Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Discrete models of fluids: spatial averaging, closure and model reduction

We consider semidiscrete ODE models of single-phase fluids and two-fluid mixtures. In the presence of multiple fine-scale heterogeneities, the size of these ODE systems can be very large. Spatial averaging is then a useful tool for reducing computational complexity of the problem. The averages satisfy exact balance equations of mass, momentum, and energy. These equations do not form a satisfactory continuum model because evaluation of stress and heat flux requires solving the underlying ODEs. To produce continuum equations that can be simulated without resolving microscale dynamics, we recently proposed a closure method based on the use of regularized deconvolution. Here we continue the investigation of deconvolution closure with the long term objective of developing consistent computational upscaling for multiphase particle methods. The structure of the fine-scale particle solvers is reminiscent of molecular dynamics. For this reason we use nonlinear averaging introduced for atomistic systems by Noll, Hardy, and Murdoch-Bedeaux. We also consider a simpler linear averaging originally developed in large eddy simulation of turbulence. We present several simple but representative examples of spatially averaged ODEs, where the closure error can be analyzed. Based on this analysis we suggest a general strategy for reducing the relative error of approximate closure. For problems with periodic highly oscillatory material parameters we propose a spectral boosting technique that augments the standard deconvolution and helps to correctly account for dispersion effects. We also conduct several numerical experiments, one of which is a complete mesoscale simulation of a stratified two-fluid flow in a channel. In this simulation, the operation count per coarse time step scales sublinearly with the number of particles.

Multiscale modeling, discrete models, fluid flow↗

Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

Abstract. Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radioxenon production through neutron irradiation of stable xenon gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

ARSA↗

The deep-DRT: A deep neural network approach to deconvolve the distribution of relaxation times from multidimensional electrochemical impedance spectroscopy data

Electrochemical impedance spectroscopy (EIS) is an experimental technique ubiquitously used to study electrochemical systems. However, conventional EIS data interpretation through physical and equivalent circuit models is challenging because physical models are problem-specific, and equivalent circuits are often just lumped-element analogs lacking physical meaning. The distribution of relaxation times (DRT) has emerged as a complementary approach to resolve these issues. One drawback of conventional DRT deconvolution is that the EIS data is understood to be (only) a function of frequency (i.e. 1D data) and deconvolved accordingly. This work proposes a novel deconvolution method based on deep neural networks (DNNs), allowing the analysis of multidimensional EIS spectra to bridge data dependency on both frequencies and experimental conditions. Two particularly appealing traits of the deep-DRT method developed in this article are that neither regularization nor specific spacing on the state variables defining the experiment are required. Finally, leveraging DNN to examine complex EIS spectra and their dependence on experimental conditions, this work opens a new research direction in the area of EIS analysis and DRT deconvolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dimension reduction method for ODE fluid models

We develop a dimension reduction method for large size ODE systems obtained from a dis- cretization of partial differential equations of viscous fluid flow of nearly constant density. The method is also applicable to other large size classical particle systems with negligibly small variations of concentration. We propose a new computational closure for mesoscale balance equations based on numerical iterative deconvolution. To illustrate the computa- tional advantages of the proposed reduction method we use it to solve a system of Smoothed Particle Hydrodynamic ODEs describing Poiseuille flows driven by uniform and periodic (in space) body forces. For the Poiseuille flow driven by the uniform force the coarse solution was obtained with the zero-order deconvolution. For the flow driven by the periodic body force, the first-order deconvolution was necessary to obtain a sufficiently accurate solution.

dimension reduction↗

An artificial intelligence’s interpretation of complex high-resolution in situ transmission electron microscopy data

Complicated nano- and atomic-scale processes with sub-angstrom spatial resolution and millisecond time resolution visualized by in situ transmission electron microscopy (TEM) are often highly dynamical and time consuming to analyze and interpret. Here, we report how variational autoencoders (VAEs) can provide an artificial intelligence’s interpretation of high-resolution in situ TEM data by condensing and deconvoluting complicated atomic-scale dynamics into a latent space with reduced dimensionality. We designed a VAE model with high latent dimensions capable of deconvoluting information from complex high-resolution TEM data. We demonstrate how this model, with high latent dimensions trained on atomically resolved TEM images of lead sulfide (PbS) nanocrystals, is able to capture movements and perturbations of periodic lattices in both simulated and real in situ TEM data. Importantly, the VAE model shows the capability of detecting and deconvoluting dynamical nanoscale physical processes, such as the rotation of crystal lattices and intra-particle ripening during the annealing of semiconductor nanocrystals.

