Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Methods for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

Systems for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical processes for recovery and purification of high-purity uranium-234 from aged plutonium-238

This work describes a streamlined approach to the recovery and purification of 234 U from aged 238 Pu. Key modifications to conventional techniques are described that result in an efficient uranium and plutonium separation process that successfully produced tens of grams of ultrahigh purity 234 U at Oak Ridge National Laboratory. A new processing scheme was developed using an anion exchange column run in a cycling mode with HNO 3 media as the primary uranium purification process. This was followed with a uranyl peroxide precipitation step to purify and solidify the uranium before conversion to U 3 O 8 . Both the traditional uranyl peroxide precipitation method and a new cascade uranyl peroxide precipitation process were used for final purification of the 234 U.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Adaptive Pore Opening to Form Tailored Adsorption Sites in a Cooperatively Flexible Framework Enables Record Inverse Propane/Propylene Separation

A proposed low-energy alternative to the separation of alkanes from alkenes by energy-intensive cryogenic distillation is separation by porous adsorbents. Unfortunately, most adsorbents preferentially take up the desired, high-value major component alkene, requiring frequent regeneration. Adsorbents with inverse selectivity for the minor component alkane would enable the direct production of purified, reagent-grade alkene, greatly reducing global energy consumption. However, such materials are exceedingly rare, especially for propane/propylene separation. Here, we report that through adaptive and spontaneous pore size and shape adaptation to optimize an ensemble of weak noncovalent interactions, the structurally responsive metal-organic framework CdIF-13 (sod-Cd(benzimidazolate) 2 ) exhibits inverse selectivity for propane over propylene with record-setting separation performance under industrially relevant temperature, pressure, and mixture conditions. Powder synchrotron X-ray diffraction measurements combined with first-principles calculations yield atomic-scale insight and reveal the induced fit mechanism of adsorbate-specific pore adaptation and ensemble interactions between ligands and adsorbates. Dynamic column breakthrough measurements confirm that CdIF-13 displays selectivity under mixed-component conditions of varying ratios, with a record measured selectivity factor of α ≈ 3 at 95:5 propylene:propane at 298 K and 1 bar. When sequenced with a low-cost rigid adsorbent, we demonstrated the direct purification of propylene under ambient conditions. In conclusion, this combined atomic-level structural characterization and performance testing firmly establishes how cooperatively flexible materials can be capable of unprecedented separation factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of silver($\mathrm{I}$) ion reduction on the selectivity of olefins, paraffins, and aromatic compounds by gas chromatographic stationary phases consisting of silver($\mathrm{I}$) salts in ionic liquids

We report the olefin/paraffin selectivity offered by ionic liquid (IL) stationary phases can be enhanced through the addition of silver(I) ion, which is well-known to undergo selective complexation with unsaturated compounds. However, such stationary phases often suffer from the loss of chromatographic selectivity as silver(I) ion can be reduced to elemental silver. To maintain the separation performance of silver(I) ion/IL stationary phases, an understanding of factors and conditions that promote the reduction of silver(I) ion is needed. In this study, capillary gas chromatography columns featuring a stationary phase consisting of the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 - ]) IL impregnated with [Ag + ][NTf 2 - ] were examined to investigate the effects of temperature, hydrogen content in exposure gas stream, and time of heating/exposure events on olefin selectivity. Retention factors of representative analytes, such as C 6 olefins and paraffins as well as aromatic compounds, were measured after subjecting the columns to the aforementioned conditions, followed by an evaluation of selectivity factors over time. Selectivity factors of olefins and aromatic compounds were observed to decrease significantly when the stationary phases were heated to temperatures higher than 110°C as well as being subjected to mixed gas streams containing greater than 50 mol% of hydrogen. As constant column heating temperatures were applied under exposure gas mixtures containing hydrogen and nitrogen, a gradual decrease in analyte selectivity factors was observed under prolonged periods of time. However, application of a ternary gas mixture comprised of 25/50/25 mol% hydrogen/nitrogen/methane resulted in an increase in the 3-hexyne/cis-2-hexene selectivity when measured at 120°C for 60 h, due to a smaller decrease in the retention factor of 3-hexyne compared to cis-2-hexene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Scalable Array Design for III-V Compound Semiconductor-based Nonvolatile Memory (UltraRAM) with Separate Read-Write Paths

The dream of achieving a universal memory that can provide robust non-volatile memory states along with low-energy operation has been the key driving force of memory research. Despite dominating the memory market, conventional charge-based memories cannot satisfy these requirements. However, UltraRAM, an oxide-free charge-based memory cell, aims to achieve both of these requirements. This device achieves non-volatility (with an endurance of over 10 7 cycles and a retention of over 1000 years) along with switching at low-voltage (±2.3 V) utilizing a triple-barrier resonant tunneling (TBRT) structure made of InAs/AlSb. In this work, we propose an array design for UltraRAM-based memory devices. Our proposed memory array features separate read-write path and eliminates the possibility of accidentally switching the memory states stored in the array. Moreover, our design allows us to read all the cells in a column in one cycle without imposing any limit on the scalability. Besides, since the read operation in our proposed design is independent of the write mechanism, there is flexibility to optimize the read operation for memory and in-memory computing applications.

