne platform. The presentation will describe the development of the 2-micron IPDA lidar system and present the airborne measurement of column CO2 and will compare to in-situ measurement for various ground target of different reflectivity.

Singh, Upendra N.↗

The NII 2143 A emission in the dayglow

Observations of the N II 2143 A emission in the earth's dayglow were obtained by a rocket-borne spectrograph flown on Nov. 9, 1981, and Aug. 11, 1982. The ultraviolet spectra were analyzed using synthetic spectra to separate the contribution of the 2143 A emission from the overlapping nitric oxide gamma band. The 2143 A column emission rate profiles for both flights were quite similar with peak column emission intensities of approximately 500 Rayleighs at an altitude of 160 km. When the observed column emission rate profiles were compared with theoretical calculations, the production efficiency of this emission was found to be 0.10 + or - 0.04. The 2143 A emission varies by more than a factor of 3 over the solar cycle and therefore should be useful as an indicator of the solar EUV flux.

Cleary, D. D.↗

Plasma ion heating of an SO2 atmosphere on Io

The Jovian plasma-ion heating of any atmospheric gas over Io is shown to be important for determining the temperature structure and the location of the exobase and for limiting diffusive separation in Io's atmosphere. This is used, along with the plasma supply rate, to estimate an average column of gas over the trailing hemisphere of about 3 x 10 to the 16th SO2/sq cm with exobase at about 1.4 Io radii.

Johnson, R. E.↗

Damped Lyman-alpha absorption in Q0957+561A, B

A series of archival IUE low-dispersion spectral observations of the double quasar Q0957+561A, B are analyzed. The components of this gravitationally lensed quasar are separated by about 6 arcsec. Damped Ly-alpha absorption at redshift z(abs) = 1.3911 with neutral hydrogen column density N(H I) about 7 x 10 exp 19/sq cm is present in the spectra of both the A and B components. Using an accepted model by Young et al. for the gravitational lens, the damped Ly-alpha absorber is inferred to have a minimum size of about 0.5/h50 kpc. The standard interpretation is that a damped Ly-alpha absorber represents a galactic or protogalactic H I disk. In the context of this standard model, the absorption-line properties and evidence for Faraday rotation are discussed.

Turnshek, David A.↗

USML-1 Glovebox experiments

This report covers the development of and results from three experiments that were flown in the Materials Science Glovebox on USML-1: Marangoni convection in Closed Containers (MCCC), Double Float Zone (DFZ), and Fiber Pulling in Microgravity (FPM). The Glovebox provided a convenient, low cost method for doing simple 'try and see' experiments that could test new concepts or elucidate microgravity phenomena. Since the Glovebox provided essentially one (or possibly two levels of confinement, many of the stringent verification and test requirements on the experiment apparatus could be relaxed and a streamlined test and verification plan for flight qualification could be implemented. Furthermore, the experiments were contained in their own carrying cases whose external configurations could be identified early in the integration sequence for stowage considerations while delivery of the actual experiment apparatus could be postponed until only a few months before flight. This minimized the time fluids must be contained and reduced the possibility of corrosive reactions that could ruin the experiment. In many respects, this exercise was as much about developing a simpler, cheaper way of doing crew-assisted science as it was about the actual scientific accomplishments of the individual experiments. The Marangoni Convection in Closed Containers experiment was designed to study the effects of a void space in a simulated Bridgman crystal growth configuration and to determine if surface tension driven convective flows that may result from thermal gradients along any free surfaces could affect the solidification process. The Fiber Pulling in Microgravity experiment sought to separate the role of gravity drainage from capillarity effects in the break-up of slender cylindrical liquid columns. The Stability of a Double Float Zone experiment explored the feasibility of a quasi-containerless process in which a solidifying material is suspended by two liquid bridges of its own melt.

Naumann, Robert J.↗

Distributed Disdrometer and Rain Gauge Measurement Infrastructure Developed for GPM Ground Validation