47 OTHER INSTRUMENTATION↗

Mammograms restoration by using Wiener filter

Restoration of digital mammograms, as a pre-processing tool, using deconvolution procedures, is analysed. It implies, knowing Modulation Transfer Function (MTF) of the mammography device and the estimation of the mammogram’s noise. Wiener filter is used, as the most objective in mammograms restoration by deconvolution. Using MATLAB program the deconvolution procedures are conducted in two ways with different level of approximation. The first method approximates the noise/signal power ratio by a constant and the second method uses autocorrelation functions of the noise and signals. Abilities and limitations of the methods are analysed and checked by using the raw images of the bar-pattern due to better visualisation of the obtained results. The raw images are obtained at a Computed Radiography (CR) mammography device in Clinical Centre in Podgorica. It is found that quality of the restored image highly depends of knowledge of type and magnitude of noise. In the both methods spatial resolution of the restored images are improved, but much better in a case where autocorrelation functions of the noise and signal are used. This procedure is proposed as an objective pre-processing tool to put back imperfectness of mammography devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interface properties and built-in potential profile of a LaCr O 3 / SrTi O 3 superlattice determined by standing-wave excited photoemission spectroscopy

LaCrO 3 (LCO)/SrTiO 3 (STO) heterojunctions are intriguing due to a polar discontinuity along [001], exhibiting two distinct and controllable charged interface structures [(LaO) + /(TiO 2 ) 0 and (SrO) 0 /(CrO 2 ) - ] with induced polarization, and a resulting depth-dependent potential. In this study, we have used soft- and hard-x-ray standing-wave excited photoemission spectroscopy (SW-XPS) to quantitatively determine the elemental depth profile, interface properties, and depth distribution of the polarization-induced built-in potentials. We observe an alternating charged interface configuration: a positively charged (LaO) + /(TiO 2 ) 0 intermediate layer at the LCO top /STO bottom interface and a negatively charged (SrO) 0 /(CrO 2 ) - intermediate layer at the STO top /LCO bottom interface. Using core-level SW data, we have determined the depth distribution of species, including through the interfaces, and these results are in excellent agreement with scanning transmission electron microscopy and electron energy-loss spectroscopy mapping of local structure and composition. SW-XPS also enabled deconvolution of the LCO and STO contributions to the valence-band (VB) spectra. Using a two-step analytical approach involving first SW-induced core-level binding-energy shifts and then VB modeling, the variation in potential across the complete superlattice is determined in detail. As a result, this potential is in excellent agreement with density functional theory models, confirming this method as a generally useful tool for interface studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-299: Small Fields Profiles Correction Through Detectors Spatial Response Functions and Field Size Dependence Analysis

Purpose: To calculate the spatial response function of various radiation detectors, to evaluate the dependence on the field size and to analyze the small fields profiles corrections by deconvolution techniques. Methods: Crossline profiles were measured on a Novalis Tx 6MV beam with a HDMLC. The configuration setup was SSD=100cm and depth=5cm. Five fields were studied (200×200mm2,100×100mm2, 20×20mm2, 10×10mm2and 5×5mm2) and measured were made with passive detectors (EBT3 radiochromic films and TLD700 thermoluminescent detectors), ionization chambers (PTW30013, PTW31003, CC04 and PTW31016) and diodes (PTW60012 and IBA SFD). The results of passive detectors were adopted as the actual beam profile. To calculate the detectors kernels, modeled by Gaussian functions, an iterative process based on a least squares criterion was used. The deconvolutions of the measured profiles were calculated with the Richardson-Lucy method. Results: The profiles of the passive detectors corresponded with a difference in the penumbra less than 0.1mm. Both diodes resolve the profiles with an overestimation of the penumbra smaller than 0.2mm. For the other detectors, response functions were calculated and resulted in Gaussian functions with a standard deviation approximate to the radius of the detector in study (with a variation less than 3%). The corrected profiles resolve the penumbra with less than 1% error. Major discrepancies were observed for cases in extreme conditions (PTW31003 and 5×5mm2 field size). Conclusion: This work concludes that the response function of a radiation detector is independent on the field size, even for small radiation beams. The profiles correction, using deconvolution techniques and response functions of standard deviation equal to the radius of the detector, gives penumbra values with less than 1% difference to the real profile. The implementation of this technique allows estimating the real profile, freeing from the effects of the detector used for the acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-R-34: Quantitative Perfusion Measurement in Rectal Cancer Using Three Different Pharmacokinetic Models: Implications for Prospective Study Design

