Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Snow and Water Imaging Spectrometer: Final Instrument Characterization

The Snow and Water Imaging Spectrometer (SWIS) is a science-grade imaging spectrometer and telescope system suitable for CubeSat applications, spanning a 350-1700 nm spectral range with 5.7 nm sampling, a 10 degree field of view and 0.3 mrad spatial resolution. The system operates at F/1.8, providing high throughput for low-reflectivity water surfaces, while avoiding saturation over bright snow or clouds. The SWIS design utilizes heritage from previously demonstrated instruments on airborne platforms, while advancing the state of the art in compact sensors of this kind in terms of size and spectral coverage. Through frequent repeat observations from space at a moderate spatial resolution, SWIS can address key science questions concerning aquatic and terrestrial ecosystem changes, cryosphere warming and melt behavior, cloud and atmospheric science, and potential impacts of climate change and human activities on the environment. We review the optical design and innovations and key technologies developed for this instrument, as well as its measured optical performance. We discuss the radiometric calibration characterization, including detector linearity, flat field correction, and SNR. Finally, we discuss stray light modeling and the development of a focused ghost removal algorithm, which is tested and supported by laboratory results.

Bellardo, John↗

Fitting Leak Test Report: Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

EXECUTIVE SUMMARY Mechanically connected joints used in cryogenic fluid lines as part of space flight elements need to survive launch vibrations and remain leak-free to minimize the loss of on-board commodity and hazardous gas accumulation. In 2020, a cryogenic test apparatus was developed which can evaluate the leak performance of pressurized threaded fluid fittings. The fittings were mounted in the TVAC and cooled to cryogenic test temperature and pressurized with helium while the leak rate was measured using a calibrated GHe leak detector. The test articles for the initial proof of concept testing were ¼ and 1 inch Swagelok VCR fittings with three different types of seal rings copper, nickel, and Ni. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles, followed by exposure to a launch vibration profile at ambient temperature, after which two additional TVAC cycle tests were performed. The testing reported here is a continuation of the 2020 tests with a statistically significant large number of samples and test runs. Three Swagelok VCR fitting sizes were tested ¼, ½ and 1 inch, and five (5) samples of each fitting size, each sample was tested with SST and Ni seal rings (Total of 30 unique test articles). Each test article was subjected to four (4) thermal cycles. Half of these cycles were performed before vibration testing and half were performed after vibration testing. The vibration testing was performed to evaluate the ability of the fittings to survive launch-type vibration profiles and remain leak-free. Leak checking of each fitting was completed at temperatures between 20K – 30K. The test procedure in Section 8.0 was designed to facilitate a qualification test program by allowing a higher test throughput rate coupled with repeatable test profiles. Results were very positive and show that out of the 30 samples they all passed with leak rates a factor of 2-3 lower than the established 10-6sccs GHe leak threshold. The result showed the Ni seals had lower leak rate, but the SST was more rugged. There were two deviations where damage to the Ni seal ring during assembly resulted in a leaky fitting, this is discussed in Section 10.7 Test Deviations. These fittings show great promise for space flight use and further testing is recommended to fully qualify the fittings per the ASTM F1387-19 and/or other relevant NASA specifications. The test equipment hardware and software capability developed for this testing is generic and not restricted to VCR fittings. It can be employed to evaluate/qualify the leak performance of other types of fittings and a wide range of other cryogenic fluid components such as valves, gages, connectors, etc.

Cryogenic↗

Pre-Launch Calibration and Validation of the Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) Instrument

The Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) is a new imaging polarimeter instrument capable of sampling a single Earth target from up to 120 viewing angles, in four spectral channels, and in three linear polarization states across a 114° field of view (FOV). AirHARP is telecentric in the image space and simultaneously images three linear polarization states with no moving parts. These two aspects of the design allow for a simple and efficient quantitative calibration. Using coefficients derived at the center of the lens and the detector flatfields, we can calibrate the entire AirHARP sensor in a variety of laboratory, field, and space environments. We show that this telecentric calibration technique yields a 1σ absolute uncertainty of 0.25 % in degree of linear polarization (DOLP) in the laboratory for all channels and for pixels around the optical axis. To validate across the FOV, we compare our multi-angle reflectance and polarization data with the Research Scanning Polarimeter (RSP) over targets sampled during the NASA Aerosol Characterization from Polarimeter and Lidar (ACEPOL) campaign. We use the error-normalized difference technique to estimate how well the instruments compare relative to their error models. We find that AirHARP and the RSP reasonably agree for reflectance and DOLP within 2 standard deviations of their mutual uncertainty at 550, 670, and 870 nm and over a limited set of ocean and desert scenes. This calibration technique makes the Hyper-Angular Rainbow Polarimeter (HARP) design attractive for new spaceborne climate missions: HARP CubeSat (2020–2022), HARP2 (2024–) on the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE), and beyond.

