Search NASASearch

SEARCH · Search NASA

Results for “decision-making methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

349 records · Page 11

Eddy Covariance Theory: A Review

Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.

ecosystem fluxes

Solvent-Free Preparation of High Energy, Binder-Free Electrodes Enabled by Dry Compressible Holey Graphene

Graphene is an atomically thick sheet consisting of a graphitic carbon network with excellent mechanical strength, electrical and thermal conductivity, and chemical stability. Holey graphene, a structural derivative of graphene, has an array of through-the-thickness holes across the lateral surface of the nanosheet. The presence of these holes has minimal detrimental effect on the graphene properties and leads to enhanced performance in applications such as electronics, sensors, and energy storage. For example, these holes allow more facile cross-plane ion and gas transport than intact graphene, making holey graphene an ideal electrode material for electrochemical energy storage. This presentation will focus on the ability of holey graphene to be compression molded into robust articles or architectures under solvent-free conditions without the need for potentially parasitic binders. The unique dry compressibility of holey graphene has enabled facile fabrication of high mass loading electrodes with both high density and high porosity, which have found use in supercapacitors and various high-energy battery systems such as lithium-oxygen, lithium-sulfur, and lithium-selenium batteries.

Yi Lin

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation

Control of Thermo-Acoustics Instabilities: The Multi-Scale Extended Kalman Approach

"Multi-Scale Extended Kalman" (MSEK) is a novel model-based control approach recently found to be effective for suppressing combustion instabilities in gas turbines. A control law formulated in this approach for fuel modulation demonstrated steady suppression of a high-frequency combustion instability (less than 500Hz) in a liquid-fuel combustion test rig under engine-realistic conditions. To make-up for severe transport-delays on control effect, the MSEK controller combines a wavelet -like Multi-Scale analysis and an Extended Kalman Observer to predict the thermo-acoustic states of combustion pressure perturbations. The commanded fuel modulation is composed of a damper action based on the predicted states, and a tones suppression action based on the Multi-Scale estimation of thermal excitations and other transient disturbances. The controller performs automatic adjustments of the gain and phase of these actions to minimize the Time-Scale Averaged Variances of the pressures inside the combustion zone and upstream of the injector. The successful demonstration of Active Combustion Control with this MSEK controller completed an important NASA milestone for the current research in advanced combustion technologies.

Dzu K Le

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter

Coordinated Natural Gas and Electric Planning: Case Studies of Current Approaches and Practices

This paper examines how natural gas and electric utilities across eight U.S. states and two Canadian provinces are beginning to coordinate historically separate planning processes in response to growing system interdependencies, policy mandates, aging infrastructure, and changing customer energy choices. Electricity planning has long relied on robust integrated resource planning frameworks that weigh numerous objectives, risks, and costs. Natural gas planning, on the other hand, is typically less transparent and more narrowly focused on safety and system integrity. As economic, reliability, and policy drivers place new and shared demands on both systems, jurisdictions and utilities are experimenting with approaches such as coordinated forecasting, non pipeline alternatives, and combined planning pilots. A few have issued regulatory or statutory directives for greater data sharing and methodological alignment. Case studies from British Columbia, California, Colorado, Illinois, Massachusetts, Minnesota, New York, Québec, Rhode Island, and Washington illustrate a wide range of approaches to rethinking siloed planning. The paper identifies several common themes across the jurisdictions examined. It provides observations on the methods, processes, and organizational steps that may be needed in the future to address the challenges being faced by states and utilities. Lastly, it identifies some initial steps that states and utilities can consider if they would like to pursue more integrated, cost-effective, policy-aligned energy system planning.

03 NATURAL GAS

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Radiation-Resistant Ti/BN Coatings: Insights From 171 Days Exposure to Space Radiation and Atomic Oxygen in Low Orbit

Atmospheric Plasma Spray (APS) and Vacuum Plasma Spray (VPS) techniques were used to develop Ti/2 vol.% hBN coatings, for extreme space environments and tested aboard the International Space Station as part of the MISSE-17 (Materials International Space Station Experiments) program. The coatings were exposed to atomic oxygen, space radiation, and low-orbit thermal cycling. VPS coatings showed a 56% increase in microhardness, a 26% rise in elastic modulus, minimal porosity and crack density changes compared to APS coatings. The change in mechanical properties is attributed to the formation of TiO, TiO₂ and TiN from nitrogen retention, alongside radiation-induced dislocations, which enhanced surface hardening. The oxidation of titanium led to the formation of TiO and TiO₂, while boron nitride was retained and underwent transmutation in VPS coatings. XPS and EDS analyses confirmed the enhanced space-environment resistance of VPS coatings, making them ideal for long-term spacecraft protection in lunar and Martian conditions.