Purpose: To compare three different pharmacokinetic models for analysis of dynamic-contrast-enhanced (DCE)-CT data with respect to different acquisition times and location of region of interest. Methods: Eight rectal cancer patients with pre-treatment DCE-CTs were included. The dynamic sequence started 4–10seconds(s) after the injection of contrast agent. The scan included a 110s acquisition with intervals of 40×1s+15×3s+4×6s. An experienced oncologist outlined the tumor region. Hotspots with top-5%-enhancement were also identified. Pharmacokinetic analysis was performed using three different models: deconvolution method, Patlak model, and modified Toft’s model. Perfusion parameters as blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface-area-product (PS), volume transfer constant (Ktrans), and flux rate constant (Kep), were compared with respect to different acquisition times of 45s, 65s, 85s and 105s. Both hotspot and whole-volume variances were also assessed. The differences were compared using the Wilcoxon matched-pairs test and Bland-Altman plots. Results: Moderate correlation was observed for various perfusion parameters (r=0.56–0.72, p<0.0001) but the Wilcoxon test revealed a significant difference among the three models (P < .001). Significant differences in PS were noted between acquisitions of 45s versus longer time of 85s or 105s (p<0.05) using Patlak but not with the deconvolution method. In addition, measurements varied substantially between whole-volume vs. hotspot analysis. Conclusion: The radiation dose of DCE-CT was on average 1.5 times of an abdomen/pelvic CT, which is not insubstantial. To take the DCE-CT forward as a biomarker in oncology, prospective studies should be carefully designed with the optimal image acquisition and analysis technique. Our study suggested that: (1) different kinetic models are not interchangeable; (2) a 45s acquisition might not be sufficient for reliable permeability measurement in rectal cancer using Patlak model, but might be achievable using deconvolution method; and (3) local variations existed inside the tumor, and both whole-volume-averaged and local-heterogeneity analysis is recommended for future quantitative studies. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

Comparison of methodologies used to determine aromatic lignin unit ratios in lignocellulosic biomass

Abstract Background Multiple analytical methods have been developed to determine the ratios of aromatic lignin units, particularly the syringyl/guaiacyl (S/G) ratio, of lignin biopolymers in plant cell walls. Chemical degradation methods such as thioacidolysis produce aromatic lignin units that are released from certain linkages and may induce chemical changes rendering it difficult to distinguish and determine the source of specific aromatic lignin units released, as is the case with nitrobenzene oxidation methodology. NMR methods provide powerful tools used to analyze cell walls for lignin composition and linkage information. Pyrolysis-mass spectrometry methods are also widely used, particularly as high-throughput methodologies. However, the different techniques used to analyze aromatic lignin unit ratios frequently yield different results within and across particular studies, making it difficult to interpret and compare results. This also makes it difficult to obtain meaningful insights relating these measurements to other characteristics of plant cell walls that may impact biomass sustainability and conversion metrics for the production of bio-derived fuels and chemicals. Results The authors compared the S/G lignin unit ratios obtained from thioacidolysis, pyrolysis-molecular beam mass spectrometry (py-MBMS), HSQC liquid-state NMR and solid-state (ss) NMR methodologies of pine, several genotypes of poplar, and corn stover biomass. An underutilized approach to deconvolute ssNMR spectra was implemented to derive S/G ratios. The S/G ratios obtained for the samples did not agree across the different methods, but trends were similar with the most agreement among the py-MBMS, HSQC NMR and deconvoluted ssNMR methods. The relationship between S/G, thioacidolysis yields, and linkage analysis determined by HSQC is also addressed. Conclusions This work demonstrates that different methods using chemical, thermal, and non-destructive NMR techniques to determine native lignin S/G ratios in plant cell walls may yield different results depending on species and linkage abundances. Spectral deconvolution can be applied to many hardwoods with lignin dominated by S and G units, but the results may not be reliable for some woody and grassy species of more diverse lignin composition. HSQC may be a better method for analyzing lignin in those species given the wealth of information provided on additional aromatic moieties and bond linkages. Additionally, trends or correlations in lignin characteristics such as S/G ratios and lignin linkages within the same species such as poplar may not necessarily exhibit the same trends or correlations made across different biomass types. Careful consideration is required when choosing a method to measure S/G ratios and the benefits and shortcomings of each method discussed here are summarized.

