Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Mechanical Behavior of UO 2 at Sub-grain Length Scales: Quantification of Elastic, Plastic and Creep Properties via Microscale Testing

Techniques were developed to measure properties at sub-grain scales using depleted Uranium Oxide (d-UO2) samples heat-treated to obtain different grain sizes and oxygen stoichiometries, through three main tasks: 1) sample processing and characterization, 2) microscale and conventional testing and 3) modeling. Grain size and crystallography were characterized using Scanning Electron Microscopy (SEM), in conjunction with Electron Backscattering Diffraction (EBSD) and Electron Channeling Contrast Imaging (ECCI). Grains were then carefully selected based on their crystallographic orientations to perform ex-situ micromechanical tests with samples machined via Focused Ion Beam (FIB), with emphasis on micro-cantilever bending. These experiments were performed under controlled atmospheres, to insure stoichiometry control, at temperatures up to 700 °C and allowed measurements involving elastic (effective Young’s modulus), plastic (critical resolved shear stresses) and creep (creep strain rates) behavior. Conventional compression experiments were performed simultaneously to compare with the ex-situ measurements and study potential size effects. Modeling was implemented using anisotropic elasticity and inelastic constitutive relations for plasticity and creep based on kinematics and kinetics of dislocation glide that account for the effects of crystal orientation, and stress. The models will be calibrated and validated using the experimental data. This project provided insight on correlations among stoichiometry, crystallography and mechanical behavior in advanced oxide fuels, provided valuable experimental data to validate and calibrate mesoscale fuel performance codes and also a framework to measure sub-grain scale mechanical properties that should be suitable for use with irradiated samples due to small volumes required. The goals and metrics of the ongoing study of thermo-mechanical behavior in depleted uranium dioxide (d-UO 2 ) outlined in this project have been concluded successfully, resulting in: 1) the successful fabrication, processing, and characterization of large-grained samples with various orientations (up to and including single crystals) having stoichiometric and hyper-stoichiometric O/U ratios; 2) formulation, calibration, and validation of a crystal plasticity constitutive model to describe the creep deformation of UO 2 at the sub-grain length scale (single crystal level) at intermediate temperatures; 3) the successful calibration of a crystal plasticity constitutive model to describe the elasto-plastic deformation of microcantilever beams, also at moderate temperatures. Samples were prepared from natural uranium oxide powder of production-quality provided by Areva. The powder was pressed in a die to a pressure of 100 MPa to produce green pellets with no sintering aids, lubricants, or any other additives. The green pellets were then heated up to 1700 °C under ultra-high purity argon atmosphere (~1 ppm O2). The atmosphere was then changed to 79% Argon, 21% O 2 and the temperature was held at 1700 °C for 2 hours to sinter the pellets under oxidative conditions [1] that are known to increase grain growth kinetics in UO 2 [2]. Samples were then cooled down under Ar-4%H2 atmosphere to reduce the samples back to stoichiometric UO 2 . For macro-scale procedures, testing of UO 2 samples with large grains was performed at 1200 °C using a modified load frame capable of applying dead-weight loads to ensure constant stress conditions, while displacement of the sample produced by the applied load was measured with high precision micrometers to obtain strains. Stress steps were used during testing and the strains were monitored to measured creep strain rates under steady state for each level of stress used, so that stress exponents could be obtained. The results of the mechanical testing, along with sample geometry and crystal orientation of the grains in the samples, as well as post-test sample characterization were used to formulate a viscoplastic model to account for steady state (stage II) creep behavior, along with basic assumptions from crystal plasticity and kinematic constraints due to testing fixtures. In the micro-scale, testing of microcantilever beams at temperatures ranging from 25 to 570 °C was performed in-situ with a scanning electron microscope with a special attachment to apply load and measure displacement while the samples were at temperature. The load-displacement curves obtained showed linear behavior before fracture for all temperatures attempted except 570 °C, where clear deviations from non-linearity were observed before fracture. These deviations were consistently observed for all samples tested for a given orientation. A viscoplastic model was used to account for the presence of inelastic strain, along with basic assumptions from crystal plasticity and beam theory. These models were kept as simple as possible, and results from tests performed in a set of samples with a given crystal orientation were used to calibrate the material constants for the model, while results from a different sample set were then used for validation, thus satisfying the conditions of all main tasks within the parameters of this project. Details of these efforts are outlined in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transform approach to electromagnetic scattering

In this paper, a comprehensive review of the Fourier transform technique as applied to the problem of high-frequency scattering is presented and the concepts of the spectral theory of diffraction (STD) are introduced. In contrast to the more commonly employed ray-optical method for high-frequency scattering, the STD approach interprets the scattered field as the spectrum, or the Fourier transform of the induced current on the scatterer. Such an interpretation offers several important advantages: uniform nature of representation, capacity to improve and extend the ray-optical formulas in a systematic manner, and convenient accuracy tests for the results. Methods for combining integral equation methods with the Galerkin procedure and asymptotic techniques in the transform domain are described, and representative examples illustrating the application of the spectral approach are included.

