Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Stretchable Mould Interconnect Optimization: Peeling Automation and Carrierless Techniques

The primary bottleneck of the stretchable mold interconnect (SMI) technology is its reliance on carrier boards. These are necessary to handle the meandered circuit during production and to ensure dimensional stability of the flexible circuit board before encapsulation. However, for all the problems it solves, it also introduces a new major problem by requiring a peeling step – which is difficult to automate. This manuscript aims to present some of the work that went into eliminating this problem, discussing both unsuccessful and functioning methods to tackle this conundrum and some of the experimental work that went into verifying these techniques. First, alterations to the design to simplify peeling are considered, followed by adhesivebased peeling processes and mechanical pin-based systems. Next, masking and structuring of the carrier board adhesive are considered. Finally, two carrierless methods which circumvent the problems are discussed, a two-step process – which cuts temporary support structures after partial encapsulation – and a technique whereby the frame is designed to fail in a controlled manner during the first use of the circuit, creating a carrierless process feasible for high-volume production.

Plovie, Bart↗

Relating Dose Outside the Prostate With Freedom From Failure in the Dutch Trial 68 Gy vs. 78 Gy

Purpose: For prostate cancer patients at risk for subclinical spread of the disease, we investigated whether incidental dose outside the target was associated with tumor control. Methods and Materials: We selected 352 intermediate-risk (mainly T2b-T3a) and high-risk (mainly T3b) patients treated in a randomized trial. Target volume was prostate (68-78 Gy) and seminal vesicles (50-78 Gy). Failure (clinical or biochemical) was evaluated at 4 years. To compare three-dimensional dose distributions, an automated mapping procedure was introduced. Between patients, these maps provide an approximate identification of corresponding anatomical locations. Maps of the dose difference between patients with and without failure were constructed. Univariate and multivariate analyses were performed including the dose in selected points. Results: Dose differences were mainly found in the obturatorial region for the high-risk patients, and in the presacral region for the intermediate risk group (>7 Gy, p < 0.01). Univariate hazard ratios per 10 Gy for selected dose points were 0.83 (p = 0.01, obturatorial) and 0.72 (p = 0.002, presacral). These hazard ratios were stable under multivariate analysis correcting for established prognostic factors, hospital, and dose to the prostate. Conclusions: Patients without failure have received on average a higher dose to regions where regional cancer spread could be expected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Target Volume D95 and Mean Dose Should Be Considered for Optimal Local Control for Stereotactic Ablative Radiation Therapy

Purpose: To identify the optimal dose parameters predictive for local/lobar control after stereotactic ablative radiation therapy (SABR) in early-stage non-small cell lung cancer (NSCLC). Methods and Materials: This study encompassed a total of 1092 patients (1200 lesions) with NSCLC of clinical stage T1-T2 N0M0 who were treated with SABR of 50 Gy in 4 fractions or 70 Gy in 10 fractions, depending on tumor location/size, using computed tomography-based heterogeneity corrections and a convolution superposition calculation algorithm. Patients were monitored by chest CT or positron emission tomography/CT and/or biopsy after SABR. Factors predicting local/lobar recurrence (LR) were determined by competing risk multivariate analysis. Continuous variables were divided into 2 subgroups at cutoff values identified by receiver operating characteristic curves. Results: At a median follow-up time of 31.7 months (interquartile range, 14.8-51.3 months), the 5-year time to local recurrence within the same lobe and overall survival rates were 93.8% and 44.8%, respectively. Total cumulative number of patients experiencing LR was 40 (3.7%), occurring at a median time of 14.4 months (range, 4.8-46 months). Using multivariate competing risk analysis, independent predictive factors for LR after SABR were minimum biologically effective dose (BED{sub 10}) to 95% of planning target volume (PTVD95 BED{sub 10}) ≤86 Gy (corresponding to PTV D95 physics dose of 42 Gy in 4 fractions or 55 Gy in 10 fractions) and gross tumor volume ≥8.3 cm{sup 3}. The PTVmean BED{sub 10} was highly correlated with PTVD95 BED{sub 10.} In univariate analysis, a cutoff of 130 Gy for PTVmean BED{sub 10} (corresponding to PTVmean physics dose of 55 Gy in 4 fractions or 75 Gy in 10 fractions) was also significantly associated with LR. Conclusions: In addition to gross tumor volume, higher radiation dose delivered to the PTV predicts for better local/lobar control. We recommend that both PTVD95 BED{sub 10} >86 Gy and PTVmean BED{sub 10} >130 Gy should be considered for SABR plan optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Effective Preoperative Three-Dimensional Radiotherapy Target Volume for Extremity Soft Tissue Sarcoma and the Effect of Margin Width on Local Control

