At least 199 records · Page 11

Angular alignment and fidelity of neutron phase-gratings for improved interferometer fringe visibility

The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3% obtained using this moiré interferometer was well below the theoretical prediction of 30% using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time microstructure of shocked LiF crystals: Use of synchrotron x-rays

We describe the use of a third generation synchrotron facility to obtain in situ, real-time, x-ray diffraction measurements in plate impact experiments. Subnanosecond duration x-ray pulses were utilized to record diffraction data from pure and magnesium-doped LiF single crystals shocked along the [111] and [100] orientations. The peak stresses were 3.0 GPa for the [111] oriented LiF and between 3.0 and 5.0 GPa for the [100] oriented LiF. For these stresses, shock compression along [111] results in elastic deformation and shock compression along [100] results in elastic-plastic deformation. Because of the quality of the synchrotron x-ray pulses, both shifting and broadening of the diffraction data were obtained simultaneously. As expected, shifts for elastic compression and elastic-plastic compression in shocked LiF were consistent with uniaxial and isotropic lattice compression, respectively. More importantly, diffraction patterns from crystals shocked along [100] exhibited substantial broadening due to elastic-plastic deformation. The broadening indicates that the shocked LiF(100) crystals developed substructure with a characteristic size for coherently diffracting domains (0.1-10{micro}m) and a distribution of (100) microlattice-plane rotations ({approx} 1{sup o} wide). In contrast to the LiF(100) results, broadening of the diffraction pattern did not occur for elastically deformed LiF(111). Another important finding was that the amount of lattice disorder for shocked LiF(100) depends on the loading history; the broadening was larger for the magnesium-doped LiF(100) (large elastic precursor) than for ultrapure LiF(100) (small elastic precursor) shocked to the same peak stress. The data are simulated by calculating the diffraction pattern from LiF(100) with a model microstructure consisting of coherently diffracting domains. The lattice orientation and longitudinal strain is assumed uniform within domains, but they vary from domain to domain with Gaussian distributions. Simulations using such a model are in good agreement with the measured diffraction patterns. The principal finding from the present work is that synchrotron x-rays can provide real-time data regarding microstructure changes accompanying shock-induced deformation and structural changes.

43 PARTICLE ACCELERATORS↗

TECHNIQUES FOR HIGH-CONTRAST IMAGING IN MULTI-STAR SYSTEMS. I. SUPER-NYQUIST WAVEFRONT CONTROL

Direct imaging of extra-solar planets is now a reality with the deployment and commissioning of the first generation of specialized ground-based instruments (GPI, SPHERE, P1640, and SCExAO). These systems allow of planets 10{sup 7} times fainter than their host star. For space-based missions (EXCEDE, EXO-C, EXO-S, WFIRST), various teams have demonstrated laboratory contrasts reaching 10{sup −10} within a few diffraction limits from the star. However, all of these current and future systems are designed to detect faint planets around a single host star, while most non-M-dwarf stars such as Alpha Centauri belong to multi-star systems. Direct imaging around binaries/multiple systems at a level of contrast allowing detection of Earth-like planets is challenging because the region of interest is contaminated by the host star's companion in addition to the host itself. Generally, the light leakage is caused by both diffraction and aberrations in the system. Moreover, the region of interest usually falls outside the correcting zone of the deformable mirror (DM) with respect to the companion. Until now, it has been thought that removing the light of a companion star is too challenging, leading to the exclusion of many binary systems from target lists of direct imaging coronographic missions. In this paper, we will show new techniques for high-contrast imaging of planets around multi-star systems and detail the Super-Nyquist Wavefront Control (SNWC) method, which allows wavefront errors to be controlled beyond the nominal control region of the DM. Our simulations have demonstrated that, with SNWC, raw contrasts of at least 5 × 10{sup −9} in a 10% bandwidth are possible.

79 ASTRONOMY AND ASTROPHYSICS↗

An electrically driven terahertz metamaterial diffractive modulator with more than 20 dB of dynamic range

We design and experimentally demonstrate a switchable diffraction grating for terahertz modulation based on planar active metamaterials, where a Schottky gate structure is implemented to tune the metamaterial resonances in real-time via the application of an external voltage bias. The diffraction grating is formed by grouping the active split-ring resonators into an array of independent columns with alternate columns biased. We observe off-axis diffraction over a wide frequency band in contrast to the narrow-band resonances, which permits operation of the device as a relatively high-speed, wide-bandwidth, high-contrast modulator, with more than 20 dB of dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of thermomechanical processing on the microstructure and retained austenite stability during in situ tensile testing using synchrotron x-ray diffraction of NbMoAI TRIP steel.

