At least 199 records · Page 11

Scaling Behavior of Thermally Driven Fractures in Deep Low‐Permeability Formations: A Plane Strain Model With 1‐D Heat Conduction

Abstract Injection of cold fluids through/into deep formations may cause significant cooling, thermal stress, and possible thermal fracturing. In this study, the thermal fracturing of low‐permeability formations under one‐dimensional heat conduction was investigated using a plane strain model. Dimensionless governing equations, with dimensionless fracture length , aperture , spacing , time , and effective confining stress , were derived. Solution of single thermal fracture was derived analytically, while solution of multiple fractures with constant (or dynamic) spacing were obtained using the displacement discontinuity method (and stability analysis). For single fracture, increases nonlinearly with and then transitions to scaling law , indicating that late‐time fracture length increases linearly with the square root of cooling time. For constantly spaced fractures, deviates from the single‐fracture solution at a later for a larger , showing slower propagation under inter‐fracture stress interaction . For dynamically spaced fractures, fracture arrest induced by stress interaction was determined by the stability analysis; the fully transient solution provides evolution of dimensionless fracture length, spacing, aperture, and pattern; a similar scaling law, with , obtained shows the effect of both stress interaction and fracture arrest. The solution and scaling law provide fast predictions for all reservoir and cooling conditions using (single) model parameter . Application to a geothermal site with demonstrates that thermal fractures reach 0.67, 6.25, and 78.00 m in length, 0.49, 2.30, and 13.00 m in spacing, and 0.43, 2.09, and 12.19 mm in aperture at 1, 100, and 10,000 days.

Chen, Bin↗

Propagating neutronic uncertainties for FFTF LOFWOS Test #13

The safety evaluation conducted for licensing a Sodium-cooled Fast Reactor (SFR) may require modeling transients with best-estimate calculation tools that must first be validated against real-world measurements. To provide the community with a valuable benchmarking opportunity for validating SFR analysis tools and methods, the International Atomic Energy Agency (IAEA) initiated a coordinated research project (CRP) in 2018 for the analysis of the Fast Flux Test Facility (FFTF) Loss of Flow Without Scram (LOFWOS) Test #13. The impact of nuclear data uncertainties on neutronics parameters was previously investigated based on the COMMARA-2.0 covariance matrix. Since the transient simulation results are very sensitive to certain reactivity coefficients, it was decided to employ rigorous uncertainty propagation methods to quantify the impact of nuclear data uncertainties on the best-estimate predication of FFTF LOFWOS Test #13. The DAKOTA code is used to propagate neutronic uncertainties through SAS4A/SASSYS-1 transient simulations, while taking into account spatial and reaction-wise correlations within these uncertainties. This study shows that the remaining discrepancies observed between the Argonne National Laboratory (ANL) best-estimate results and the experimental measurements can be partly explained by the uncertainty associated with Gas Expansion Module (GEM) worth, which contributes the majority of the overall nuclear data uncertainty on the output from the FFTF LOFWOS Test #13 transient simulation. This study also confirmed the importance of including spatial and reaction-wise correlations of nuclear data uncertainties on feedback coefficients in the uncertainty propagation to avoid under-estimating their impact during the transient simulations.

42 ENGINEERING↗

Thermal Integration of a High Power Polyphase Inductive Coil Assembly

As inductive wireless power transfer reaches higher power levels; thermal management becomes essential. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies with thermally conductive materials and integrating backside liquid cooling into coil assemblies. This work adds to these developments by considering the thermal analysis and construction of a liquid-cooled high power polyphase wireless power transfer ground assembly intended for long duration operation at high power levels, aiming towards hundreds of kW or even 1 MW.

Foote, Andrew↗

Simulation of Helium Flow Visualization Apparatus for Studies of Blanket Cooling in Fusion Reactors

Flow visualization is essential to understanding helium cooling performance. This article investigates helium flow visualization in an apparatus to support the design of the blanket first wall for a fusion reactor. Helium’s safety advantages make it an attractive coolant, but effective cooling and flow visualization remain challenging. Sophisticated simulations are conducted in different test sections to address three key areas in the design of a test apparatus and cooling channel enhancements: the influence of viewing glass windows on flow patterns, the impact of increased heating, and the effectiveness of cooling structures like baffles. Viewing glass windows introduce flow recirculation region bifurcation and flow asymmetry, affecting flow patterns and necessitating careful analysis in future experiments. Increased heating results in helium flow detachment from the heated surface, leading to hot spots. Cooling structures, particularly baffles, prove effective in maintaining consistent attachment to the heated surface, improving the heat transfer performance. Further, this study also examines a tunable parameter in the turbulence model, highlighting the importance of accurate model tuning for future fusion reactor cooling designs. With an imminent helium flow visualization facility, these simulations will be used to optimize cooling structures on the heated wall to improve flow attachment and heat transfer efficiency. This work serves as a first investigation of the helium flow visualization apparatus for blanket cooling enhancement in fusion reactor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

DCIF Westerly Granite AE Stress Effect Test (Task 3-1)

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on rectangular Westerly granite blocks (width=depth=4.0", height=2.0"). Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. Several confining stresses were applied bi-axially to the sides of the samples so that the onset of AE activity and the stress applied to the sample were correlated. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission are the animations of the AE locations and graphics displaying the measured temperature-AE activity changes for different stresses.

