Search NASA⌕ Search

SEARCH · Search NASA

Results for “data filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multiscale Persistent Functions for Biomolecular Structure Characterization

Here in this paper, we introduce multiscale persistent functions for biomolecular structure characterization. The essential idea is to combine our multiscale rigidity functions (MRFs) with persistent homology analysis, so as to construct a series of multiscale persistent functions, particularly multiscale persistent entropies, for structure characterization. To clarify the fundamental idea of our method, the multiscale persistent entropy (MPE) model is discussed in great detail. Mathematically, unlike the previous persistent entropy (Chintakunta et al. in Pattern Recognit 48(2):391–401, 2015; Merelli et al. in Entropy 17(10):6872–6892, 2015; Rucco et al. in: Proceedings of ECCS 2014, Springer, pp 117–128, 2016), a special resolution parameter is incorporated into our model. Various scales can be achieved by tuning its value. Physically, our MPE can be used in conformational entropy evaluation. More specifically, it is found that our method incorporates in it a natural classification scheme. This is achieved through a density filtration of an MRF built from angular distributions. To further validate our model, a systematical comparison with the traditional entropy evaluation model is done. Additionally, it is found that our model is able to preserve the intrinsic topological features of biomolecular data much better than traditional approaches, particularly for resolutions in the intermediate range. Moreover, by comparing with traditional entropies from various grid sizes, bond angle-based methods and a persistent homology-based support vector machine method (Cang et al. in Mol Based Math Biol 3:140–162, 2015), we find that our MPE method gives the best results in terms of average true positive rate in a classic protein structure classification test. More interestingly, all-alpha and all-beta protein classes can be clearly separated from each other with zero error only in our model. Finally, a special protein structure index (PSI) is proposed, for the first time, to describe the “regularity” of protein structures. Basically, a protein structure is deemed as regular if it has a consistent and orderly configuration. Our PSI model is tested on a database of 110 proteins; we find that structures with larger portions of loops and intrinsically disorder regions are always associated with larger PSI, meaning an irregular configuration, while proteins with larger portions of secondary structures, i.e., alpha-helix or beta-sheet, have smaller PSI. Essentially, PSI can be used to describe the “regularity” information in any systems.

59 BASIC BIOLOGICAL SCIENCES↗

Engine-Aftertreatment in Closed-Loop Modeling for Heavy Duty Truck Emissions Control

An engine-aftertreatment computational model was developed to support in-loop performance simulations of tailpipe emissions and fuel consumption associated with a range of heavy-duty (HD) truck drive cycles. For purposes of this study, the engine-out exhaust dynamics were simulated with a combination of steady-state engine maps and dynamic correction factors that accounted for recent engine operating history. The engine correction factors were approximated as dynamic first-order lags associated with the thermal inertia of the major engine components and the rate at which engine-out exhaust temperature and composition vary as combustion heat is absorbed or lost to the surroundings. The aftertreatment model included catalytic monolith components for diesel exhaust oxidation, particulate filtration, and selective catalytic reduction of nitrogen oxides (NOx) with urea. Both the engine and aftertreatment models have been calibrated with dynamometer measurements from a commercial 2010-certificated 15-L Cummins diesel engine. The fuel consumption engine map with the reduced data is attached in the appendix. Simulations with the combined engine and aftertreatment models above appear to reveal important trends among the fuel efficiency, emissions control, power demand for HD trucks under realistic drive cycle conditions. Thus, this type of computational simulation appears to have significant value in choosing among options for HD vehicle design and operation.

