Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of NCERC Critical Experiments with ENDF/B Nuclear Data Libraries

Nuclear data (ND) libraries are the backbone of the nuclear industry, as they are the collections of tabulated probabilities that define sub-atomic particle interactions with matter. In the areas of criticality safety and experiments, no evaluated nuclear data files (ENDF) are more important than those containing neutron cross section data. It is upon these files, and accompanying radiation transport codes, that practitioners are enabled to safely design both subcritical and critical systems. Likewise, in a symbiotic fashion, it is the same critical assemblies which are used primarily to validate that the cross sections are correct. The ENDF/B library, the United States’ national library maintained by the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory (BNL), is soon releasing a new version, ENDF/B-VIII.1. Prior to the official release, several beta versions of the library were prepared and tested in simulation suites. The work presented here are results comparing the newest ENDF/B beta release (ENDF/B-VIII.1b3) and ENDF/B-VIII.0 with recent experiments done at the National Criticality Experiments Research Center (NCERC) as well as correlated experiments from the Los Alamos Critical Experiments Facility (LACEF). These NCERC and LACEF experiments were performed in part to provide validation for various cross sections that were identified as insufficient in the ENDF/B-VIII.0. In particular, lead, copper, fluorine, and chlorine, as well as the major actinides, were targeted from the last decade of critical experiments.

97 MATHEMATICS AND COMPUTING↗

Overview of the Tolerance Limit Calculations with Application to TSURFER

To establish confidence in the results of computerized physics models, a key regulatory requirement is to develop a scientifically defendable process. The methods employed for confidence, characterization, and consolidation, or C3, are statistically involved and are often accessible only to avid statisticians. This manuscript serves as a pedagogical presentation of the C3 process to all stakeholders—including researchers, industrial practitioners, and regulators—to impart an intuitive understanding of the key concepts and mathematical methods entailed by C3. The primary focus is on calculation of tolerance limits, which is the overall goal of the C3 process. Tolerance limits encode the confidence in the calculation results as communicated to the regulator. Understanding the C3 process is especially critical today, as the nuclear industry is considering more innovative ways to assess new technologies, including new reactor and fuel concepts, via an integrated approach that optimally combines modeling and simulation and minimal targeted validation experiments. This manuscript employs intuitive, analytical, numerical, and visual representations to explain how tolerance limits may be calculated for a wide range of configurations, and it also describes how their values may be interpreted. Various verification tests have been developed to test the calculated tolerance limits and to help delineate their values. The manuscript demonstrates the calculation of tolerance limits for TSURFER, a computer code developed by the Oak Ridge National Laboratory for criticality safety applications. The goal is to evaluate the tolerance limit for TSURFER-determined criticality biases to support the determination of upper, subcritical limits for regulatory purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

239 Pu R -matrix Analysis and Neutron Multiplicities in the Neutron Energy Region up to a few keVs [Abstract]

The evaluation of 239 Pu neutron resonance parameters coupled to neutron multiplicities $\overline{v}_p$ is of particular importance to investigate the ($\mathcal{n, γf}$) reaction in which a $\mathcal{γ}$-ray emission occurs before the scission of the compound nuclear. This reaction has offered one explanation for the fluctuations in the measured values of $\overline{v}_p$ In this regard, the competition between ($\mathcal{n, γf}$) reaction and the direct fission process can be also included in the R matrix analysis of fission and capture measured data. The goal of this work is the coupled evaluation of the $\mathcal{n}$+ 239 Pu resonance parameters and related neutron multiplicities by ensuring the adoption of thermal neutron constants recently evaluated at the International Atomic Nuclear Energy as well as the recommended (thermal-neutron) induced prompt neutron fission spectrum (PFNS). Moreover, this new set of physical evaluated quantities should also guarantee the agreement for high-leakage solution benchmarks while keeping the good performance of large thermal solution assemblies.

07 ISOTOPE AND RADIATION SOURCES↗

Update on NNL TSL Validation Efforts [Slides]

This presentation covers how a new sub-thermal neutron transmission capability at RPI LINAC is now in use to help validate TSL evaluations. Additionally, NNL has contributed multiple material evaluations to ENDF/B-VIII.1. Lastly, this presentation covers new methods to improve TSL physics and accuracy are being formulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Critical Experiment Benchmark Applicability to a Large-Capacity HALEU Transportation Package Concept