Purpose: There is little information on the appropriate three-dimensional (3D) preoperative radiotherapy (XRT) volume for extremity soft-tissue sarcomas (STS). We retrospectively analyzed the pattern of local failure (LF) to help elucidate optimal field design. Methods and Materials: We analyzed the 56 patients who underwent computed tomography-planned XRT for Stage I to III extremity STS between June 2000 and December 2006. Clinical target volume (CTV) included the T1 post-gadolinium-defined gross tumor volume with 1- to 1.5-cm radial and 3.5-cm longitudinal margins. Planning target volume expansion was 5 to 7 mm, and {>=}95% of dose was delivered to the planning target volume. Preoperative XRT was 44 to 50.4 Gy (median, 50). Postoperative boost of 10 to 20 Gy was given to 12 patients (6 with positive and 6 with close margins). Results: Follow-up ranged from 15 to 76 months (median, 41 months). The 5-year local control, freedom from distant metastasis, disease-free survival, and overall survival were 88.5%, 80.0%, 77.5% and 82.8%, respectively. Three patients (all with positive margin) experienced local failure (LF) as first relapse (2 isolated, 1 with distant failure), and 2 additional patients (all with margin<1 mm) had late LF after distant metastasis. The LFs were within the CTV in 3 patients and within and also extending beyond the CTV in 2 patients. Conclusions: These target volume definitions appear to be appropriate for most patients. No local recurrences were observed with surgical margins {>=}1 mm, and it appears that these may be adequate for patients with extremity STS treated with preoperative radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Local Failure With Measures of Dose Insufficiency in the High-Dose Single-Fraction Treatment of Bony Metastases

Purpose: In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials: The minimum doses received by the hottest 100%, 98%, and 95% (D{sub min}, D{sub 98}, and D{sub 95}) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results: With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D{sub min}, D{sub 98}, and D{sub 95} for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D{sub min}, D{sub 98}, and D{sub 95} were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions: The results indicate that D{sub min}, D{sub 98}, and D{sub 95} may be important risk factors for local failure. No local failures in any histology were observed when D{sub min} was >15 Gy, suggesting that this metric may be an important predictor of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of External Boost Volume in Breast-Conserving Therapy on Local Control With Long-Term Follow-Up

Purpose: To determine the effects of boost volume (BV) in relation to margin status and tumor size on the development of local recurrence with breast-conserving therapy. Methods and Materials: Between 1983 and 1995, 1,073 patients with invasive breast cancer underwent 1,101 breast-conserving therapies. Of these 1,101 BCTs, 967 were eligible for analysis. The BV was categorized into tertiles: <66 cm{sup 3} (n = 330), 66-98 cm{sup 3} (n = 326), and >98 cm{sup 3} (n = 311). The median follow-up was 141 months. Separate analyses were done for women {<=}40 years and >40 years. Results: No significant difference in local recurrence was shown between the tertiles and the recurrence site. The 15-year local recurrence-free survival rate was 87.9% for the first tertile, 88.7% for the second, and 89% for the third. For women {<=}40 years old, the corresponding 15-year local recurrence-free survival rate was 80%, 74.5%, and 69.2%. For women >40 years old, the corresponding rate was 88.7%, 89.5%, and 90.9%. At 5 years, women >40 years old had significantly more local failures in the first tertile; this difference disappeared with time. A test for trend showed significance at 5 years (p = 0.0105) for positive margins for ductal carcinoma in situ in women >40 years of age. Conclusion: The results of this study have shown that the size of the external BV has no major impact on local control. For women >40 years old, positive margins for ductal carcinoma in situ showed a trend with respect to BV at 5 years. The BV had no influence on local control in the case of positive margins for invasive carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Randomized Controlled Trial of Lorazepam to Reduce Liver Motion in Patients Receiving Upper Abdominal Radiation Therapy