Gao, Zhiming↗

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulator of realistic x-ray beam for diagnostic applications

Purpose: Monte Carlo simulation is a very useful tool for radiotherapy and diagnostic radiology. Yet even with the latest PCs, simulation of photon spectra emitted by an x-ray tube is a time-consuming task, potentially reducing the possibility to obtain relevant data such as dose evaluations, simulation of geometric settings, or monitor detector efficiency. This study developed and validated a method to generate random numbers for realistic beams in terms of photon spectrum and intensity to simulate x-ray tubes via Monte Carlo algorithms. Methods: Starting from literature data, the most common semiempirical models of bremsstrahlung are analyzed and implemented, adjusting their formulation to describe a large irradiation area (i.e., large field of view) and to take account of the heel effect as in common practice during patient examinations. Results: Simulation results show that Birch and Marshall's model is the fastest and most accurate for the aims of this work. Correction of the geometric size of the beam and validation of the intensity variation (heel effect) yielded excellent results with differences between experimental and simulated data of less than 6%. Conclusions: The results of validation and execution time showed that the tube simulator calculates the x-ray photons quickly and efficiently and is perfectly capable of considering all the phenomena occurring in a real beam (total filtration, focal spot size, and heel effect), so it can be used in a wide range of applications such as industry, medical physics, or quality assurance.

60 APPLIED LIFE SCIENCES↗

Application of Pulsed Electrical Fields for Advanced Cooling and Water Recovery in Coal-Fired Power Plant

The overall objective of the present work was to develop technologies to reduce freshwater consumption in a cooling tower of coal-based power plant so that one could significantly reduce the need of make-up water. The specific goal was to develop a scale prevention technology based an integrated system of physical water treatment (PWT) and a novel filtration method so that one could reduce the need for the water blowdown, which accounts approximately 30% of water loss in a cooling tower. The present study investigated if a pulsed spark discharge in water could be used to remove deposits from the filter membrane. The test setup included a circulating water loop and a pulsed power system. The present experiments used artificially hardened water with hardness of 1,000 mg/L of CaCO{sub 3} made from a mixture of calcium chloride (CaCl{sub 2}) and sodium carbonate (Na{sub 2}CO{sub 3}) in order to produce calcium carbonate deposits on the filter membrane. Spark discharge in water was found to produce strong shockwaves in water, and the efficiency of the spark discharge in cleaning filter surface was evaluated by measuring the pressure drop across the filter over time. Results showed that the pressure drop could be reduced to the value corresponding to the initial clean state and after that the filter could be maintained at the initial state almost indefinitely, confirming the validity of the present concept of pulsed spark discharge in water to clean dirty filter. The present study also investigated the effect of a plasma-assisted self-cleaning filter on the performance of physical water treatment (PWT) solenoid coil for the mitigation of mineral fouling in a concentric counterflow heat exchanger. The self-cleaning filter utilized shockwaves produced by pulse-spark discharges in water to continuously remove scale deposits from the surface of the filter, thus keeping the pressure drop across the filter at a relatively low value. Artificial hard water was used in the present fouling experiments for three different cases: no treatment, PWT coil only, and PWT coil plus self-cleaning filter. Fouling resistances decreased by 59-72% for the combined case of PWT coil plus filter compared with the values for no-treatment cases. SEM photographs showed much smaller particle sizes for the combined case of PWT coil plus filter as larger particles were continuously removed from circulating water by the filter. The x-ray diffraction data showed calcite crystal structures for all three cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect Of Ventilation On Chronic Health Risks In Schools And Offices

This study provides a risk assessment for chronic health risks from inhalation exposure to indoor air pollutants in offices and schools with a focus how ventilation impacts exposures to, and risks from, volatile organic compounds (VOCs) and particulate matter (PM2.5). We estimate how much health risks could change with varying ventilation rates under two scenarios: (i) halving the measured ventilation rates and (ii) doubling the measured ventilation rates. For the hazard characterization we draw upon prior papers that identified pollutants potentially affecting health with indoor air concentrations responsive to changes in ventilation rates. For exposure assessment we determine representative concentrations of pollutants using data available in current literature and model changes in exposures with changes in ventilation rates. As a metric of disease burden, we use disability adjusted life years (DALYs) to address both cancer and non-cancer effects. We also compare exposures to guidelines published by regulatory agencies to assess chronic health risks. Chronic health risks are driven primarily by particulate matter exposure, with an estimated baseline disease burden of 150 DALYs per 100,000 people in offices and 140 DALYs per 100,000 people in schools. Study results show that PM2.5-related DALYs are not very sensitive to changes in ventilation rates. Filtration is more effective at controlling PM2.5 concentrations and health effects. Non-cancer health effects contribute only a small fraction of the overall chronic health burden of populations in offices and schools (<1 DALY per 100,000 people). Cancer health effects dominate the disease burden in schools (3 DALYs per 100,000) and offices (5 DALYs per 100,000), with formaldehyde being the primary risk driver. In spite of large uncertainties in toxicological data and dose-response modeling, our results support the finding that ventilation rate changes do not have significant impacts on estimated chronic disease burdens. Median estimates of DALYs are approximately doubled when the ventilation rates are halved and there is little reduction in health risks associated with doubling ventilation rates, but the very low baseline disease burden from the indoor exposures we considered makes this unremarkable. In exploring the full range of exposure concentrations, to find the fraction exceeding the Office of Environmental Health and Hazard Assessment’s (OEHHAs) chronic reference exposure levels (cRELs) and United States Environmental Protection Agency’s (USEPA) chronic reference dose (RfD) we found only minor shifts in exposure safety margins when ventilation was doubled or halved. We combined our exposure estimates with cancer potency factors published by OEHHA and USEPA to determine that the annual excess cancer risk per capita are below 1 in a million under all ventilation rate scenarios for individual pollutants. The results indicate that chronic health risks (cancer and non-cancer) associated with VOC and PM2.5 exposure in offices and schools are low and thus the chronic disease burden or health benefits of ventilation changes are likely to be well below both the level of detection by health surveillance studies and the level of regulatory thresholds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compatibility Study of Nanofiltration and Reverse Osmosis Membranes with 1 Cyclohexylpiperidenium Bicarbonate Solutions

The switchable polarity solvent forward osmosis (SPS FO) desalination process requires use of a polishing filtration step to remove trace quantities of draw solution from the product water stream. Selected nanofiltration (NF) and reverse osmosis (RO) membranes were tested for their ability to recover water from 1-cyclohexylpiperidenium bicarbonate solutions in this application. This submission includes the experimental data used to calculate NF and RO membrane flux-normalized net driving pressure (FNNDP) and flux-normalized rejection (FNR) performance in recovering water from 1-cyclohexylpiperidenium bicarbonate solutions. This data is further described and visualized in the manuscript entitled "Compatibility study of nanofiltration and reverse osmosis membranes with 1 cyclohexylpiperidenium bicarbonate solutions" (see attached Compatibility Study Manuscript).

15 GEOTHERMAL ENERGY↗

Perturbations in the Urinary Exosome in Transplant Rejection

Background: Urine exosomes, vesicles exocytosed into urine by all renal epithelial cell types, occur under normal physiologic and disease states. Exosome contents may mirror disease-specific proteome perturbations in kidney injury. Analysis methodologies for the exosomal fraction of the urinary proteome were developed and for comparing the urinary exosomal fraction versus unfractionated proteome for biomarker discovery. Methods: Urine exosomes were isolated by centrifugal filtration from mid-stream, second morning void, urine samples collected from kidney transplant recipients with and without biopsy matched acute rejection. The proteomes of unfractionated whole urine (Uw) and urine exosomes (Uexo) underwent mass spectrometry-based quantitative proteomics analysis. The proteome data were analyzed for significant differential protein abundances in acute rejection (AR). Results: Identifications of 1018 and 349 proteins, Uw and Uexo fractions, respectively, demonstrated a 279 protein overlap between the two urinary compartments with 25%(70) of overlapping proteins unique to Uexoand represented membrane bound proteins (p=9.31e-7). Of 349 urine exosomal proteins identified in transplant patients 220 were not previously identified in the normal urine exosomal fraction. Uexo proteins (11), functioning in the inflammatory / stress response, were more abundant in patients with biopsy-confirmed acute rejection, 3 of which were exclusive to Uexo. Uexo AR-specific biomarkers (8) were also detected in Uw, but since they were observed at significantly lower abundances in Uw, they were not significant for AR in Uw. Conclusions: A rapid urinary exosome isolation method and quantitative measurement of enriched Uexo proteins was applied. Urine proteins specific to the exosomal fraction were detected either in unfractionated urine (at low abundances) or by Uexo fraction analysis. Perturbed proteins in the exosomal compartment of urine collected from kidney transplant patients were specific to inflammatory responses, and were not observed in the Uexo fraction from normal healthy subjects. Uexo specific protein alterations in renal disease provide potential mechanistic insights and offer a unique panel of sensitive biomarkers for monitoring for acute transplant rejection.

