Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

High-temperature gas-cooled reactors (HTGRs) are a relatively mature advanced reactor concept that are of interest to industry and government for near-term deployment. These systems feature passive safety through low power density, coated particle fuels, and large graphite volumes that lead to slow heatup. In loss of flow transients, cooldown is achieved through conduction and radiation heat transfer. In prismatic block-type reactors, such as the mHTGR-350, the presence of coolant holes and fuel compacts alters the flow of heat through the blocks. To capture this effect in systems codes like RELAP5-3D, relationships for effective thermal conductivity (ETC) must be used to appropriately degrade the thermal conductivity. This work presents an assessment of the impact of ETC on performance of block-type gas-cooled reactors in a pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients. Models for PCC and DCC with bulk material thermal conductivity and ETC were run for both the mHTGR-350 and the High-Temperature Test Facility (HTTF) to determine the impact of ETC on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbine cooling research

Development of improved turbine cooling processes and facilities for conducting turbine cooling research

Cochran, R. P.↗

An MHD Code for the Study of Magnetic Structures in the Solar Wind

We have developed a 2.5D MHD code designed to study how the solar wind influences the evolution of transient events in the solar corona and inner heliosphere. The code includes thermal conduction, coronal heating and radiative cooling. Thermal conduction is assumed to be magnetic field-aligned in the inner corona and transitions to a collisionless formulation in the outer corona. We have developed a stable method to handle field-aligned conduction around magnetic null points. The inner boundary is placed in the upper transition region, and the mass flux across the boundary is determined from 1D field-aligned characteristics and a 'radiative energy balance' condition. The 2.5D nature of this code makes it ideal for parameter studies not yet possible with 3D codes. We have made this code publicly available as a tool for the community. To this end we have developed a graphical interface to aid in the selection of appropriate options and a graphical interface that can process and visualize the data produced by the simulation. As an example, we show a simulation of a dipole field stretched into a helmet streamer by the solar wind. Plasmoids periodically erupt from the streamer, and we perform a parameter study of how the frequency and location of these eruptions changed in response to different levels of coronal heating. As a further example, we show the solar wind stretching a compact multi-polar flux system. This flux system will be used to study breakout coronal mass ejections in the presence of the solar wind.

corona↗

X-ray bursts from solar flares behind the limb

Data from the OSO-7 X-ray experiment were used in a search for behind-the-limb solar X-ray bursts. Seventeen active centers were found as likely seats of such bursts. The spectra of 37 over-the-limb X-ray bursts were analyzed. The distributions of maximum temperature, maximum emission measure, and characteristic cooling time do not differ in a statistically significant way from the distributions for center events. The observations support the view that the dominant cooling mechanism is conduction, for the cooling times derived from the temperature histories are too small to be explained by radiative cooling. The fraction of over-the-limb bursts which have an nonthermal component is 2/3, exactly the same as found for the 122 X-ray bursts studied in Datlowe et al. (1974b). Thick-target models of X-ray emission would suggest that hard X-ray sources would be rapidly occulted with increasing longitude of the burst location, yet just the contrary was observed.

Roy, J.-R.↗

Cooling of solar flares plasmas. 1: Theoretical considerations

Theoretical models of the cooling of flare plasma are reexamined. By assuming that the cooling occurs in two separate phase where conduction and radiation, respectively, dominate, a simple analytic formula for the cooling time of a flare plasma is derived. Unlike earlier order-of-magnitude scalings, this result accounts for the effect of the evolution of the loop plasma parameters on the cooling time. When the conductive cooling leads to an 'evaporation' of chromospheric material, the cooling time scales L(exp 5/6)/p(exp 1/6), where the coronal phase (defined as the time maximum temperature). When the conductive cooling is static, the cooling time scales as L(exp 3/4)n(exp 1/4). In deriving these results, use was made of an important scaling law (T proportional to n(exp 2)) during the radiative cooling phase that was forst noted in one-dimensional hydrodynamic numerical simulations (Serio et al. 1991; Jakimiec et al. 1992). Our own simulations show that this result is restricted to approximately the radiative loss function of Rosner, Tucker, & Vaiana (1978). for different radiative loss functions, other scaling result, with T and n scaling almost linearly when the radiative loss falls off as T(exp -2). It is shown that these scaling laws are part of a class of analytic solutions developed by Antiocos (1980).

