Search NASA⌕ Search

SEARCH · Search NASA

Results for “conducting polymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Additive-Induced Morphology Change of Polymer Film Enables Enhanced Charge Mobility and Faster Organic Electrochemical Transistor Switching

Conjugated polymers (CPs) play an important role in organic electrochemical transistors (OECTs) for bioelectronics and related applications, where they serve as channel materials. Currently, most successful polymers for CPs are re-engineered from traditional CPs by replacing hydrophobic alkyl side chains with hydrophilic ethylene glycol or ionic groups. Frustratingly, the enhanced ion transport often compromises the charge mobility of the original CP. In this work, we present an additive-mediated method to construct a modified poly(3-hexylthiophene) (P3HT) film to enable efficient ion migration. The additive is designed with a cleavable diazo group that releases nitrogen and 2-methoxyethanol, a volatile compound, to alter the P3HT film morphology. OECTs based on the film exhibit improved response times. Interestingly, the process also enhances the crystallinity of P3HT, leading to higher hole mobility compared with pristine P3HT. This study proposes an in situ strategy to achieve the functionality of the OMIEC via morphological regulation, offering a promising route to simultaneously enhance both ion accessibility and charge mobility.

Organic polymers↗

Novel Micro ElectroMechanical Systems (MEMS) Packaging for the Skin of the Satellite

This paper includes a discussion of the novel packaging techniques that are needed to place MEMS based thermal control devices on the skin of various satellites, eliminating the concern associated with potential particulates &om integration and test or the launch environment. Protection of this MEMS based thermal device is achieved using a novel polymer that is both IR transmissive and electrically conductive. This polymer was originally developed and qualified for space flight application by NASA at the Langley Research Center. The polymer material, commercially known as CPI, is coated with a thin layer of ITO and sandwiched between two window-like frames. The packaging of the MEMS based radiator assembly offers the benefits of micro-scale devices in a chip on board fashion, with the level of protection generally found in packaged parts.

Darrin, M. Ann↗

Transparent and Electrically Conductive Carbon Nanotube-Polymer Nanocomposite Materials for Electrostatic Charge Dissipation

In recent years, nanocomposite materials have been extensively studied because of their superior electrical, magnetic, and optical properties and large number of possible applications that range from nano-electronics, specialty coatings, electromagnetic shielding, and drug delivery. The aim of the present work is to study the electrical and optical properties of carbon nanotube(CNT)-polymer nanocomposite materials for electrostatic charge dissipation. Single and multi-wall carbon nanotubes were grown by catalytic chemical vapor deposition (CCVD) on metal/metal oxide catalytic systems using acetylene or other hydrocarbon feedstocks. After the purification process, in which amorphous carbon and non-carbon impurities were removed, the nanotubes were functionalized with carboxylic acid groups in order to achieve a good dispersion in water and various other solvents. The carbon nanostructures were analyzed, both before and after functionalization by several analytical techniques, including microscopy, Raman spectroscopy, and X-Ray photoelectron spectroscopy. Solvent dispersed nanotubes were mixed (1 to 7 wt %) into acrylic polymers by sonication and allowed to dry into 25 micron thick films. The electrical and optical properties of the films were analyzed as a function of the nanotubes' concentration. A reduction in electrical resistivity, up to six orders of magnitude, was measured as the nanotubes' concentration in the polymeric films increased, while optical transparency remained 85 % or higher relative to acrylic films without nanotubes.

