Search NASA⌕ Search

SEARCH · Search NASA

Results for “conductive liquid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Long-Wavelength Rupturing Instability in Surface-Tension-Driven Benard Convection

A liquid layer with a free upper surface and heated from below is subject to thermocapillary-induced convective instabilities. We use very thin liquid layers (0.01 cm) to significantly reduce buoyancy effects and simulate Marangoni convection in microgravity. We observe thermocapillary-driven convection in two qualitatively different modes, short-wavelength Benard hexagonal convection cells and a long-wavelength interfacial rupturing mode. We focus on the long-wavelength mode and present experimental observations and theoretical analyses of the long-wavelength instability. Depending on the depths and thermal conductivities of the liquid and the gas above it, the interface can rupture downwards and form a dry spot or rupture upwards and form a high spot. Linear stability theory gives good agreement to the experimental measurements of onset as long as sidewall effects are taken into account. Nonlinear theory correctly predicts the subcritical nature of the bifurcation and the selection between the dry spot and high spots.

Swift, J. B.↗

Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

Source record↗

Feasibility study for the Cryogenic Orbital Nitrogen Experiment (CONE)

An improved understanding of low gravity subcritical cryogenic fluid behavior is critical for the continued development of space based systems. Although early experimental programs provided some fundamental understanding of zero gravity cryogenic fluid behavior, more extensive flight data are required to design space based cryogenic liquid storage and transfer systems with confidence. As NASA's mission concepts evolve, the demand for optimized in-space cryogenic systems is increasing. Cryogenic Orbital Nitrogen Experiment (CONE) is an attached shuttle payload experiment designed to address major technological issues associated with on-orbit storage and supply of cryogenic liquids. During its 7 day mission, CONE will conduct experiments and technology demonstrations in active and passive pressure control, stratification and mixing, liquid delivery and expulsion efficiency, and pressurant bottle recharge. These experiments, conducted with liquid nitrogen as the test fluid, will substantially extend the existing low gravity fluid data base and will provide future system designers with vital performance data from an orbital environment.

Bell, R. S.↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Cryogenic Gellant and Fuel Formulation for Metallized Gelled Propellants: Hydrocarbons and Hydrogen with Aluminum

An experimental program to determine the viability of nanoparticulate gellant materials for gelled hydrocarbons and gelled liquid hydrogen was conducted. The gellants included alkoxides (BTMSE and BTMSH) and silica-based materials. Hexane, ethane, propane and hydrogen were gelled with the newly-formulated materials and their rheological properties were determined: shear stress versus shear rate and their attendant viscosities. Metallized hexane with aluminum particles was also rheologically characterized. The propellant and gellant formulations were selected for the very high surface area and relatively-high energy content of the gellants. These new gellants can therefore improve rocket engine specific impulse over that obtained with traditional cryogenic-fuel gellant materials silicon dioxide, frozen methane, or frozen ethane particles. Significant reductions in the total mass of the gellant were enabled in the fuels. In gelled liquid hydrogen, the total mass of gellant was reduced from 10-40 wt percent of frozen hydrocarbon particles to less that 8 wt percent with the alkoxide.

Wong, Wing↗

Testing the Effects of Helium Pressurant on Thermodynamic Vent System Performance with Liquid Hydrogen

In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1

Flachbart, R. H.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Toward Accurate Thermal Modeling of Phase Change Material Based Photonic Devices

Reconfigurable or programmable photonic devices are rapidly growing and have become an integral part of many optical systems. The ability to selectively modulate electromagnetic waves through electrical stimuli is crucial in the advancement of a variety of applications from data communication and computing devices to environmental science and space explorations. Chalcogenide-based phase change materials (PCMs) are one of the most promising material candidates for reconfigurable photonics due to their large optical contrast between their different solid-state structural phases. Although significant efforts have been devoted to accurate simulation of PCM-based devices, in this paper, we highlight three important aspects which have often evaded prior models yet having significant impacts on the thermal and phase transition behavior of these devices: the enthalpy of fusion, the heat capacity change upon glass transition, as well as the thermal conductivity of liquid-phase PCMs. We further investigated the important topic of switching energy scaling in PCM devices, which also helps explain why the three above-mentioned effects have long been overlooked in electronic PCM memories but only become important in photonics. Our findings offer insight to facilitate accurate modeling of PCM-based photonic devices and can inform the development of more efficient reconfigurable optics.