Mittra, R.↗

Advancing neutron diffraction for accurate structural measurement of light elements at megabar pressures

Over the last 60 years, the diamond anvil cell (DAC) has emerged as the tool of choice in high pressure science because materials can be studied at megabar pressures using X-ray and spectroscopic probes. In contrast, the pressure range for neutron diffraction has been limited due to low neutron flux even at the strongest sources and the resulting large sample sizes. Here, we introduce a neutron DAC that enables break-out of the previously limited pressure range. Key elements are ball-bearing guides for improved mechanical stability, gem-quality synthetic diamonds with novel anvil support and improved in-seat collimation. We demonstrate a pressure record of 1.15 Mbar and crystallographic analysis at 1 Mbar on the example of nickel. Additionally, insights into the phase behavior of graphite to 0.5 Mbar are described. These technical and analytical developments will further allow structural studies on low-Z materials that are difficult to characterize by X-rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practical aspects of diffractive imaging using an atomic-scale coherent electron probe

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a technique where a full two-dimensional convergent beam electron diffraction (CBED) pattern is acquired at every STEM pixel scanned. Capturing the full diffraction pattern provides a rich dataset that potentially contains more information about the specimen than is contained in conventional imaging modes using conventional integrating detectors. In this work, using 4D datasets in STEM from two specimens, monolayer MoS 2 and bulk SrTiO 3 , we demonstrate multiple STEM imaging modes on a quantitative absolute intensity scale, including phase reconstruction of the transmission function via differential phase contrast imaging. Finally, practical issues about sampling (i.e. number of detector pixels), signal-to-noise enhancement and data reduction of large 4D-STEM datasets are emphasized.

36 MATERIALS SCIENCE↗

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

Dynamical diffraction imaging (topography) with X-ray synchrotron radiation

By contrast to electron microscopy, which yields information on the location of features in small regions of materials, X-ray diffraction imaging can portray minute deviations from perfect crystalline order over larger areas. Synchrotron radiation-based X-ray optics technology uses a highly parallel incident beam to eliminate ambiguities in the interpretation of image details; scattering phenomena previously unobserved are now readily detected. Synchrotron diffraction imaging renders high-resolution, real-time, in situ observations of materials under pertinent environmental conditions possible.

Kuriyama, M.↗

Use of synchrotron based diffraction enhanced imaging for visualization of soft tissues in invertebrates

Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

43 PARTICLE ACCELERATORS↗

Superresolved multiphoton microscopy with spatial frequency-modulated imaging

Superresolved far-field microscopy has emerged as a powerful tool for investigating the structure of objects with resolution well below the diffraction limit of light. Nearly all superresolution imaging techniques reported to date rely on real energy states of fluorescent molecules to circumvent the diffraction limit, preventing superresolved imaging with contrast mechanisms that occur via virtual energy states, including harmonic generation (HG). Here, we report a superresolution technique based on spatial frequency-modulated imaging (SPIFI) that permits superresolved nonlinear microscopy with any contrast mechanism and with single-pixel detection. We show multimodal superresolved images with two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG) from biological and inorganic media. Multiphoton SPIFI (MP-SPIFI) provides spatial resolution up to 2η below the diffraction limit, where η is the highest power of the nonlinear intensity response. MP-SPIFI can be used to provide enhanced resolution in optically thin media and may provide a solution for superresolved imaging deep in scattering media.

36 MATERIALS SCIENCE↗

Radiologist Evaluation of an X-ray Tube Based Diffraction Enhanced Imaging Prototype Using Full Thickness Breast Specimens.