Purpose: Reduction of respiratory motion is desirable to reduce the volume of normal tissues irradiated, to improve concordance of planned and delivered doses, and to improve image guided radiation therapy (IGRT). We hypothesized that pretreatment lorazepam would lead to a measurable reduction of liver motion. Methods and Materials: Thirty-three patients receiving upper abdominal IGRT were recruited to a double-blinded randomized controlled crossover trial. Patients were randomized to 1 of 2 study arms: arm 1 received lorazepam 2 mg by mouth on day 1, followed by placebo 4 to 8 days later; arm 2 received placebo on day 1, followed by lorazepam 4 to 8 days later. After tablet ingestion and daily radiation therapy, amplitude of liver motion was measured on both study days. The primary outcomes were reduction in craniocaudal (CC) liver motion using 4-dimensional kV cone beam computed tomography (CBCT) and the proportion of patients with liver motion ≤5 mm. Secondary endpoints included motion measured with cine magnetic resonance imaging and kV fluoroscopy. Results: Mean relative and absolute reduction in CC amplitude with lorazepam was 21% and 2.5 mm respectively (95% confidence interval [CI] 1.1-3.9, P=.001), as assessed with CBCT. Reduction in CC amplitude to ≤5 mm residual liver motion was seen in 13% (95% CI 1%-25%) of patients receiving lorazepam (vs 10% receiving placebo, P=NS); 65% (95% CI 48%-81%) had reduction in residual CC liver motion to ≤10 mm (vs 52% with placebo, P=NS). Patients with large respiratory movement and patients who took lorazepam ≥60 minutes before imaging had greater reductions in liver CC motion. Mean reductions in liver CC amplitude on magnetic resonance imaging and fluoroscopy were nonsignificant. Conclusions: Lorazepam reduces liver motion in the CC direction; however, average magnitude of reduction is small, and most patients have residual motion >5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication of carbon microcapsules containing silicon nanoparticles-carbon nanotubes nanocomposite by sol-gel method for anode in lithium ion battery

Carbon microcapsules containing silicon nanoparticles (Si NPs)-carbon nanotubes (CNTs) nanocomposite (Si-CNT-C) have been fabricated by a surfactant mediated sol-gel method followed by a carbonization process. Silicon nanoparticles-carbon nanotubes (Si-CNT) nanohybrids were produced by a wet-type beadsmill method. To obtain Si-CNT nanocomposites with spherical morphologies, a silica precursor (tetraethylorthosilicate, TEOS) and polymer (PMMA) mixture was employed as a structure-directing medium. Thus the Si-CNT/Silica-Polymer microspheres were prepared by an acid catalyzed sol-gel method. Then a carbon precursor such as polypyrrole (PPy) was incorporated onto the surfaces of pre-existing Si-CNT/silica-polymer to generate Si-CNT/Silica-Polymer-PPy microspheres. Subsequent thermal treatment of the precursor followed by wet etching of silica produced Si-CNT-C microcapsules. The intermediate silica/polymer must disappear during the carbonization and etching process resulting in the formation of an internal free space. The carbon precursor polymer should transform to carbon shell to encapsulate remaining Si-CNT nanocomposites. Therefore, hollow carbon microcapsules containing Si-CNT nanocomposites could be obtained (Si-CNT-C). The successful fabrication was confirmed by scanning electron microscopy (SEM) and X-ray diffraction (XRD). These final materials were employed for anode performance improvement in lithium ion battery. The cyclic performances of these Si-CNT-C microcapsules were measured with a lithium battery half cell tests. - Graphical Abstract: Carbon microcapsules containing silicon nanoparticles (Si NPs)-carbon nanotubes (CNTs) nanocomposite (Si-CNT-C) have been fabricated by a surfactant mediated sol-gel method. Highlights: > Polymeric microcapsules containing Si-CNT transformed to carbon microcapsules. > Accommodate volume changes of Si NPs during Li ion charge/discharge. > Sizes of microcapsules were controlled by experimental parameters. > Lithium storage capacity and coulombic efficiency were demonstrated. > Use of sol-gel procedure as intermediate reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost Flexible Electrochromic Film for Energy Efficient Buildings

