Complementary Barrier Infrared Detector (CBIRD) Contact Methods

The performance of the CBIRD detector is enhanced by using new device contacting methods that have been developed. The detector structure features a narrow gap adsorber sandwiched between a pair of complementary, unipolar barriers that are, in turn, surrounded by contact layers. In this innovation, the contact adjacent to the hole barrier is doped n-type, while the contact adjacent to the electron barrier is doped p-type. The contact layers can have wider bandgaps than the adsorber layer, so long as good electrical contacts are made to them. If good electrical contacts are made to either (or both) of the barriers, then one could contact the barrier(s) directly, obviating the need for additional contact layers. Both the left and right contacts can be doped either n-type or ptype. Having an n-type contact layer next to the electron barrier creates a second p-n junction (the first being the one between the hole barrier and the adsorber) over which applied bias could drop. This reduces the voltage drop over the adsorber, thereby reducing dark current generation in the adsorber region.

Ting, David Z.↗

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.↗

System measures response time of photomultiplier tubes

Calibration system enables precise determination of rise time of photosensitive detectors. To perform a calibration, the time-voltage curve of the excitation voltage for a light source is compared with the time-voltage curve of the voltage output from a photosensitive detector which is responding to the light.

Lauver, M. R.↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

Performance characteristics of the imaging MAMA detector systems for SOHO, STIS, and FUSE/Lyman

Imaging Extreme Ultraviolet (EUV) Multi-Anode Microchannel Array (MAMA) detector systems with formats of 360 x 1024 pixels and pixel dimensions of 25 x 25 sq microns are being fabricated and tested for flight in two instruments on the ESA/NASA Solar and Heliospheric Observatory (SOHO). In addition, very-large-format (1024 x 1024)- and (2048 x 2048)-pixel Far Ultraviolet (FUV) and EUV MAMA detectors with pixel dimensions of 25 x 25 sq microns are being fabricated and tested for use in the NASA Goddard Space Flight Center's Hubble Space Telescope Imaging Spectrograph (STIS), a second-generation instrument scheduled for in-orbit installation in 1997. Finally, FUV MAMA detectors with formats of 224 x 960 pixels and pixel dimensions of 14 x 14 sq microns are being evaluated as prototypes of the detector for the prime FUV spectrograph of the Far Ultraviolet Spectroscopic Explorer (FUSE/Lyman) mission. The configurations and performance characteristics of the different detector systems are described, and the plans for further development of the Advanced Technology MAMA detector system discussed.

Timothy, J. G.↗

Performance of the Zero Degree Detector

The Zero Degree Detector (ZDD) is a large area pixelated silicon detector that measures secondary particle angular distributions from heavy ion interactions. The ZDD is part of the instrumentation being used in an ongoing measurement program to measure fragmentation cross-sections of heavy nuclei and evaluate the relative effectives of novel materials for spacecraft shielding. The initial performance of the ZDD has been assessed using the primary heavy ions measured. We report here on the ZDD's design, capabilities and signal calibration using heavy ions.

Christl, Mark J.↗

Small area silicon diffused junction X-ray detectors

The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.

Walton, J. T.↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Meeting the Grand Challenge of Protecting Astronauts Health: Electrostatic Active Space Radiation Shielding for Deep Space Missions