Conventional mammographic image contrast is derived from x-ray absorption, resulting in breast structure visualization due to density gradients that attenuate radiation without distinction between transmitted, scattered, or refracted x-rays. Diffraction-enhanced imaging (DEI) allows for increased contrast with decreased radiation dose compared to conventional mammographic imaging because of monochromatic x-rays, its unique refraction-based contrast mechanism, and excellent scatter rejection. However, a lingering drawback to the clinical translation of DEI has been the requirement for synchrotron radiation. The authors laboratory developed a DEI prototype (DEI-PR) using a readily available tungsten x-ray tube source and traditional DEI crystal optics, providing soft tissue images at 60 keV. Images of full-thickness human breast tissue specimens were acquired on synchrotron-based DEI (DEI-SR), DEI-PR, and digital mammographic systems. A panel of expert radiologists evaluated lesion feature visibility and correlation with pathology after receiving training on the interpretation of refraction contrast mammographic images. For mammographic features (mass, calcification), no significant differences were detected between the DEI-SR and DEI-PR systems. Benign lesions were perceived as better seen by radiologists using the DEI-SR system than the DEI-PR system at the [111] reflectivity, with generalizations limited by small sample size. No significant differences between DEI-SR and DEI-PR were detected for any other lesion type (atypical, cancer) at either crystal reflectivity. Thus, except for benign lesion characterizations, the DEI-PR system's performance was roughly equivalent to that of the traditional DEI system, demonstrating a significant step toward clinical translation of this modality for breast cancer applications.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging nanoscale lattice variations by machine learning of x-ray diffraction microscopy data

In this paper, we present a novel methodology based on machine learning to extract lattice variations in crystalline materials, at the nanoscale, from an x-ray Bragg diffraction-based imaging technique. By employing a full-field microscopy setup, we capture real space images of materials, with imaging contrast determined solely by the x-ray diffracted signal. The data sets that emanate from this imaging technique are a hybrid of real space information (image spatial support) and reciprocal lattice space information (image contrast), and are intrinsically multidimensional (5D). By a judicious application of established unsupervised machine learning techniques and multivariate analysis to this multidimensional data cube, we show how to extract features that can be ascribed physical interpretations in terms of common structural distortions, such as lattice tilts and dislocation arrays. Finally, we demonstrate this 'big data' approach to x-ray diffraction microscopy by identifying structural defects present in an epitaxial ferroelectric thin-film of lead zirconate titanate.

36 MATERIALS SCIENCE↗

Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals

An analyzer-based x-ray phase-contrast microscopy (ABM) setup combining a standard analyzer-based x-ray phase-contrast imaging (ABI) setup [nondispersive 4-crystal setup (Bonse-Hart setup)] and diffraction by asymmetrically cut crystals is presented here. An attenuation-contrast microscopy setup with conventional x-ray source and asymmetrically cut crystals is first analyzed. Edge-enhanced effects attributed to phase jumps or refraction/total external reflection on the fiber borders were detected. However, the long exposure times and the possibility to achieve high contrast microscopies by using extremely low attenuation-contrast samples motivated us to assemble the ABM setup using a synchrotron source. This setup was found to be useful for low contrast attenuation samples due to the low exposure time, high contrast, and spatial resolution found. Moreover, thanks to the combination with the nondispersive ABI setup, the diffraction-enhanced x-ray imaging algorithm could be applied.

36 MATERIALS SCIENCE↗

Liquid Structure of Shock-Compressed Hydrocarbons at Megabar Pressures

We present here results for the ionic structure in hydrocarbons (polystyrene, polyethylene) that were shock compressed to pressures of up to 190 GPa, inducing rapid melting of the samples. The structure of the resulting liquid is then probed using in situ diffraction by an x-ray free electron laser beam, demonstrating the capability to obtain reliable diffraction data in a single shot, even for low-Z samples without long range order. The data agree well with ab initio simulations, validating the ability of such approaches to model mixed samples in states where complex interparticle bonds remain, and showing that simpler models are not necessarily valid. While the results clearly exclude the possibility of complete carbon-hydrogen demixing at the conditions probed, they also, in contrast to previous predictions, indicate that diffraction is not always a sufficient diagnostic for this phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of volume-weighted average grain size in Fe-based nanocrystalline soft magnetic materials by autocorrelation function

Highlights: • Normalized ACF of TEM images estimates the volume-weighted average grain size. • Grain size estimation by normalized ACF shows good accuracy and time efficiency. • Normalized ACF can reveal grain size difference in different areas of a TEM sample. • Normalized ACF helps modelling of grain size distributions in Fe-B nanostructures. - Abstract: The coercivity of Fe-based nanocrystalline soft magnetic materials depends critically on the grain size of bcc-Fe grains. Accurately estimating the volume-weighted mean grain size is extremely important to develop new Fe-based nanocrystalline soft magnetic materials with low coercivity. This article shows that autocorrelation analysis of dark-field transmission electron microscope (TEM) images provides a very good estimation of bcc-Fe grain size in nanocrystalline soft magnetic materials. This method can be used to efficiently estimate the volume-weighted average grain size from multiple TEM images with much less inherent bias than manual measurement techniques. The estimated grain sizes show good consistency to the grain sizes estimated by X-ray diffraction (XRD) and manual measurement. In contrast to XRD, this method can also reveal the differences in grain size from different micron-sized regions of a sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of crystallographic orientation and applied magnetic field on domain structure in duplex stainless steel studied using magnetic force microscopy

Highlights: • Ferrite phase in a duplex stainless steel consists of stripe type domains. • Domain contrast decreases with deviation of plane normal from <100>. • Domain width increases with deviation of plane normal from <100>. • Domain alignment with applied field observed along <100> directions. • Grain boundary stray field is a function of misorientation between grains. - Abstract: The paper investigates the local micro-magnetization behavior in duplex stainless steel (DSS) using magnetic force microscopy (MFM). DSS has equal amount of austenite phase in ferrite matrix. The MFM imaging clearly differentiates ferrite phase (ferromagnetic) from the austenite phase (paramagnetic) due to the maze type magnetic domains present in the ferrite phase. The magneto crystalline anisotropic effect on the domain structure is discussed with the support of electron backscatter diffraction (EBSD) measurements. The MFM phase contrast and domain width are correlated with the orientation of surface normal with respect to the easy axis of magnetization (<100>). The influence of external magnetic field (±127 kA/m) application on the domain structure is studied as a function of the grain orientation and the leakage field at the grain boundaries is analyzed based on the mis-orientation between the grains.

36 MATERIALS SCIENCE↗

Epitaxial V{sub 0.6}W{sub 0.4}N/MgO(001): Evidence for ordering on the cation sublattice

V{sub 0.6}W{sub 0.4}N alloys are grown on MgO(001) by ultrahigh vacuum reactive magnetron sputtering from V and W targets in 10 mTorr pure-N{sub 2} atmospheres at temperatures T{sub s} ranging from 600 to 900 Degree-Sign C. Based on x-ray diffraction and transmission electron microscopy results, all films have the B1-NaCl crystal structure and grow with a cube-on-cube epitaxial relationship to the substrate, (001){sub VWN} Double-Vertical-Line (001){sub MgO} and [100]{sub VWN} Double-Vertical-Line [100]{sub MgO}. Rutherford backscattering spectrometry analyses show that the N content in V{sub 0.6}W{sub 0.4}N{sub x} alloys decreases with increasing T{sub s} from overstoichiometric with x = 1.13 at 600 Degree-Sign C, to approximately stoichiometric with x = 1.08 at 700 Degree-Sign C, to understoichiometric at 800 Degree-Sign C (x = 0.80) and 900 Degree-Sign C (x = 0.75). High-resolution scanning transmission electron microscopy, Z-contrast, and selected-area electron diffraction investigations of V{sub 0.6}W{sub 0.4}N(001) alloys grown at 600 and 700 Degree-Sign C reveal the onset of W ordering on adjacent 111 planes of the metal sublattice; no ordering is observed for understoichiometric films grown at higher temperatures.

36 MATERIALS SCIENCE↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

Rapid misfit dislocation characterization in heteroepitaxial III-V/Si thin films by electron channeling contrast imaging

Electron channeling contrast imaging (ECCI) is used to characterize misfit dislocations in heteroepitaxial layers of GaP grown on Si(100) substrates. Electron channeling patterns serve as a guide to tilt and rotate sample orientation so that imaging can occur under specific diffraction conditions. This leads to the selective contrast of misfit dislocations depending on imaging conditions, confirmed by dynamical simulations, similar to using standard invisibility criteria in transmission electron microscopy (TEM). The onset and evolution of misfit dislocations in GaP films with varying thicknesses (30 to 250 nm) are studied. This application simultaneously reveals interesting information about misfit dislocations in GaP/Si layers and demonstrates a specific measurement for which ECCI is preferable versus traditional plan-view TEM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