Broad Funding Opportunity Announcement Project: ITN is addressing the high cost of electrochromic windows with a new manufacturing process: roll-to-roll deposition of the film onto flexible plastic surfaces. Production of electrochromic films on plastic requires low processing temperatures and uniform film quality over large surface areas. ITN is overcoming these challenges using its previous experience in growing flexible thin-film solar cells and batteries. By developing sensor-based controls, ITN’s roll-to-roll manufacturing process yields more film over a larger area than traditional film deposition methods. Evaluating deposition processes from a control standpoint ultimately strengthens the ability for ITN to handle unanticipated deviations quickly and efficiently, enabling more consistent large-volume production. The team is currently moving from small-scale prototypes into pilot-scale production to validate roll-to-roll manufacturability and produce scaled prototypes that can be proven in simulated operating conditions. Electrochromic plastic films could also open new markets in building retrofit applications, vastly expanding the potential energy savings.

ARPA-E↗

Thermal treatment of solid residues from WtE units: A review

Highlights: • We review the thermal treatment methods for ashes and residues from WtE plants. • We review the results from extensive laboratory work on vitrification, melting and vaporization of ash. • We analyze the results from the extensive patent literature on thermal treatment. • We review industrial concepts for thermal treatment of ash. - Abstract: Thermal treatment methods of bottom ash, fly ash and various types of APC (air pollution control) residues from waste-to-energy plants can be used to obtain environmentally stable material. The thermal treatment processes are meant to reduce the leachability of harmful residue constituents, destroy toxic organic compounds, reduce residue volume, and produce material suitable for utilization. Fly ash and APC residues often have high levels of soluble salts, particularly chlorides, metals such as cadmium, lead, copper and zinc, and trace levels of organic pollutants such as dioxins and furans. Different thermal treatment methods can be used to either decompose or stabilize harmful elements and compounds in the ash, or separate them from the ash to get a material that can be safely stored or used as products or raw materials. In the present paper, thermal treatment methods, such as sintering, vitrification, and melting have been reviewed. In addition to a review of the scientific literature, a survey has been made of the extensive patent literature in the field.

54 ENVIRONMENTAL SCIENCES↗

A Feasibility Study on the Role of Ultrasound Imaging of Bladder Volume as a Method to Improve Concordance of Bladder Filling Status on Treatment with Simulation

Accurate positioning of the prostate is of paramount importance to ensure optimal target coverage and normal tissue sparing in stereotactic ablative body radiation when large doses per fraction are delivered with tight margins around the prostate. Bladder and rectal filling play an important part in controlling the accuracy of a patient's setup and therefore the overall toxicities and outcomes. The aim of this study was to establish the value of characterizing patients' bladder filling kinetics at the time of simulation with ultrasound scans so that a predictive model can be used to ensure that a bladder volume at treatment would match at simulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conformal Brachytherapy Planning for Cervical Cancer Using Transabdominal Ultrasound

Purpose: To determine if transabdominal ultrasound (US) can be used for conformal brachytherapy in cervical cancer patients. Materials and Methods: Seventy-one patients with locoregionally advanced cervix cancer treated with chemoradiation and brachytherapy were included in this study. The protocol consisted of US-assisted tandem insertion and conformal US-based planning. Orthogonal films for applicator reconstruction were also taken. A standard plan was modified to suit the US-based volume and treatment was delivered. The patient then underwent a magnetic resonance imaging (MRI) scan with the applicators in situ. Retrospectively, individual standard (STD), US, and MRI plans were extrapolated for five fractions and superimposed onto the two-dimensional sagittal MRI images for comparison. Doses to Point A, target volume, International Commission on Radiation Units and Measurements (ICRU) 38 bladder and rectal points, and individualized bowel points were calculated on original implant geometry on Plato for each planning method. Results: STD (high-dose-rate) plans reported higher doses to Point A, target volume, ICRU 38 bladder and rectal points, and individualized bowel point compared with US and MRI plans. There was a statistically significant difference between standard plans and image-based plans-STD vs. US, STD vs. MRI, and STD vs. Final-having consistent (p {<=} 0.001) respectively for target volume, Point A, ICRU 38 bladder, and bowel point. US plan assessed on two-dimensional MRI image was comparable for target volume (p = 0.11), rectal point (p = 0.8), and vaginal mucosa (p = 0.19). Local control was 90%. Late bowel morbidity (G3, G4) was <2%. Conclusions: Transabdominal ultrasound offers an accurate, quick, accessible, and cost-effective method of conformal brachytherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-FG-202-02: Exploration of High-Resolution Quantitative Ultrasonic Micro-Vascular Imaging for Early Assessment of Radiotherapy Tumor Response

