Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressive sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SWinzip v. 2.0

SWinzip is a Matlab and C++ library for scientific lossy data compression and reconstruction using compressed sensing and tree-wavelets transforms. These methods are known for their large compression and usefulness in data analytics such as features extraction. Compressed sensing and wavelets methods rely heavily on sparse and dense linear algebra operations implemented through the Boost codes in our library. SWinzip accommodates data represented on both regular grids (e.g. image data) and point-clouds (e.g. unstructured meshes). In SWinzip v2.0, there is more focus on wavelet compression and the following features are added: - The matrix-free (direct) wavelet transform is implemented in both C++ and Matlab. A threshold-based compression can now be used. Examples for distributed compression are also added. - Python implementation of Alpert wavelet transforms - Field data comparison using wavelets in Matlab with global and local metrics

Solloum, Maher↗

SWinzip v. 1.0

SWinzip is a Matlab and C++ library for scientific lossy data compression and reconstruction using compressed sensing and tree-wavelets transforms. These methods are known for their large compression and usefulness in data analytics such as features extraction. Compressed sensing and wavelets methods rely heavily on sparse and dense linear algebra operations implemented through the Boost codes in our library. SWinzip accommodates data represented on both regular grids (e.g. image data) and point-clouds (e.g. unstructured meshes).

Salloum, Maher↗

Constructing Surrogate Models of Complex Systems with Enhanced Sparsity: Quantifying the influence of conformational uncertainty in biomolecular solvation

Biomolecules exhibit conformational fluctuations near equilibrium states, inducing uncertainty in various biological properties in a dynamic way. We have developed a general method to quantify the uncertainty of target properties induced by conformational fluctuations. Using a generalized polynomial chaos (gPC) expansion, we construct a surrogate model of the target property with respect to varying conformational states. We also propose a method to increase the sparsity of the gPC expansion by defining a set of conformational “active space” random variables. With the increased sparsity, we employ the compressive sensing method to accurately construct the surrogate model. We demonstrate the performance of the surrogate model by evaluating fluctuation-induced uncertainty in solvent-accessible surface area for the bovine trypsin inhibitor protein system and show that the new approach offers more accurate statistical information than standard Monte Carlo approaches. Further more, the constructed surrogate model also enables us to directly evaluate the target property under various conformational states, yielding a more accurate response surface than standard sparse grid collocation methods. In particular, the new method provides higher accuracy in high-dimensional systems, such as biomolecules, where sparse grid performance is limited by the accuracy of the computed quantity of interest. Our new framework is generalizable and can be used to investigate the uncertainty of a wide variety of target properties in biomolecular systems.

coarse graining↗

Efficient compressive and Bayesian characterization of biphoton frequency spectra

Frequency-bin qudits constitute a promising tool for quantum information processing, but their high dimensionality can make for tedious characterization measurements. Here we introduce and compare compressive sensing and Bayesian mean estimation for recovering the spectral correlations of entangled photon pairs. Using a conventional compressive sensing algorithm, we reconstruct joint spectra with up to a 26-fold reduction in measurement time compared to the equivalent raster scan. Applying a custom Bayesian model to the same data, we then additionally realize reliable and consistent quantification of uncertainty. Finally, these efficient methods of biphoton characterization should advance our ability to use the high degree of parallelism and complexity afforded by frequency-bin encoding.

42 ENGINEERING↗

Signal Recovery and System Calibration from Multiple Compressive Poisson Measurements

The measurement matrix employed in compressive sensing typically cannot be known precisely a priori and must be estimated via calibration. One may take multiple compressive measurements, from which the measurement matrix and underlying signals may be estimated jointly. This is of interest as well when the measurement matrix may change as a function of the details of what is measured. This problem has been considered recently for Gaussian measurement noise, and here we develop this idea with application to Poisson systems. A collaborative maximum likelihood algorithm and alternating proximal gradient algorithm are proposed, and associated theoretical performance guarantees are established based on newly derived concentration-of-measure results. A Bayesian model is then introduced, to improve flexibility and generality. Connections between the maximum likelihood methods and the Bayesian model are developed, and example results are presented for a real compressive X-ray imaging system.

Bayesian compressive sensing↗

A multiresolution spatial parametrization for the estimation of fossil-fuel carbon dioxide emissions via atmospheric inversions.