Phase change materials↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Coupling Online Conductivity with Offline Ion Chromatography Measurements using the Particle-into-Liquid Sampler

A particle-into-liquid sampler has been combined with a flow through conductivity cell to provide a continuous, non-destructive, online measurement in support of offline ion chromatography analysis. The conductivity measurement provides a rapid assessment of the total ion concentration augmenting the slower batch data from the offline analysis and is developed primarily to assist airborne measurements, where fast time response is essential. A model of the conductivity was developed for measured ions and excellent closure is derived for laboratory-generated aerosols. The PILS-conductivity measurement was extensively tested during the NASA Cloud, Aerosol and Monsoon Processes: Philippines Experiment (CAMP2Ex) across nineteen research flights and the conductivity data was found to augment the temporal capability of the PILS instrument for assessing ionic species, allowing sub-minute variability to be resolved. Through the sampling of a diverse range of ambient aerosol, including biomass burning, fresh and aged urban pollution, the conductivity measurement offered additional useful information to untangle the composition of complex aerosol mixtures, specifically for assessing acidic aerosol conditions.

Ewan Colin Crosbie↗

Mixing and transient interface condensation of a liquid hydrogen tank

Experiments were conducted to investigate the effect of axial jet-induced mixing on the pressure reduction of a thermally stratified liquid hydrogen tank. The tank was nearly cylindrical, having a volume of about 0.144 cu m with 0.559 m in diameter and 0.711 m long. A mixer/pump unit, which had a jet nozzle outlet of 0.0221 m in diameter was located 0.178 m from the tank bottom and was installed inside the tank to generate the axial jet mixing and tank fluid circulation. The liquid fill and jet flow rate ranged from 42 to 85 percent (by volume) and 0.409 to 2.43 cu m/hr, respectively. Mixing tests began with the tank pressure ranging from 187.5 to 238.5 kPa at which the thermal stratification results in 4.9 to 6.2 K liquid sub cooling. The mixing time and transient vapor condensation rate at the liquid-vapor interface are determined. Two mixing time correlations, based on the thermal equilibrium and pressure equilibrium, are developed. Both mixing time correlations are expressed as functions of system and buoyancy parameters and compared well with other experimental data. The steady state condensation rate correlation of Sonin et al. based on steam-water data is modified and expressed as a function of jet subcooling. The limited liquid hydrogen data of the present study shows that the modified steady state condensation rate correlation may be used to predict the transient condensation rate in a mixing process if the instantaneous values of jet sub cooling and turbulence intensity at the interface are employed.

Lin, C. S.↗

Mixing and transient interface condensation of a liquid hydrogen tank

Experiments were conducted to investigate the effect of axial jet-induced mixing on the pressure reduction of a thermally stratified liquid hydrogen tank. The tank was nearly cylindrical, having a volume of about 0.144 cu m with 0.559 m in diameter and 0.711 m length. A mixer/pump unit, which had a jet nozzle outlet of 0.0221 m in diameter was located 0.178 m from the tank bottom and was installed inside the tank to generate the axial jet mixing and tank fluid circulation. Mixing tests began with the tank pressures at which the thermal stratification results in 4.9-6.2 K liquid subcooling. The mixing time and transient vapor condensation rate at the liquid-vapor interface are determined. Two mixing time correlations, based on the thermal equilibrium and pressure equilibrium, are developed and expressed as functions of system and buoyancy parameters. The limited liquid hydrogen data of the present study shows that the modified steady state condensation rate correlation may be used to predict the transient condensation rate in a mixing process if the instantaneous values of jet sub cooling and turbulence intensity at the interface are employed.

Lin, C. S.↗

Wicking of liquids in screens

An investigation was conducted to determine the magnitude of the wicking rates of liquids in various screens. Evaluation of the parameters characterizing the wicking process resulted in the development of an expression which defined the wicking velocity in terms of screen and system geometry, liquid properties, and gravitational effects. Experiment data obtained both in normal gravity and in weightlessness demonstrated that the model successfully predicted the functional relation of the liquid properties and the distance from the liquid source to the wicking velocity. Because the pore geometry in the screens was complex, several screen geometric parameters were lumped into a single constant which was determined experimentally for each screen.

