Search NASA⌕ Search

SEARCH · Search NASA

Results for “curing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Chemical approach for controlling nadimide cure temperature and rate

Polyimide resins suitable for use as composite matrix materials are formed by copolymerization of maleic and norbornenyl end-capped monomers and oligomers. The copolymers can be cured at temperatures under about 300 C. by controlling the available concentration of the maleic end-capped reactant. This control can be achieved by adding sufficient amounts of said maleic reactant, or by chemical modification of either copolymer, to increase Diels-Alder retrogression of the norbornenyl-capped reactant and/or holding initiation and polymerization to a rate compatible with the availability of the maleic-capped reactant.

Lauver, R. W.↗

Reduction of Moisture Effects During the Cure of Epoxy Adhesives Used in Composite Repair

The requirements for repair work on Naval aircraft composite wing skins that can be performed under depot conditions (or still worse, under field conditions) are quite restrictive. Equipment that can be used is rather limited as are the available repair space and time. The procedures must be simple enough so that they can be performed satisfactorily by personnel without special knowledge in composite materials technology. Repairs of small holes should not require more than perhaps a short predrying cycle (with heat guns) and a subsequent patch bonding using a heating blanket, held in place by applying a vacuum. However, it has been observed during simulated experimental repair work that the glue lines frequently show a high content of pores and bubbles which are attributed to evaporation of moisture during the curing cycle. (Of course, other volatile materials such as residual solvent would act similarly). The purpose of this paper is to give some detailed analysis of the problem of moisture transport as a function of repair conditions, and to discuss some preliminary work to reduce the effect of moisture by removing moisture chemically with carbodiimides before it reaches a critical level for bubble formations.

Augl, J. M.↗

Cleaner Vacuum-Bag Curing

Improvement upon recommended procedures saves time and expense. Autoclave molding in vacuum bag cleaner if adhesive-backed covering placed around caul plate as well as on mold plate. Covering easy to remove after curing and leaves caul plate free of resin deposits.

Clemons, J. M.↗

Cure study of soluble aromatic polyimide films

Several soluble aromatic poly(amic acid) films were staged at intervals to 325 C and characterized by IR spectroscopy and various solution property techniques. A series of films in which the polymer had been endcapped in an effort to control chain extension was also examined. Much of the behavior observed is consistent with an interpretation that a reduction in molecular weight occurred during cure before the ultimate molecular weight was achieved as a polyimide.

Young, Philip R.↗

Qualification of room-temperature-curing epoxy adhesives for spacecraft structural applications

An adhesive-bonding test program is being conducted in order to develop structural adhesives applicable to JPL spacecraft. A noteworthy application for such an adhesive will be JPL's Galileo mission, whose trajectory will involve the circumnavigation of the planet Venus prior to Jupiter rendezvous, and will accordingly require stringent temperature and radiation environment requirements. The baseline adhesive for the test program is the EA 934 room temperature-cure epoxy, which has been widely used as a 'space-qualified' material.

Carpenter, Alain↗

Addition polymers from 1,4,5,8-tetrahydro-1,4;5,8-diepoxyanthracene and Bis-dienes. 2: Evidence for thermal dehydration occurring in the cure process

Diels-Alder cycloaddition copolymers from 1,4,5,8-tetrahydro-1,4;5,8-diepoxyanthracene and anthracene end-capped polyimide oligomers appear, by thermogravimetric analysis (TGA), to undergo dehydration at elevated temperatures. This would produce thermally stable pentiptycene units along the polymer backbone, and render the polymers incapable of unzipping through a retro-Diels-Alder pathway. High resolution solid 13C nuclear magnetic resonance (NMR) of one formulation of the polymer system before and after heating at elevated temperatures, shows this to indeed be the case. NMR spectra of solid samples of the polymer before and after heating correlated well with those of the parent pentiptycene model compound before and after acid-catalyzed dehydration. Isothermal gravimetric analyses and viscosities of the polymer before and after heat treatment support dehydration as a mechanism for the cure reaction.

Meador, Mary Ann B.↗

Qualification of room-temperature-curing structural adhesives for use on JPL spacecraft

An evaluation is made of the comparative advantages of numerous room temperature-cure structural primers and adhesives applicable to spacecraft structures. The EA 9394 adhesive and BR 127 primer were chosen for use in all primary structure bonding on the Galileo spacecraft, in virtue of adequate room-temperature lap shear and peel strengths and superior mechanical properties above 200 F. EA 9394 also offers superior work life, shelf-life, and storage properties, by comparison with the EA 934 alternative.