The estimation of fossil-fuel CO2 emissions (ffCO2) from limited ground-based and satellite measurements of CO2 concentrations will form a key component of the monitoring of treaties aimed at the abatement of greenhouse gas emissions. To that end, we construct a multiresolution spatial parametrization for fossil-fuel CO2 emissions (ffCO2), to be used in atmospheric inversions. Such a parametrization does not currently exist. The parametrization uses wavelets to accurately capture the multiscale, nonstationary nature of ffCO2 emissions and employs proxies of human habitation, e.g., images of lights at night and maps of built-up areas to reduce the dimensionality of the multiresolution parametrization. The parametrization is used in a synthetic data inversion to test its suitability for use in atmospheric inverse problem. This linear inverse problem is predicated on observations of ffCO2 concentrations collected at measurement towers. We adapt a convex optimization technique, commonly used in the reconstruction of compressively sensed images, to perform sparse reconstruction of the time-variant ffCO2 emission field. We also borrow concepts from compressive sensing to impose boundary conditions i.e., to limit ffCO2 emissions within an irregularly shaped region (the United States, in our case). We find that the optimization algorithm performs a data-driven sparsification of the spatial parametrization and retains only of those wavelets whose weights could be estimated from the observations. Further, our method for the imposition of boundary conditions leads to a 10 computational saving over conventional means of doing so. We conclude with a discussion of the accuracy of the estimated emissions and the suitability of the spatial parametrization for use in inverse problems with a significant degree of regularization.

Ray, Jaideep↗

Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion

Purpose: To develop a method to reconstruct an interior region-of-interest (ROI) image with sufficient accuracy that uses differentiated backprojection (DBP) projection onto convex sets (POCS) [H. Kudo et al., ''Tiny a priori knowledge solves the interior problem in computed tomography'', Phys. Med. Biol. 53, 2207-2231 (2008)] and a tiny knowledge that there exists a nearly piecewise constant subregion. Methods: The proposed method first employs filtered backprojection to reconstruct an image on which a tiny region P with a small variation in the pixel values is identified inside the ROI. Total variation minimization [H. Yu and G. Wang, ''Compressed sensing based interior tomography'', Phys. Med. Biol. 54, 2791-2805 (2009); W. Han et al., ''A general total variation minimization theorem for compressed sensing based interior tomography'', Int. J. Biomed. Imaging 2009, Article 125871 (2009)] is then employed to obtain pixel values in the subregion P, which serve as a priori knowledge in the next step. Finally, DBP-POCS is performed to reconstruct f(x,y) inside the ROI. Clinical data and the reconstructed image obtained by an x-ray computed tomography system (SOMATOM Definition; Siemens Healthcare) were used to validate the proposed method. The detector covers an object with a diameter of {approx}500 mm. The projection data were truncated either moderately to limit the detector coverage to diameter 350 mm of the object or severely to cover diameter 199 mm. Images were reconstructed using the proposed method. Results: The proposed method provided ROI images with correct pixel values in all areas except near the edge of the ROI. The coefficient of variation, i.e., the root mean square error divided by the mean pixel values, was less than 2.0% or 4.5% with the moderate or severe truncation cases, respectively, except near the boundary of the ROI. Conclusions: The proposed method allows for reconstructing interior ROI images with sufficient accuracy with a tiny knowledge that there exists a nearly piecewise constant subregion.

60 APPLIED LIFE SCIENCES↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

A Resonant Metamaterial Line Array for Ultrasound Compressive Imaging

Abstract Acoustic metamaterials have been proposed for numerous applications including subwavelength imaging, impedance matching, and lensing. Yet, their application in compressive sensing and imaging has not been fully investigated. When metamaterials are used as resonators at certain frequencies, they can generate random radiation patterns in the transmitted waves from the transducers and received waves from a target. Compressive sensing favors such randomness inasmuch as it can increase incoherence by decreasing the amount of mutual information between any two different measurements. This study aims at assessing whether the use of resonating metamaterial unit cells in a single-layered non-optimized array between a number of ultrasound transceivers and targets can improve the sensing capacity, point-spread function of the sensing array (their beam focusing ability), and imaging performance in point-like target detection. The theoretical results are promising and can open the way for more efficient metamaterial designs with the aim of enhancing ultrasound imaging with lower number of transceivers compared to the regular systems.

Acoustics↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

Construction of ground-state preserving sparse lattice models for predictive materials simulations

First-principles based cluster expansion models are the dominant approach in ab initio thermodynamics of crystalline mixtures enabling the prediction of phase diagrams and novel ground states. However, despite recent advances, the construction of accurate models still requires a careful and time-consuming manual parameter tuning process for ground-state preservation, since this property is not guaranteed by default. In this paper, we present a systematic and mathematically sound method to obtain cluster expansion models that are guaranteed to preserve the ground states of their reference data. The method builds on the recently introduced compressive sensing paradigm for cluster expansion and employs quadratic programming to impose constraints on the model parameters. The robustness of our methodology is illustrated for two lithium transition metal oxides with relevance for Li-ion battery cathodes, i.e., Li 2x Fe 2(1-x) O 2 and Li 2x Ti 2(1-x) O 2 , for which the construction of cluster expansion models with compressive sensing alone has proven to be challenging. We demonstrate that our method not only guarantees ground-state preservation on the set of reference structures used for the model construction, but also show that out-of-sample ground-state preservation up to relatively large supercell size is achievable through a rapidly converging iterative refinement. This method provides a general tool for building robust, compressed and constrained physical models with predictive power.

