Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

Wind Turbine Controller to Mitigate Structural Loads on a Floating Wind Turbine Platform

This paper summarizes the control design work that was performed to optimize the controller of a wind turbine on the WindFloat structure. The WindFloat is a semisubmersible floating platform designed to be a support structure for a multimegawatt power-generating wind turbine. A controller developed for a bottom-fixed wind turbine configuration was modified for use when the turbine is mounted on the WindFloat platform. This results in an efficient platform heel resonance mitigation scheme. In addition, several control modules, designed with a coupled linear model, were added to the fixed-bottom baseline controller. The approach was tested in a fully coupled nonlinear aero-hydro-elastic simulation tool in which wind and wave disturbances were modeled. This testing yielded significant improvements in platform global performance and tower-base bending loading.

17 WIND ENERGY↗

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Improved Moisture Management Technology for Eco-N-Control Fertilizer

Three fertilizer technologies to manage nitrogen (N) release rates in soil dominate the market today: 1) bulk controlled-release technologies, which use the intrinsic solubility properties of a N-organic co-polymer to control N release; 2) barrier-based controlled-release technologies, which use porous polymer or sulfur coatings as a physical barrier to control N release from encapsulated N nutrients; and 3) slow-release technologies, which use enzyme inhibitors to chemically slow down the transformation of N nutrients into ammonia (NH 3 ) or to temporarily reduce populations of bacteria in the soil that are responsible for converting ammonium (NH 4 + ) to highly soluble nitrates. These technologies are expensive and provide only limited control of N-release rates. Also, from another environmental perspective, synthetic polymer coatings do not decompose easily and will accumulate over time with continuous application of fertilizer. For most of the past two decades we have been developing the Eco-N-Control solid-nitride fertilizer technology, a type of bulk controlled-release technology. With Eco-N-Control, solid-nitride compounds weather like a mineral, slowly releasing N at a rate determined by their composition. Testing by an industrial collaborator, however, showed that earlier versions of Eco-N-Control released at 25% of the desired rate when deployed in unsaturated soils. The overall goal of the current project, therefore, was to strengthen our IP position and the potential for licensing of Eco-N-Control solid-nitride fertilizer technology by developing new ways to manage the level of moisture in contact with the fertilizer when applied to soil thereby ensuring the desired N-release rate. We achieved this goal by developing a biodegradable polymer cross-linking approach that substantially improved performance of our patented solid-nitride fertilizer. We found that cross-linking an environmentally friendly and biodegradable polymer with a mixture of solid nitrides, other N-nutrient compounds and other additives offers several advantages: 1) mechanical robustness of fertilizer beads, 2) chemical stability during storage, 3) maintenance of sufficient water content in the vicinity of the nitride, and 4) control of N-release rates. We also updated our N-release testing protocol to more realistically simulate the conditions found in soil. Finally, we filed an invention disclosure record to protect these new aspects of Eco-N-Control technology, which offers a potential way to lower both agricultural and industrial pollution by providing an efficient N-delivery mechanism to plants.

42 ENGINEERING↗

Simulations for Planning of Liquid Hydrogen Spill Test

In order to better understand the complex pooling and vaporization of a liquid hydrogen spill, Sandia National Laboratories is conducting a highly instrumented, controlled experiment inside their Shock Tube Facility. Simulations were run before the experiment to help with the planning of experimental conditions, including sensor placement and cross wind velocity. This paper describes the modeling used in this planning process and its main conclusions. Sierra Suite’s Fuego, an in-house computational fluid dynamics code, was used to simulate a RANS model of a liquid hydrogen spill with five crosswind velocities: 0.45, 0.89, 1.34, 1.79, and 2.24 m/s. Two pool sizes were considered: a diameter of 0.85 m and a diameter of 1.7. A grid resolution study was completed on the smaller pool size with a 1.34 m/s crosswind. A comparison of the length and height of the plume of flammable hydrogen vaporizing from the pool shows that the plume becomes longer and remains closer to the ground with increasing wind speed. The plume reaches the top of the facility only in the 0.45 m/s case. From these results, we concluded that it will be best for the spacing and location of the concentration sensors to be reconfigured for each wind speed during the experiment.