Airborne Hyper-Angular Rainbow Polarimeter↗

An accelerator test of semi-empirical cross-sections

Experimentally measured yields of isotopes of elements from Mg to K resulting from the fragmentation of Ar-40 are compared with calculated yields based on semiempirical cross-section formulas. Excellent mass resolution is obtained in measurements using a beam of 287 MeV/amu Ar-40 incident on a CH2 target. The resolution is made possible by an Si(Li) detector telescope. Whereas the general agreement between calculation and experiment is good, with an rms difference of approximately 24 percent, attention is called to certain significant differences. It is found that important information for refining the semiempirical calculation of fragmentation cross sections can be obtained from data collected during the calibration of cosmic ray detector systems when such calibrations are performed under suitable conditions.

Lau, K. H.↗

Dose Calibration of the ISS-RAD Fast Neutron Detector

The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of 10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

Zeitlin, C.↗

Electron calibration on a high-energy cosmic ray detector.

The response of the GSFC High Energy Cosmic Ray Detector has been studied using electrons in the energy range from 5.4 to 18 GeV. A semiempirical analytic form has been developed to determine the starting points and the energies of electron-induced cascade showers. The energy resolution thus obtained has a full width at half maximum of 17%, and the starting point can be determined to within 0.1 to 0.2 radiation length. The results of this response calibration provide a basis on which cosmic ray electrons can be reliably identified and analyzed in the presence of a large proton background.

Crannell, C. J.↗

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0.3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.

detectors↗

Calibrating the IXPE Observatory from Ground to Space

The Imaging X-ray Polarimetry Explorer (IXPE) will be the next SMEX mission launched by NASA in 2021 in collaboration with the Italian Space Agency (ASI). IXPE will perform groundbreaking measurements of imaging polarization in X-rays for a number of different classes of sources with three identical telescopes, finally (re)opening a window in the high energy Universe after more than 40 years since the first pioneering results. The unprecedented sensitivity of IXPE to polarization poses peculiar requirements on the payload calibration, e.g. the use of polarized and completely unpolarized radiation, both on ground and in orbit, and can not rely on a systematic comparison with results obtained by previous observatories. In this paper, we will present the IXPE calibration plan, describing both calibrations which will be performed on the detectors at INAF-IAPS in Rome (Italy) and the calibration on the mirror and detector assemblies which will be carried out at Marshall Space Flight Center in Huntsville, Alabama. On orbit calibrations, performed with calibrations sources mounted on a filter wheel and placed in front of each detector when necessary, will be presented as well.

X-ray astronomy Polarimetry Calibratio↗

Multiple object fiber optic spectroscopy

The Steward Observatory of the University of Arizona employs short optical fiber lengths to bring light from galaxy images at the 2.3 m telescope's focus to a line along a spectrograph slit, thereby obtaining simultaneous spectra of many objects of the field of view. After describing this instrument, attention is given to the development of an improved version through which efficiency gains will be obtained by remotely positioning the fibers under computer control and by correctly matching fiber outputs to the spectrograph optics. A CCD will replace the presently employed image tube and photographic plate detector system, in order to permit sky subtraction, yield increased dynamic range, and provide more accurate wavelength calibration due to the detector's fixed format.

Hill, J. M.↗

On-Orbit Operation and Performance of MODIS Blackbody

MODIS collects data in 36 spectral bands, including 20 reflective solar bands (RSB) and 16 thermal emissive bands (TES). The TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic algorithm that relates the detector response with the calibration radiance from the sensor on-board blackbody (BB). The calibration radiance is accurately determined each scan from the BB temperature measured using a set of 12 thermistors. The BB thermistors were calibrated pre-launch with traceability to the NIST temperature standard. Unlike many heritage sensors, the MODIS BB can be operated at a constant temperature or with the temperature continuously varying between instrument ambient (about 270K) and 315K. In this paper, we provide an overview of both Terra and Aqua MODIS on-board BB operations, functions, and on-orbit performance. We also examine the impact of key calibration parameters, such as BB emissivity and temperature (stability and gradient) determined from its thermistors, on the TEB calibration and Level I (LIB) data product uncertainty.

Xiong, X.↗

Using APART for wall visibility calculations in the calibration channel of wide field planetary camera II

The cone visibility from the CCD detector array plane in the calibration channel of wide field planetary camera II (WFPC II) is analyzed, using APART, for three representative wavelengths as characterized by indices of refraction. The light pipe walls are visible from the corners of the equivalent CCD detector array when imaging with the smallest index of refraction, n = 1.375. Painting the inside of the light pipe walls will result in a decrease in their visibility.