This report describes the research completed during 2011 for the NASA Innovative Advanced Concepts (NIAC) project. The research is motivated by the desire to safely send humans in deep space missions and to keep radiation exposures within permitted limits. To this end current material shielding, developed for low earth orbit missions, is not a viable option due to payload and cost penalties. The active radiation shielding is the path forward for such missions. To achieve active space radiation shielding innovative large lightweight gossamer space structures are used. The goal is to deflect enough positive ions without attracting negatively charged plasma and to investigate if a charged Gossamer structure can perform charge deflections without significant structural instabilities occurring. In this study different innovative configurations are explored to design an optimum active shielding. In addition, to establish technological feasibility experiments are performed with up to 10kV of membrane charging, and an electron flux source with up to 5keV of energy and 5mA of current. While these charge flux energy levels are much less than those encountered in space, the fundamental coupled interaction of charged Gossamer structures with the ambient charge flux can be experimentally investigated. Of interest are, will the EIMS remain inflated during the charge deflections, and are there visible charge flux interactions. Aluminum coated Mylar membrane prototype structures are created to test their inflation capability using electrostatic charging. To simulate the charge flux, a 5keV electron emitter is utilized. The remaining charge flux at the end of the test chamber is measured with a Faraday cup mounted on a movable boom. A range of experiments with this electron emitter and detector were performed within a 30x60cm vacuum chamber with vacuum environment capability of 10-7 Torr. Experiments are performed with the charge flux aimed at the electrostatically inflated membrane structure (EIMS) in both charged and uncharged configurations. The amount of charge shielding behind and around the EIMS was studied for different combinations of membrane structure voltages and electron energies. Both passive and active shielding were observed, with active shielding capable of deflecting nearly all incoming electrons. The pattern of charge distribution around the structure was studied as well as the stability of the structures in the charge flow. The charge deflection experiments illustrate that the EIMS remain inflated during charge deflection, but will experience small amplitude oscillations. Investigations were performed to determine a potential cause of the vibrations. It is postulated these vibrations are due to the charge flux causing local membrane charge distribution changes. As the membrane structure inflation pressure is changed, the shape responds, and causes the observed sustained vibration. Having identified this phenomenon is important when considering electrostatically inflated membrane structures (EIMS) in a space environment. Additionally, this project included a study of membrane material impacts, specifically the impact of membrane thickness. Extremely thin materials presented new challenges with vacuum preparation techniques and rapid charging. The thinner and lighter membrane materials were successfully inflated using electrostatic forces in a vacuum chamber. However, care must be taken when varying the potentials of such lighter structures as the currents can cause local heating and melting of the very thin membranes. Lastly, a preliminary analysis is performed to study rough order of magnitude power requirements for using EIMS for radiation shielding. The EIMS power requirement becomes increasingly more challenging as the spacecraft voltage is increased. As a result, the emphasis is on the deflection of charges away from the spacecraft rather than totally stopping them. This significantly alleviates the initial power requirements. With modest technological development(s) active shielding is emerging to be a viable option.

Radiation↗

Detection of long wavelength infrared at moderate temperatures

Technical approaches for the advanced development of 8-12 micrometer detectors operating at elevated temperatures were defined. The theoretical limits to performance of 8-12 micrometer quantum detectors (photoconductive and photovoltaic) and thermal detectors (pyroelectrics, bolometers etc). An analytic model of signal and noise in both quantum detectors and pyroelectric detectors was developed and candidate materials for both detector types were identified and examined. The present status of both quantum and thermal detectors was assessed as well as the parameters limiting operating temperature and detectivity. The areas of research and development likely to lead to detector performance near the theoretical limit are identified.

Tredwell, T. J.↗

Thin film thermal detector

Abnormally large variation of capacitance with temperature is obtained in thin film capacitors when a fixed ionic space charge is present in sufficient density in a dielectric film. This effect is the basis for a new kind of thin film thermal detector, whose performance at room temperature equals or exceeds that of comparable devices at much lower temperatures.

Maserjian, J.↗

The space telescope

Papers concerning the development of the Space Telescope which were presented at the Twenty-first Annual Meeting of the American Astronautical Society in August, 1975 are included. Mission planning, telescope performance, optical detectors, mirror construction, pointing and control systems, data management, and maintenance of the telescope are discussed.

Source record↗

Development of lightning current detector

A lightning current detector to record the maximum current amplitude of a lightning strike to the 150 meter weather tower at KSC was developed. The principle of operation of the detector is discussed, materials chosen to build the detector are described, and calibration tests performed on the detector are given. Field results of the detectors from two separate lightning strikes to the tower are included.

Livermore, S.↗

Design and performance of a modularized NaI/Tl/ detector /The Crystal Ball prototype/

A prototype NaI(Tl) detector (the Cluster of 54) of spherical geometry subtending a solid angle of 7.5% of 4pi at its center, has recently been assembled and tested. This detector consists of 54 close-packed but optically isolated NaI(Tl) modules and the associated electronic circuitry. The Cluster of 54 is the predecessor of an almost complete spherical detector, the Crystal Ball, which will cover 94% of 4pi. The latter detector is now under construction and is especially designed for the study of gamma-rays produced in electron-positron collisions at colliding beam facilities. This article outlines the mechanical, optical, and electronic assembly of the prototype system.

Chan, Y.↗

Investigation of effects of temperature, salinity, and electrode design on the performance of an electrochemical coliform detector

The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.

Grana, D. C.↗