Environmental Molecular Sciences Laboratory↗

Near-Tank Treatment of Hanford Tank Waste: Pilot-Scale Testing - 12107

In order to reduce the number of high level waste canisters that will have to be produced by the Hanford Tank Waste Treatment and Immobilization Plant, supplemental waste treatment technologies are being investigated. One such technology is the Near-Tank Treatment System, which uses continuous sludge leaching, filtration, and ion exchange to process the waste in a simple, compact system. The Near Tank Treatment System is ideally suited for handling Hanford tanks with large amounts of boehmite, a difficult aluminum phase to dissolve. A pilot-scale Near Tank Treatment System was constructed and tested with a boehmite and iron oxyhydroxide waste simulant to evaluate the robustness and effectiveness of the system. The data from the pilot-scale tests were also used to assess scale-up from previously performed bench-scale tests. It should be noted that any work involving the use of simulated HLW has inherent limitations. For this work, every attempt was made to ensure that the simulant mimicked the actual waste performance as closely as possible. However, there are always limitations in the ability to The NTTS Demonstration Test established that all the subsystems could be operated concurrently to process the waste simulant. The NTTS had a stable performance during the Demonstration Test that required very little external manipulation once a steady state was achieved. The CSL demonstrated effectively 90% dissolution of the hard to leach boehmite phase. The cross flow filtration system was able to deliver decontaminated salt solution to the NTCR system. The NTCR system exceeded the design basis by providing effluent below the detection limit beyond the design basis required time. The NTTS system was successfully demonstrated and has shown that leaching and decontamination of the subsequent permeate can be readily achieved using relatively small footprint equipment in an at tank application. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot-Scale CFP Commissioning: Creative Problem Solving and Lessons Learned

We have commissioned a pilot-scale, ex-situ catalytic fast pyrolysis (CFP) reactor system in the Thermal and Catalytic Process Development Unit (TCPDU) at the National Renewable Energy Laboratory. The FCC-style CFP system, including a riser and continuous regeneration, was added to the existing half-ton-per-day biomass fast pyrolysis unit and was designed to run a zeolite-type catalyst. The system is unique due to its scale and catalyst flow control scheme. As the design of this system was informed by early data from a bench-scale reactor, several technical scale-up challenges had to be overcome. Additionally, physical constraints and the complexities of biomass vapors required and inspired creative solutions. This talk will discuss the specific challenges we found and addressed, including an oxygen deficiency in the regenerator and plugging in the exit streams. We explored several options for increasing oxygen availability and selected a cyclone-catalyst return design on the exit line so we could increase air flow through the regenerator. We found that hot gas filtration is essential in any exit streams containing water vapor and trace amounts of catalyst; any combination of catalyst and condensate quickly makes mud that plugs equipment and severely limits run time. Duplicate filters are also required to extend run time. Most of the equipment and solutions were designed and installed by our team of engineers and technicians, working closely together in an iterative process to design, install, operate, then redesign. Collaborations with other national laboratories with computational fluid dynamics expertise helped inform designs and identify creative solutions to these scale-up challenges. Ultimately, data from the reactor system will be used to validate a comprehensive kinetic model of CFP that can be used to better design and inform new systems at various scales.