Dervishi, E.↗

Thermal Conductivity of Ultem(TradeMark)/Carbon Nanofiller Blends

In an effort to improve polymer thermal conductivity (TC), Ultem(TradeMark) 1000 was compounded with nano-fillers of carbon allotropes. Ultem(TradeMark) 1000 was selected since it is both solution and melt processable. As-received and modified multiwalled carbon nanotubes (MWCNTs), vapor grown carbon nanofibers (CNF) and expanded graphite (EG) were investigated. MWCNTs were modified by functionalizing the surface through oxidization with concentrated acids, mixing with an alkyl bromide, and addition of alkyl and phosphorus compounds after initial treatment with n-butyl lithium. Functionalization was performed to improve the TC compatibility between the resin and MWCNTs. It was postulated that this may provide an improved interface between the MWCNT and the polymer which would result in enhanced TC. The nano-fillers were mixed with Ultem(TradeMark) 1000 in the melt and in solution at concentrations ranging from 5 to 40 wt%. Ribbons were extruded from the blends to form samples where the nano-fillers were aligned to some degree in the extrusion direction. Samples were also fabricated by compression molding resulting in random orientation of the nano-fillers. Thermal properties of the samples were evaluated by Differential Scanning Calorimetry (DSC) and Thermal Gravimetric Analyzer (TGA). Tensile properties of aligned samples were determined at room temperature. The specimens were cut from the ribbons in the extrusion direction; hence the nano-fillers are somewhat aligned in the direction of stress. Typically it was observed that melt mixed samples exhibited superior mechanical properties compared to solution mixed samples. As expected, increased filler loading led to increased modulus and decreased elongation with respect to the neat polymer. The degree of dispersion and alignment of the nano-fillers was determined by high-resolution scanning electron microscopy (HRSEM). HRSEM of the ribbons revealed that the MWCNTs and CNFs were predominantly aligned in the flow direction. The TC of the samples was measured using a Nanoflash(TradeMark) instrument. Since the MWCNTs and CNF are anisotropic, the TC was expected to be different in the longitudinal (parallel to the nanotube and fiber axis) and transverse (perpendicular to the nanotube and fiber axis) directions. The extruded ribbons provided samples for transverse TC measurements. However, to determine the TC in the longitudinal direction, the ribbons needed to be stacked and molded under 1.7 MPa and 270 C. Samples were then obtained by cutting the molded block with a diamond saw. The largest TC improvement was achieved for aligned samples when the measurement was performed in the direction of MWCNT and CNF alignment (i.e. longitudinal axis). Unaligned samples also showed a significant improvement in TC and may be potentially useful in applications when it is not possible to align the nano-filler. The results of this study will be presented.

Ghose, S.↗

Tuning Anion Composition and Mobility to Balance Ionic Conductivity and Cation Selectivity in Solid Polymer Electrolytes

Solid polymer electrolytes (SPEs) offer a promising route toward safe and high-performance electrochemical energy storage, yet a fundamental challenge in SPEs involves improving ionic conductivity while maintaining selective cation transport. The hurdle exists because ion transport is typically coupled closely to polymer segmental dynamics. Herein, a glassy single-ion-conducting polymer, poly[lithium sulfonyl(trifluoromethane sulfonyl)imide methacrylate] (PLiMTFSI), in which the anions were tethered to the polymer, was blended with a flexible polymer, poly(oligo-oxyethylene methyl ether methacrylate) (POEM), and a series of small-molecule lithium salts, in which the anions were untethered [lithium bis(trifluoromethane­sulfonyl)imide (LiTFSI), lithium bis(fluorosulfonyl)imide (LiFSI), lithium trifluoromethanesulfonate (LiTf), or lithium perchlorate (LiClO 4 )]. The impact of salt anion volume and tethered-to-untethered anion ratio on the ion conduction behavior and thermal properties of blend electrolytes was investigated. In some cases, conductivity could be enhanced through this ternary blend approach. For example, a POEM-based polymer blend containing a bulky salt anion (TFSI⁻) and an equimolar mixture of PLiMTFSI and LiTFSI exhibited a Li + conductivity (4.8×10 -4 S/cm) an order of magnitude higher than that of a comparable POEM / LiTFSI system (6.3×10 -5 S/cm) at 100 °C. This enhancement was attributed to a more than ninefold increase in lithium transference number (0.66 in the ternary blend vs. 0.07 in POEM / LiTFSI). Overall, this study highlights the potential for tuning anion composition and mobility to achieve relatively high ionic conductivities and maintain selective cation transport in SPEs, offering a pathway to enable batteries that tolerate elevated temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tensile Creep and Stress-rupture Behavior of Polymer Derived Sic Fibers