36 MATERIALS SCIENCE↗

Sparse optimization of two-dimensional terahertz spectroscopy

Two-dimensional terahertz spectroscopy (2DTS) is a low-frequency analog of two-dimensional optical spectroscopy that is rapidly maturing as a probe of a wide variety of condensed matter systems. However, a persistent problem with 2DTS is the long experimental acquisition times, which prevent its broader adoption. A potential solution, requiring no increase in experimental complexity, is signal reconstruction via compressive sensing. In this work, we apply the sparse exponential mode analysis (SEMA) technique to 2DTS of a cuprate superconductor. We benchmark the performance of the algorithm in reconstructing terahertz nonlinearities and find that SEMA reproduces the asymmetric photon echo line shapes at sampling rates as low as 10%, reaching the reconstruction noise floor at sampling rates beyond 20%–30%. The success of SEMA in reproducing such subtle, asymmetric line shapes confirms compressive sensing as a general method to accelerate 2DTS and multidimensional spectroscopies more broadly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A GENERAL FRAMEWORK FOR ENHANCING SPARSITY OF GENERALIZED POLYNOMIAL CHAOS EXPANSIONS

Compressive sensing has become a powerful addition to uncertainty quantification when only limited data are available. In this paper, we provide a general framework to enhance the sparsity of the representation of uncertainty in the form of generalized polynomial chaos expansion. We use an alternating direction method to identify new sets of random variables through iterative rotations so the new representation of the uncertainty is sparser. Consequently, we increase both the efficiency and accuracy of the compressive-sensing-based uncertainty quantification method. We demonstrate that the previously developed iterative method to enhance the sparsity of Hermite polynomial expansion is a special case of this general framework. Moreover, we use Legendre and Chebyshev polynomial expansions to demonstrate the effectiveness of this method with applications in solving stochastic partial differential equations and high-dimensional (O(100)) problems.

Yang, Xiu↗

Motion-map constrained image reconstruction (MCIR): Application to four-dimensional cone-beam computed tomography

Purpose: Utilization of respiratory correlated four-dimensional cone-beam computed tomography (4DCBCT) has enabled verification of internal target motion and volume immediately prior to treatment. However, with current standard CBCT scan, 4DCBCT poses challenge for reconstruction due to the fact that multiple phase binning leads to insufficient number of projection data to reconstruct and thus cause streaking artifacts. The purpose of this study is to develop a novel 4DCBCT reconstruction algorithm framework called motion-map constrained image reconstruction (MCIR), that allows reconstruction of high quality and high phase resolution 4DCBCT images with no more than the imaging dose as well as projections used in a standard free breathing 3DCBCT (FB-3DCBCT) scan.Methods: The unknown 4DCBCT volume at each phase was mathematically modeled as a combination of FB-3DCBCT and phase-specific update vector which has an associated motion-map matrix. The motion-map matrix, which is the key innovation of the MCIR algorithm, was defined as the matrix that distinguishes voxels that are moving from stationary ones. This 4DCBCT model was then reconstructed with compressed sensing (CS) reconstruction framework such that the voxels with high motion would be aggressively updated by the phase-wise sorted projections and the voxels with less motion would be minimally updated to preserve the FB-3DCBCT. To evaluate the performance of our proposed MCIR algorithm, we evaluated both numerical phantoms and a lung cancer patient. The results were then compared with the (1) clinical FB-3DCBCT reconstructed using the FDK, (2) 4DCBCT reconstructed using the FDK, and (3) 4DCBCT reconstructed using the well-known prior image constrained compressed sensing (PICCS).Results: Examination of the MCIR algorithm showed that high phase-resolved 4DCBCT with sets of up to 20 phases using a typical FB-3DCBCT scan could be reconstructed without compromising the image quality. Moreover, in comparison with other published algorithms, the image quality of the MCIR algorithm is shown to be excellent.Conclusions: This work demonstrates the potential for providing high-quality 4DCBCT during on-line image-guided radiation therapy (IGRT), without increasing the imaging dose. The results showed that (at least) 20 phase images could be reconstructed using the same projections data, used to reconstruct a single FB-3DCBCT, without streak artifacts that are caused by insufficient projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗

SU-C-207-05: A Comparative Study of Noise-Reduction Algorithms for Low-Dose Cone-Beam Computed Tomography