Alam, Shamiul↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Data for Yield from Iowa’s first commercial miscanthus fields: implications of spatial variability for productivity and sustainability beyond research plots

This dataset contains biomass yield measurements and associated vegetation index data collected from commercial Miscanthus × giganteus fields in eastern Iowa during the 2022–2023 growing seasons. The data support the analyses presented in the article: “Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots.” We collected 105 ground-truth biomass samples from four mature commercial fields (>4 years old) covering 92.81 ha. Samples were taken from 3 m² quadrats that were hand-harvested in alignment with commercial harvest timing. Stem biomass (excluding leaves) was weighed, moisture-corrected, and converted to dry-matter yield expressed in Mg DM ha⁻¹. Sampling locations were selected to capture spatial variability visible in aerial imagery and were recorded using RTK GPS. Each biomass observation was paired with vegetation indices derived from high-resolution PlanetScope satellite imagery (3 m resolution). Images were acquired throughout the growing season, and indices were calculated to evaluate their ability to predict end-of-season biomass yield. Statistical and machine learning approaches were used to identify key predictors, and a linear regression model based on end-of-July Green Normalized Difference Vegetation Index (GNDVI) was developed and evaluated. This repository includes the data used in that modeling workflow. Management practices, economic data, full imagery time series, and additional methodological details are described in the associated publication and are not included here. The dataset consists of three comma-separated value (CSV) files: 1. Combine_Groundtruth_Yield_VI_22_23.csv This file contains ground-truth biomass yield measurements and associated key vegetation index values collected during the 2022 and 2023 growing seasons. Rows: 105 observations Columns: Year — Year of observation (2022 or 2023) Field — Field location identifier Sample_number — Unique sample identifier GNDVI_End_Jul — Green Normalized Difference Vegetation Index calculated at end of July GNDVI_End_Aug — Green Normalized Difference Vegetation Index calculated at end of August NDRE_End_Aug — Normalized Difference Red Edge index calculated at end of August Biomass_Stem_Yield_MgDM/ha — Measured stem biomass yield (megagrams dry matter per hectare) 2. trainData_GNDVI.csv This file contains the subset of observations used to train the predictive relationship between July GNDVI and biomass yield. Rows: 76 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Stem_Yield_MgDM/ha — Observed stem biomass yield (Mg DM ha⁻¹) 3. testData_GNDVI.csv This file contains the test dataset used to evaluate model performance. Rows: 29 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Predicted_Yield_MgDM/ha — Model-predicted stem biomass yield (Mg DM ha⁻¹) Observed_Yield_MgDM/ha — Measured stem biomass yield (Mg DM ha⁻¹)

Potential yield, yield gap, in-field management, y↗

Hybrid-Lipid Bilayers Induce n -Alkyl-Chain Order in Reversed-Phase Chromatographic Surfaces, Impacting their Shape Selectivity for Aromatic Hydrocarbon Partitioning

Shape selectivity is important in reversed-phase liquid chromatographic separations, where stationary phases are capable of separating geometric isomers, thereby resolving solutes based on their three-dimensional structure or shape rather than other chemical differences. Numerous chromatographic studies have been carried out using n-alkyl-chain-modified columns to understand how molecular shape affects retention. For polycyclic aromatic hydrocarbons (PAHs), it was found that planar compounds were selectively retained over non-planar structures of comparable molecular weight on surfaces with longer n-alkyl chains, higher chain-density, or at lower temperatures, where selectivity likely arises with greater ordering of the n-alkyl chains. A limitation of these studies, however, is the small range of chain ordering that can be achieved and lack of a direct measure of the n-alkyl-chain order of the stationary phases. In this work, we employ a C 18 stationary phase modified with a monolayer of phospholipid as a means of significantly varying the n-alkyl chain order. These hybrid-supported lipid bilayers, which have previously been employed as membrane-like stationary phases for measuring lipophilicity, provide a unique approach to control n-alkyl chain ordering by varying the acyl chain length and degree of unsaturation of the phospholipid modifier. The degree of alkyl-chain order of the resulting modified surfaces is determined from the ratio of trans- versus gauche-conformers, measured in situ within individual porous particles by confocal Raman microscopy. This methodology was also used to assess the affinity of these surfaces for planar versus non-planar PAH molecules. The retention selectivity for the planar versus non-planar compounds, thus determined, was found to vary significantly and systematically with the degree of order of the acyl/alkyl chains in the hybrid-supported lipid bilayers. Furthermore, the investigation also demonstrates the utility of confocal Raman microscopy for interrogating the impact of solute partitioning on stationary-phase structure within porous chromatographic particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of chromatographic resins for high efficacy separation of radium from chemical analogues