09 BIOMASS FUELS↗

Topological and Dynamical Representations for Radio Frequency Signal Classification

Radio Frequency (RF) signals are found throughout our world, carrying over-the-air information for both digital and analog uses with applications ranging from WiFi to the radio. One area of focus in RF signal analysis is determining the modulation schemes employed in these signals which is crucial in many RF signal processing domains from secure communication to spectrum monitoring. This work investigates the accuracy and noise robustness of novel Topological Data Analysis (TDA) and dynamic representation based approaches paired with a small convolution neural network for RF signal modulation classification with a comparison to state-of-the-art deep neural network approaches. We show that using TDA tools, like Vietoris-Rips and lower star filtrations, and the Takens' embedding in conjunction with a standard shallow neural network we can capture the intrinsic dynamical, geometric, and topological features of the underlying signal's manifold, offering informative representations of the RF signals. Our approach is effective in handling the modulation classification task and is notably noise robust, outperforming the commonly used deep neural network approaches in mode classification. Moreover, our fusion of dynamical and topological information is able to attain similar performance to deep neural network architectures with significantly smaller training datasets.

Myers, Audun D.↗

Elusive Structural, Functional, and Immunological Features of Act d 5, the Green Kiwifruit Kiwellin

Kiwellin (Act d 5) is an allergenic protein contained in kiwifruit pulp in high amounts. The purpose of this study was to investigate the three-dimensional structure of the natural molecule from green kiwifruit and its possible function. Kiwellin was crystallized, and its structure, including post-translational modifications, was elucidated. The molecular weight and structural features, in solution, were analyzed by gel filtration and circular dichroism, respectively. Although structurally similar to expansin, kiwellin lacks expansin activity and carbohydrate binding. A specific algorithm was applied to investigate any possible IgE reactivity correlation between kiwellin and a panel of 102 allergens, including expansins and other carbohydrate-binding allergens. The available data suggest a strong dependence of the kiwellin structure on the environmental/experimental conditions. This dependence therefore poses challenges in detecting the correlations between structural, functional, and immunological features of this protein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallization and preliminary X-ray diffraction analysis of recombinant phosphoribosylpyrophosphate synthetase from the Thermophilic thermus thermophilus strain HB27

Phosphoribosylpyrophosphate synthetases (PRPP synthetases) are among the key enzymes essential for vital functions of organisms and are involved in the biosynthesis of purine and pyrimidine nucleotides, coenzymes, and the amino acids histidine and tryptophan. These enzymes are used in biotechnology for the combined chemoenzymatic synthesis of natural nucleotide analogs. Recombinant phosphoribosylpyrophosphate synthetase I from the thermophilic strain HB27 of the bacterium Thermus thermophilus (T. th HB27) has high thermal stability and shows maximum activity at 75°Ð¡, due to which this enzyme holds promise for biotechnological applications. In order to grow crystals and study them by X-ray crystallography, an enzyme sample, which was produced using a highly efficient producer strain, was purified by affinity and gel-filtration chromatography. The screening of crystallization conditions was performed by the vapor-diffusion technique. The crystals of the enzyme suitable for X-ray diffraction were grown by the counter-diffusion method through a gel layer. These crystals were used to collect the X-ray diffraction data set at the SPring-8 synchrotron radiation facility (Japan) to 3-Å resolution. The crystals belong to sp. gr. P2{sub 1} and have the following unitcell parameters: a = 107.7 Å, b = 112.6 Å, c = 110.2 Å, α = γ = 90°, β = 116.6°. The X-ray diffraction data set is suitable for determining the three-dimensional structure of the enzyme at 3.0-Å resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gadolinium Oxalate Solubility Measurements in Nitric Acid Solutions

