Search NASA⌕ Search

SEARCH · Search NASA

Results for “current limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Current collection in an anisotropic collisionless plasma

A general method is given to derive the current-potential relations in anisotropic plasmas. Orbit limit current is assumed. The collector is a conductive sphere or an infinite cylinder. Any distribution which is an arbitrary function of the velocity vector can be considered as a superposition of many mono-energetic beams whose current-potential relations are known. The results for two typical pitch angle distributions are derived and discussed in detail. The general properties of the current potential relations are very similar to that of a Maxwellian plasma except for an effective temperature which varies with the angle between the magnetic field and the charging surface. The conclusions are meaningful to generalized geometries.

Li, Wei-Wei↗

Theoretical Assessment of the Transition Between Electron Emission Mechanisms for Nonplanar Diodes

Theoretically and computationally describing the operation of nanodiodes requires characterizing the transitions between multiple electron emission mechanisms for nanodiodes with complicated geometries. This motivates our development of techniques to determine when simplified theories for individual mechanisms suffice compared to more complete, but more computationally expensive, models. Leveraging recent theories that define a canonical gap distance to translate planar theory to nonplanar diodes, we derive the conditions for the transitions among thermal emission, field emission, and space-charge-limited current density (SCLCD) in vacuum and with collisions for non-Cartesian coordinate systems, including spherical, cylindrical, and prolate spheroidal coordinate systems. Particle-in-cell (PIC) simulations of the current density as a function of applied voltage for a tip-to-plate geometry in vacuum agreed qualitatively with the asymptotes for thermal emission at low voltage and SCLCD at higher voltage using the canonical gap distance. As a result, this demonstrates the utility of this approach for guiding system design and suggests future extensions to save simulation time for more realistic geometries that are more computationally expensive.

Conformal mapping↗

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

High-Efficiency Multi-Junction Space Solar Development Utilizing Lattice Grading

Progress towards achieving a high one-sun air mass 0 (AM0) efficiency in a monolithic dual junction solar cell comprised of a 1.62 eV InGaP top cell and a 1.1 eV InGaAs bottom cell grown on buffered GaAs is reported. The performance of stand-alone 1.62 eV InGaP and 1.1 eV InGaAs cells is compared to that of the dual junction cell. Projected AM0 efficiencies of 15.7% and 16.5% are expected for the 1.62 eV InGaP and 1.1 eV InGaAs cells grown on buffered GaAs. The dual junction cell has a projected one-sun AM0 conversion efficiency of 17%. The projected efficiencies are based upon the application of an optimized anti-reflective coating (ARC) to the as-grown cells. Quantum efficiency (QE) data obtained from the dual junction cell indicate that is is bottom cell current limited with the top cell generating 50% more current than the bottom cell. A comparison of the QE data for the stand-alone 1.1 eV InGaAs cell to that of the 1.1 eV InGaAs bottom cell in the tandem configuration indicates a degradation of the bottom cell conversion efficiency in the tandem configuration. The origin of this performance degradation is at present unknown. If the present limitation can be overcome, then a one-sun AM0 efficiency of 26% is achievable with the 1.62 eV/1.1 eV dual junction cell grown lattice-mismatched to GaAs.

Stan, Mark A.↗

Engineered enzymatic cascade converts diols to amino alcohols

Aliphatic amino alcohols such as 6-amino-1-hexanol are potential platform chemicals for a variety of advanced materials, but applications are currently limited by reagent costs. Aliphatic amino alcohols can currently be synthesized from biomass-derived diols at elevated temperatures and pressures using Ru-based catalysts that produce a mixture of amino-alcohol, diamine, and cyclic amine products. Replacing chemical amination with an enzymatic cascade would reduce resource needs and enable reactions under milder conditions. In this work, we characterized a two-enzyme cascade that selectively converts C4–C7 diols to the corresponding amino alcohols under aqueous conditions at room temperature and pressure. By engineering the rate-limiting enzyme and optimizing reaction conditions, we increased amino alcohol production nearly 30-fold, achieving a selectivity of 99%. The same enzyme cascade could also be used to convert amino alcohols into cyclic amines through reduction of the corresponding cyclic imine. This engineered cascade provides a green opportunity to sustainably synthesize asymmetric bifunctional platform chemicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space charge limited corrections to the power figure of merit for diamond

An interpretation of the unipolar figure of merit is formulated for wide bandgap (WBG) semiconductors based on the on-state specific resistance (RON,sp) derived from the space charge limited current–voltage relationship (Mott–Gurney square law). The limitations of the traditional Ohmic R ON,sp for WBG semiconductors are discussed, particularly at low doping, while the accuracy of the Mott–Gurney based R ON,sp is confirmed by Silvaco ATLAS drift–diffusion simulations of diamond Schottky pin diodes. The effects of incomplete ionization are considered as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EMPHATIC Silicon Strip Detector Efficiencies

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, Virginia [Illinois U., Urbana (main)]↗

Some Comments on Longevity by a Technologist

The durability of flywheels was investigated. Since only composite flywheels possess the potential for system energy densities in the range of 20 to 40 W hr/kg, and they are not yet at a level of maturity where a comfortable data base exists, the longevity aspects of the yet to be developed devices is still a speculation. The general methodologies that have been used in some of the more established technology areas to establish some degree of credibility in the ability to predict the upper limits of expected useful life based on the current limiting decay mechanism are outlined.