The separation of Radium (Ra) from interfering chemical analogues is of major importance for both the accurate measurement of Ra-226 in environmental samples and the preparation of radium targets destined for medical isotope production. The adsorption behavior of Ra, Barium (Ba), and Strontium (Sr) was investigated on multiple crown-ether-based proprietary extraction chromatographic resins developed by TrisKem Int. Among these, the TK101 resin, characterized by a novel room-temperature ionic liquid (RTIL) dual extractant–solvent system, demonstrated enhanced affinity and selectivity, particularly at low acid concentrations, achieving a D w of 3477 ± 73 for Ra in 0.04 M HNO₃, whereas the maximum Ra D w obtained with the traditional Sr resin in 8 M HNO 3 was only 12.33 ± 0.4. In 0.04 M HNO 3 , a Ra distribution ratio (D w ) of 776 was achieved within 1 min, indicating rapid uptake kinetics. The adsorption capacities were estimated at 19.6 ± 0.1 mg/g for Ba and 12.0 ± 0.2 mg/g for Sr. However, competing alkali metals significantly reduced alkaline earth metal uptake, indicating that the TK101 resin is best suited for radium purification following a preconcentration step to minimize matrix effects in high salinity samples. Dynamic column studies confirmed the strong chromatographic performance of the TK101 resin, with no significant Ba or Sr breakthrough in the Ra fraction and a Ra recovery of 87 ± 2.8%. These results demonstrate the potential of the TK101 resin for selective radium separation in analytical and radiochemical applications.

and nuclear chemistry↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Near-Real-Time Material Tracking: Combining Vis–NIR Spectroscopy with Flow Sensing for Accurate Nd(III) Quantification

A fiber-optic visible–near-infrared (vis–NIR) absorption spectroscopy and flow sensor system has been developed for near-real-time tracking of Nd mass in the effluent stream from a column in a fume hood. The approach leverages two unique data streams and a partial least-squares regression (PLSR) model trained on vis–NIR absorption spectra of Nd(III) (0–1.5 M) in 1 M HNO 3 . In-line volumetric flow rate and vis–NIR spectra are measured in sequence after a chromatography column. The time stamps from each data stream are then synchronized, which allows integrated volumes to be combined with Nd(III) molarities predicted by a PLSR model to accurately calculate the Nd mass flowing through the column. This integrated measurement provides instantaneous mass flow and accumulates these data over time to obtain the total mass processed. The methodology developed in this study contributes critical technical infrastructure to improve monitoring capabilities to support chemical separations and the production of strategic materials and isotopes.

Irvine, Sawyer B. [Oak Ridge National Laboratory (↗

SPRUCE Sphagnum Growth and Photosynthesis Responses to Shading Treatments, 2021

This dataset reports growth, water content, nitrogen concentration, and photosynthesis of Sphagnum grown under shade cloth of different density in replicated plots adjacent to the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental study plots located in the S1-Bog. Data are reported for May to October 2021. Investigations were instigated from questions arising in the SPRUCE experiment where the Sphagnum-shrub-spruce/larch ecosystem is exposed to air and peat warming in combination with elevated atmospheric CO2. SPRUCE is located at the 8.1-ha S1 Bog forest site in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). Thirty plots (35 × 35 cm) were established in May, 2021, in three blocks on unused large plots on the S-1 bog. Data are reported for growth of Sphagnum angustifolium/fallax and S. divinum growing in plastic columns within the shade plots. Growth is reported as dry mass of new tissue measured when the columns were harvested in October 2021. Additional measurements in the final harvest datasetinclude Sphagnum water content, new stem length, mass per unit length, and nitrogen content. Stem extension was measured periodically during the summer and reported in a separate datasetas stem length. Photosynthesis of Sphagnum angustifolium/fallax samples from hollows under low and high shade was measured in the laboratory. Responses of sphagnum to shading are important for understanding the future of peatland systems under the encroachment of shrubs and other woody plant species. This dataset contains three data files in comma-separated values (.csv) format. Additional metadata are provided: three data dictionaries and a file-level metadata file in comma-separated values (.csv) format and a user guide in PDF (*.pdf) format.

carbon dioxide flux↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