In this work we compare and contrast the stability of retained austenite during tensile testing of Nb-Mo-Al transformation-induced plasticity steel subjected to different thermomechanical processing schedules. The obtained microstructures were characterised using optical metallography, transmission electron microscopy and X-ray diffraction. The transformation of retained austenite to martensite under tensile loading was observed by in-situ high energy X-ray diffraction at 1ID / APS. It has been shown that the variations in the microstructure of the steel, such as volume fractions of present phases, their morphology and dimensions, play a critical role in the strain-induced transition of retained austenite to martensite.

36 MATERIALS SCIENCE↗

Diffraction-Enhanced Imaging of Musculoskeletal Tissues Using a Conventional X-Ray Tube

DEI based on a conventional x-ray tube allows the visualization of skeletal and soft tissues simultaneously. Although more in-depth testing and optimization of the DEI setup must be carried out, these data demonstrate a proof of principle for further development of the technology for future clinical imaging. In conventional projection radiography, cartilage and other soft tissues do not produce enough radiographic contrast to be distinguishable from each other. Diffraction-enhanced imaging (DEI) uses a monochromatic x-ray beam and a silicon crystal analyzer to produce images in which attenuation contrast is greatly enhanced and x-ray refraction at tissue boundaries can be detected. The aim of this study was to test the efficacy of conventional x-ray tube-based DEI for the detection of soft tissues in experimental samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic grazing incidence fast atom diffraction during molecular beam epitaxial growth of GaAs

A Grazing Incidence Fast Atom Diffraction (GIFAD) system has been mounted on a commercial molecular beam epitaxy chamber and used to monitor GaAs growth in real-time. In contrast to the conventionally used Reflection High Energy Electron Diffraction, all the GIFAD diffraction orders oscillate in phase, with the change in intensity related to diffuse scattering at step edges. We show that the scattered intensity integrated over the Laue circle is a robust method to monitor the periodic change in surface roughness during layer-by-layer growth, with oscillation phase and amplitude independent of incidence angle and crystal orientation. When there is a change in surface reconstruction at the start of growth, GIFAD intensity oscillations show that there is a corresponding delay in the onset of layer-by-layer growth. In addition, changes in the relative intensity of different diffraction orders have been observed during growth showing that GIFAD has the potential to provide insight into the preferential adatom attachment sites on the surface reconstruction during growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Purification, Crystallization and Preliminary X-ray Diffraction Analysis of the Whirly Domain of StWhy2 in Complex with Single-Stranded DNA

StWhy1 and StWhy2 are members of the Whirly family of single-stranded DNA (ssDNA) binding proteins. To understand the mode of binding of the Whirly proteins to single-stranded DNA, crystals of the Whirly domains of both StWhy1 and StWhy2 in complex with single-stranded DNA were obtained by the hanging-drop vapour-diffusion method. The diffraction patterns of the StWhy1-ssDNA complex crystals displayed severe anisotropy and were of low resolution, making them unsuitable for structure determination. In contrast, the crystals of the StWhy2-ssDNA complex diffracted isotropically to 2.20 A resolution. The crystallization and data collection to 2.20 A resolution of StWhy2 in the free form are also reported.

