Search NASA⌕ Search

SEARCH · Search NASA

Results for “common references”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Advection algorithms for quantum neutrino moment transport

Neutrino transport in compact objects is an inherently challenging multidimensional problem. Here, this difficulty is compounded if one includes flavor transformation—an intrinsically quantum phenomenon requiring one to follow the coherence between flavors and thus necessitating the introduction of complex numbers. To reduce the computational burden, simulations of compact objects that include neutrino transport often make use of momentum-angle-integrated moments (the lowest order ones being commonly referred to as the energy density and flux) and these quantities can be generalized to include neutrino flavor, i.e., they become quantum moments. Numerous finite-volume approaches to solving the moment evolution equations for classical neutrino transport have been developed based on solving a Riemann problem at cell interfaces. In this paper we describe our generalization of a Riemann solver for quantum moments, specifically decomposing complex numbers in terms of a (signed) magnitude and phase instead of real and imaginary parts. We then test our new algorithm in numerous cases showing a neutrino fast flavor instability, varying from toy models with analytic solutions to snapshots from neutron star merger simulations. Compared to previous algorithms for neutrino transport with flavor mixing, we find uniformly smaller growth rates of the flavor transformation along with concomitantly larger length-scales, and that the results are a better match with the growth rates seen from multiangle codes.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Multiparticle Correlations in d + Au Collisions at 200, 62.4, 39, and 19.6 GeV and p + Au Collisions at 200 GeV and Implications for Collective Behavior

Recently, multiparticle-correlation measurements of relativistic p/d/ 3 He + Au, p + Pb, and even p + p collisions show surprising collective signatures. In this paper, we present beam-energy-scan measurements of two-, four-, and six-particle angular correlations in d + Au collisions at √ s NN = 200, 62.4, 39, and 19.6 GeV. We also present measurements of two- and four-particle angular correlations in p + Au collisions at √ s NN = 200 GeV. We find the four-particle cumulant to be real valued for d + Au collisions at all four energies. We also find that the four-particle cumulant in p + Au has the opposite sign as that in d + Au. Further, we find that the six-particle cumulant agrees with the four-particle cumulant in d + Au collisions at 200 GeV, indicating that nonflow effects are subdominant. Finally, these observations provide strong evidence that the correlations originate from the initial geometric configuration, which is then translated into the momentum distribution for all particles, commonly referred to as collectivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos 𝜈𝑒 observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the “gallium anomaly,” which could be interpreted as evidence for oscillations between 𝜈𝑒 and sterile neutrino (𝜈 𝑠 ) states. A 3.414-MCi 51 Cr 𝜈 𝑒 source was placed at the center of two nested Ga volumes and measurements were made of the production of 71 Ge through the charged current reaction, 71 Ga ⁢(𝜈 𝑒 ,𝑒 − ) ⁢71 Ge, at two average distances. The measured production rates for the inner and the outer targets, respectively, are [54.9$^{+2.5}_{−2.4}$⁢(stat) ± 1.4⁢(syst)] and [55.6$^{+2.7}_{−2.6}$⁢(stat) ± 1.4⁢(syst)] atoms of 71 Ge/𝑑. The ratio (𝑅) of the measured rate of 71 Ge production at each distance to the expected rate from the known cross section and experimental efficiencies are 𝑅 in = 0.79 ± 0.05 and 𝑅 out = 0.77 ± 0.05. The ratio of the outer to the inner result is 0.97 ± 0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20%–24% lower than expected, thus reaffirming the anomaly. Furthermore, these results are consistent with 𝜈 𝑒 → 𝜈 𝑠 oscillations with a relatively large Δ⁢𝑚 2 (>0.5 eV 2 ) and mixing sin 2 ⁡2⁢𝜃 (≈ 0.4).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quartz conditioning crystal for X-ray rocking curve topography