15 GEOTHERMAL ENERGY↗

Optimal gas cooling with minimal aero-opticaldistortion for next generation high-average-power lasers (Progress report, Year 2)

Next-generation lasers that combine high-peak-power ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required for inertial fusion energy generation, laser-based particle acceleration, and to generate compact secondary x- and 𝛾-ray radiation sources, among others. The combination of long gain length with high surface-to-volume ratio to remove residual heat makes gas-cooled multi-slab amplifier heads an inherently aperture- and average power scalable technology that enables this new class of solid-state lasers, and their thermal management becomes the most pressing technical challenge. As the index-of refraction depends on the gas density, heat removal from the slab surfaces unavoidably entails scattering of propagated light from regions of high temperature fluctuations. The requirement to maximize convective heat extraction from the gain medium under the constraint of minimum optical aberration of the beam renders amplifier slab cooling a technological challenge at the intersection of aero-optics, fluid-mechanics and heat transfer. The goal of this research is to leverage computational fluid dynamics and aero optics simulations of different levels of fidelity to devise a numerical modeling and optimization framework for gas-cooled multi-slab amplifiers. The project will be conducted in close collaboration with the Advanced Photon Technologies Group at Lawrence Livermore National Laboratory, where a gas-cooled test stand for laser materials and thermal management structures will be developed and installed. The final goal of the collaborative effort is to manufacture and benchmark a physical prototype of an numerically optimized amplifier head design. Measurement data on solid-state and thermo-optical distortions will be used for the validation of the numerical models. The key technical challenge in this multi-objective design problem is that of balancing optimal heat removal with minimal optical distortion. To facilitate computationally efficient design optimization and, at the same time, deepen our basic understanding of the interaction of light with turbulence, a complementary study that combines high and low-fidelity flow simulations and aero-optical models is proposed. Along the lines of these two objectives and solution strategies, the project is organized into two thrusts.

42 ENGINEERING↗

INL Contributions to Draft HTTF Benchmark Specifications

The High-Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility at Oregon State University designed as a 1/4 length scale model of the Modular High-Temperature Gas-Cooled Reactor 350 MW core (mHTGR-350). In the spring and summer of 2019, several experiments were conducted at HTTF providing a valuable source of gas-cooled reactor thermal hydraulics data. Idaho National Laboratory (INL), Oregon State University, Argonne National Laboratory, and Canadian Nuclear Laboratories have partnered to use this experimental data to develop a gas-cooled reactor thermal hydraulics benchmark led by INL under the auspices of the Advanced Reactor Technologies (ART) program. This report provides some context on the benchmark, HTTF, and previous Reactor Excursions and Leak Analysis Program (RELAP)5-3D modeling of HTTF. It also provides a draft of the benchmark specifications for the Depressurized Conduction Cooldown problem, which is the INL-led benchmark problem.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surface Heater Fabrication Using Micro-Lithography for Transpiration Cooling Heat Transfer Coefficient Measurements

Abstract Transpiration cooling is able to provide more uniform coolant coverage than film cooling to effectively protect the component surface from contacting the hot gas. Due to numerous coolant ejection outlets within a small area at the target surface, the experimental thermo-fluid investigation on transpiration cooling becomes a significant challenge. Two classic methods to investigate film cooling, the steady-state foil heater method and the transient thermography technique, fail for transpiration cooling because the foil heater would block numerous coolant outlets, and the semi-infinite solid conduction model no longer holds for porous plates. In this study, a micro-lithography method to fabricate a silver coil pattern on top of the additively manufactured polymer porous media as the surface heater was proposed. The circuit was deliberately designed to cover the solid surface in a combination of series connection, and parallel connection to ensure the power in each unit cell area at the target surface was identical. With uniform heat flux generation, the steady-state tests were conducted to obtain distributions of a pair of parameters, adiabatic cooling effectiveness, and heat transfer coefficient (HTC). The results showed that the adiabatic cooling effectiveness could reach 0.65 with a blowing ratio lower than 0.5. Meanwhile, the heat transfer coefficient ratio (hf/h0) of transpiration cooling was close to 1 with a small blowing ratio at 0.125. A higher HTC ratio was observed for smaller pitch-to-diameter cases due to more turbulence intensity generated at the target surface.