Cargill, Peter J.↗

Delayed Development of Cool Plasmas in X-Ray Flares from the Young Sun-like Star κ1 Ceti

The Neutron star Interior Composition Explorer (NICER) X-ray observatory observed two powerful X-ray flares equivalent to superflares from the nearby young solar-like star κ 1 Ceti in 2019. NICER follows each flare from the onset through the early decay, collecting over 30 counts s −1 near the peak, enabling a detailed spectral variation study of the flare rise. The flare in September varies quickly in ∼800 s, while the flare in December has a few times longer timescale. In both flares, the hard-band (2–4 keV) light curves show typical stellar X-ray flare variations with a rapid rise and slow decay, while the soft X-ray light curves, especially of the September flare, have prolonged flat peaks. The time-resolved spectra require two temperature plasma components at kT ∼0.3–1 and ∼2–4 keV. Both components vary similarly, but the cool component lags by ∼200 s with a four to six times smaller emission measure (EM) compared to the hot component. A comparison with hydrodynamic flare loop simulations indicates that the cool component originates from X-ray plasma near the magnetic loop footpoints that mainly cools via thermal conduction. The time lag represents the travel time of the evaporated gas through the entire flare loop. The cool component has a several times smaller EM than its simulated counterpart, suggesting a suppression of conductive cooling, possibly by the expansion of the loop cross-sectional area or turbulent fluctuations. The cool component's time lag and EM ratio provide important constraints on the flare loop geometry.

main sequence stars↗

Bifunctional Asymmetric Fabric with Tailored Thermal Conduction and Radiation for Personal Cooling and Warming

Personal thermal management is emerging as a promising strategy to provide thermal comfort for the human body while conserving energy. By improving control over the heat dissipating from the human body, personal thermal management can provide effective personal cooling and warming. Here, we propose a facile surface modification approach to tailor the thermal conduction and radiation properties based on commercially available fabrics, to realize better management of the whole heat transport pathway from the human body to the ambient. Additionally, a bifunctional asymmetric fabric (BAF) offering both a cooling and a warming effect is demonstrated. Due to the advantages of roughness asymmetry and surface modification, the BAF demonstrates an effective cooling effect through enhanced heat conduction and radiation in the cooling mode; in the warming mode, heat dissipation along both routes is reduced for personal warming. As a result, a 4.6 °C skin temperature difference is measured between the cooling and warming BAF modes, indicating that the thermal comfort zone of the human body can be enlarged with one piece of BAF clothing. We expect this work to present new insights for the design of personal thermal management textiles as well as a novel solution for the facile modification of available fabrics for both personal cooling and warming.

42 ENGINEERING↗

Apparatus and methods for manufacturing high-density coil with formed cooling channels

A conductive coil for an electric application having a cooling channel for a coolant liquid or gas. The coil includes a wire winding of a plurality of wire turns. The wire winding is compressed about a cooling channel which is disposed between adjacent turn segments of the plurality of wire turns. The wire winding is formed and pressed against a shaping element to form the coolant channel within the compressed winding.