Scholl, James W.↗

MODIS On-board Blackbody Performance

Currently, there are two MODIS instruments operated on-orbit: one on-board the Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. MODIS is a scanning radiometer that has 16 thermal emissive bands (TEBs) in the MWIR and LWIR regions. The remaining spectral bands are in the VISINIR and SWIR regions. The TEBs have a total of 160 detectors (10 detectors per band), which are calibrated on-orbit using an on-board blackbody (BB). MODIS TEB calibration is performed via a quadratic algorithm with its linear calibration coefficients updated on a scan-by-scan basis using each detector's response to the BB. The offset and nonlinear terms of the quadratic calibration equation are stored in a look-up table (LUT). The LUT parameters are derived from pre-launch calibration and updated on-orbit from BB observations, as needed. Typically, the BB is set at a fixed temperature. Periodically, a warm-up and cool-down activity is performed, which enables the BB temperature to be varied from instrument ambient up to 315K. The temperature of the BB is measured each scan using 12 thermistors, which were fully characterized pre-launch with reference to the NIST temperature scale. This paper describes MODIS on-board BB operational activities and performance. The TEB detector response (short-term stability and long-term changes) and noise characterization results derived from BB observations and their impact on the TEB calibration uncertainty are also presented.

Xiong, Xiaoxiong↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

Heterodyne efficiency for a coherent laser radar with diffuse or aerosol targets

The performance of a Coherent Laser Radar is determined by the statistics of the coherent Doppler signal. The heterodyne efficiency is an excellent indication of performance because it is an absolute measure of beam alignment and is independent of the transmitter power, the target backscatter coefficient, the atmospheric attenuation, and the detector quantum efficiency and gain. The theoretical calculation of heterodyne efficiency for an optimal monostatic lidar with a circular aperture and Gaussian transmit laser is presented including beam misalignment in the far-field and near-field regimes. The statistical behavior of estimates of the heterodyne efficiency using a calibration hard target are considered. For space based applications, a biased estimate of heterodyne efficiency is proposed that removes the variability due to the random surface return but retains the sensitivity to misalignment. Physical insight is provided by simulation of the fields on the detector surface. The required detector calibration is also discussed.

Frehlich, R. G.↗

Polarimetric calibration of the Multi-Angle Imager for Aerosols (MAIA)

NASA’s Multi-Angle Imager for Aerosols (MAIA) mission, under development at the Jet Propulsion Laboratory, is designed to study the adverse health effects of different types of particulate air pollution. Planned for launch in 2023 for a 3-year mission, the MAIA satellite instrument will focus on a selected set of metropolitan target areas, where air quality monitors and health data are available. Aerosol concentration and speciation are inferred from multi-angle measurements of backscattered sunlight in 14 spectral bands from 350-2200 nm, with bands near 442, 645 and 1040 nm measuring the degree (DoLP) and angle of linear polarization (AoLP) in addition to radiance. The pushbroom camera has a ~240-km cross-track field of view with a nadir resolution of ~200 m, and is mounted onto a biaxial gimbal to provide along-track view angles within ±60°, to extend the field of regard to ±48°, and to view the instrument’s onboard calibrator (OBC) and dark target. The OBC consists of a sunlit transmissive diffuser, followed by 12 polarizers at different orientations. MAIA’s polarimetry is implemented using miniature wire grid polarizers on the focal plane array, and dual photoelastic modulators (PEMs) and achromatic quarter-wave plates to rapidly rotate the polarization. The resulting ~26-Hz intensity modulation encodes the linearly polarized and total radiance in each pixel, leaving the DoLP and AoLP insensitive to gain calibration. We report on the polarimetric calibration of the MAIA camera using a vacuum-compatible polarization state generator, consisting of a 1600W Xenon lamp, 12-inch integrating sphere, and rotating high-extinction polarizer. Mueller-matrix-based calibration coefficients for each detector pixel are derived from measurements at multiple polarizer angles, and are used to correct the measurements for instrumental polarization aberrations. Prior to flight, the calibrated MAIA camera is panned across the OBC to characterize its output, using uniform illumination with an irradiance similar to the Sun.

Werne, Thomas↗

Design of an atmospheric sounding radiometer for the GOES meteorological satellite system

An advanced version of the visible infrared spin scan radiometer onboard U.S. geostationary operational environmental satellites was developed to add a vertical dimension to the instrument's infrared atmospheric images. Through the addition of twelve selectable narrow band filters and more precise in-flight calibration of the infrared detectors, the VISSR atmospheric sounder (VAS) will provide increased data to help determine the Earth's atmospheric temperature and water vapor distribution. The radiometer design, filter wheel, calibration shutter mechanisms, and their preflight test performance are discussed.

Jensen, R. G.↗

Low background spectral response of 30-130-micron detectors from blackbody measurements

Low background far infrared detector responsivity and low background spectral response calibrations can be performed simultaneously with a cooled, temperature-swept blackbody. This makes the use of a cooled, low background spectrometer unnecessary in many applications. Calibrations of a beryllium-doped germanium detector showing unwanted 100-micron response, and of a gallium-doped germanium detector, are described.

Moore, W. J.↗