Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Advanced Cryogenic Insulation Systems

New materials in recent decades have enabled advances in thermal insulation systems for storage and transfer of cryogens. To preserve the cold and achieve efficient cryogenic systems, a combination of materials, testing, and engineering is required. The total heat leak into any cryogenic assembly is comprised of three main parts: 1) heat leak through the insulation, 2) heat leak through the support structures, and 3) heat leak attributed to piping penetrations and feedthroughs (and their negative effects on the insulation). This "cold triangle" approach provides a basis for evaluating performance benefits of new materials and analyzing the cost effectiveness in overall system design. Provided are thermophysical data for aerogels, aerogel composites, novel multilayered composites, and glass bubbles for standard test conditions of 293 K and 78 K under conditions from high vacuum to ambient pressure. Examples of cryogenic storage tanks show the relative importance of both insulation and structural materials for achieving designs of highest energy efficiency.

Multilayer Insulation↗

Resistance drift in Ge 2 Sb 2 Te 5 phase change memory line cells at low temperatures and its response to photoexcitation

Resistance drift in amorphous Ge 2 Sb 2 Te 5 is experimentally characterized in melt-quenched line cells in the range of 300 K to 125 K and is observed to follow the previously reported power-law behavior with drift coefficients in the range of 0.07 to 0.11 in the dark, linearly decreasing with 1/kT. While these drift coefficients measured in the dark are similar to commonly observed drift coefficients (~0.1) at and above room temperature, measurements under light show a significantly lower drift coefficient (0.05 under illumination vs 0.09 in the dark at 150 K). Periodic on/off switching of light shows a sudden decrease/increase in resistance, attributed to photo-excited carriers, followed by a very slow response (~30 min at 150 K) attributed to contribution of electron traps and slow trap-to-trap charge exchanges. A device-level electronic model is used to relate these experimental findings to gradual charging of electron traps in amorphous Ge 2 Sb 2 Te 5 , which gives rise to growth of a potential barrier for holes in time and, hence, resistance drift.

42 ENGINEERING↗

NERVA irradiation program. GTR 23, volume 1: Combined effects of reactor radiation and cryogenic temperature on NERVA structural materials

Specimens fabricated from structural materials that were candidates for certain NERVA applications were irradiated in liquid nitrogen (LN2), liquid hydrogen (LH2), water, and air. The specimens irradiated in LN2 were stored in LN2 and finally tested in LN2, or at some higher temperature in a few instances. The specimens irradiated in LH2 underwent an unplanned warmup while in storage so this portion of the test was lost; some specimens were tested in LN2 but none were tested in LH2. The Ground Test Reactor was the radiation source. The test specimens consisted mainly of tensile and fracture toughness specimens of several different materials, but other types of specimens such as tear, flexure, springs, and lubricant were also irradiated. Materials tested include Hastelloy X, Al, Ni steel, steel, Be, ZrC, Ti-6Al-4V, CuB, and Ti-5Al-2.5Sn.

Mcdaniel, R. H.↗

Measuring Poisson Ratios at Low Temperatures

Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

Boozon, R. S.↗

Direct determination of the morphology, structure and composition of cometary and interstellar ice analogs in the laboratory

Ices of various kinds (H2O, CO, CO2, CH4, NH3, CH3OH, etc.) comprise a volumetrically significant proportion of objects in the solar system (comets, outer planets, planetary rings, satellites) as well as in interstellar space (astrophysical ices). The refinement of analytical electron microscopy (AEM) procedures for storing, preparing and analyzing ices and other materials at cryogenic temperatures is discussed. These procedures will be essential to the successful analysis of returned comet nucleus samples.

Blake, D. F.↗