Brown, Ian Patrick↗

Ultraviolet and visible flare observations of EQ Pegasi B

EQ Peg AB (dM43+dM5.5e) was monitored in the visible at the Whipple Observatory and ultraviolet with IUE on September 2, 1981. In the visible spectrophotometry of EQ Peg B the H-beta emission strengthened by a factor of 2 relative to the nearby stellar continuum within a few minutes and decayed over an hour. This flare in EQ Peg B was coincident with the enhancement of ultraviolet emission lines of C IV 1550 A, He II 1640 A, and C II 1335 A in the combined light of EQ Peg AB. The ultraviolet fluxes during the flare can be interpreted as similar to those either in the thermal phases of large two-ribbon solor flares where radiative cooling balances thermal conduction or in gas cooling quickly from X-ray emitting temperatures. The appearance of the ultraviolet continuum at 1700-1900 A and ratio of H-alpha to H-beta fluxes during the flare are consistent with models producing these emissions in the chromosphere.

Baliunas, S. L.↗

A Versatile Rocket Engine Hot Gas Facility

The capabilities of a versatile rocket engine facility, located in the Rocket Laboratory at the NASA Lewis Research Center, are presented. The gaseous hydrogen/oxygen facility can be used for thermal shock and hot gas testing of materials and structures as well as rocket propulsion testing. Testing over a wide range of operating conditions in both fuel and oxygen rich regimes can be conducted, with cooled or uncooled test specimens. The size and location of the test cell provide the ability to conduct large amounts of testing in short time periods with rapid turnaround between programs.

Green, James M.↗

Investigation of Enhanced Surface Spray Cooling

Experiments were conducted to study the effects of enhanced surfaces on heat transfer during spray cooling. The surface enhancements consisted of cubic pin fins, pyramids, and straight fins (uniform cross sectional straight fins) machined on the top surface of copper heater blocks. Each had a cross-sectional area of 2.0 square cm. Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2x2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data was obtained under nominally degassed (chamber pressure of 41.4 kPa ) and gassy conditions (chamber with N2 gas at 101 kPa). The results show that the straight fins had the largest enhancement in heat flow. Critical heat flux (CHF) for this surface showed an increase of 55% in comparison to the flat surface for the nominally degassed condition. The cubic pin finned and pyramid surfaces provided slightly more than half the heat flux enhancement (30% - 40% greater than the flat surface) of the straight fins. The gassy case showed that the straight fins again provided the largest enhancement (48%) in CHF relative to the flat surface. This was followed by the cubic pin fins, and pyramids which had increases of 31% and 18% respectively. No significant effect was observed in the surface temperature at which CHF occurs for either portion of the study.

Silk, Eric A.↗

The effect of saturated thermal conduction on clouds in a hot plasma

We numerically investigate the internal evolution of multiphase clouds, which are at rest with respect to an ambient, highly ionized medium (HIM) representing the hot component of the circumgalactic medium. Time-dependent saturated thermal conduction and its implications like condensation rates and mixing efficiency are assessed in multiphase clouds. Our simulations are carried out by using the adaptive mesh refinement code FLASH. The model clouds are initially in both hydrostatic and thermal equilibrium and are in pressure balance with the HIM. Thus, they have steep gradients in both temperature and density at the interface to HIM leading to non-negligible thermal conduction. Several physical processes are considered numerically or semi-analytically: thermal conduction, radiative cooling and external heating of gas, self-gravity, mass diffusion, and dissociation of molecules and ionization of atoms. It turns out that saturated thermal conduction triggers a continuous condensation irrespective of cloud mass. Dynamical interactions with ambient HIM all relate to the radial density gradient in the clouds: (1) mass flux due to condensation is the higher the more homogeneous the clouds are; (2) mixing of condensed gas with cloud gas is easier in low-mass clouds, because of their shallower radial density gradient; and thus (3) accreted gas is distributed more efficiently. A distinct and sub-structured transition zone forms at the interface between cloud and HIM, which starts at smaller radii and is much narrower as deduced from analytical theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Redesign of the Extravehicular Mobility Unit Airlock Cooling Loop Recovery Assembly