59 BASIC BIOLOGICAL SCIENCES↗

The structure of CO{sub 2} hydrate between 0.7 and 1.0 GPa

A deuterated sample of CO{sub 2} structure I (sI) clathrate hydrate (CO{sub 2}·8.3 D{sub 2}O) has been formed and neutron diffraction experiments up to 1.0 GPa at 240 K were performed. The sI CO{sub 2} hydrate transformed at 0.7 GPa into the high pressure phase that had been observed previously by Hirai et al. [J. Phys. Chem. 133, 124511 (2010)] and Bollengier et al. [Geochim. Cosmochim. Acta 119, 322 (2013)], but which had not been structurally identified. The current neutron diffraction data were successfully fitted to a filled ice structure with CO{sub 2} molecules filling the water channels. This CO{sub 2}+water system has also been investigated using classical molecular dynamics and density functional ab initio methods to provide additional characterization of the high pressure structure. Both models indicate the water network adapts a MH-III “like” filled ice structure with considerable disorder of the orientations of the CO{sub 2} molecule. Furthermore, the disorder appears to be a direct result of the level of proton disorder in the water network. In contrast to the conclusions of Bollengier et al., our neutron diffraction data show that the filled ice phase can be recovered to ambient pressure (0.1 MPa) at 96 K, and recrystallization to sI hydrate occurs upon subsequent heating to 150 K, possibly by first forming low density amorphous ice. Unlike other clathrate hydrate systems, which transform from the sI or sII structure to the hexagonal structure (sH) then to the filled ice structure, CO{sub 2} hydrate transforms directly from the sI form to the filled ice structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of hepatic fibrosis in rats with x-ray diffraction enhanced imaging

X-ray diffraction enhanced imaging (DEI) is a phase contrast technique that generates excellent contrast of biological soft tissues compared to conventional absorption radiography. We explore the application of DEI in the diagnosis of hepatic fibrosis. The produced refraction contrast images of fibrous rat liver samples show clearly abnormal liver architectures. Moreover, by comparing to histological pictures, different stages of fibrosis are discriminated, and the corresponding morphological features are analyzed. Besides, quantitative analyses of texture features are presented. The results reported herein show that DEI can be a potential noninvasive technique to diagnose and stage hepatic fibrosis.

60 APPLIED LIFE SCIENCES↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Local structure of Cu in Cs{sub 8}Na{sub 16}Cu{sub 5}Ge{sub 131} type II clathrate

We have used X-ray absorption spectroscopy (XAS) to investigate the local structure of Cu and Ge in the Cs{sub 8}Na{sub 16}Cu{sub 5}Ge{sub 131} type II clathrate. We show that the local structure parameters for Ge (coordination number and distances) are consistent with those derived on the basis of XRD investigation of Cs{sub 8}Na{sub 16}Ge{sub 136}. The EXAFS data suggest that Cu either randomly substitutes for Ge on the clathrate framework or preferentially on the 96g site but not preferentially on the 32e or 8a sites (Wyckoff notation). Furthermore, we find that the Cu-Ge distance is smaller than the Ge-Ge distance by 0.13 A, indicating a local distortion around the Cu atoms. The estimated degrees of disorder for Cu-Ge and Ge-Ge interactions indicate the Cu-Ge clathrate framework to be relatively stiff, while those for Na-Ge and Cs-Ge interactions corroborate previous observations of strong thermal disorder of the alkali guests in these materials. Our XAS results offer insight into the site substitution of Cu in this material, information unattainable from X-ray diffraction due to the lack of scattering contrast between Cu and Ge. - Graphical abstract: Comparison of Fourier transforms of Cu K-edge and Ge K-edge EXAFS spectra for Cs{sub 8}Na{sub 16}Cu{sub 5}Ge{sub 131} collected near the temperature of liquid nitrogen (LN). The data clearly show that the Cu-Ge distance is smaller than the Ge-Ge distance, indicating the presence of a local distortion around Cu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Investigation of electron-hole recombination-activated partial dislocations and their behavior in 4H-SiC epitaxial layers.

Electron-hole recombination-activated partial dislocations in 4H silicon carbide homoepitaxial layers and their behavior have been studied using synchrotron X-ray topography and electroluminescence. Stacking faults whose expansion was activated by electron-hole recombination enhanced dislocation glide were observed to be bounded by partial dislocations, which appear as white stripes or narrow dark lines in back-reflection X-ray topographs recorded using the basal plane reflections. Such contrast variations are attributable to the defocusing/focusing of the diffracted X-rays due to the edge component of the partial dislocations, which creates a convex/concave distortion of the basal planes. Simulation results based on the ray-tracing principle confirm our argument. Observations also indicate that, when an advancing partial dislocation interacts with a threading screw dislocation, a partial dislocation dipole is dragged behind in its wake. This partial dislocation dipole is able to advance regardless of the immobility of the C-core segment. A kink pushing mechanism is introduced to interpret the advancement of this partial dislocation dipole.