08 HYDROGEN↗

Visual Style Elements in Human–System Interface Design for Nuclear Power Operations: Does Style Affect Performance and Preference?

As the world increasingly adopts renewable and sustainable energy systems, transitionary solutions include nuclear power, which currently provides 20% of the United States’ electricity and is the largest single source of carbon-free electricity generation. Advanced reactors are a critical component of a carbon-free mixed energy portfolio that require careful design of first-of-a-kind control rooms. The application of Human Factors Engineering (HFE) is essential for scientific and iterative testing of novel human–system interface (HSI) concepts to ensure effective, efficient, and safe plant operations. Microworlds are simulators that use simplified physics models and control systems to distill nuclear power operations into essential functions. HFE scientists used the Rancor Microworld Simulator to obtain preference and performance metrics for novel and traditional static HSI design styles. Participants comprised advanced reactor company employees and nuclear industry consultants. A mixture of quantitative and qualitative data was captured. There was a preference for the basic graphical style that included high contrast and traditional color scheme elements. No single HSI design outperformed the others, and the participants did not perform better using their preferred HSI style. We report this experiment is the first in a series of HFE testing for HSIs in advanced reactor control room development. Clear user preferences emerged for elements within static displays. The cutting-edge neumorphic style was the least preferred. Future directions include tests of dynamic displays. HFE is used in evaluating and designing HSI devices that will improve the efficiency and safety of advanced nuclear power operations.

99 GENERAL AND MISCELLANEOUS↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continue to prove themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept currently being explored is the variable-geometry WEC (VGWEC), which aims to add an extra control option to WEC design. VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or torque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. Having control over both the WEC geometry components and the power takeoff (PTO) offers the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable-geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable-geometry modules consist of air-inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines, each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized. The ability to transition between operating condition is expected to increase the sea state operational map and power capacity.

geometry control↗

Advanced Concepts for Dry Storage Cask Thermal-Hydraulic Testing

The purpose of this report is to review technical issues relevant to the performance evaluation of dry storage systems during vacuum drying and long-term storage operations. It also provides updates on experimental components under development that are vital for pursuing advanced studies. Validation of the extent of water removal in a multi-assembly dry storage system using an industrial vacuum drying procedure is needed, as operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters/casks upon completion of vacuum drying can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Therefore, additional information is needed to evaluate the potential impacts of water retention on extended long-term dry storage. A general lack of data and experience modeling the drying process necessitates the testing of advanced concepts focused on the simulation of industrial vacuum drying. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are necessary to provide insight and guidance to the modeling of prototypic systems undergoing drying processes. This report describes the development and testing of waterproof, electrically-heated spent fuel rod simulators as a proof of concept to enable experimental simulation of the entire dewatering and drying process. This report also describes the preliminary development of specially-designed, unheated mock fuel rods for monitoring internal rod pressures and studying water removal from simulated failed fuel rods. A variety of moisture monitoring instrumentation is also being considered and will be downselected for the tracking of dewpoints of gas samples. The effects of cladding oxidation and crud on water retention in dry storage systems can be explored via separate effects tests (SETs) that would measure chemisorbed and physisorbed water content on cladding samples. The concepts listed above will be incorporated into an advanced dry cask simulator with multiple fuel assemblies in order to account for important inter-assembly heat-transfer physics. Plans are described for harvesting up to five full-length 5x5 laterally truncated assemblies from commercial 17x17 PWR skeleton components with the goal of constructing this simulator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept, currently being explored, is hoping to add an extra control option to WEC design is the variable-geometry WEC (VGWEC). These VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or toque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. The opportunities of having control over both the WEC geometry components and the power-take-off (PTO) have the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable geometry modules consist of air inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can be shown to maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized in hopes of increasing the sea state operational map.

geometry control↗

Testing and signal identification for two-sample high-dimensional covariances via multi-level thresholding