Thaller, L. H.↗

Determining the Efficiency of EMPHATICs Silicon Strip Detectors (SSDs)

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, V. [Illinois U., Urbana (main)]↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

Raitt, W. John↗

Electrodialysis simulation to achieve optimum current density

Electrodialysis is used to remove salts from waste or other water streams, to yield a concentrated brine and a substatially deionized product water. During the electrodialysis process, the boundary layer adjacent to the ion selective membrane can become depleted of ions, resulting in severe pH changes sometimes accompanied by precipitation, and power losses, by a process known as water splitting. In order to optimize the applied electric current density, to achieve maximum deionization without exceeding the limiting current at any point along the path, a simulation program has been created to plot ion concentrations and fluxes, and cell current densities and voltages along the electrodialysis path. A means for tapering the current density along the path is recommended.

Herrmann, Cal C.↗

New Developments in Retropropulsion Testing for Mars Entry, Descent and Landing

NASA’s plans for landing human-scale payloads on Mars in the next decade require that retrorockets be used to decelerate the atmospheric entry vehicle continuously from supersonic conditions through soft touchdown. Conventional Mars entry vehicle architectures that include a single parachute for supersonic-to-subsonic descent are not scalable to the sizes needed to land humans on Mars (~20 metric tons). The major aerosciences risks are the uncertainties in predicting aerodynamic stability and performance during powered free-flight and landing. These risks are influenced partially by current limitations in relevant data and testing methods. Consequently, trajectory simulations currently depend on unvalidated powered descent and landing aerodynamics models. NASA engineers have identified gaps in testing methods that, if addressed, would improve the ability to validate these models. There are gaps in capabilities to test multi-engine hot-gas retropropulsion systems in US wind tunnels. This is partially due to the successful use of parachutes as decelerators for human spaceflight at Earth and for the entire Mars lander program to date. Retropulsion test data historically and to this day are limited to using high pressure air jets, at comparatively low temperatures,as engine plume simulants on subscale wind tunnel models. Additionally, the ability to directly measure aerodynamic interference force and moments is limited by existing flow-through balance capabilities. This paper briefly covers historical and recent test data, and identifies new ground test techniques as a means to provide more relevant test data for powered flight and landing aerodynamic model validation.These techniques include using heated inert gases as a substitute for combustion products, additively manufactured 6-component flow-through force and moment balances, and off-body quantitative diagnostic measurements.

Retropropulsion↗

The Frequency Shift and $Q$ of Disordered Superconducting RF Cavities

Niobium superconducting radio-frequency (SRF) cavities for high-energy accelerator applications have been greatly improved in terms of the quality factor $Q$ by techniques such as Nitrogen doping. However, the mechanisms leading to improvement in $Q$ are still not fully understood. Quite recently the SRF group at Fermilab measured anomalies in the frequency shift of N-doped SRF Niobium cavities near the transition temperature. Here we report our theoretical analysis of these results based on the microscopic theory of superconductivity that incorporates anisotropy of the superconducting gap and inhomogeneous disorder in the screening region of the SRF cavities. We are able to account for frequency shift anomalies very close to $T_c$ on the order of fractions of 1 kHz. Our results for the frequency shift and Q are in good agreement with the experimental data reported for all four N-doped Nb SRF cavities by Bafia et al. We also compare our theory with an earlier report on a Nb sample measured at 60 GHz. In addition, we show that the quality factor calculated theoretically has a peak of upper convexity with the largest $Q$ at intermediate levels of disorder. For strong disorder, i.e. the dirty limit, pair breaking in the presence of disorder and screening currents limits the $Q$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NAWI Research Spotlight: Technoeconomic Assessment of Brine Valorization from Brackish Groundwater

This NAWI Research Spotlight Webinar was presented to the NAWI Alliance on June 27, 2024. The presentation describes project progress to date on a technoeconomic assessment of brine valorization from brackish groundwater. Desalination at inland brackish groundwater treatment plants is currently limited by high costs of concentrate management and disposal. With current methods, 5-25% of the feed is disposed of as concentrate, with 98% of disposal using conventional methods (i.e. no byproduct recovery). This project aims to assess the technical and economic feasibility of industrial ecosystems to desalinate brackish groundwater and supply existing and potential markets for clean concentrate or other bulk constituents from the brine.

Fritz, Alison↗

Integrated P-channel MOS gyrator

A gyrator circuit is described which is of the conventional configuration of two amplifiers in a circular loop, one producing zero phase shift and the other producing 180 phase reversal, in a circuit having medium Q composed of all field effect transistors of the same conductivity type. The current source to each gyrator amplifier comprises an amplifier which responds to changes in current, with the amplified signals feed back so as to limit current. The feedback amplifier has a large capacitor connected to bypass high frequency components, thereby stabilizing the output. The design makes possible fabrication of circuits with transistors of only one conductivity type, providing economies in manufacture and use.

Hochmair, E. S.↗