A large α-quartz crystal designed to condition the monochromatic beam at beamline 1-BM of the Advanced Photon Source is presented. The purpose of this crystal was to provide a precise match to the Bragg angle of quartz crystals that are commonly used to make analyzers for plasma diagnostics. In order to characterize these analyzers, area detectors need to be positioned at distances from the analyzer at upwards of 1000 mm. As a result of this precise matching, a Bragg-reflected beam from such an analyzer is precisely parallel to the beam incident on the conditioning crystal. This situation alleviates the need to adjust the position of the area detector as the distance between the analyzer and the area detector is varied. That is, there is no need to account for vertical displacement of the diffracted-beam image as a function of this distance. Additionally, verification that the analyzer is set to the correct Bragg reflection is obtained by scanning this distance, because only for a spurious reflection will there be a vertical displacement. This is a very useful check. To commission the conditioning crystal, diffraction from a high-quality flat quartz crystal was mapped using a CCD. Bragg diffraction from the 40$\bar{40}$ reflection at 8.5 keV was studied over an area of 23 × 31 mm. The theoretical Darwin width of the flat sample in this case was 4.7 µrad. An FWHM value near 6 µrad was measured over almost the entire mapped area. These data demonstrate that the resolution function for this four-crystal arrangement is ~4 µrad. Data are also presented for a 0.1 mm-thick α-quartz wafer pressed into a concave form, having a nominal radius of 500 mm and intended for use as an analyzer. Because analyzers are bent crystals, diffraction occurs in narrow bands. When a multiple exposure is made as a function of rocking angle a striped pattern is obtained, which is commonly referred to as a zebra-stripe pattern. A series of zebra stripes from the 30$\bar{33}$ Bragg reflection of the bent wafer over its 25 mm-diameter area were recorded on a CCD. The zebra-stripe pattern was analyzed to show a uniform bending to a radius of 497.0 ± 0.3 mm, in support of the nominal value. An r.m.s. slope error of 7 µrad was also obtained from this analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical and Chemical Sensing With Electronic Skin

This paper reviews current progress on flexible and stretchable transistors and sensors for the next-generation multiplex electronics (commonly referred to as 'electronics skin' or 'e-skin') that is capable of simultaneous detection of multiple information from a variety of surfaces including human skin. Flexible chemical sensors for sweat analysis as well as physical sensors for detecting tactile force, bending, and temperature will be discussed, with emphasis on materials, detection mechanisms, and device demonstration to realize multiplex human-interactive devices. System integration enabling the real-time monitoring of health conditions is also demonstrated as a proof of concept. Finally, perspectives on e-skin for moving toward realizing practical wearable electronics in the market are discussed. This paper targets the translation of the nano- and flexible technologies from academic innovations to industrial practical applications with high-impact breakthroughs.

42 ENGINEERING↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

General Failure Modes and Effects Analysis for Accelerator and Detector Magnet Design at JLab

The aim of this article is to develop a risk management procedure, which could be applied to the magnet design process, for both superconducting and normal magnets at the Jefferson Laboratory (JLab). This procedure allowed us to identify the key risks at each of the critical phases of design and propose procedures, tests, and checks to mitigate each risk. In this article, we present a qualitative and quantitative risk management procedure commonly referred to a “failure modes and effects analysis.” As part of this procedure, we calculated a risk priority number (RPN) for each activity of the process, identified the most critical activities and proposed mitigation activities, which in turn resulted in a revised RPN. Additionally, another benefit of this procedure was the identification of appropriate “control and hold” points within the design process, which allowed one to review and approve a particular outcome before proceeding to the next sequential activity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Genome‐enabled exploration of microbial ecology and evolution in the sea: a rising tide lifts all boats

Summary As a young bacteriologist just launching my career during the early days of the ‘microbial revolution’ in the 1980s, I was fortunate to participate in some early discoveries, and collaborate in the development of cross‐disciplinary methods now commonly referred to as "metagenomics". My early scientific career focused on applying phylogenetic and genomic approaches to characterize ‘wild’ bacteria, archaea and viruses in their natural habitats, with an emphasis on marine systems. These central interests have not changed very much for me over the past three decades, but knowledge, methodological advances and new theoretical perspectives about the microbial world certainly have. In this invited ‘How we did it’ perspective, I trace some of the trajectories of my lab's collective efforts over the years, including phylogenetic surveys of microbial assemblages in marine plankton and sediments, development of microbial community gene‐ and genome‐enabled surveys, and application of genome‐guided, cultivation‐independent functional characterization of novel enzymes, pathways and their relationships to in situ biogeochemistry. Throughout this short review, I attempt to acknowledge, all the mentors, students, postdocs and collaborators who enabled this research. Inevitably, a brief autobiographical review like this cannot be fully comprehensive, so sincere apologies to any of my great colleagues who are not explicitly mentioned herein. I salute you all as well!

