Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Optimization of Operating Profit for the FEED of the PZAS Process for CO 2 Capture on a 460 MW NGCC

A rating model of PZAS (Piperazine with the Advanced Stripper) for a 460 MW natural gas combined cycle was developed from vendor-provided equipment performance data. Surrogate rating models were built and used to optimize variable profit of the system subject to natural gas and electricity price at a fixed value for CO 2 of $\$80$/tonne. Several process constraints were considered between ambient temperatures of 4.4 and 40.5 °C. Lower lean loading resulted in lower reboiler heat duty of about 2.2 GJ/tonne. Lean loading at 0.2 mol/equiv N was sufficient at an ambient temperature of 4.4 °C to maximize variable profit. Solvent precipitation was avoided even at low lean loading (0.18 mol/mol) in the absence of a trim cooler for the lean solvent between the absorber and the cold cross exchanger. Optimal CO 2 removal was always higher than the design case removal of 90% and achieved a peak of 93.6% for 4.4 ºC ambient temperature. Lean solvent rate was a significant driver of profitability. The maximum capacity of the compressor was a significant constraint on profitability. Increasing compressor capacity by 20–30% could increase variable profit by about 21% in the case of 0.18 lean loading at 4.4 °C ambient temperature. Furthermore, this increase in profit was lower at higher ambient temperature and higher lean loading. The breakeven gas price was $\$4.6$/MMBtu at high lean loading of 0.22 mol/mol. Below this value, profit was maximized by increasing the boiler heat rate. Above this value, profit could not be increased by burning additional natural gas, requiring a reduction in boiler heat rate and consequently, specific heat duty. At lower lean loading (0.2, 0.18 mol/mol), this transition in heat duty was not observed due to the lower heat duty. As the ambient temperature increased, a similar trend in heat duty was observed at 0.22 lean loading, but the transition to lower heat duty occurred earlier at $\$4$/MMBtu. This was because of the lower CO 2 production at higher ambient temperature, making the process unprofitable at a gas price higher than $\$3$/MMBtu unless the heat duty of the stripper and natural gas boiler is steeply decreased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pd-Ru pair on Pt surface for promoting hydrogen oxidation and evolution in alkaline media

Hydrogen oxidation reaction in alkaline media is critical for alkaline fuel cells and electrochemical ammonia compressors. The slow hydrogen oxidation reaction in alkaline electrolytes requires large amounts of scarce and expensive platinum catalysts. While transition metal decoration can enhance Pt catalysts’ activity, it often reduces the electrochemical active surface area, limiting the improvement in Pt mass activity. Here, we enhance Pt catalysts’ activity without losing surface-active sites by using a Pd-Ru pair. Utilizing a mildly catalytic thermal pyrolysis approach, Pd-Ru pairs are decorated on Pt, confirmed by extended X-ray absorption fine structure and high-angle annular dark-field scanning transmission electron microscopy. Density functional theory and ab-initio molecular dynamics simulations indicate preferred Pd and Ru dopant adsorption. The Pd-Ru decorated Pt catalyst exhibits a mass-based exchange current density of 1557 ± 85 A g –1 metal for hydrogen oxidation reaction, demonstrating superior performance in an ammonia compressor.

25 ENERGY STORAGE↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Commissioning plan for LCLS II 2 K cold box

Commissioning of the LCLS II cryogenic plant has been planned with respect to electrical and mechanical systems checkout, equipment cleanup, cool-down, and individual performance evaluation. This plant consists of warm and cold storage, helium compressors, 4.5 K and 2 K cold boxes, and all auxiliaries typical for helium refrigeration processes. The 2 K cold box, consisting of five cold compressors in series to produce the flow and pressures necessary for 2K operation, will be the last equipment installed and, along with an additional 10,000 L helium dewar, will allow the entire plant to be commissioned as a single entity. The pre-commissioning stages, commissioning plan for 2 K cold box without connecting to the LCLS II LINAC, additional test equipment needed to simulate the loads, all process studies and associated results are described herein.

36 MATERIALS SCIENCE↗

Unbalanced Parallel I/O: An Often-Neglected Side Effect of Lossy Scientific Data Compression

Lossy compression techniques have demonstrated promising results in significantly reducing the scientific data size while guaranteeing the compression error bounds. However, one important yet often neglected side effect of lossy scientific data compression is its impact on the performance of parallel I/O. Our key observation is that the compressed data size is often highly skewed across processes in lossy scientific compression. To understand this behavior, we conduct extensive experiments where we apply three lossy compressors MGARD, ZFP, and SZ, which are specifically designed and optimized for scientific data, to three real-world scientific applications Gray-Scott simulation, WarpX, and XGC. Our analysis result demonstrates that the size of the compressed data is always skewed even if the original data is evenly decomposed among processes. Such skewness widely exists in different scientific applications using different compressors as long as the information density of the data varies across processes. We then systematically study how this side effect of lossy scientific data compression impacts the performance of parallel I/O. We observe that the skewness in the sizes of the compressed data often leads to I/O imbalance, which can significantly reduce the efficiency of I/O bandwidth utilization if not properly handled. In addition, writing data concurrently to a single shared file through MPI-IO library is more sensitive to the unbalanced I/O loads. Therefore, we believe our research community should pay more attention to the unbalanced parallel I/O caused by lossy scientific data compression.