43 PARTICLE ACCELERATORS↗

Interference pattern generation in evanescent electromagnetic waves for nanoscale lithography using waveguide diffraction gratings

The generation of interference patterns of evanescent electromagnetic waves with an essentially subwavelength period using dielectric waveguide diffraction gratings is considered. Using simulations within the framework of the electromagnetic theory, the possibility of obtaining high-quality interference patterns due to enhancement of evanescent diffraction orders under resonance conditions is demonstrated. The contrast of the interference patterns in the case of TE polarisation of the incident wave is close to unity. The field intensity in the near-field interference maxima exceeds the intensity of the incident wave by 25-100 times. The possibility of generation of the interference patterns of evanescent waves corresponding to higher diffraction orders is shown. The use of higher orders reduces the requirements to the fabrication technology and allows generation of interference patterns with a high spatial frequency, using diffraction gratings with a low spatial frequency. Examples of generating interference patters with periods six times smaller than those of the used diffraction gratings are presented. (nanolithography)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Manufacturing and characterization of Ni-free N-containing ODS austenitic alloys

Ni-free N-containing oxide dispersion strengthened (ODS) austenitic alloys were manufactured by mechanical alloying (MA) followed by spark plasma sintering (SPS). The phase evolutions during milling under a nitrogen atmosphere and after sintering were studied by X-ray diffraction (XRD). Transmission electron microcopy (TEM) and contrast variation analysis (ACV), including small-angle neutron scattering (SANS) and ultra-small X-ray scattering (USAXS), revealed the existence of nanoparticles with a diameter of 3-51 nm for the samples sintered at 950 ºC. Sintering at 1000 ºC for 5 and 15 min caused slight growth and a significant coarsening of the nanoparticles, up to 70 nm and 128 nm, respectively. The ACV analysis indicated the existence of two populations of Y2O3, ε-martensite and MnO. The dispersive X-ray spectrometry (EDS) confirmed two kinds of nanoparticles, Y2O3 and MnO. The material was characterized by superior micro-hardness, of above 500 HV0.1.

36 MATERIALS SCIENCE↗

Ultrasensitive Tip- and Antenna-Enhanced Infrared Nanoscopy of Protein Complexes

Surface enhanced infrared absorption (SEIRA) us-ing resonant plasmonic nanoantennas enables zeptomolar detection sensitivity of (bio)analytes, although with diffraction limited spa-tial resolution. In contrast, infrared scattering-scanning near-field optical microscopy (IR s-SNOM) allows simultaneous imaging and spectroscopy with nanometer spatial resolution through vibrational coupling to the antenna mode of a probe tip. Herein, we combine these two approaches to image distributions of ferritin protein com-plexes adsorbed onto IR-resonant Au nanoantennas. The joint tip- and antenna-enhancement yields single protein complex sensitivity due to coupling with the vibrational modes of the bioanalytes. The coupling is revealed through IR s-SNOM spectra in the form of Fano lineshapes, which can be modelled using coupled harmonic oscillators. The role of the antenna resonance frequency on the cou-pling strength and the sensitivity is explored. Inhomogeneities in protein density within the film can be detected at single protein complex level. This work paves the way for single protein identi-fication and imaging through a combination of tip- and antenna-enhanced IR nanoscopy.

O'Callahan, Brian T.↗

Nanoscale hydration in layered manganese oxides

Birnessite is a layered MnO2 mineral with a nanoscale interlayer region that accommodates layers of intercalated water. Variable distributions of Mn sites with oxidation states of II, III and IV are responsible for the high catalytic reactivity of birnessite in nature and as a valuable candidate for energy storage solutions. We here report water loading capabilities and the vibrational spectral signatures of two forms of birnessite of strongly contrasting particle size. Using X-ray diffraction we find that potassium-birnessite accommodates no more than one monolayer (1W) of water in its interlayer region. Molecular simulations show that this is an energetically favorable hydration state where interlayer potassium-water and direct water-birnessite interactions are greater than at other hydration levels. Simulations also suggest a stable 2W state but that is not achieved experimentally by contact with water vapor. Finally, this work provides a means to predict the distribution of adsorbed and interlayer water molecules using a recently developed composite model.

Cheng, Wei↗