Abhijith Kunneparambil Sukumaran

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

AI-Batt (Autonomous Identification of Battery Life Models) [SWR 21-36]

Autonomous Identification of Battery Life Models (AI-Batt) AI-Batt is a MATLAB code base for developing lifetime models for batteries from accelerated aging data. The code base provides many functions for processing, visualizing, and modeling battery aging data, making the data processing, exploration, and modeling workflow substantially faster. These tools are tailored for working with battery aging data sets, which usually consist of many separate time-series for each cell, with many test conditions and possible replicates at each condition, which makes it difficult to simply process or visualize the data set. Complex modeling tasks, such as cross-validation, sensitivity analysis, and uncertainty quantification have been implemented to enable thorough statistical investigation of model predictions. Additionally, several machine-learning algorithms are implemented to autonomously identify suitable models via symbolic regression. Data processing functions automatically cast data from the struct data type, which is commonly used to store experimental data, but is not an acceptable input for most algorithms, to the table data type, which can be easily used as input to any optimization algorithm. Also, the data can be separated into time-invariant and time-variant data tables, which is helpful for exploring the data set as well as developing separate models for time-variant and time-invariant aging mechanisms. For example, in aging tests with constant temperature, temperature is a time-invariant experimental condition. Visualization tools enable plotting of data, model fits, and model simulations possible with single-line function calls, empowering data exploration of complex data sets with both time-varying and time-invariant trends. Plots can be automatically generated for the whole data set, or separated by data group (groups of test replicates) or individual data series. Data points or data series can be automatically colored by the value of a variable with a variety of color maps, and model predictions can also be colored by the value of a fit statistic. Comparisons between data sets and the predictions/simulations of different models on the same data set can be easily plotted as well. Distributions of parameter values from bootstrap resampling can be plotted to visualize the reliability of parameter estimation, or determine any correlations between parameters. Modeling tools handle the complex task of creating and parsing symbolic equations for modeling battery lifetime. Equations are parsed to grab relevant data variables, parameter values, or specified sub-models for input into optimization, evaluation, or simulation functions. Models can be optimized locally (one set of parameters for each data series), bi-level (some parameters shared across the data set), or globally (single set of parameters for all data). Functions implementing symbolic regression algorithms help users to discover effective model equations, even in poorly sampled, high-dimensional data.

Smith, Kandler [National Renewable Energy Lab. (NR

Multidisciplinary Design Optimization and Analysis of an Open Rotor Stage: Part 1

Successful design of open rotor propulsors requires effective analysis across multiple disciplines, including aerodynamics, acoustics, and structures. A viable design must not only be efficient but must also produce an acceptable level of noise and meet all static and dynamic structural requirements. For design and optimization, this is especially challenging because running high fidelity analyses is resource-intensive, and optimizing a design may require many thousands of cases to be analyzed. For this reason, the NASA team has applied design methodology that utilizes low-cost aerodynamic methods, machine learning models, and high-fidelity analyses when necessary. This includes standard two-dimensional methods such as throughflow analysis and quasi-3D blade-to-blade CFD, as well as some newly developed methods. Optimization using 3D CFD is necessary to maximize performance, and this is considered as well. All optimizations are carried out subject to structural constraints evaluated using finite element analysis. Doing this accurately requires a robust trunnion design, capable of pitching the blade between cruise and takeoff conditions while maintaining acceptable factor of safety. Hot to cold analysis must also be applied in order to correctly determine the as-manufactured shape. For acoustics, the unsteady pressures on the blade surfaces must be predicted, and this can be done either through full-annulus unsteady CFD or through a nonlinear harmonic method (NLH). NLH can run much faster, allowing some acoustic considerations to be made earlier in the design process. The design process is ongoing, and this presentation will review the current status and planned next steps. This part of the talk will focus on aerodynamic performance and be followed by a talk on structures and acoustics.

Design

Advanced Materials for the Lunar Surface: Multiscale Computational Design of Refractory Alloys and Carbides

Emerging operational environments, such as the lunar surface, present novel challenges for NASA and drive the need for advanced materials in applications like fission surface power systems. To address these demands, computational materials science is rapidly evolving to augment or replace costly and hazardous empirical testing. Although materials selection at NASA remains predominantly experimentally driven, advanced simulation methodologies are being steadily integrated into the engineering lifecycle. This work details the application of multiscale simulation techniques—including first-principles calculations, CALPHAD, dislocation dynamics, and molecular dynamics—at NASA's Ames Research Center to evaluate advanced materials for extreme environments. First, we present contributions to the Space Nuclear Propulsion Project. Be-cause propellant channel coatings in nuclear thermal rockets must withstand high-pressure, high-temperature hydro-gen, optimizing these materials is critical. First-principles calculations were employed to establish a rigorous quantitative and qualitative understanding of the behavior of the refractory carbides ZrC, NbC, and their mixtures in high-enthalpy hydrogen environments. This necessitated the generation of high-fidelity thermodynamic models for both stoichiometric and carbon-depleted carbides, both with and without the presence of hydrogen. Furthermore, we highlight efforts under the Refractory Alloy Additive Manufacturing Build Optimization (RAAMBO) project, where existing and novel alloy compositions were assessed for additive manufacturing printability and subsequent performance in applications such as heat pipes and rocket nozzle extensions. This was accomplished through a comprehensive multiscale simulation framework that bridged the gap from the nanometer to the millimeter scale. Across both initiatives, rigorous validation against empirical data was prioritized. By systematically employing a verified and validated computational frame-work, we demonstrate how simulation effectively supports multidisciplinary engineering efforts, builds project-wide confidence, and drives critical materials development.

computational materials

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot