Search NASA⌕ Search

SEARCH · Search NASA

Results for “device stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.↗

A case for Large Space Systems Technology

The NASA Large Space Systems Technology (LSST) program, devoted to the development of Space Shuttle-deployable orbiting structures, is reviewed. The LSST program elements are: antennas, space platforms, assembly equipment and devices, surface sensors and control, control and stabilization, and analysis and design systems. Among the specific prospective applications for this technology base may be counted: multipurpose platforms, materials experimentation facilities, energy satellites, large optical and radio arrays, and communications platforms.

Huckins, E. K., III↗

Shuttle infrared telescope facility pointing and control system

The Shuttle Infrared Telescope Facility (SIRTF) is being designed as a 0.85 m cryogenically cooled telescope capable of a three order of magnitude improvement over currently available infrared instruments. The SIRTF requires that the image at the focal plane be stabilized to better than 0.25 arcsec with an absolute accuracy of 1.0 arcsec. Current pointing-mount performance simulations indicate that neither of these requirements can be met without additional stabilization. The SIRTF pointing and control system will utilize gyro outputs, star field position measurements from a focal plane fine guidance sensor, and a steerable secondary mirror to provide the necessary stabilization and pointing control. The charge coupled device fine guidance sensor tracks multiple stars simultaneously and, through the use of multistar processing algorithms in a high performance microcomputer, generates three-axis attitude errors and gyro-drift estimates to correct the pointing-mount gyros. A high-bandwidth feedforward loop, driven directly from the pointing-mount gyro package, controls the steering mirror in order to correct disturbances not compensated for by the pointing-mount control system. A prototype design for the SIRTF pointing and control system is described in detail. Performance analyses made using a digital simulation of the pointing and control system as well as experimental data obtained in laboratory and field test measurements are presented.

Lorell, K. R.↗

The Development of a PdCr Integral Weldable Strain Measurement System Based on NASA Lewis PdCr/Pt Strain Sensor for User-Friendly Elevated Temperature Strain Measurements

This report describes the development of a user friendly weldable strain gage employing the NASA Lewis PdCr/Pt wire strain sensor. The NASA sensors are pre-attached to Hastelloy X or Titanium alloy shims using name spray techniques developed under previous NASA programs. The weldable sensors are then pre-stabilized for 50 hours at 780 C in air. A weldable terminal and high temperature cable is then connected to the sensor and the assembly is pre-calibrated over the full test temperature range. Calibrated resistors are inserted into a bridge completion module at the cool end of the cable to condition the sensor in half or full bridge configuration. The sensor is attached to the structure using a common capacitive discharge spot welder. No additional high temperature stabilization or calibration is required. The resultant device is a pre-calibrated strain transducer which can be plugged into any common variety strain instrumentation.

Wnuk, S. P., Jr.↗

Contributions of Spherical Harmonics to Magnetic and Gravitational Fields

Gravitational forces are of cardinal importance in the dynamics of spacecraft; magnetic attractions sometime play a significant role also, as was the case with the Long Duration Exposure Facility, and as is now true for the first segment of Space Station Freedom. Both satellites depend on gravitational moment and a device known as a magnetic damper to stabilize their orientation. Magnetic fields are mathematically similar to gravitational fields in one important respect: each can be regarded as a gradient of a potential function that, in turn, can be described as an infinite series of spherical harmonics. Consequently, the two fields can be computed, in part, with quantities that need only be evaluated once, resulting in a savings of time when both fields are needed. The objective of this material is to present magnetic field and gravitational force expressions, and point out the terms that belong to both this is accomplished in Section 1 and 2. Section 3 contains the deductive reasoning with which one obtains the expressions of interest. Finally, examples in Section 4 show these equations can be used to reproduce others that arise in connection with special cases such as the magnetic field produced by a tilted dipole, and gravitational force exerted by an oblate spheroid. The mathematics are discussed in the context of terrestrial fields; however, by substituting appropriate constants, the results can be made applicable to fields belonging to other celestial bodies. The expressions presented here share the characteristics of algorithms set forth for computing gravitational force. In particular, computation is performed speedily by means of recursion formulae, and the expressions do not suffer from the shortcoming of a singularity when evaluated at points that lie on the polar axis.

Roithmayr, Carlos M.↗

Blended-Wing-Body Transonic Aerodynamics: Summary of Ground Tests and Sample Results

The Blended-Wing-Body (BWB) concept has shown substantial performance benefits over conventional aircraft configuration with part of the benefit being derived from the absence of a conventional empennage arrangement. The configuration instead relies upon a bank of trailing edge devices to provide control authority and augment stability. To determine the aerodynamic characteristics of the aircraft, several wind tunnel tests were conducted with a 2% model of Boeing's BWB-450-1L configuration. The tests were conducted in the NASA Langley Research Center's National Transonic Facility and the Arnold Engineering Development Center s 16-Foot Transonic Tunnel. Characteristics of the configuration and the effectiveness of the elevons, drag rudders and winglet rudders were measured at various angles of attack, yaw angles, and Mach numbers (subsonic to transonic speeds). The data from these tests will be used to develop a high fidelity simulation model for flight dynamics analysis and also serve as a reference for CFD comparisons. This paper provides an overview of the wind tunnel tests and examines the effects of Reynolds number, Mach number, pitch-pause versus continuous sweep data acquisition and compares the data from the two wind tunnels.

Carter, Melissa B.↗

Combustion stability with baffles, absorbers and velocity sensitive combustion

Analytical and computational techniques were developed to predict the stability behavior of liquid propellant rocket combustors using damping devices such as acoustic liners, slot absorbers, and injector face baffles. Models were developed to determine the frequency and decay rate of combustor oscillations, the spatial and temporal pressure waveforms, and the stability limits in terms of combustion response model parameters.

Mitchell, C. E.↗

Performance of a Smart Vibration Isolator for Precision Spacecraft Instruments

Under the ARPA SMS Partnership Program for Synthesis and Processing of Smart Materials, Lockheed Missiles and Space company, Inc. has developed a demonstration prototype vibration cancelling mount using electrostrictive ceramic and shape-memory alloy actuators. Shape-memory actuators provide an adaptive-passive, self-damping support for isolation, while the electrostrictive actuators are employed to provide force and position control. The demonstration device was designed to address generic requirements for vibration stabilization of precision spacecraft instruments. It is reconfigurable to operate in any of four modes; passive isolation, active-passive isolation using force cancellation, active precision positioning, and active disturbance rejection. The presentation summarizes design of the device design and results of experimental evaluations of the device in isolation (active and passive) and positioning modes. Rejection of payload-borne disturbances is also discussed with reference to predictions from experimentally calibrated simulations. Finally, avenues for further development and refinement of the device are discussed.

Regelbrugge, Marc E.↗

Development of a perturbation generator for vortex stability studies

Theory predicts vortex instability when subjected to certain types of disturbances. It was desired to build a device which could introduce controlled velocity perturbations into a trailing line vortex in order to study the effects on stability. A perturbation generator was designed and manufactured which can be attached to the centerbody of an airfoil type vortex generator. Details of design tests and manufacturing of the perturbation generator are presented. The device produced controlled perturbation with frequencies in excess of 250 Hz. Preliminary testing and evaluation of the perturbation generator performance was conducted in a 4 inch cylindrical pipe. Observations of vortex shedding frequencies from a centerbody were measured. Further evaluation with the perturbation generator attached to the vortex generator in a 2 x 3 foot wind tunnel were also conducted. Hot-wire anemometry was used to confirm the perturbation generator's ability to introduce controlled frequency fluctuations. Comparison of the energy levels of the disturbances in the vortex core was made between locations 42 chord lengths and 15 chord lengths downstream.

Riester, J. E.↗

Robust stability of diamond families of polynomials with complex coefficients

Like the interval model of Kharitonov, the diamond model proves to be an alternative powerful device for taking into account the variation of parameters in prescribed ranges. The robust stability of some kinds of diamond polynomial families with complex coefficients are discussed. By exploiting the geometric characterizations of their value sets, we show that, for the family of polynomials with complex coefficients and both their real and imaginary parts lying in a diamond, the stability of eight specially selected extreme point polynomials is necessary as well as sufficient for the stability of the whole family. For the so-called simplex family of polynomials, four extreme point and four exposed edge polynomials of this family need to be checked for the stability of the entire family. The relations between the stability of various diamonds are also discussed.

Xu, Zhong Ling↗

Developing An Earth-Fixed Visual Reference to Aid Stability, Readaptation and Egress After a Water Landing

INTRODUCTION Water landings present the worst possible sensory conditions for crews trying to orient and stabilize themselves immediately after long-duration spaceflight. Of the three sensory feedback systems involved in maintaining stability (i.e., proprioceptive, vestibular, and visual), none will provide reliable orientation information under the current water landing scenarios. The proprioceptive and vestibular systems are affected during spaceflight by disuse and adaptation to microgravity. Vision may not suffer the same degradation, but the visual environment within the enclosed space of a capsule, or interior room of a recovery ship, is disorienting when subject to wave-induced motion. The result is an increased risk of fall-related injury. In a prior study, 70% (21 of 30) of nonimpaired subjects reported that the presence of an Earth-fixed horizontal line helped them stabilize when their visually enclosed environment was exposed to wave motion. In addition to aiding stability, sensory re-adaptation occurs when inputs from the three sensory systems are synchronized with one another and aligned with Earth’s gravity. The earlier an Earth-fixed visual reference can be introduced the sooner the readaptation process can begin. The goal of this project is to identify the optimal features of a device that visually presents gravitational reference cues to support stability and readaptation. METHODS The capsule sensory-condition simulator is a three-sided enclosure atop a six degree-of-freedom motion platform. A sum-of-sines equation is used to drive the motion platform, producing the simulated wave motion. The equation was derived using the frequency range present in inertial measurement unit (IMU) data collected during open-water Orion mock-up testing. The enclosure creates the nature of a floating visual environment where the walls move in relation to the standing surface. To more accurately represent the condition of postflight crewmembers, galvanic vestibular stimulation (GVS) is applied to disrupt normal vestibular function and standing on a compliant surface attenuates proprioceptive feedback. An instrumented handhold allows the subjects to stabilize themselves and serves as the primary dependent variable. Subjects are instructed to minimize handhold use so the higher forces applied to the handhold correspond to greater instability. Various forms of a visual reference have been explored. Passive systems, such as mechanical gimbals and weighted plumb bobs were eliminated from consideration because of the intertia-induced oscillations that the wave-motion causes. Laser lines presented as horizontal, vertical, or the combination of both are being used to provide the Earth-fixed visual reference. These are presented in the central visual field or periphery from laser sources that are mounted either from within or outside the visual enclosure. RESULTS Data collection for this study is currently in progress. CONCLUSIONS This study will determine whether a visual reference system can help improve stability during challenging sensory conditions and define the optimal chacteristics for such a system.

Brian T Peters↗

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph↗

Large space systems technology program

Technical challenges of shuttle-era large space systems include the development of space-configured spacecraft concepts, compatibility with the space transportation system, and cost effectiveness. The objectives and organization of NASA's large space structures program are outlined and program elements are discussed. The technology for the offset wrap-rip and the maypole (hoop/column) antenna concepts are discussed as well as analysis techniques for predicting the electromagnetic performance of a broad class of large reflectors. Deployable systems, assembly methods, and modular control systems for space platforms are described. Assembly equipment and devices, surface sensors and shape control, control and stabilization, and integrated analysis and design are also considered.

James, R. L., Jr.↗

Diffusion barriers

The choice of the metallic film for the contact to a semiconductor device is discussed. One way to try to stabilize a contact is by interposing a thin film of a material that has low diffusivity for the atoms in question. This thin film application is known as a diffusion barrier. Three types of barriers can be distinguished. The stuffed barrier derives its low atomic diffusivity to impurities that concentrate along the extended defects of a polycrystalline layer. Sacrificial barriers exploit the fact that some (elemental) thin films react in a laterally uniform and reproducible fashion. Sacrificial barriers have the advantage that the point of their failure is predictable. Passive barriers are those most closely approximating an ideal barrier. The most-studied case is that of sputtered TiN films. Stuffed barriers may be viewed as passive barriers whose low diffusivity material extends along the defects of the polycrystalline host.

Nicolet, M. A.↗

Transonic aerodynamic characteristics of a proposed Assured Crew Return Capability (ACRC) lifting-body configuration

The investigation was conducted in the Calspan 8-Ft Transonic wind tunnel at Mach numbers from 0.6 to 1.2. The 0.07-scale model had a low aspect ratio body with a flat undersurface. A center fin and two tip fins were mounted on the aft upper body. The tip fins were rolled outboard 40 deg from the vertical. Elevon surfaces made up the trailing edges of the outboard fins and body flaps were located on the upper and lower aft fuselage. Results of the investigation indicated that the model was longitudinally and laterally stable about a center-of-gravity position of 0.54 body length. The maximum trimmed lift-drag ratio was about 3.1 at M = 0.6. The small center fin contributed only a small positive increment to lateral stability but was effective as a yaw control device. Protuberances on the forebody had little effect on the aerodynamic characteristics of the configuration. The model with pitch controls undeflected had desirable longitudinal trim characteristics.

Ware, George M.↗

Solid-state lasers for coherent communication and remote sensing

Work in the stabilization of monolithic Nd:YAG lasers and the application of these lasers to nonlinear optical frequency conversion is discussed. The intrinsic stability of semiconductor diode laser pumped solid state lasers has facilitated a number of demonstration in external resonant cavity harmonic generation and stable optical parametric oscillation. Relative laser frequency stabilization of 0.3 Hz was achieved, and absolute stability of a few hundred hertz is anticipated. The challenge is now to reproduce this frequency stability in the output of tunable nonlinear optical devices. Theoretical and experimental work toward this goal are continuing.

Byer, Robert L.↗

Application and use of spinal immobilization devices in zero-gravity flight

A KC-135 parabolic flight was performed for the purpose of evaluation of spinal immobilization techniques in microgravity. The flight followed the standard 40 parabola profile with four NASA/KRUG experimenters involved. One performed as coordinator/recorder, one as test subject, and two as the Crew Medical Officers (CMO). The flight was to evaluate the application of spinal immobilization devices and techniques in microgravity as are performed during initial stabilization or patient transport scenarios. The sequence of detail for examination of the following objectives included: attempted cervical spine immobilization with all free floating, the patient restrained to the floor, various hand positioning techniques; c-collar placement; Kendrick Extrication Device (KED) application with various restraints for patient and CMO; patient immobilization and transport using the KED; patient transported on KED and spine board. Observations for each task are included. Major conclusions and issues are also included.

Krupa, Debra T.↗