Carpenter, Alain↗

Viscoelastic properties of addition-cured polyimides used in high temperature polymer matrix composites

Viscoelastic properties of the addition cured polyimide, PMR-15, were studied using dynamic mechanical and stress relaxation tests. For temperatures below the glass transition temperature, T sub g, the dynamic mechanical properties measured using a temperature scan rate of 10 C/min were strongly affected by the presence of absorbed moisture in the resin. Dynamic mechanical properties measured as a function of time during an isothermal hold provided an indication of chemical changes occurring in the resin. For temperatures above (T sub g + 20 C), the storage modulus increased continuously as a function of time indicating that additional crosslinking is occurring in the resin. Because of these changes in chemical structures, the stress relaxation modulus could not be measured over any useful time interval for temperatures above T sub g. For temperatures below T sub g, dynamic mechanical properties appeared to be unaffected by chemical changes for times exceeding 1 hr. Since the duration of the stress relaxation tests was less than 1 hr, the stress relaxation modulus could be measured. As long as the moisture content of the resin was less than 2 pct, stress relaxation curves measured at different temperatures could be superimposed using horizontal shifts along the log(time) axis with only small shifts along the vertical axis.

Roberts, Gary D↗

Thread-Pull Test Of Curing Adhesive

Hardness (and degree of cure) of adhesive layer measured by pulling previously inserted thread out of layer. Strength of bond measured directly on assembly rather than on samples, which can be misleading.

Johnson, James A.↗

Curing A Large Composite Cylinder Without An Autoclave

Proposed technique provides application of heat and pressure to cure fiber-wound composite cylinder too large to fit in autoclave. Tube wound around cylinder applies pressure. Blanket distributes pressure. Pressure expels gas bubbles from material. Heat applied by conventional methods.

Frazer, Robert E.↗

Viscoelastic properties of addition-cured polyimides used in high temperature polymer matrix composites

The viscoelastic properties of an addition-cured polyimide, PMR-15, were evaluated through dynamic mechanical and stress relaxation testing. Below the glass transition temperature, the dynamic mechanical properties of the composites are strongly affected by the absorbed moisture in the resin. At temperature 20 C and more above the glass transition temperature, the storage modulus increases continuously with time, indicating that additional crosslinking is occurring in the resin. For resin moisture contents less than 2 percent, stress relaxation curves measured at different temperatures can be superimposed using horizontal shifts along the log(time) axis with only small shifts along the vertical axis.

Roberts, Gary D.↗

Addition Curing Thermosets Endcapped with 4-Amino (2.2) Paracyclophane

A new family of addition curing polyimides were prepared that contained 4-amino (2.2)-paracyclophane as the endcap. An improved synthesis of the endcap 4-amino-(2.2) cyclophane was accomplished increasing the yield to 60 percent and simplifying the procedure. DSC and rheological analysis of endcapped polyimide oligomers confirmed that the onset for polymerization of the ethylene bridge was 250 C. C-13 CP/MAS NMR was used to determine the structural changes of the oligomers after thermal treatment. The cyclophane capped polyimides were successfully compression molded to form void free neat resin specimens. Tg's as high as 353 C were obtained by thermomechanical analysis for postcured samples. Preliminary thermal stability studies suggest that these resins have a high onset of decomposition ranging from 549 to 567 C.

Waters, John F.↗

Photothermal Monitoring Of Curing Of Polymers

Time-resolved infrared radiometry (TRIR) adapted to monitoring curing of some polymers in production. Proposal part of continuing effort to perfect production of hydroxy-terminated polybutadiene for use in liners of solid-fuel rocket motors. Applicable to monitoring changing states of many other materials in process. TRIR, non-contact technique implemented with remotely situated equipment and better suited to use in production.

Rooney, Michael↗

In Site Analysis of a High Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high temperature (330 C) polymerization reaction was successfully monitored in real time using a modulated fiber-optic FT-Raman spectrometer. A phenylethynyl terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Cooper, John↗

In Situ Analysis of a High-Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high-temperature (330 C) polymerization reaction was successfully monitored in real time with the use of a modulated fiber-optic Fourier transform (FT)-Raman spectrometer. A phenylethynyl-terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Aust, Jeffrey F.↗

Phenylethynyl Terminated Arylene Ether Oxadiazole and Triazole Oligomers and Their Cured Polymers

Several novel phenylethynyl terminated arylene ether oligomers containing oxadiazole and triazole rings were prepared as part of an effort to develop high performance polymers with an attractive combination of properties (e.g. processability and mechanical performance) for future NASA applications. The oligomers displayed low melt viscosities and good solubilities. Thin films cast from solutions of the oligomers and cured for one hour at 350 C in air gave good tensile properties. Titanium to titanium (6Al-4V) tensile shear specimens were readily fabricated and provided moderate strengths. The chemistry and properties of these new materials are discussed.

Thompson, C. M.↗