Symons, E. P.↗

Experiments on Nucleation in Different Flow Regimes

The vast majority of metallic engineering materials are solidified from the liquid phase. Understanding the solidification process is essential to control microstructure, which in turn, determines the properties of materials. The genesis of solidification is nucleation, where the first stable solid forms from the liquid phase. Nucleation kinetics determine the degree of undercooling and phase selection. As such, it is important to understand nucleation phenomena in order to control solidification or glass formation in metals and alloys. Early experiments in nucleation kinetics were accomplished by droplet dispersion methods. Dilitometry was used by Turnbull and others, and more recently differential thermal analysis and differential scanning calorimetry have been used for kinetic studies. These techniques have enjoyed success; however, there are difficulties with these experiments. Since materials are dispersed in a medium, the character of the emulsion/metal interface affects the nucleation behavior. Statistics are derived from the large number of particles observed in a single experiment, but dispersions have a finite size distribution which adds to the uncertainty of the kinetic determinations. Even though temperature can be controlled quite well before the onset of nucleation, the release of the latent heat of fusion during nucleation of particles complicates the assumption of isothermality during these experiments. Containerless processing has enabled another approach to the study of nucleation kinetics. With levitation techniques it is possible to undercool one sample to nucleation repeatedly in a controlled manner, such that the statistics of the nucleation process can be derived from multiple experiments on a single sample. The authors have fully developed the analysis of nucleation experiments on single samples following the suggestions of Skripov. The advantage of these experiments is that the samples are directly observable. The nucleation temperature can be measured by noncontact optical pyrometry, the mass of the sample is known, and post-processing analysis can be conducted on the sample. The disadvantages are that temperature measurement must have exceptionally high precision, and it is not possible to isolate specific heterogeneous sites as in droplet dispersions. Levitation processing of refractory materials in ultra high vacuum provides an avenue to conduct these kinetic studies on single samples. Two experimental methods have been identified where ultra high vacuum experiments are possible; electrostatic levitation in ground-based experiments and electromagnetic processing in low earth orbit on TEMPUS. Such experiments, reported here, were conducted on zirconium. Liquid zirconium is an excellent solvent and has a high solubility for contaminants contained in the bulk material as well as those contaminants found in the vacuum environment. Oxides, nitrides, and carbides do not exist in the melt, and do not form on the surface of molten zirconium, for the materials and vacuum levels used in this study. Ground-based experiments with electrostatic levitation have shown that the statistical nucleation kinetic experiments are viable and yield results which are consistent with classical nucleation theory. The advantage of low earth orbit experiments is the ability to vary the flow conditions in the liquid prior to nucleation. The put-pose of nucleation experiments in TEMPUS was to examine.

Bayuzick, R. J.↗

Polymerization of perfluorobutadiene

Diisopropyl peroxydicarbonate dissolved in liquid perfluorobutadiene is conducted in a sealed vessel at the autogenous pressure of polymerization. Reaction temperature, ratio of catalyst to monomer, and amount of agitation determine degree of polymerization and product yield.

Newman, J.↗

Development of visual-display aid to air navigation

The design, development, and fabrication of a visual display aid to air navigation are discussed. The display will locate an aircraft on a standard navigational chart when activated by two independent directional signals. The display consists of a radial pattern of electrically conductive line pairs, liquid crystal material contained between the line pairs, and addressing and activating electronics. The application of a voltage to the addressed line pair will cause the liquid crystal to become white in color, thus indicating the direction to the selected VOR station.

Matcovich, T. J.↗

A visual study of radial inward choked flow of liquid nitrogen

A visual study of the radial inward choked flow of liquid nitrogen was conducted. Data and high speed moving pictures were obtained. The study indicated the following: (1) steady radial inward choked flow seems equivalent to steady choked flow through axisymmetric nozzles, (2) transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets, and (3) the critical mass flow rate data for the transient case appear different from those of the steady case.

Hendricks, R. C.↗