Global Precipitation Mission (GPM)retrieval algorithm validation requires datasets characterizing the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (FOV;<10 km). Collection of this data provides a means to assess retrieval errors related to beam filling and algorithm PSD assumptions. Hence, GPM Ground Validation is developing a deployable network of precipitation gauges and disdrometers to provide fine-scale measurements of PSD and precipitation accumulation variability. These observations will be combined with dual-frequency, polarimetric, and profiling radar data in a bootstrapping fashion to extend validated PSD measurements to a large coverage domain. Accordingly, a total of 24 Parsivel disdrometers(PD), 5 3rd-generation 2D Video Disdrometers (2DVD), 70 tipping bucket rain gauges (TBRG),9 weighing gauges, 7 Hot-Plate precipitation sensors (HP), and 3 Micro Rain Radars (MRR) have been procured. In liquid precipitation the suite of TBRG, PD and 2DVD instruments will quantify a broad spectrum of rain rate and PSD variability at sub-kilometer scales. In the envisioned network configuration 5 2DVDs will act as reference points for 16 collocated PD and TBRG measurements. We find that PD measurements provide similar measures of the rain PSD as observed with collocated 2DVDs (e.g., D0, Nw) for rain rates less than 15 mm/hr. For heavier rain rates we will rely on 2DVDs for PSD information. For snowfall we will combine point-redundant observations of SWER distributed over three or more locations within a FOV. Each location will contain at least one fenced weighing gauge, one HP, two PDs, and a 2DVD. MRRs will also be located at each site to extend the measurement to the column. By collecting SWER measurements using different instrument types that employ different measurement techniques our objective is to separate measurement uncertainty from natural variability in SWER and PSD. As demonstrated using C3VP polarimetric radar, gauge, and 2DVD/PD datasets these measurements can be combined to bootstrap an area wide SWER estimate via constrained modification of density-diameter and radar reflectivity-snowfall relationships. These data will be combined with snowpack, airborne microphysics, radar, radiometer, and tropospheric sounding data to refine GPM snowfall retrievals. The gauge and disdrometer instruments are being developed to operate autonomously when necessary using solar power and wireless communications. These systems will be deployed in numerous field campaigns through 2016. Planned deployment of these systems include field campaigns in Finland (2010), Oklahoma (2011), Canada (2012) and North Carolina (2013). GPM will also deploy 20 pairs of TBRGs within a 25 km2 region along the Virginia coast under NASA NPOL radar coverage in order to quantify errors in point-area rainfall measurements.

Petersen, Walter A.↗

A Flexible Multibody Approach to Space Launch System Liftoff Pad Separation with Umbilical Disconnect

A flexible multibody dynamic framework is applied to the Space Launch System (SLS) liftoff Coupled Loads Analysis (CLA), enabling computational efficiencies and systematic inclusion of components and various nonlinearities. The objective of this work is to simulate the SLS liftoff transient pad separation event inclusive of umbilical disconnects. The vehicle stacking preloads and cryogenically induced preloads, due to the fueling of the Core Stage (CS), are integrated via specialized deformed coupling procedure to ensure full capture of the liftoff transient event. The Vehicle Stabilizer System (VSS) hydraulic struts are nonlinear and provide amplitude dependent damping, significantly contributing to the liftoff transient event. Ground Extensible Columns (EC) provide additional stiffness and preloads on the Mobile Launcher (ML), also significantly contributing to the liftoff transient. An advanced Henkel-Mar algorithm, with separation and re-contact, thus tracking the potential post separation re-contact between the booster aft skirt and ML, the umbilicals and vehicle, and ground EC separation. For this system level nonlinear dynamic simulation, the flexible multibody framework provides a systematic approach for the addition of component specific algorithms to enforce nonlinearities. This multibody framework is similar to an object-oriented programming language integrating classes of associated subroutines. As such, the complexities associated with the nonlinear CLA are greatly reduced, facilitating simplified bookkeeping as well as accelerating the execution of the nonlinear time-domain simulations.

Joel W Sills Jr.↗

Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry

The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.

Zondlo, Mark A.↗

Hormone Purification by Isoelectric Focusing

Various ground-based research approaches are being applied to a more definitive evaluation of the natures and degrees of electroosmosis effects on the separation capabilities of the Isoelectric Focusing (IEF) process. A primary instrumental system for this work involves rotationally stabilized, horizontal electrophoretic columns specially adapted for the IEF process. Representative adaptations include segmentation, baffles/screens, and surface coatings. Comparative performance and development testing are pursued against the type of column or cell established as an engineering model. Previously developed computer simulation capabilities are used to predict low-gravity behavior patterns and performance for IEF apparatus geometries of direct project interest. Three existing mathematical models plus potential new routines for particular aspects of simulating instrument fluid patterns with varied wall electroosmosis influences are being exercised.

Bier, M.↗

HPLC Characterization of Phenol-Formaldehyde Resole Resin Used in Fabrication of Shuttle Booster Nozzles

A reverse phase High Performance Liquid Chromatographic method was developed to rapidly fingerprint a phenol-formaldehyde resole resin similar to Durite(R) SC-1008. This resin is used in the fabrication of carbon-carbon composite materials from which Space Shuttle Solid Rocket Booster nozzles are manufactured. A knowledge of resin chemistry is essential to successful composite processing and performance. The results indicate that a high quality separation of over 35 peaks in 25 minutes were obtained using a 15 cm Phenomenex LUNA C8 bonded reverse phase column, a three-way water-acetonitrile-methanol nonlinear gradient, and LTV detection at 280 nm.