09 BIOMASS FUELS↗

RISE: robust iterative surface extension for sub-nanometer X-ray mirror fabrication

Precision optics have been widely required in many advanced technological applications. X-ray mirrors, as an example, serve as the key optical components at synchrotron radiation and free electron laser facilities. They are rectangular silicon or glass substrates where a rectangular Clear Aperture (CA) needs to be polished to sub-nanometer Root Mean Squared (RMS) to keep the imaging capability of the incoming X-ray wavefront at the diffraction limit. The convolutional polishing model requires a CA to be extended with extra data, from which the dwell time is calculated via deconvolution. However, since deconvolution is very sensitive to boundary errors and noise, the existing surface extension methods can hardly fulfill the sub-nanometer requirement. On one hand, the figure errors in a CA were improperly modeled during the extension, leading to continuity issues along the boundary. On the other hand, uncorrectable high-frequency errors and noise were also extended. In this study, we propose a novel Robust Iterative Surface Extension (RISE) method that resolves these problems with a data fitting strategy. RISE models the figure errors in a CA with orthogonal polynomials and ensures that only correctable errors are fit and extended. Combined with boundary conditions, an iterative refinement of dwell time is then proposed to compensate the errors brought by the extension and deconvolution, which drastically reduces the estimated figure error residuals in a CA while the increase of total dwell time is negligible. To our best knowledge, RISE is the first data fitting-based surface extension method and is the first to optimize dwell time based on iterative extension. An experimental verification of RISE is given by fabricating two elliptic cylinders (10 mm × 80 mm CAs) starting from a sphere with a radius of curvature around 173 m using ion beam figuring. The figure errors in the two CAs greatly improved from 204.96 nm RMS and 190.28 nm RMS to 0.62 nm RMS and 0.71 nm RMS, respectively, which proves that RISE is an effective method for sub-nanometer level X-ray mirror fabrication.

36 MATERIALS SCIENCE↗

Value Added Products from Renewable Biofuels

Cellulosic ethanol is an emerging biofuel that will make strong contributions to American domestic energy needs. In the US midwest the standard method for pretreatment of biomass uses hot acid to deconstruct lignocellulose. While other methods work, they are not in common use. Therefore it is necessary to work within this context to achieve process improvements and reductions in biofuel cost. Technology underlying this process could supplement and even replace commodity enzymes with engineered microbes to convert biomass-derived lignocellulose feedstocks into biofuels and valueadded chemicals. The approach that was used here was based on consolidated bioprocessing. Thermoacidophilic microbes belonging to the Domain Archaea were evaluated and modfied to promote deconvolution and saccharification of lignocellulose. Biomass pretreatment (hot acid) was combined with fermentation using an extremely thermoacidophilic microbial platform. The identity and fate of released sugars was controlled using metabolic blocks combined with added biochemical traits where needed. LC/MS analysis supported through the newly established Nebraska Bioenergy Facility provided general support for bioenergy researchers at the University of Nebraska. The primary project strategy was to use microbes that naturally flourish in hot acid (thermoacidophiles) with conventional biomass pretreatment that uses hot acid. The specific objectives were: to screen thermoacidophilic taxa for the ability to deconvolute lignocellulose and depolymerize associated carbohydrates; evaluate and respond to formation of “inhibitors” that arose during incubation of lignocellulose under heated acidic conditions; identify and engineer “sugar flux channeling and catabolic blocks” that redirect metabolic pathways to maximize sugar concentrations; expand the hydrolytic capacity of extremely thermoacidophilic microbes through the addition of deconvolution traits; and establish the Nebraska Bioenergy Facility (NBF) at the University of Nebraska-Lincoln.