59 BASIC BIOLOGICAL SCIENCES↗

Local Equilibrium and Retardation Revisited

We present that in modeling solute transport with mobile-immobile mass transfer (MIMT), it is common to use an advection-dispersion equation (ADE) with a retardation factor, or retarded ADE. This is commonly referred to as making the local equilibrium assumption (LEA). Assuming local equilibrium, Eulerian textbook treatments derive the retarded ADE, ostensibly exactly. However, other authors have presented rigorous mathematical derivations of the dispersive effect of MIMT, applicable even in the case of arbitrarily fast mass transfer. We resolve the apparent contradiction between these seemingly exact derivations by adopting a Lagrangian point of view. We show that local equilibrium constrains the expected time immobile, whereas the retarded ADE actually embeds a stronger, nonphysical, constraint: that all particles spend the same amount of every time increment immobile. Eulerian derivations of the retarded ADE thus silently commit the gambler's fallacy, leading them to ignore dispersion due to mass transfer that is correctly modeled by other approaches. We then present a particle tracking simulation illustrating how poor an approximation the retarded ADE may be, even when mobile and immobile plumes are continually near local equilibrium. Finally, we note that classic “LEA” (actually, retarded ADE validity) criteria test for insignificance of MIMT-driven dispersion relative to hydrodynamic dispersion, rather than for local equilibrium.

58 GEOSCIENCES↗

Scaling Effects in Perovskite Ferroelectrics: Fundamental Limits and Process-Structure-Property Relations

Ferroelectric materials are well-suited for a variety of applications because they can offer a combination of high performance and scaled integration. Examples of note include piezoelectrics to transform between electrical and mechanical energies, capacitors used to store charge, electro-optic devices, and non-volatile memory storage. Accordingly, they are widely used as sensors, actuators, energy storage, and memory components, ultrasonic devices, and in consumer electronics products. Because these functional properties arise from a non-centrosymmetric crystal structure with spontaneous strain and a permanent electric dipole, the properties depend upon physical and electrical boundary conditions, and consequently, physical dimension. The change of properties with decreasing physical dimension is commonly referred to as a size effect. In thin films, size effects are widely observed, while in bulk ceramics, changes in properties from the values of large-grained specimens is most notable in samples with grain sizes below several microns. It is important to note that ferroelectricity typically persists to length scales of about 10 nm, but below this point is often absent. Despite the stability of ferroelectricity for dimensions greater than ~10 nm, the dielectric and piezoelectric coefficients of scaled ferroelectrics are suppressed relative to their bulk counterparts, in some cases by changes up to 80%. The loss of extrinsic contributions (domain and phase boundary motion) to the electromechanical response accounts for much of this suppression. In this article the current understanding of the underlying mechanisms for this behavior in perovskite ferroelectrics are reviewed. We focus on the intrinsic limits of ferroelectric response, the roles of electrical and mechanical boundary conditions, grain size and thickness effects, and extraneous effects related to processing. Ultimately, in many cases, multiple mechanisms combine to produce the observed scaling effects.

36 MATERIALS SCIENCE↗

All in the timing: epigenetic control of greening

During germination, the emerging seedling relies on a limited supply of energy and nutrients stored within itself and the seed. This often occurs underground in darkness where seedlings undergo skotomorphogenesis, characterized by hypocotyl elongation, reduced root growth, and small closed cotyledons forming an apical hook to protect the shoot apical meristem as the seedling grows though the soil towards sunlight. Such long and pale dark-grown seedlings are commonly referred to as etiolated (from the French étiolier (to make pale)). However, a seedling must eventually find sunlight and make an irreversible shift to photoautotrophic growth (photomorphogenesis or de-etiolation). This leads to a dramatic change in physiology, including reduced hypocotyl elongation, increased root growth, expansion and unfolding of the cotyledons, and the biogenesis of photosynthetic plastids (i.e. chloroplasts). Furthermore, this shift is accompanied by a massive change in gene expression, with about one-third of genes being reprogrammed. A large amount of the transcriptional response is regulated by the plant photoreceptors (phytochromes and cryptochromes) that activate transcriptional networks. Furthermore, this involves the rapid degradation of PHYTOCHROME INTERACTING FACTORS (PIFs), which are basic helix-loop-helix domain-containing transcription factors that repress photomorphogenesis in the dark.

59 BASIC BIOLOGICAL SCIENCES↗

Industry 4.0 and Intelligent Manufacturing Processes: A Review of Modern Sensing Technologies

Digital Manufacturing technologies have quickly become ubiquitous in the manufacturing industry. The transformation commonly referred to as the fourth industrial revolution, or Industry 4.0, has ushered in a wide range of communication technologies, connection mechanisms, and data analysis capabilities. These technologies provide powerful tools to create a more lean, profitable, and data-driven manufacturing processes. In this paper, we review modern communication technologies and connection architectures for Digital Manufacturing and Industry 4.0 applications. An introduction to Cyber-Physical Systems and a review of digital manufacturing trends is followed by an overview of data acquisition methods for manufacturing processes. Numerous communication protocols are presented and discussed for connecting disparate machines and processes. Flexible data architectures are discussed and examples of machine monitoring implementations are provided. Finally, select implementations of these communication protocols and architectures are surveyed with recommendations for future architecture implementations.

42 ENGINEERING↗

Production of an impermeable composite of irradiated graphite and glass by hot isostatic pressing as a long term leach resistant waste form

Around 250,000 tons of irradiated graphite (i-graphite) exists worldwide and can be considered as a current waste or future waste stream. The largest national i-graphite inventory is located in UK (∼ 100,000 tons) with significant quantities also in Russia and France [5]. Most of the i-graphite remains in the cores of shutdown nuclear reactors including the MAGNOX type in UK and the UNGG in France. Whilst there are still operational power reactors with graphite cores, such as the Russian RBMKs and the AGRs in UK, all of them will reach their end of life during the next two decades. The most common reference waste management option of i-graphite is a wet or dry retrieval of the graphite blocks from the reactor core and the grouting of these blocks in a container without further conditioning. This produces large waste package volumes because the encapsulation capacity of the grout is limited and large cavities in the graphite blocks could reduce the packing densities. Packing densities from 0.5 to 1 tons per cubic meter have been assumed for grouting solutions. Furthermore the grout is permeable. This could over time allow the penetration of aqueous phases into the waste block and a potential dissolution and release of radionuclides. As a result particularly highly soluble radionuclides may not be retained by the grout. Vitrification could present an alternative, however a similar waste package volume increase may be expected since the encapsulation capacity of glass is potentially similar to or worse than that of grout. FNAG has developed a process for the production of a graphite-glass composite material called Impermeable Graphite Matrix (IGM) [3]. This process is also applicable to irradiated graphite which allows the manufacturing of an impermeable material without volume increase. Crushed i-graphite is mixed with 20 vol.% of glass and then pressed under vacuum at an elevated temperature in an axial hot vacuum press (HVP). The obtained product has zero or negligible porosity and a water impermeable structure. Structural analysis shows that the glass in the composite has replaced the pores in the graphite structure. The typical pore volume of a graphite material is in the range of 20 vol.%. Therefore no volume increase will occur in comparison with the former graphite material. This IGM material will allow the encapsulation of graphite with package densities larger than 1.5 ton per cubic meter. Therefore a huge volume saving can be achieved by such an alternative encapsulation method. Disposal performance is also enhanced since little or no leaching of radionuclides is observed due to the impermeability of the material NNL and FNAG have proved that IGM can be produced by hot isostatic pressing (HIP) which has several advantages for radioactive materials over the HVP process. - The sealed HIP container avoids the release of any radionuclides. - The outside of the waste package is not contaminated. - The HIP process time is shorter than the HVP process time. The isostatic press avoids anisotropic density distributions. - Simple filling of the HIP container has advantages over the filling of an axial die. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Verification of ABS Concrete Design Methodology Applied to the Design of the First Commercial Scale Floating Offshore Wind Turbine in the United States

The abundance of consistent high strength winds off the world’s coastlines and the close proximity to dense population centers has led to development of innovative marine structures to support wind turbines to capture this energy resource. Off the US coast, 60% of the offshore wind lies in deep water (greater than 60m) where the development of Floating Offshore Wind Turbine (FOWT) hull technology will likely be required in lieu of fixed bottom technology such as jacket structures. The United States National Renewable Energy Laboratory (NREL) and the offshore wind community commonly refer to 60m as the transition point between fixed bottom structures and floating structures due to economic reasons. Floating wind turbines deployed in the harsh offshore marine environment require the use of materials that are cost-effective, corrosion resistant, require little maintenance and are highly durable. This has led the University of Maine to develop a concrete hull technology called VolturnUS for full-scale 6MW FOWTs. In this work, experimental testing was conducted to verify the performance of the concrete under operational, serviceability, and extreme loading conditions as required by the American Bureau of Shipping Guide for Building and Classing Floating Offshore Wind Turbines. Here, the testing included structural testing sub-components of the hull and served as experimental verification of American Bureau of Shipping (ABS) concrete design methodology which is currently approved and being used to design the first commercial scale FOWTs in the United States. Two 6MW wind turbines supported on VolturnUS concrete hulls will be used for the New England Aqua Ventus I project. The project is planned to be deployed and connected to the grid by 2019 in the Northeast U.S. and is funded by the US Department of Energy.

Concretes↗

Off-label use of medical products in radiation therapy: Summary of the Report of AAPM Task Group No. 121

Medical products (devices, drugs, or biologics) contain information in their labeling regarding the manner in which the manufacturer has determined that the products can be used in a safe and effective manner. The Food and Drug Administration (FDA) approves medical products for use for these specific indications which are part of the medical product's labeling. When medical products are used in a manner not specified in the labeling, it is commonly referred to as off-label use. The practice of medicine allows for this off-label use to treat individual patients, but the ethical and legal implications for such unapproved use can be confusing. Although the responsibility and, ultimately, the liability for off-label use often rests with the prescribing physician, medical physicists and others are also responsible for the safe and proper use of the medical products. When these products are used for purposes other than which they were approved, it is important for medical physicists to understand their responsibilities. In the United States, medical products can only be marketed if officially cleared, approved, or licensed by the FDA; they can be used if they are not subject to or specifically exempt from FDA regulations, or if they are being used in research with the appropriate regulatory safeguards. Medical devices are either cleared or approved by FDA's Center for Devices and Radiological Health. Drugs are approved by FDA's Center for Drug Evaluation and Research, and biological products such as vaccines or blood are licensed under a biologics license agreement by FDA's Center for Biologics Evaluation and Research. For the purpose of this report, the process by which the FDA eventually clears, approves, or licenses such products for marketing in the United States will be referred to as approval. This report summarizes the various ways medical products, primarily medical devices, can legally be brought to market in the United States, and includes a discussion of the approval process, along with manufacturers' responsibilities, labeling, marketing and promotion, and off-label use. This is an educational and descriptive report and does not contain prescriptive recommendations. This report addresses the role of the medical physicist in clinical situations involving off-label use. Case studies in radiation therapy are presented. Any mention of commercial products is for identification only; it does not imply recommendations or endorsements of any of the authors or the AAPM. The full report, containing extensive background on off-label use with several appendices, is available on the AAPM website (http://www.aapm.org/pubs/reports/).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRA-13: Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Based On Principle Component Analysis

Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process and then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-05: Fast Volumetric MRI On An MRI-Linac Enables On-Line QA On Dose Deposition in the Patient

Purpose: The introduction of the MRI-linac in radiotherapy brings MRI-guided treatment with daily plan adaptions within reach. This paradigm demands on-line QA. With its ability to perform continuous volumetric imaging in an outstanding soft-tissue contrast, the MRI- linac promises to elucidate the dose deposition process during a treatment session. Here we study for a prostate case how dynamic MRI combined with linac machine parameters and a fast dose-engine can be used for on-line dose accumulation. Methods: Prostate imaging was performed in healthy volunteer on a 1.5T MR-scanner (Philips, Best, NL) according to a clinical MR-sim protocol, followed by 10min of dynamic imaging (FLASH, 4s/volume, FOV 40×40×12cm{sup 3}, voxels 3×3×3mm{sup 3}, TR/TE/α=3.5ms/1.7ms/5°). An experienced radiation oncologist made delineations, considering the prostate CTV. Planning was performed on a two-compartment pseudoCT (air/water density) according to clinical constraints (77Gy in PTV) using a Monte-Carlo (MC) based TPS that accounts for magnetic fields. Delivery of one fraction (2.2Gy) was simulated on an emulator for the Axesse linac (Elekta, Stockholm, SE). Machine parameters (MLC settings, gantry angle, dose rate, etc.) were recorded at 25Hz. These were re-grouped per dynamic volume and fed into the MC-engine to calculate a dose delivered for each of the dynamics. Deformations derived from non-rigid registration of each dynamic against the first allowed dose accumulation on a common reference grid. Results: The DVH parameters on the PTV compared to the optimized plan showed little changes. Local deformations however resulted in local deviations, primarily around the air/rectum interface. This clearly indicates the potential of intra-fraction adaptations based on the accumulated dose. Application in each fraction helps to track the influence of plan adaptations to the eventual dose distribution. Calculation times were about twice the delivery time. Conclusion: The current Result paves the way to perform on-line treatment delivery QA on the MRI-linac in the near future.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-04: Cross Validation of Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Using Principle Component Analysis

Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.

60 APPLIED LIFE SCIENCES↗