Engineering↗

Cost optimization of high recovery single stage gap membrane distillation

Estimating the cost of membrane distillation (MD) processes at scale is confounded by the vast array of possible process configurations, module configurations, and operating conditions and the extreme sensitivity of MD costs to these parameters. This work develops a comprehensive MD cost optimization framework for minimizing the levelized cost of water (LCOW) as a function of feed salinity and temperature. Our single stage gap MD model fully captures solution properties, heat transfer, and mass transfer relationships in the modules to determine the cost optimal design as a function of multiple decision variables, including process configuration (feed location and connectivity between the hot and cold-side), the gap type (air, permeate, conductive), equipment sizes (membrane, heater, chiller, and heat exchanger units), and operating conditions (flow rates, hot and cold side temperatures, and heating and cooling duties). We estimate that the minimum LCOW of conductive gap MD ranges between $\$$10 and $\$$16 per m 3 for feed salinities of 25 g/L to 200 g/L and water recoveries of 30%–75%. Further, we update several heuristic assumptions for cost optimal system operation, including: increased thermal conductivity of the gap decreases system costs; cost optimal MD operates at the highest allowable temperature; and the LCOW is a strong function of brine salinity. Finally, we find that improving membrane properties and lowering heating and cooling costs will provide only modest reductions in costs (<25%).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

HTTF Benchmarking Activities in FY 2023

This report describes the work conducted in FY23 within the High Temperature Gas-Cooled Reactor (HTGR) Applications Drivers activity under the Multiphysics Applications technical area in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program within DOE-NE. The focus of this past year’s activity was on the OECD/NEA thermal hydraulic benchmark for high temperature gas-cooled reactors using HTTF data (HTGR T/H). The activities focus on code-to-code comparisons for two benchmark problems: (1) Depressurized Conduction Cooldown using SAM, and (2) Lower Plenum Mixing using Nek5000/RS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NDMAS System and Process Description

The U. S. Department of Energy (DOE) has made a significant investment in research to develop the next generation of reactor technologies as well as to improve the performance and lengthen the life cycle of existing nuclear reactors. Data collected to demonstrate new concepts may also be used in the future to support licensing of these technologies. Provenance of these data must be preserved. The Nuclear Data Management and Analysis System (NDMAS) was established to manage and preserve data collected by fuels and materials research conducted by the high-temperature, gas-cooled reactor program. The scope of NDMAS is expanding to include other nuclear research programs that have the shared need to preserve the provenance of research data. Nuclear research funded by DOE is conducted by Idaho National Laboratory (INL), universities, other national laboratories, foreign research partners, and private companies. This research will generate a large amount of data from a variety of sources over a period of many years. Managing the data generated by the research and development projects presents a significant challenge for retaining data integrity and availability.

Evaluation of Heat Transfer Enhancement on Rotational Gas Turbine Blade Internal Cooling Channel With Dimpled Surface

Abstract The present investigation represents the rotational effect on gas turbine blade internal cooling with a uniform heat flux of 2000 W/m2 at the bottom wall. The experiment was conducted with three different rpms, such as 300 rpm, 600 rpm, and 900 rpm, with Reynolds number (Re) ranging from 6000 to 50,000 with a two-pass cooling channel. The numerical investigation was conducted with the large eddy simulation (LES) technique to understand the rotational flow behavior of the cooling channel. Four distinct arrangements of dimpled cooling channel surfaces were considered with two different dimple shapes, i.e., partial spherical and leaf. It is found that the rotation effect, dimple arrangement, and design have significant influences on heat transfer. Results indicated that the partial spherical 1-row dimpled surface experienced the highest heat transfer coefficient and pressure drop. In contrast, the leaf-shaped dimpled cooling channel experienced the highest thermal efficiency.

Energy & Fuels↗

Community Geothermal: Borefield Design, Thermal Conductivity, and Subsurface Modeling Data - Chicago, IL

This dataset encompasses the development of a geothermal energy system for the West Woodlawn neighborhood in Chicago, Illinois. This project is part of a broader initiative to design and deploy geothermal heating and cooling systems at a community scale. The dataset includes thermal conductivity test results, calculations for borehole sizing based on the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) method, as well as simulated thermal loads based on actual energy usage from individual buildings. Also provided here are files used for numerical modeling via COMSOL Multiphysics to simulate borefield design and subsurface thermal behavior. Two manuscripts are attached, which outline the broad objectives of the project and a description of the numerical modeling methodology and results.

15 GEOTHERMAL ENERGY↗