09 BIOMASS FUELS↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

Using photoelectron spectroscopy to measure resonant inelastic X-ray scattering: a computational investigation

Resonant inelastic X-ray scattering (RIXS) has become an important scientific tool. Nonetheless, conventional high-resolution (few hundred meV or less) RIXS measurements, especially in the soft X-ray range, require low-throughput grating spectrometers, which limits measurement accuracy. Here, the performance of a different method for measuring RIXS, i.e. photoelectron spectrometry for analysis of X-rays (PAX), is computationally investigated. This method transforms the X-ray measurement problem of RIXS to an electron measurement problem, enabling use of high-throughput, compact electron spectrometers. X-rays to be measured are incident on a converter material and the energy distribution of the resultant photoelectrons, the PAX spectrum, is measured with an electron spectrometer. A deconvolution algorithm for analysis of such PAX data is proposed. It is shown that the deconvolution algorithm works well on data recorded with ~0.5 eV resolution. Additional simulations show the potential of PAX for estimation of RIXS features with smaller widths. For simulations using the 3d levels of Ag as a converter material, and with 10 5 simulated detected electrons, it is estimated that features with a few hundred meV width can be accurately estimated in a model RIXS spectrum. For simulations using a sharp Fermi edge to encode RIXS spectra, it is estimated that one can accurately distinguish 100 meV FWHM peaks separated by 45 meV with 10 5 simulated detected electrons that were photoemitted from within 0.4 eV of the Fermi level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variational Dirichlet Blur Kernel Estimation

Blind image deconvolution involves two key objectives: 1) latent image and 2) blur estimation. For latent image estimation, we propose a fast deconvolution algorithm, which uses an image prior of nondimensional Gaussianity measure to enforce sparsity and an undetermined boundary condition methodology to reduce boundary artifacts. For blur estimation, a linear inverse problem with normalization and nonnegative constraints must be solved. However, the normalization constraint is ignored in many blind image deblurring methods, mainly because it makes the problem less tractable. In this paper, we show that the normalization constraint can be very naturally incorporated into the estimation process by using a Dirichlet distribution to approximate the posterior distribution of the blur. Making use of variational Dirichlet approximation, we provide a blur posterior approximation that considers the uncertainty of the estimate and removes noise in the estimated kernel. Furthermore, experiments with synthetic and real data demonstrate that the proposed method is very competitive to the state-of-the-art blind image restoration methods.

97 MATHEMATICS AND COMPUTING↗

1 H NMR metabolomics study of spleen from C57BL/6 mice exposed to gamma radiation

Due to the potential risk of accidental exposure to gamma radiation, it’s critical to identify the biomarkers of radiation exposed creatures. In the present study, NMR based metabolomics combined with multivariate data analysis to evaluate the metabolites changed in the C57BL/6 mouse spleen after 4 days whole body exposure to 3.0 Gy and 7.8 Gy gamma radiations. Principal component analysis (PCA) and orthogonal projection to latent structures analysis (OPLS) are employed for classification and identification potential biomarkers associated with gamma irradiation. Two different strategies for NMR spectral data reduction (i.e., spectral binning and spectral deconvolution) are combined with normalize to constant sum and unit weight before multivariate data analysis, respectively. The combination of spectral deconvolution and normalization to unit weight is the best way for identifying discriminatory metabolites between the irradiation and control groups. Normalized to the constant sum may achieve some pseudo biomarkers. PCA and OPLS results shown that the exposed groups can be well separated from the control group. Leucine, 2-aminobutyrate, valine, lactate, arginine, glutathione, 2-oxoglutarate, creatine, tyrosine, phenylalanine, π-methylhistidine, taurine, myoinositol, glycerol and uracil are significantly elevated while ADP is decreased significantly. As a result, these significantly changed metabolites are associated with multiple metabolic pathways and may be potential biomarkers in the spleen exposed to gamma irradiation.

1H NMR metabolomics↗