Purpose: To study different noise-reduction algorithms and to improve the image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low-dose cone-beam CT, the reconstructed image is contaminated with excessive quantum noise. In this study, three well-developed noise reduction algorithms namely, a) penalized weighted least square (PWLS) method, b) split-Bregman total variation (TV) method, and c) compressed sensing (CS) method were studied and applied to the images of a computer–simulated “Shepp-Logan” phantom and a physical CATPHAN phantom. Up to 20% additive Gaussian noise was added to the Shepp-Logan phantom. The CATPHAN phantom was scanned by a Varian OBI system with 100 kVp, 4 ms and 20 mA. For comparing the performance of these algorithms, peak signal-to-noise ratio (PSNR) of the denoised images was computed. Results: The algorithms were shown to have the potential in reducing the noise level for low-dose CBCT images. For Shepp-Logan phantom, an improvement of PSNR of 2 dB, 3.1 dB and 4 dB was observed using PWLS, TV and CS respectively, while for CATPHAN, the improvement was 1.2 dB, 1.8 dB and 2.1 dB, respectively. Conclusion: Penalized weighted least square, total variation and compressed sensing methods were studied and compared for reducing the noise on a simulated phantom and a physical phantom scanned by low-dose CBCT. The techniques have shown promising results for noise reduction in terms of PSNR improvement. However, reducing the noise without compromising the smoothness and resolution of the image needs more extensive research.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-12: A Novel Haar Wavelet Based Approach to Deliver Non-Coplanar Intensity Modulated Radiotherapy Using Sparse Orthogonal Collimators

Purpose: Existing efforts to replace complex multileaf collimator (MLC) by simple jaws for intensity modulated radiation therapy (IMRT) resulted in unacceptable compromise in plan quality and delivery efficiency. We introduce a novel fluence map segmentation method based on compressed sensing for plan delivery using a simplified sparse orthogonal collimator (SOC) on the 4π non-coplanar radiotherapy platform. Methods: 4π plans with varying prescription doses were first created by automatically selecting and optimizing 20 non-coplanar beams for 2 GBM, 2 head & neck, and 2 lung patients. To create deliverable 4π plans using SOC, which are two pairs of orthogonal collimators with 1 to 4 leaves in each collimator bank, a Haar Fluence Optimization (HFO) method was used to regulate the number of Haar wavelet coefficients while maximizing the dose fidelity to the ideal prescription. The plans were directly stratified utilizing the optimized Haar wavelet rectangular basis. A matching number of deliverable segments were stratified for the MLC-based plans. Results: Compared to the MLC-based 4π plans, the SOC-based 4π plans increased the average PTV dose homogeneity from 0.811 to 0.913. PTV D98 and D99 were improved by 3.53% and 5.60% of the corresponding prescription doses. The average mean and maximal OAR doses slightly increased by 0.57% and 2.57% of the prescription doses. The average number of segments ranged between 5 and 30 per beam. The collimator travel time to create the segments decreased with increasing leaf numbers in the SOC. The two and four leaf designs were 1.71 and 1.93 times more efficient, on average, than the single leaf design. Conclusion: The innovative dose domain optimization based on compressed sensing enables uncompromised 4π non-coplanar IMRT dose delivery using simple rectangular segments that are deliverable using a sparse orthogonal collimator, which only requires 8 to 16 leaves yet is unlimited in modulation resolution. This work is supported in part by Varian Medical Systems, Inc. and NIH R43 CA18339.

60 APPLIED LIFE SCIENCES↗

Systematic parameter inference in stochastic mesoscopic modeling

We propose a method to efficiently determine the optimal coarse-grained force field in mesoscopic stochastic simulations of Newtonian fluid and polymer melt systems modeled by dissipative particle dynamics (DPD) and energy conserving dissipative particle dynamics (eDPD). The response surfaces of various target properties (viscosity, diffusivity, pressure, etc.) with respect to model parameters are constructed based on the generalized polynomial chaos (gPC) expansion using simulation results on sampling points (e.g., individual parameter sets). To alleviate the computational cost to evaluate the target properties, we employ the compressive sensing method to compute the coefficients of the dominant gPC terms given the prior knowledge that the coefficients are “sparse”. The proposed method shows comparable accuracy with the standard probabilistic collocation method (PCM) while it imposes a much weaker restriction on the number of the simulation samples especially for systems with high dimensional parametric space. Fully access to the response surfaces within the confidence range enables us to infer the optimal force parameters given the desirable values of target properties at the macroscopic scale. Moreover, it enables us to investigate the intrinsic relationship between the model parameters, identify possible degeneracies in the parameter space, and optimize the model by eliminating model redundancies. The proposed method provides an efficient alternative approach for constructing mesoscopic models by inferring model parameters to recover target properties of the physics systems (e.g., from experimental measurements), where those force field parameters and formulation cannot be derived from the microscopic level in a straight forward way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