HB-Line will begin processing Pu solutions during FY2012 that will involve the recovery of Pu using oxalate precipitation and filtration. After the precipitation and filtration processes, the filtrate solution will be transferred from HB-Line to H-Canyon. The presence of excess oxalate and unfiltered Pu oxalate solids in these solutions create a criticality safety issue if they are sent to H-Canyon without controls in H-Canyon. One approach involves H-Canyon receiving the filtrate solution into a tank that is poisoned with soluble gadolinium (Gd). Decomposition of the oxalate will occur within a subsequent H-Canyon vessel. The receipt of excess oxalate into the H-Canyon receipt tanks has the potential to precipitate a portion of the Gd poison in the receipt tanks. Because the amount of Gd in solution determines the maximum amount of Pu solids that H-Canyon can receive, H-Canyon Engineering requested that SRNL determine the solubility of Gd in aqueous solutions of 4-10 M nitric acid (HNO 3 ), 4-12 g/L Gd, and 0.15-0.25 M oxalic acid (H 2 C 2 O 4 ) at 25 C. The target soluble Gd concentration is 6 g/L. The data indicate that the target can be achieved above 6 M HNO 3 and below 0.25 M H 2 C 2 O 4 . For 6 M HNO 3 , 10.5 g/L and 7 g/L Gd are soluble in 0.15 M and 0.25 M H 2 C 2 O 4 , respectively. In 4 M HNO 3 , the Gd solubility drops significantly to 2 g/L and 0.25 g/L in 0.15 M and 0.25 M H 2 C 2 O 4 , respectively. The solubility of Gd at 8-10 M HNO 3 exceeds the solubility at 6 M HNO 3 . The data for 4 M HNO 3 showed good agreement with data in the literature. To achieve a target of 6 g/L soluble Gd in solution in the presence of 0.15-0.25 M oxalate, the HNO 3 concentration must be maintained at or above 6 M HNO 3 .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The relationship between cadmium in kidney and cadmium in urine and blood in an environmentally exposed population

Introduction: Cadmium (Cd) is toxic to the kidney and a major part of the body burden occurs here. Cd in urine (U-Cd) and blood (B-Cd) are widely-used biomarkers for assessing Cd exposure or body burden. However, empirical general population data on the relationship between Cd in kidney (K-Cd), urine, and blood are scarce. Our objectives were to determine the relationship between cadmium in kidney, urine, and blood, and calculate the elimination half-time of Cd from the kidney. Methods: Kidney cortex biopsies, urine, and blood samples were collected from 109 living kidney donors. Cd concentrations were determined and the relationships between K-Cd, U-Cd, and B-Cd were investigated in regression models. The half-time of K-Cd was estimated from the elimination constant. Results: There was a strong association between K-Cd and U-Cd adjusted for creatinine (r{sub p} = 0.70, p < 0.001), while the association with B-Cd was weaker (r{sub p} = 0.44, p < 0.001). The relationship between K-Cd and U-Cd was nonlinear, with slower elimination of Cd at high K-Cd. Estimates of the K-Cd half-time varied between 18 and 44 years. A K-Cd of 25 μg/g corresponds to U-Cd of 0.42 μg/g creatinine in overnight urine (U-Cd/K-Cd ratio: about 1:60). Multivariate models showed Cd in blood and urinary albumin as determinants for U-Cd excretion. Discussion: In healthy individuals with low-level Cd exposure, there was a strong correlation between Cd in kidney and urine, especially after adjustment for creatinine. Urinary Cd was also affected by Cd in blood and urinary albumin. Previous estimates of the U-Cd/K-Cd ratio may underestimate K-Cd at low U-Cd. - Highlights: ► The first study of the relation between Cd in kidney, blood and urine at low U-Cd ► Simultaneous samples were collected from healthy kidney donors. ► There was a nonlinear relationship between cadmium in kidney and urine. ► Estimates of the kidney cadmium half-time were 18–44 years, depending on model used. ► Previous data seem to underestimate kidney cadmium at low urinary cadmium.

60 APPLIED LIFE SCIENCES↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

Analysis of Tank 35H Samples in Support of Salt Batch Planning

Savannah River Remediation obtained three samples from different heights within Tank 35H. The samples were analyzed by Savannah River National Laboratory to support Salt Batch planning. The results from the analysis indicate the compositions of the three samples show increasing concentrations for most analytes going from HTF-35-15-17 through HTF-35-15-19 corresponding to successively deeper sampling locations. The data indicate some stratification within the tank. The plutonium and Sr-90 concentrations measured in the filtered samples were slightly lower than in the decanted (unfiltered) samples. The difference in the results for the filtered and unfiltered samples likely lies within the expected uncertainty for the measurement, but may indicate that filtration removed a small amount of suspended material from the samples.