Wang, Xinying↗

Spatiotemporally Adaptive Compression for Scientific Dataset with Feature Preservation – A Case Study on Simulation Data with Extreme Climate Events Analysis

Scientific discoveries are increasingly constrained by limited storage space and I/O capacities. For time-series simulations and experiments, their data often need to be decimated over timesteps to accommodate storage and I/O limitations. In this paper, we propose a technique that addresses storage costs while improving post-analysis accuracy through spatiotemporal adaptive, error-controlled lossy compression. We investigate the trade-off between data precision and temporal output rates, revealing that reducing data precision and increasing timestep frequency lead to more accurate analysis outcomes. Additionally, we integrate spatiotemporal feature detection with data compression and demonstrate that performing adaptive error-bounded compression in higher dimensional space enables greater compression ratios, leveraging the error propagation theory of a transformation-based compressor. To evaluate our approach, we conduct experiments using the well-known E3SM climate simulation code and apply our method to compress variables used for cyclone tracking. Our results show a significant reduction in storage size while enhancing the quality of cyclone tracking analysis, both quantitatively and qualitatively, in comparison to the prevalent timestep decimation approach. Compared to three state-of-the-art lossy compressors lacking feature preservation capabilities, our adaptive compression framework improves perfectly matched cases in TC tracking by 26.4-51.3% at medium compression ratios and by 77.3-571.1% at large compression ratios, with a merely 5–11% computational overhead.

Gong, Qian↗

A General Framework for Error-controlled Unstructured Scientific Data Compression

Data compression plays a key role in reducing storage and I/O costs. Traditional lossy methods primarily target data on rectilinear grids and cannot leverage the spatial coherence in unstructured mesh data, leading to suboptimal compression ratios. We present a multi-component, error-bounded compression framework designed to enhance the compression of floating-point unstructured mesh data, which is common in scientific applications. Our approach involves interpolating mesh data onto a rectilinear grid and then separately compressing the grid interpolation and the interpolation residuals. This method is general, independent of mesh types and typologies, and can be seamlessly integrated with existing lossy compressors for improved performance. We evaluated our framework across twelve variables from two synthetic datasets and two real-world simulation datasets. The results indicate that the multi-component framework consistently outperforms state-of-the-art lossy compressors on unstructured data, achieving, on average, a 2.3 − 3.5× improvement in compression ratios, with error bounds ranging from 1 × 10 the −6 to 1×10−2. We further investigate impact of hyperparameters, such as grid spacing and error allocation, to deliver optimal compression ratios in diverse datasets.

Gong, Qian↗

Efficient I/O for Neural Network Training with Compressed Data

FanStore is a shared object store that enables efficient and scalable neural network training on supercomputers. By providing a global cache layer on node-local burst buffers using a compressed representation, it significantly enhances the processing capability of deep learning (DL) applications on existing hardware. In addition, FanStore allows POSIX-compliant file access to the compressed data in user space. We investigate the tradeoff between runtime overhead and data compression ratio using real-world datasets and applications, and propose a compressor selection algorithm to maximize storage capacity given performance constraints. We consider both asynchronous (i.e., with prefetching) and synchronous I/O strategies, and propose mechanisms for selecting compressors for both approaches. Using FanStore, the same storage hardware can host 2-13x more data for example applications without significant runtime overhead. Empirically, our experiments show that FanStore scales to 512 compute nodes with near linear performance scalability.

Zhang, Zhao↗

Towards Feature-Preserving 2D and 3D Vector Field Compression

The objective of this work is to develop error-bounded lossy compression methods to preserve topological features in 2D and 3D vector fields. Specifically, we explore the preservation of critical points in piecewise linear vector fields. We define the preservation of critical points as, without any false positive, false negative, or false type change in the decompressed data, (1) keeping each critical point in its original cell and (2) retaining the type of each critical point (e.g., saddle and attracting node). The key to our method is to adapt a vertex-wise error bound for each grid point and to compress input data together with the error bound field using a modified lossy compressor. Our compression algorithm can be also embarrassingly parallelized for large data handling and in situ processing. We benchmark our method by comparing it with existing lossy compressors in terms of false positive/negative/type rates, compression ratio, and various vector field visualizations with several scientific applications.