During EVA (Extravehicular Activity) 23 aboard the ISS (International Space Station) on 07/16/2013 an episode of water in the EMU (Extravehicular Mobility Unit) helmet occurred, necessitating a termination of the EVA (Extravehicular Activity) shortly after it began. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR (Airlock Cooling Loop Recovery) Ion Beds which led to various levels of contaminants being introduced into the Ion Beds before they left the ground. The Ion Beds were thereafter used to scrub the failed EMU cooling water loop on-orbit during routine scrubbing operations. The root cause investigation identified several areas for improvement of the ALCLR Assembly which have since been initiated. Enhanced washing techniques for the ALCLR Ion Bed have been developed and implemented. On-orbit cooling water conductivity and pH analysis capability to allow the astronauts to monitor proper operation of the ALCLR Ion Bed during scrubbing operation is being investigation. A simplified means to acquire on-orbit EMU cooling water samples have been designed. Finally, an inherently cleaner organic adsorbent to replace the current lignite-based activated carbon, and a non-separable replacement for the separable mixed ion exchange resin are undergoing evaluation. These efforts are undertaken to enhance the performance and reduce the risk associated with operations to ensure the long-term health of the EMU cooling water circuit.

Steele, John↗

Redesign of the Extravehicular Mobility Unit Airlock Cooling Loop Recovery Assembly

During EVA (Extravehicular Activity) 23 aboard the ISS (International Space Station) on 07/16/2013 an episode of water in the EMU (Extravehicular Mobility Unit) helmet occurred, necessitating a termination of the EVA (Extravehicular Activity) shortly after it began. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR (Airlock Cooling Loop Recovery) Ion Beds which led to various levels of contaminants being introduced into the Ion Beds before they left the ground. The Ion Beds were thereafter used to scrub the failed EMU cooling water loop on-orbit during routine scrubbing operations. The root cause investigation identified several areas for improvement of the ALCLR Assembly which have since been initiated. Enhanced washing techniques for the ALCLR Ion Bed have been developed and implemented. On-orbit cooling water conductivity and pH analysis capability to allow the astronauts to monitor proper operation of the ALCLR Ion Bed during scrubbing operation is being investigated. A simplified means to acquire on-orbit EMU cooling water samples has been designed. Finally, an inherently cleaner organic adsorbent to replace the current lignite-based activated carbon, and a non-separable replacement for the separable mixed ion exchange resin are undergoing evaluation. These efforts are undertaken to enhance the performance and reduce the risk associated with operations to ensure the long-term health of the EMU cooling water circuit.

Steele, John↗

Status of the Redesign of the Extravehicular Mobility Unit Airlock Cooling Loop Recovery Assembly

During EVA (Extravehicular Activity) 23 aboard the ISS (International Space Station) on 07/16/2013 an episode of water in the EMU (Extravehicular Mobility Unit) helmet occurred, necessitating a termination of the EVA (Extravehicular Activity) shortly after it began. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR Ion Beds which led to various levels of contaminants being introduced into the Ion Beds before they left the ground. The Ion Beds were thereafter used to perform on-orbit routine scrubbing operations for the EMU cooling water loop which led to the failure. The root cause investigation identified several areas for improvement of the ALCLR Assembly which have since been initiated. Enhanced washing techniques for the ALCLR Ion Bed have been developed and implemented. On-orbit cooling water conductivity and pH analysis capability to allow the astronauts to monitor proper operation of the ALCLR Ion Bed during scrubbing operation have been investigated and are being incorporated. A simplified means to acquire on-orbit EMU cooling water samples has been designed as well. Finally, an inherently cleaner organic adsorbent to replace the current lignite-based activated carbon, and a non-separable replacement for the separable mixed ion exchange resin have been selected. These efforts are being undertaken to enhance the performance and reduce the risk associated with operations to ensure the long-term health of the EMU cooling water circuit. The intent of this paper is to provide an update of the effort to re-design the ALCLR (Airlock Cooling Loop Recovery) hardware. Last year, this effort was in the early stages of concept development and test which was reported in ICES Paper ICES-2016-221. Those phases are now complete and the final outcomes, as well as plans to build and field the hardware, are being reported on.

Steele, John↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