Purpose: Currently, we cannot predict an individual patient’s response to a given radiotherapy which normally is not detected for weeks to months post-treatment. As a result, precious time is wasted for patients with unresponsive tumors who could have switched to an alternative treatment much earlier. Presently, no early treatment response detection method exists that is effective, low-cost, non-invasive, and safe. We hypothesize that changes in tumor microvasculature predict tumor response to radiotherapy earlier than tumor volume changes. Recent radiobiology research suggests tumors undergo vascular remodeling in response to radiation well before manifesting changes in tumor volume. We propose monitoring tumor microvasculature post-radiation using Acoustic Angiography (AA), a novel ultrasound imaging modality developed and patented in-house. In this study, we investigate whether changes in tumor microvasculature, measured using AA, can be an early indicator of high-dose radiotherapy success, compared to changes in tumor volume. Methods: Fibrosarcoma xenograft tumor tissue was subcutaneously implanted into rodent flanks (N=10). Animal tumors (N=8) were irradiated with a single treatment of 15Gy using a clinical LINAC at 100SSD and 2×2cm field size. Two untreated rats were left as tumor controls. AA imaging was performed immediately posttreatment and every third day thereafter for 30 days, or until tumors disappeared. Tumor volumes and vascular densities were measured from anatomical b-mode ultrasound and AA images, respectively. Results: Statistical differences in vascular density between treatment responders and non-responders were observed on Day 10 (p=0.005), whereas statistical differences in tumor volume were not observed until Day 19 (p=0.02). Conclusions: Tumor vascularity differences may be observed substantially earlier than differences in tumor size. In addition, significant early increases in vascular density were observed in non-responding tumors. This data is consistent with a similar study we completed using the same tumor and animal models (N=10) at 20Gy. The project described was supported by the National Center for Advancing Translational Sciences (NCATS), National Institutes of Health, through Grant Award Number UL1TR001111. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

60 APPLIED LIFE SCIENCES↗

Potential method for measurement of CO2 leakage from underground sequestration fields using radioactive tracers

Reduction of anthropogenic carbon dioxide (CO2) release to the environment is a pressing challenge that should be addressed to avert the potential devastating effects of global warming. Within the United States, the most abundant sources of CO2 emissions are those generate from coal- or gas-fired power plants; one method to control CO2 emissions is to sequester it in deep underground geological formations. From integrated assessment models the overall leakage rates from these storage locations must be less than 0.1% of stored volume per year for long-term control. The ability to detect and characterize nascent leaks, in conjunction with subsequent remediation efforts, will significantly decrease the amount of CO2 released back into the environment. Because potential leakage pathways are not necessarily known a priori, onsite monitoring must be performed; the monitoring region in the vicinity of a CO2 injection well may be as large as 100 km2, which represents the estimated size of a supercritical CO2 bubble that would form under typical injection scenarios. By spiking the injected CO2 with a radiological or stable isotope tracer, it will be possible to detect ground leaks from the sequestered CO2 using fewer sampling stations, with greater accuracy than would be possible using simple CO2 sensors. The relative merits of various sorbent materials, radiological and stable isotope tracers, detection methods and potential interferences will be discussed.

01 COAL, LIGNITE, AND PEAT↗

In Vivo{sup 1}H Magnetic Resonance Spectroscopy of Lactate in Patients With Stage IV Head and Neck Squamous Cell Carcinoma