critical points↗

A High-Quality Workflow for Multi-Resolution Scientific Data Reduction and Visualization

Multi-resolution methods such as Adaptive Mesh Refinement (AMR) can enhance storage efficiency for HPC applications generating vast volumes of data. However, their applicability is limited and cannot be universally deployed across all applications. Furthermore, integrating lossy compression with multi-resolution techniques to further boost storage efficiency encounters significant barriers. To this end, we introduce an innovative workflow that facilitates high-quality multi-resolution data compression for both uniform and AMR simulations. Initially, to extend the usability of multi-resolution techniques, our workflow employs a compression-oriented Region of Interest (ROI) extraction method, transforming uniform data into a multi-resolution format. Subsequently, to bridge the gap between multi-resolution techniques and lossy compressors, we optimize three distinct compressors, ensuring their optimal performance on multi-resolution data. These optimizations can improve the compression ratio of SOTA approaches by up to 3.3× under the same data quality loss. Lastly, we incorporate an advanced uncertainty visualization method into our workflow to understand the potential impacts of lossy compression. Experimental evaluation demonstrates that our workflow achieves significant compression quality improvements.

Wang, Daoce↗

Operation of Natural Gas Pipeline Networks With Storage Under Transient Flow Conditions

Here, we formulate a nonlinear optimal control problem for intraday operation of a natural gas pipeline network that includes storage reservoirs. The dynamics of compressible gas flow through pipes, compressors, reservoirs, and wells are considered. In particular, a reservoir is modeled as a rigid, hollow container that stores gas under isothermal conditions and uniform density, and a well is modeled as a vertical pipe. For each pipe, flow dynamics are described by a coupled partial differential equation (PDE) system in density and mass flux variables, with momentum dissipation modeled using the Darcy–Wiesbach friction approximation. Compressors are modeled as scaling up the pressure of gas between the inlet and outlet. The governing equations for all network components are spatially discretized and assembled into a nonlinear differential-algebraic equation (DAE) system, which synthesizes above-ground pipeline and subsurface reservoir dynamics into a single reduced-order model. We seek to maximize an objective function that quantifies economic profit and network efficiency subject to the flow equations and inequalities that represent operating limitations. The problem is solved using a primal–dual interior point solver, and the solutions are validated in computational experiments and simulations on several pipeline test networks to demonstrate the effectiveness of the proposed methodology.

03 NATURAL GAS↗

waveSZ: A Hardware-Algorithm Co-Design of Efficient Lossy Compression for Scientific Data

Error-bounded lossy compression is critical to the success of extreme-scale scientific research because of ever-increasing volumes of data produced by today's high-performance computing (HPC) applications. Not only can error-controlled lossy compressors significantly reduce the I/O and storage burden but they can retain high data fidelity for post analysis. Existing state-of-the-art lossy compressors, however, generally suffer from relatively low compression and decompression throughput (up to hundreds of megabytes per second on a single CPU core), which considerably restrict the adoption of lossy compression by many HPC applications especially those with a fairly high data production rate. In this paper, we propose a highly efficient lossy compression approach based on field programmable gate arrays (FPGAs) under the state-of-the-art lossy compression model SZ. Our contributions are fourfold. (1) We adopt a wavefront memory layout to alleviate the data dependency during the prediction for higher-dimensional predictors, such as the Lorenzo predictor. (2) We propose a co-design framework named WAVESZ based on the wavefront memory layout and the characteristics of SZ algorithm and carefully implement it by using high-level synthesis. (3) We propose a hardware-algorithm co-optimization method to improve the performance. (4) We evaluate our proposed WAVESZ on three real-world HPC simulation datasets from the Scientific Data Reduction Benchmarks and compare it with other state-of-the-art methods on both CPUs and FPGAs. Experiments show that our WAVESZ can improve SZ's compression throughput by 6.9x similar to 8.7x over the production version running on a state-of-the-art CPU and improve the compression ratio and throughput by 2.1x and 5.8x on average, respectively, respectively, compared with the state-of-the-art FPGA design.

Compression Ratio↗

What to Support When You’re Compressing

Over the last nearly 20 years, lossy compression has become an essential aspect of HPC applications’ data pipelines, allowing them to overcome limitations in storage capacity and bandwidth and, in some cases, increase computational throughput and capacity. However, with the adoption of lossy compression comes the requirement to assess and control the impact lossy compression has on scientific outcomes. In this work, we take a major step forward in describing the state of practice and by characterizing workloads. We examine applications’ needs and compressors’ capabilities across 9 different supercomputing application domains. We present 24 takeaways that provide best practices for applications, operational impacts for facilities achieving compressed data, and gaps in application needs not addressed by production compressors that point towards opportunities for future compression research.

Error-Bounded Lossy Compression↗