Young, Philip R.↗

The current development status of the Orbiting Carbon Observatory (OCO) instrument optical design

The status of the OCO instrument optical design is presented in this paper. The optical bench assembly comprises three cooled grating spectrometers coupled to an all-reflective telescope/relay system. Dichroic beam splitters are used to separate the light from a common telescope into the three spectral bands. The three bore sighted spectrometers allow the total column CO2 absorption path to be corrected for optical path and surface pressure uncertainties, aerosols, and water vapor. The design of the instrument is based on classic flight proven technologies.

global carb↗

Carbon and Oxygen Isotope Measurements of Ordinary Chondrite (OC) Meteorites from Antarctica Indicate Distinct Carbonate Species Using a Stepped Acid Extraction Procedure

The purpose of this study is to characterize the stable isotope values of terrestrial, secondary carbonate minerals from five Ordinary Chondrite (OC) meteorites collected in Antarctica. These samples were identified and requested from NASA based upon their size, alteration history, and collection proximity to known Martian meteorites. They are also assumed to be carbonate-free before falling to Earth. This research addresses two questions involving Mars carbonates: 1) characterize terrestrial, secondary carbonate isotope values to apply to Martian meteorites for isolating in-situ carbonates, and 2) increase understanding of carbonates formed in cold and arid environments with Antarctica as an analog for Mars. Two samples from each meteorite, each approximately 0.5 grams, were crushed and dissolved in pure phosphoric acid for 3 sequential reactions: a) R times 0 for 1 hour at 30 degrees Centigrade (fine calcite extraction), b) R times 1 for 18 hours at 30 degrees Centigrade (course calcite extraction), and c) R times 2 for 3 hours at 150 degrees Centigrade (siderite and/or magnesite extraction). CO (sub 2) was distilled by freezing with liquid nitrogen from each sample tube, then separated from organics and sulfides with a TRACE GC using a Restek HayeSep Q 80/100 6 foot 2 millimeter stainless column, and then analyzed on a Thermo MAT 253 Isotope Ratio Mass Spectrometer (IRMS) in Dual Inlet mode. This system was built at NASA/JSC over the past 3 years and proof-tested with known carbonate standards to develop procedures, assess yield, and quantify expected error bands. Two distinct species of carbonates are found: 1) calcite, and 2) non-calcite carbonate (future testing will attempt to differentiate siderite from magnesite). Preliminary results indicate the terrestrial carbonates are formed at approximately sigma (sup 13) C equal to plus 5 per mille, which is consistent with atmospheric CO (sub 2) sigma (sup 13) C equal to minus 7 per mille and fractionation of plus12 per mille based upon polar temperature of -20 degrees Centigrade. The oxygen values fractionate sigma (sup 18) O equal to minus 10-20 per mille lighter between the R times 0 and R times 1 reactions at 30 degrees Centigrade. The carbonate oxygen isotope measurements are consistently heavier than expected with meteoric water and temperatures from Antarctica, perhaps due to secondary carbonate formation during curation in Houston, TX.

Evans, Michael E.↗

Evaluation of Ionic Liquids for Closed Air Revitalization

This document is the final report resulting from the work conducted by undergraduate students at the University of South Alabama during the 2018/2019 academic year and was prepared by the undergraduate students. As NASA pushes the boundaries further into space, the current technologies within the various life support systems must be improved upon. One such improvement is needed to the current air revitalization systems, specifically sorbents that can capture CO2 more effectively from enclosed habitats. Ionic liquids (ILs) have been considered as absorbents for flue gas, but little research has been done to test the ability of ILs at ambient pressures and relatively low concentration of CO2. The experiment outlined below utilizes the task-specific ionic liquid, tetramethylammonium taurinate (TMN), in a commercial off the shelf absorption system to capture CO2. The CO2 stream is combined with nitrogen to produce an inlet gas concentration relevant to close air revitalization applications. At an inlet gas flow with a CO2 partial pressure of 3.8 torr the system was capable of removing just under 97% of the inlet CO2. The concentration of CO2 in the outlet stream, partial pressure 0.16 torr, was less than that of atmospheric air. The duty required to separate the absorbed gas from the ionic liquid as well to cool the ionic liquid to be reintroduced to the column were acquired utilizing laboratory cooling/heating baths. These results show that TMN may be an efficient candidate for consideration in closed air revitalization.

Duck, Gerald↗