Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SAS 3 survey of the soft X-ray background

The results of a survey of the soft X-ray sky in the C band (0.10-0.28keV) are reported. The observations were carried out using two independent flow proportional counters on board the SAS 3 X-ray satellite which had a total angular resolution of 2.9 deg FWHM, and a total exposure of 2.2 x 10 to the 4th per sq cm s sr. It is found that C band counting rates were generally inversely correlated with the column density of the neutral hydrogen on all angular scales down to the lowest angular resolution of the detectors. In the region 90-180 deg l and 0-10 deg b, the relation between C-band rates and the column densities of neutral hydrogen was fitted with a residual rms deviation of less than 13 percent by a two-component numerical model of the X-ray background. For the apparent attenuation column density a value of 2.7 x 10 to the 20th per sq cm was obtained. On the basis of a computer simulation of the SAS 3 data, it is shown that the observed clumping of interstellar matter was consistent with the magnitude of spatial fluctuations in the C-band map. When the background rates were subtracted from the survey map, the subsequent map showed foreground emission and absorption features with improved sensitivity and clarity. A series of computer-generated maps incorporating the SAS 3 data is given in an appendix.

Marshall, F. J.↗

MOSAIC

The Mosaicked Optical Self-scanned Array Imaging Camera (MOSAIC), is a 50 sq cm active area detector system encompassing 5.76 million picture elements. This camera is being developed for use in astronomical instrumentation requiring the use of large area imaging detectors with high resolution photon counting capability in the space ultraviolet. This paper gives a descriptive outline of the MOSAIC camera system including: the 100 mm diameter microchannel plate intensifier, the 3 x 3 array of 800 x 800 pixel charge coupled devices, the signal processing and buffer storage subsystem, the electronic support and control subsystem, and the data processing subsystem. Performance characteristics of the camera and its subsystems are presented, based on system analysis.

Williams, J. T.↗

Photographic film as a detector for solar X-ray/XUV astronomical applications

The characteristics of several films as detectors for solar soft X-ray (3-100 A) and XUV (100-600 A) radiation are discussed. The properties of soft-X-ray-sensitive films like the SO-212 make them useful for the glancing-incidence X-ray telescopes. Used for the MSFC X-Ray Telescope during the Skylab mission (at the wavelengths of 8.34 and 15.4 A), the SO-212 film functioned as a photon detector, achieving spatial resolution of 2.2 arc sec. Other high-resolution soft-X-ray-sensitive films include SO-242 and 101-07. For XUV detection, the SC-5, SC-7, 104-07, and 101-07 films are recommended.

Hoover, Richard B.↗

X-ray intensity and spectral variations in the BL Lac sources H2155-304 and PKS0548-322

The results from the X-ray observations of two BL Lacertae objects, H2155-304 and PKS0548-322, are presented. The observations were carried out with the HEAO-1 A2 Low Energy Detectors, the High Resolution Imager, and the Monitor Proportional Counter aboard the Einstein Observatory. Correlated X-ray intensity variations of about 20 percent in the 0.15-3.5 keV energy band and about 40 percent in the 1.5-10 keV energy band are observed in H2155-304 over a period of about 8 hr. A factor of two change in the intensity of PKS0548-322 in the 3.5-10 keV energy interval is also detected over a time interval of 1 hr. Variations in the X-ray intensity over a timescale of months and the hardening of the spectrum with increasing intensity are seen in the HEAO-1 A2 data on H2155-304. The shortest observed timescale for the variability is used to derive an upper limit on the mass of the central accreting source in the two BL Lac objects studied here.

Agrawal, P. C.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Digital optical spark chambers

The authors constructed and tested a prototype digital readout system for optical spark chambers using a linear, solid-state charge-coupled-device detector array. Position resolution of 0.013 mm (sigma) over a 25-cm field of view has been demonstrated. It is concluded that this technique should permit the construction of economical, lightweight and low-power trajectory hodoscopes for use in cosmic-ray instrumentation on balloons and in spacecraft.

Evenson, Paul↗

Fano-noise-limited CCDs

Recent developments of scientific CCDs have produced sensors that achieve ultra low read noise performance (less than 2 electrons rms) and near perfect charge transfer efficiency (0.9999996) without the addition of a fat-zero. This progress has now made it possible to achieve Fano-noise-limited performance in the soft X-ray where the detector's energy resolution is primarily limited by the statistical variation in the charge generated by the interacting X-ray photon. In this paper, Fano-noise-limited test data is presented for two different CCD types and a CCD derived estimate of the Fano factor is determined. By evaluating ultra low-modulation images (less than 1 electron peak-to-peak) it is shown that the CCD's global CTE is now superior to its read noise floor. To capitalize on this capability CCD manufacturers are now focusing their attention on reducing the noise floor below the 1 electron level thereby matching the sensor's CTE performance. This improvement, if accomplished, will push Fano-noise-limited performance for the CCD into the extreme ultra-violet.