Tensile creep and stress-rupture studies were conducted on polymer derived Nicalon, Hi-Nicalon, and SiC/BN-coated Nicalon SiC fibers. Test conditions were temperatures from 1200 to 1400 C, stresses from 100 to 1600 MPa, stress application times up to 200 hours, and air, argon, and vacuum test environments. For all fibers, creep occurred predominantly in the primary stage. Hi-Nicalon had much higher 0.2 and 1 percent creep strengths than as-produced as well as-coated Nicalon fibers. The stress-rupture strength of Hi-Nicalon up to 100 hours was also higher than that of the coated and as-produced Nicalon fibers. SiC/BN coating on Nicalon increased only the short-term low-temperature rupture strength. Limited testing in argon and vacuum suggests that for all fiber types, creep and rupture resistances are reduced in comparison to the results in air. Possible mechanisms for the observed behavior are discussed.

Yun, H. M.↗

Unraveling the pathway towards superionic transport in polymer electrolytes

Ionic transport in polymers is critical for Li-ion batteries, fuel cells, flow batteries and many other energy storage and conversion technologies. A significant enhancement of ion conductivity in polymers may be achieved through an increase in the polarity of side chains and their self-organization into specific morphologies, which can potentially act as percolated ionic structures. However, higher polarity increases attractive interactions within a polymer matrix and slows down its segmental dynamics, which conversely hinders ionic transport. To overcome this tradeoff, we designed the functionalization of a Li salt-doped polymer matrix by tailored amounts of zwitterionic (ZI) groups. Our results suggest the emergence of a self-assembled percolation conductivity regime above a specific ZI concentration, in which ion hopping decouples from segmental dynamics by up to ten orders of magnitude. Consequently, in the highly concentrated ZI regime, our polymeric materials exhibit in their glassy state energy barriers for ion hopping similar to, or even smaller than, those reported for superionic ceramics. Our study also reveals that ion dynamics in the poly(zwitterion) with all monomers carrying ZI groups is significantly faster than that of a monomeric ZI compound, although the latter has much faster structural relaxation. Furthermore, this result highlights the crucial role played by the local morphology on the ion transport of polymer electrolytes and opens a new pathway for the design of superionic polymers, significantly expanding the current limited portfolio of solid-state electrolytes for energy applications.

Ion conductivity↗

Lithium Polymer Electrolytes and Solid State NMR

Research is being done at the Glenn Research Center (GRC) developing new kinds of batteries that do not depend on a solution. Currently, batteries use liquid electrolytes containing lithium. Problems with the liquid electrolyte are (1) solvents used can leak out of the battery, so larger, more restrictive, packages have to be made, inhibiting the diversity of application and decreasing the power density; (2) the liquid is incompatible with the lithium metal anode, so alternative, less efficient, anodes are required. The Materials Department at GRC has been working to synthesize polymer electrolytes that can replace the liquid electrolytes. The advantages are that polymer electrolytes do not have the potential to leak so they can be used for a variety of tasks, small or large, including in the space rover or in space suits. The polymers generated by Dr. Mary Ann Meador's group are in the form of rod -coil structures. The rod aspect gives the polymer structural integrity, while the coil makes it flexible. Lithium ions are used in these polymers because of their high mobility. The coils have repeating units of oxygen which stabilize the positive lithium by donating electron density. This aids in the movement of the lithium within the polymer, which contributes to higher conductivity. In addition to conductivity testing, these polymers are characterized using DSC, TGA, FTIR, and solid state NMR. Solid state NMR is used in classifying materials that are not soluble in solvents, such as polymers. The NMR spins the sample at a magic angle (54.7') allowing the significant peaks to emerge. Although solid state NMR is a helpful technique in determining bonding, the process of preparing the sample and tuning it properly are intricate jobs that require patience; especially since each run takes about six hours. The NMR allows for the advancement of polymer synthesis by showing if the expected results were achieved. Using the NMR, in addition to looking at polymers, allows for participation on a variety of other projects, including aero-gels and carbon graphite mat en als. The goals of the polymer electrolyte research are to improve the physical properties of the polymers. This includes improving conductivity, durability, and expanding the temperature range over which it is effective. Currently, good conductivity is only present at high temperatures. My goals are to experiment with different arrangements of rods and coils to achieve these desirable properties. Some of my experiments include changing the number of repeat units in the polymer, the size of the diamines, and the types of coil. Analysis of these new polymers indicates improvement in some properties, such as lower glass transition temperature; however, they are not as flexible as desired. With further research we hope to produce polymers that encompass all of these properties to a high degree.