Purpose: To investigate in vivo{sup 1}H magnetic resonance spectroscopy imaging of lactate for assessing tumor hypoxia in head and neck cancers and to determine its utility in predicting the response and outcomes. Methods and Materials: Volume-localized lactate-edited {sup 1}H magnetic resonance spectroscopy at 1.5 T was performed in vivo on involved neck nodes and control subcutaneous tissues in 36 patients with Stage IV head and neck cancer. The signal intensities (SIs) of lactate, choline, and creatine and the choline/creatine ratio were measured. The tumor partial pressure of oxygen (pO{sub 2}) was obtained in the same lymph node before MRS. Patients were treated with either two cycles of induction chemotherapy (tirapazamine, cisplatin, 5-fluorouracil) followed by simultaneous chemoradiotherapy or the same regimen without tirapazamine. The lactate SI and the choline/creatine ratio correlated with the tumor pO{sub 2}, nodal response, and locoregional control. Results: The lactate SI was greater for the involved nodes (median, 0.25) than for the subcutaneous tissue (median, 0.04; p = 0.07). No significant correlation was found between the lactate SI and tumor pO{sub 2} (mean, 0.46 {+-} 0.10 for hypoxic nodes [pO{sub 2} {<=}10 mm Hg, n = 15] vs. 0.36 {+-} 0.07 for nonhypoxic nodes [pO{sub 2} >10 mm Hg, n = 21], p = 0.44). A significant correlation was found between the choline/creatine ratios and tumor pO{sub 2} (mean, 2.74 {+-} 0.34 for hypoxic nodes vs. 1.78 {+-} 0.31 for nonhypoxic nodes, p = 0.02). No correlation was found between the lactate SI and the complete nodal response (p = 0.52) or locoregional control rates. Conclusions: The lactate SI did not correlate with tumor pO{sub 2}, treatment response, or locoregional control. Additional research is needed to refine this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without the need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.

60 APPLIED LIFE SCIENCES↗

SU-E-T-436: Fluence-Based Trajectory Optimization for Non-Coplanar VMAT

Purpose: To investigate a fluence-based trajectory optimization technique for non-coplanar VMAT for brain cancer. Methods: Single-arc non-coplanar VMAT trajectories were determined using a heuristic technique for five patients. Organ at risk (OAR) volume intersected during raytracing was minimized for two cases: absolute volume and the sum of relative volumes weighted by OAR importance. These trajectories and coplanar VMAT formed starting points for the fluence-based optimization method. Iterative least squares optimization was performed on control points 24° apart in gantry rotation. Optimization minimized the root-mean-square (RMS) deviation of PTV dose from the prescription (relative importance 100), maximum dose to the brainstem (10), optic chiasm (5), globes (5) and optic nerves (5), plus mean dose to the lenses (5), hippocampi (3), temporal lobes (2), cochleae (1) and brain excluding other regions of interest (1). Control point couch rotations were varied in steps of up to 10° and accepted if the cost function improved. Final treatment plans were optimized with the same objectives in an in-house planning system and evaluated using a composite metric - the sum of optimization metrics weighted by importance. Results: The composite metric decreased with fluence-based optimization in 14 of the 15 plans. In the remaining case its overall value, and the PTV and OAR components, were unchanged but the balance of OAR sparing differed. PTV RMS deviation was improved in 13 cases and unchanged in two. The OAR component was reduced in 13 plans. In one case the OAR component increased but the composite metric decreased - a 4 Gy increase in OAR metrics was balanced by a reduction in PTV RMS deviation from 2.8% to 2.6%. Conclusion: Fluence-based trajectory optimization improved plan quality as defined by the composite metric. While dose differences were case specific, fluence-based optimization improved both PTV and OAR dosimetry in 80% of cases.

60 APPLIED LIFE SCIENCES↗

DEVELOPMENT OF A SCALABLE THERMOMECHANICAL PROCESS (TMP) FOR THICK BAINITIC ARMOR STEEL

A bainite phase-based alloy and associated thermomechanical process were developed to produce (2.5 to over 5 cm) thick armor-grade steel with uniform through-thickness high hardness and strength. The alloy composition and the final-critical (austenite to bainite) isothermal transformation step were specifically designed to utilize a simple and versatile air-cool/quench method to keep a low upfront capital cost and to provide the ability to continuously control the cooling rate in real time, in order to produce maximum volume fraction of bainite phase, and promote uniformly distributed strength and hardness. Final thickness of 2.5 cm and 5.7 cm steel plates were fabricated for characterization, testing and evaluation and found to possess uniform through-thickness hardness between 53 to 55 HRC and dynamic compressive strength of up to 2 GPa.

36 MATERIALS SCIENCE↗