Janesick, James↗

Studies of thermal wave phenomena on the Jovian planets

Ground based and Voyager observations of Jupiter have provided evidence that the tropospheric temperature shows global scale longitudinal variations which are often wavelike in character. Voyager data are reported to exhibit the presence of slowly moving thermal features, wherein the jovian tropospheric temperature patterns are not advected by the equatorial zonal winds, but are not found to rotate at the System III (interior) rate. Ground based data in a broad infrared band (8 to 13 micron) show a wavelike structure whose amplitude and spatial scale are similar to the reported properties of the slowly moving thermal features. This study is directed toward obtaining additional ground based data in infrared spectral bands whose contribution functions are optimized for specific atmospheric regions (tropospheric at 20 micron, and stratospheric at 7.8 micron), in order to confirm the previous results, and to identify the nature and physical significance of wavelike longitudinal temperature fluctuations on the Jovian planets. A 2-D infrared array detector and low resolution cryogenic grating spectrometer is being adapted to obtain maps in approx. 2/cm bandpasses.

Deming, Drake↗

Hard X-ray and gamma-ray imaging spectroscopy for the next solar maximum

The objectives and principles are described of a single spectroscopic imaging package that can provide effective imaging in the hard X- and gamma-ray ranges. Called the High-Energy Solar Physics (HESP) mission instrument for solar investigation, the device is based on rotating modulation collimators with germanium semiconductor spectrometers. The instrument is planned to incorporate thick modulation plates, and the range of coverage is discussed. The optics permit the coverage of high-contrast hard X-ray images from small- and medium-sized flares with large signal-to-noise ratios. The detectors allow angular resolution of less than 1 arcsec, time resolution of less than 1 arcsec, and spectral resolution of about 1 keV. The HESP package is considered an effective and important instrument for investigating the high-energy solar events of the near-term future efficiently.

Hudson, H. S.↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

HEAO-1 and BBXRT non-source X-ray observations

A more appropriate title for this talk would have been 'Measurements of Large Scale Structure from X-ray Background Fluctuations'. While it has long been recognized that the X-ray Background (XRB) is primarily of a cosmological origin (with z less than a few), it has recently become apparent that surface brightness fluctuations in the surveys of the XRB can be used to trace the distribution of matter in much the same way as complete catalogs of individual objects. The distance which is probed is related to the angular resolution of the detector; for the HEAO-1 A2 experiment, which provides the best all-sky data base for the XRB in the 2-20 keV band, the effective depth is a few 100 Mpc.

Jahoda, K.↗

BATSE observations of gamma-ray burst spectra. 2: Peak energy evolution in bright, long bursts

We investigate spectral evolution in 37 bright, long gamma-ray bursts observed with the Burst and Transient Source Experiment (BATSE) spectroscopy detectors. High-resolution spectra are chracterized by the energy of the peak of nu F(sub nu), and the evolution of this quantity is examined relative to the emission intensity. In most cases it is found that this peak energy either rises with or slightly precedes major intensity increases and softens for the remainder of the pulse. Interpulse emission is generally harder early in the burst. For bursts with multiple intensity pulses, later spikes tend to be softer than earlier ones, indicating that the energy of the peak of nu F(sub nu) is bounded by an envelope which decays with time. Evidence is found that bursts in which the bulk of the flux comes well after the event which triggers the instrument tend to show less peak energy variability and are not as hard as several bursts in which the emission occurs promptly after the trigger. Several recently proposed burst models are examined in light of these results and no qualitative conflicts with the observations presented here are found.

Ford, L. A.↗

Mesogranulation as A Distinct Scale of Convection in the Sun

We present evidence for the existence of mesogranulation as a scale of convection distinct from granulation and supergranulation through analysis of full-disk Doppler velocity images of the Sun collected by the Michelson Doppler Imager (MDI) aboard the NASA/ESA Solar and Heliospheric Observatory (SOHO). Our analysis procedures isolate nearly steady flows in the solar photosphere and yield power spectra of convection for spherical harmonic degrees up to I = 1000. Each spectrum exhibits an obvious supergranulation peak at I approximately 130 and a broad secondary peak at I approximately 600 with a distinct break in the spectrum between these peaks at I approximately 300. We believe that this secondary peak is a signature of mesogranulation with typical cell diameters of about 7 Mm. Our standard analysis procedure is to first remove the p-mode oscillation signal by averaging individual Dopplergrams over 17-minute intervals. Next, by fitting to standard functional forms we remove Doppler signals due to the motion of the spacecraft, the convective blueshift, solar rotation including differential rotation, and the meridional circulation in order to produce Dopplergrams dominated by convective motions. By mapping these processed images onto heliographic coordinates and projecting onto spherical harmonics, we produce a power spectrum of solar convection for each 17-minute period. We construct synthetic images and pass them through the same analysis procedure in order to determine the actual solar convection spectrum that reproduces the analyzed results. We find that a small but increasing percentage of high-degree convective power is lost in the analysis as we approach the limit of resolution of the detector but'that the broad, mesogranulation peak at I approximately 600 must be included in the convection spectrum of the synthetic images.

Bachmann, Kurt T.↗

ROSAT Science Data Center

This report provides a summary of the Smithsonian Astrophysical Observatory (SAO) ROSAT SCIENCE DATA CENTER (RSDC) activities for the recent years of our contract. Details have already been reported in the monthly reports. The SAO was responsible for the High Resolution Imager (HRI) detector on ROSAT. We also provided and supported the HRI standard analysis software used in the pipeline processing (SASS). Working with our colleagues at the Max Planck in Garching Germany (MPE), we fixed bugs and provided enhancements. The last major effort in this area was the port from VMS/VAX to VMS/ALPHA architecture. In 1998, a timing bug was found in the HRI standard processing system which degraded the positional accuracy because events accessed incorrect aspect solutions. The bug was fixed and we developed off-line correction routines and provided them to the community. The Post Reduction Off-line Software (PROS) package was developed by SAO and runs in the IRAF environment. Although in recent years PROS was not a contractual responsibility of the RSDC, we continued to maintain the system and provided new capabilities such as the ability to deal with simulated AXAF data in preparation for the NASA call for proposals for Chandra. Our most recent activities in this area included the debugging necessary for newer versions of IRAF which broke some of our software. At SAO we have an operating version of PROS and hope to release a patch even though almost all functionality that was lost was subsequently recovered via an IRAF patch (i.e. most of our problems were caused by an IRAF bug).

Murray, Stephen↗

Chandra Observations of the Crab Pulsar as a Function of Pulse Phase

The Chandra X-Ray Observatory was used to observe the Crab Nebula and its pulsar using the LETGS, i.e. the Low-Energy Transmission Grating (LETG) with the High Resolution Camera Spectroscopy detector (HRC-S). Data from the zeroth-order image was utilized to isolate the pulsar from the surrounding nebula and to measure the pulsar emission as a function of pulse phase. HRC timing problems were overcome by developing special techniques to process the data. For the first time, pulsed x-ray emission has been detected at all pulse phases, allowing us to set a new upper limit to the thermal emission from the surface of the neutron star.

Weisskopf, Martin C.↗

Diffraction Effects in a Grating Spectrometer

This paper describes a numerical study of diffraction effects in the AIRES optical system using GLAD by Applied Optics Research. AIRES (or Airborne Infrared Echelle Spectrometer) employs two gratings in series. The small, first-order (i.e., predisperser) grating sorts orders for the large, high-order echelle grating, thus providing moderately high spectral resolution over 3.6 octaves in wavelength. The AIRES' optical design includes three field stops (i.e., a circular aperture and two long, narrow slits) and four pupil stops. A detailed diffraction analysis is required to evaluate critical trade-offs between spectral resolution, optical throughput, detector background, scattered light, and system size and weight. Such an analysis must consider diffraction effects at the pupil stops (edge diffraction), at the field stops (spatial filtering), and at intermediate positions where other optical elements are located. The effects of slit width, slit length, oversizing of the second slit relative to the first, baffling at the Lyot stop and subsequent pupil stops, and the necessity for oversizing other optical elements are presented and discussed. It is found that for narrow slits, the downstream energy distribution is significantly broadened relative to that for large slits, where telescope diffraction dominates, leading to significantly more light loss than anticipated, unless other key optical elements are oversized. The importance of performing a proper diffraction analysis is emphasized and the suitability of GLAD for this task is discussed.

Haas, Michael R.↗