The paper considers testing and signal identification for covariance matrices from two populations of marginally sub-Gaussian distributed. A multi-level thresholding procedure is proposed for testing the equality of two high-dimensional covariance matrices, which is designed to detect sparse and faint differences between the covariances. A novel -statistic composition is developed to establish the asymptotic distribution of the thresholding statistics in conjunction with the matrix blocking and the coupling techniques. It is shown that the proposed test is more powerful than the existing tests in detecting sparse and weak signals in covariances. Multiple testing procedures are constructed to discover different covariances and the sub-groups of variables with different covariance structures between the two populations. The proposed procedures are based on the multi-level thresholding test, which are able to control the false discovery proportion () with high power. Simulation experiments and a case study on the returns of the S&P 500 stocks before and after the COVID-19 pandemic are conducted to demonstrate and compare the utilities of the proposed methods.

97 MATHEMATICS AND COMPUTING↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Gravo-aeroelastic scaling of a 13-MW downwind rotor for 20% scale blades

A 105-m, 13-MW two-bladed downwind Segmented Ultralight Morphing Rotor (SUMR-13) blade was gravo-aeroelastically scaled by 20% to a 20.87-m-long demonstrator blade and confirmed through structural ground testing. The subscale model was achieved through geometric scaling and by aeroelastic scaling principles based on operational flapwise deflections combined with rotational and structural frequencies while retaining the turbine tip-speed ratio. In particular, the subscale demonstrator was designed to replicate, as closely as possible, the nondimensional geometry, the ratio of centrifugal to gravitational moments, the tip-speed ratio, and the nondimensional rotation rate. The intent for this demonstrator was to achieve the same nondimensional flapwise blade deflections and dynamics of the full-scale 13-MW rotor. The manufactured SUMR-D blade resulted in less than half of the mass of the conventional two-bladed Controls Advanced Research Turbine (CART2) rotor blade based on scaling and a lower power rating, though with some differences in mass and stiffness from the ideal scaled-down design to meet safety requirements at the test site. To achieve proper scaling, operational pitch control set points were altered to account for the differences by evaluating simulated operation of both the SUMR-13 and SUMR-D rotors. Structural testing of the SUMR-D blade investigated the response to well-defined flapwise loads and indicated that the subscale blade had the appropriate elastic properties needed for both scaling and for safe operational field testing.

17 WIND ENERGY↗

Development of a three-dimensional APOLLO3 neutrons deterministic scheme for the CABRI reactor

CABRI is an experimental reactor to study the fuel behavior during reactivity injection transients. These transients being highly multiphysics, the development of suitable modeling and simulation tools to simulate them is important for the optimization of the tests and the control of the experimental conditions. This paper focuses on the development of an APOLLO3 deterministic core calculation tool dedicated to the CABRI transient analysis. It represents the first stage of the incremental process for the implementation of a multiphysics time-dependent modeling of the CABRI transient. The neutron calculation scheme is based on a classical two-step approach. The first step consists of a 281-energy group calculation flux with the TDT-MOC (Method Of Characteristics) solver for cross-section space and energy (23 groups) collapsing for the CABRI different assembly clusters. The bias on a 2D core neutron calculation due to the self-shielding calculation and collapsing on a restricted pattern are investigated thanks to a comparison with a direct full 2D calculation on a quarter of core. The second step relies on a pin-resolved transport 3D transport core calculation with the SN solver MINARET. A progressive numerical validation process is followed to quantify the calculation biases on reactivity and reaction rates at each step using reference calculations with the stochastic code TRIPOLI4. The next development stage toward a multiphysics scheme will be the implementation of the 3D-kinetics equation resolution and the coupling with a core thermal-hydraulics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking: Preprint

As distributed energy resources play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. The comparison of a distribution system run with fixed feed-in voltage is compared to the closely tied distribution-transmission co-simulation. It is determined that even without advanced voltage controls, the feed-in voltage response of the transmission system shows a lower level of voltage excursions. Therefore, control methods for voltage stability should be benchmarked on realistic transmission and distribution co-simulations for more accurate assessment of voltage profiles.

27 ARPA - Advanced Research Projects Agency-Energy↗