This work presents an assessment of the applicability of existing benchmark critical experiments to the criticality safety code validation for a large-capacity high-assay low-enriched uranium (HALEU) transportation package concept. Numerous next-generation nuclear reactor designs require HALEU fuel, which is characterized by an enrichment between 5 and 20 wt% 235 U. The U.S. Department of Energy (DOE) has proposed to recover and downblend highly enriched uranium from DOE-owned used nuclear fuel to accelerate the demonstration of commercially viable microreactor technologies. One element of the infrastructure needed to demonstrate HALEU-fueled reactors is the ability to safely transport enriched product to be used for fuel fabrication. There is uncertainty as to whether existing critical benchmark experiment data are sufficient to support criticality safety code validation for HALEU transportation applications. The anticipated chemical form of the HALEU in the proposed transportation concept is UO 2 with 20 wt% 235 U/U. The concept uses a combination of an existing transportation packaging design and a novel basket design, including borated aluminum flux traps. The basket provides space for 18 reusable, stainless steel canisters that contain the HALEU. In 10 CFR 71, normal conditions of transport (NCTs) and hypothetical accident conditions (HACs) are defined for fissile material transportation packages. NCT and HAC KENO-VI models of the transportation package were developed using the Standardized Computer Analyses for Licensing Evaluation (SCALE) 6.2.3 computer code package, and optimum moderation conditions were determined using the SCALE SAMPLER sequence. The SCALE Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) sequences were then used to compare the neutronic characteristics of 1584 International Criticality Safety Benchmark Evaluation Project benchmark critical experiments with the NCT and HAC HALEU transportation models. The TSUNAMI integral correlation coefficient c k was the criterion used to rank neutronic similarity. Thirty-four experiments were identified as similar (c k ≥ 0.9) to the NCT model, and 55 experiments were identified as similar to the HAC model. Hundreds of experiments were also identified as at least marginally similar (c k ≥ 0.8) to both models. The results indicate that additional critical experiments are unlikely to be needed to support HALEU transportation criticality safety analyses for package concepts similar to the concept package analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY22 NCSP accomplishments for U and Pu Evaluations [Slides]

This presentation covers fiscal year 2022 for Nuclear Criticality Safety Program (NCSP) accomplishments for Uranium (U) and Plutonium (Pu) evaluations. This presentation includes an overview on plutonium and uranium. Additionally, this presentation covers the inclusion of sub-thermal data for 235 U and the inclusion of LANL ratio capture-to-fission data for 233 U and 235 Pu. The presentation ends with a discussion on 239 Pu Primary fit of Mosby's data as reported and a look at the uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous-Energy ENDF/B-VIII.0 Cross Section and SCALE 6.2.4 Performance for Nuclear Criticality Safety Applications: 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238 U, 239 Pu

As part of the nuclear data evaluation and validation cycle, the ENDF/B-VIII.0 cross-section library released in 2018 requires testing to determine areas of improvement and deterioration. Previous work by the authors investigated the performance of 16 O, 56 Fe, and 63,65 Cu cross sections, with this study acting as an extension of the prior work. In addition to the isotopes and nuclear criticality safety benchmarks of interest to the prior work, benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook were selected for their k eff sensitivity to 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238U, or 239 Pu cross sections and were modeled in the SCALE code system maintained by Oak Ridge National Laboratory. In total, 253 benchmark configurations were selected for their sensitivities and modeled using SCALE 6.2.4 Criticality Safety Analysis Sequences (CSAS) continuous-energy Monte Carlo k eff calculations. This collection includes and expands upon the 99 benchmarks in the prior work. The AMPX-processed ENDF/B-VIII.0 library was decomposed into individual ENDF/B-VIII.0 datum libraries for each isotope of interest. Doing so allowed for the individual substitution of an ENDF/B-VIII.0 cross section in the place of ENDF/B-VII.1, determining isotope-specific effects of ENDF/B-VIII.0 relative to ENDF/B-VII.1. Full library calculations with entirely ENDF/B-VII.1 data or entirely ENDF/B-VIII.0 data were also executed. As a measure of performance, the average relative deviation was determined as the ratio of the deviation between calculated and experimental keff to the propagated calculational and experimental uncertainty. With calculated full library and isotope-specific ENDF/B-VIII.0 k eff ’s, an optimized combination of data libraries was estimated and confirmed with SCALE calculations. This showed that reverting 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 resulted in improved performance relative to the full ENDF/B-VIII.0 library. Across all 253 benchmarks, the average relative deviation was 1.29σ for the full ENDF/B-VII.1 library, 1.17σ for the full ENDF/B-VIII.0 library, and 0.97σ for the optimized combination. The reversion of 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 in the 99 benchmarks of the prior work resulted in further improved experimental agreement compared to the previously reported improvement from 16 O and 65 Cu alone. Therefore, it is suggested that applications with significant sensitivities to 239 Pu, 58 Ni, 16 O, and 65 Cu consider their choice of nuclear data library.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