Berkeley, Emily R.↗

Polycarbonate‐Based Solid‐Polymer Electrolytes for Solid‐State Sodium Batteries

Solid-polymer electrolytes comprised of polypropylene carbonate (PPC) and varied sodium bis(fluorosulfonyl)imide (NaFSI) salt concentrations are investigated for implementation as a conductive solid polymer electrolyte into solid-state cathode composites utilizing a sodium-layered oxide active material. The ionic conductivity generally increases with NaFSI salt content, reaching ≈1 mS cm −1 at 80 °C at the highest salt concentration (PPC:NaFSI = 0.5:1). Through an all-in-one slurry casting method, Na 2/3 Ni 1/3 Mn 2/3 O 2 cathode composites are fabricated in which the dispersed PPC electrolyte acts as the primary binder. Enabled by a bilayer polymer electrolyte system, cycling performance with the PPC cathode electrolyte is optimized with respect to salt concentration and anode material. The best cyclability is achieved with a moderate salt concentration electrolyte (PPC:NaFSI = 5:1), showcasing an initial capacity of 83 mA h g −1 with a remarkable 80% capacity retention after 150 cycles at C/5 rate and 60 °C. The superior performance of the lower salt concentration electrolyte is attributed to better electrochemical stability, as confirmed by linear sweep voltammetry and online electrochemical mass spectrometry measurements. In conclusion, these results underscore the potential of carbonate-based polymer electrolytes and the importance of balancing electrolyte conductivity and stability in cell design.

25 ENERGY STORAGE↗

Thermal properties of polymers below 4 K.

Obtained measurement data on the Debye contribution to the specific heat, the specific heat, and the thermal conductivity in polymers below 4 deg K are discussed. The results obtained suggest that impurities are responsible for the apparent thermal properties of polymers and glasses at low temperatures. In order to determine the intrinsic behavior of amorphous solids, measurements must be made at temperatures low enough to freeze out the local modes.

Salinger, G. L.↗

Heat conduction in metal-filled polymers - The role of particle size, shape, and orientation

This paper presents a new type of analysis for predicting the thermal conductivity of disperse composites from the properties of the component phases and elementary characterizations of particle shapes and orientation. This analysis successfully predicted the sensitivity to particle shape which was confirmed by experiments also reported in this paper. These results suggest that highly elongated particles may be used to achieve dramatic modifications of thermal conductivity and the analysis presented here may be a useful tool in the design or development of disperse composites of specific thermal conductivity. The analysis may also apply to other properties such as electrical conductivity or magnetic permeability.

Hansen, D.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensor arrays for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g. electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Suppressing thermal transport in nonporous polymer hybrids by limiting thermally accessible vibrational modes

Achieving low thermal conductivity in nonporous polymer materials without compromising mechanical integrity remains a longstanding challenge. Conventional strategies, such as introducing porosity, are inherently limited in dense systems. Here, in this study, we demonstrate that thermal transport in polymer–organic filler hybrids is closely associated with the engineered availability of thermally accessible vibrational modes, rather than individual interfacial resistance or porosity. Using PU/organic filler hybrids as a model system, we show that incorporating rigid organic motifs shifts the vibrational density of states toward higher frequencies, where vibrational modes are weakly thermally populated at ambient conditions. This limits the number of heat-carrying channels, leading to suppressed thermal conductivity despite negligible individual interfacial resistance (∼10 −9 m 2 K W −1 ). These findings provide initial evidence that vibrational mode engineering may offer a promising molecular-level route for reducing thermal conductivity in dense polymer–organic hybrid systems.

36 MATERIALS SCIENCE↗

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Understanding Thermal Transport in Polymer - Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems. Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Matthew L. Fitzgerald↗