Search NASA⌕ Search

SEARCH · Search NASA

Results for “counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Counting digital filters

Several embodiments of a counting digital filter of the non-recursive type are disclosed. In each embodiment two registers, at least one of which is a shift register, are included. The shift register received j sub x-bit data input words bit by bit. The kth data word is represented by the integer.

Zohar, S.↗

Effects of the space flight environment on man's immune system. II - Lymphocyte counts and reactivity.

The present studies were undertaken to assess the effects of the environment of space flights on the cellular division of the human immune system. Peripheral blood absolute lymphocyte counts were determined at various preflight and postflight intervals for the 21 crewmen of Apollo Missions 7-13. Mean lymphocyte numbers tended to exhibit a delayed significant but fluctuating increase shortly after recovery, although a variety of responses was seen in individual astronauts. The in vitro reactivity of lymphocytes, reflected by RNA and DNA synthesis rates by unstimulated and PHA-stimulated lymphocytes tissue-cultured preflight and postflight from the same participants, was found to remain within previously established normal ranges. These results indicate that functional integrity of cellular immune potential as reflected by in vitro techniques is maintained during this spaceflight experience.

Fischer, G. L.↗

The counting recursive digital filter.

Analysis of the bit-level operations involved in the convolutions realizing recursive digital filters leads to hardware designs of such filters based on the operation of counting. Various designs realizing both the canonic and 'direct' forms are presented with particular emphasis on low-cost low-speed high-flexibility machines.

Zohar, S.↗

Stability of fringe counting interferometers

Two configurations of an automatic bidirectional, fringe-counting corner-cube interferometer are compared. They differ only in the method of quadrature phase introduction. The one using polarization coding has good phase stability at optical path differences as large as 955 mm, the one using adjacent beams has such poor phase stability as to render it useless at path differences greater than 700 mm. A useful well-defined alignment procedure is given for the corner-cube interferometer.

Edgerton, J. W.↗

Method of detecting and counting bacteria

An improved method is provided for determining bacterial levels, especially in samples of aqueous physiological fluids. The method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of nonbacterial ATP. The bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay. A concentration technique is included to make the method more sensitive. It is particularly useful where the fluid to be measured contains an unknown or low bacteria count.

Picciolo, G. L.↗

Volume Fraction Determination in Cast Superalloys and DS Eutectic Alloys by a New Practice for Manual Point Counting

Volume fraction of a constituent or phase was estimated in six specimens of conventional and DS-eutectic superalloys, using ASTM E562-76, a new standard recommended practice for determining volume fraction by systematic manual point count. Volume fractions determined ranged from 0.086 to 0.36, and with one exception, the 95 percent relative confidence limits were approximately 10 percent of the determined volume fractions. Since the confidence-limit goal of 10 percent, which had been arbitrarily chosen previously, was achieved in all but one case, this application of the new practice was considered successful.

Andrews, C. W.↗

The intensified charge coupled device as a photon counting imager

Actual and projected performance of an intensified charge coupled device (ICCD) to be used as a photon counting imager will be presented. Effects of tube processing on such important CCD parameters as charge transfer efficiency and dark current are discussed.

Williams, J. T.↗

Two-dimensional photon-counting detector arrays based on microchannel array plates

The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.

Timothy, J. G.↗

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

Star counts and visual extinctions in dark nebulae

Application of star count techniques to the determination of visual extinctions in compact, fairly high-extinction dark nebulae is discussed. Particular attention is devoted to the determination of visual extinctions for a cloud having a possibly anomalous ratio of total to selective extinction. The techniques discussed are illustrated in application at two colors to four well-known compact dust clouds or Bok globules: Barnard 92, B 133, B 134, and B 335. Minimum masses and lower limits to the central extinction of these objects are presented.

Dickman, R. L.↗

Dynamics of erythrocyte count, hemoglobin, and catalase activity in rat blood in hypokinesia, muscular activity and restoration

Tests were conducted to prove that muscular exertion (in this instance swimming) of different duration and intensity, as well as hypodynamia, result in an increase of hemoglobin and number of red blood cells in peripheral blood rats. Catalase activity increased with an increase in the duration of swimming, but only up to 6 hr; with 7-9 hr of swimming as well as in hypodynamia, catalase activity decreased. It was also observed that under hypodynamia as well as in 3, 5 and 6 hr exertion (swimming) the color index of blood decreased. Pressure chamber treatment (for 8 min each day for one week), alternating a 2 min negative pressure up to 35 mm Hg with 1 min positive pressure, increased the erythrocyte count and hemoglobin content.

Taneyeva, G. V.↗

Carbon fiber counting

A method was developed for characterizing the number and lengths of carbon fibers accidentally released by the burning of composite portions of civil aircraft structure in a jet fuel fire after an accident. Representative samplings of carbon fibers collected on transparent sticky film were counted from photographic enlargements with a computer aided technique which also provided fiber lengths.

Pride, R. A.↗

Low-velocity impact craters in ice and ice-saturated sand with implications for Martian crater count ages

The paper reports on a series of low-velocity impact experiments performed in ice and ice-saturated sand. It is found that crater diameters in ice-saturated sand were about 2 times larger than in the same energy and velocity range in competent blocks of granite, basalt and cement, while craters in ice were 3 times larger. It is shown that if this dependence of crater size on strength persists to large hypervelocity impact craters, then surface of geologic units composed of ice or ice-saturated soil would have greater crater count ages than rocky surfaces with identical influx histories. Among the conclusions are that Martian impact crater energy versus diameter scaling may also be a function of latitude.

Croft, S. K.↗

Star counts as an indicator of galactic structure and quasar evolution

A detailed model of the stellar content of the Galaxy is described briefly. Illustrative applications of the model are made, using existing data, to indicate how star counts can be used to determine some parameters of galactic structure, to detect a massive (stellar) halo, and to constrain models of quasar evolution.

Bahcall, J. N.↗

High sensitivity pulse-counting mass spectrometer system for noble gas analysis

A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.

Hohenberg, C. M.↗

Role of the doubly stochastic Neyman type-A and Thomas counting distributions in photon detection

The sums of Meyman type-A and Thomas random variables are shown to retain their form under the constant multiplication parameter constraint. The conditions under which the two random variables converge in distribution to the fixed multiplicative Poisson, and to the Gaussian, are presented. It is shown that the latter result is important, in that it provides a solution to likelihood-ratio detection, estimation and discrimination problems in the presence of many kinds of signal and noise. Among the explicit applications presented are: (1) the photon-counter scintillation detection of nuclear particles when particle flux is low, (2) the photon-counting detection of weak optical signals in the presence of ionizing radiation, and (3) the design of a star-scanner spacecraft guidance system adequate for hostile space environments.

Teich, M. C.↗

Radionuclide Counting Technique Measures Wind Velocity

Proposed technique for measuring wind velocity based on inverse-squarelaw variation of radioactive counting rates. In proposal, radioative source is deposited on bottom of light, hollow sphere and suspended by flexible wire over radiation counter, Anemometer based on this concept is self-contained, portable, yet not too fragile. Used for extended periods of time, even at remote, inhospitable and inaccessible sites.

Singh, J. J.↗