Search NASA⌕ Search

SEARCH · Search NASA

Results for “dilution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Dielectric breakdown in a dilute plasma: A 20 kilovolt limited study

A dielectric breakdown study was made of several materials proposed for high-voltage (16-kV) use on solar-cell arrays at space conditions. The tests were made in an argon plasma whose electron density and temperature approximately simulated conditions at an altitude of 300 km. The maximum voltage used was 20 kV. The results indicate that the breakdown voltages of the materials tested are larger than those quoted in the literature for dielectric between two metal electrodes.

Mckinzie, D. J., Jr.↗

Measured current drainage through holes in various dielectrics up to 2 kilovolts in a dilute plasma

The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.

Grier, N. T.↗

Current drainage to a high voltage probe in a dilute plasma.

The current drainage from a plasma through approximately 0.05 cm diameter holes in Kapton H polymide film, FEP type C, and quartz (7940 Corning glass) placed on a probe at voltages up to 2000 volts dc have been determined both analytically and experimentally. A Laplace field was used to numerically predict an upper limit for the drainage current. The measured current was less than the calculated current for the FEP and quartz, and the two were approximately in agreement for Kapton H. The measured currents were on the order of 5 microamperes with the calculated currents on the order of 10 microamperes.

Grier, N. T.↗

Dielectric breakdown in a dilute plasma.

Description of tests performed to determine the effects of high voltages on dielectrics that are to insulate solar cell arrays operating at voltages up to 16 kV from the electrically active plasma of the space environment at 500 km altitude. The tests were performed on dielectrics considered for this application at positive bias voltages as high as 20 kV dc relative to ground in an argon plasma with electron number densities of approximately one million per cu cm. Teflon specimens displayed higher breakdown voltages than all other dielectrics tested.

Mckinzie, D. J., Jr.↗

Heat transfer coefficients of dilute flowing gas-solids suspensions

Heat transfer coefficients of air-glass, argon-glass, and argon-aluminum suspensions were measured in horizontal and vertical tubes. The glass, 21.6 and 36.0 micron diameter particles, was suspended at gas Reynolds numbers between 11,000 and 21,000 and loading ratios between 0 and 2.5. The presence of particles generally reduced the heat transfer coefficient. The circulation of aluminum powder in the 0.870 inch diameter closed loop system produced tenacious deposits on protuberances into the stream. In the vertical test section, the Nusselt number reduction was attributed to viscous sublayer thickening; in the horizontal test section to particle deposition.

Kane, R. S.↗

Transport equations for dilute plasma in a magnetic field.

Using the Chapman-Enskog procedure, equations are derived for near-equilibrium transport of plasma in a strong magnetic field. It is shown that these equations reduce properly to collision dominated equations and to collisionless Chew-Goldberger-Low (1956) equations in the respective limits. The results presented are more complete than those of Stringer and Connor (1971) and correct their erroneous partition of conducted thermal energy.

Price, J. C.↗

Mixing of multiple dilution jets with a hot primary airstream for gas turbine combustors

The mixing of multiple air jets with a subsonic heated crossflow in a constant area duct was studied experimentally. The jet-to-mainstream momentum flux ratio was varied from 6 to 60. Temperature and pressure surveys were made at several downstream locations for orifice geometries with parametric variation of orifice size and spacing. A mixing efficiency parameter was defined which characterized the effectiveness of the mixing over the range of conditions examined. It was found that for a given momentum flux ratio, there exists a ratio of orifice spacing to duct height which provides the best mixing.

Holdeman, J. D.↗

An Empirical Model for the Mixing of a Row of Dilution Jets with a Confined Crossflow

An empirical model was developed for predicting the temperature distribution downstream from a row of cool jets injected normally into a hot confined crossflow. The model is based on the assumption that all properly non-dimensionalized vertical temperature profiles can be expressed in a self-similar form. The scaling parameters in this form were correlated in terms of the independent flow and geometric variables. The effect of parametric variation of each of the independent variables on the experimental and predicted profiles are examined. The predicted distributions show excellent agreement with the data over a wide range of the independent variables.

Holdeman, J. D.↗

Current from a dilute plasma measured through holes in insulators

The current collected from a plasma through holes in insulated electrodes was measured. Holes of 0.051- and 2.54-cm diameters in Kapton H film and plasma number densities of 100 and 10,000 electrons/cu cm were used. The current collected by bare electrodes, that is, electrodes with no surrounding insulation, is also presented. For all the samples the current at a given voltage was a function of the surrounding insulator area rather than of the hole size or the underlying electrode size. In addition, at the low plasma density the I-V characteristic showed very steep rises for voltages below 1 kV. In one case the current jumped by a factor of approximately 70 to 200 V. Results are given for positive biases to 10 kV. For negative biases, sparking prevented testing most samples to the 10-kV limit.

Grier, N. T.↗

An empirical model for the mixing of a row of dilution jets with a confined crossflow

An empirical model has been developed for predicting the temperature distribution downstream of a row of cool jets injected normal to a hot confined crossflow. The model is based on the assumption that all properly non-dimensionalized vertical temperature profiles can be expressed in a self-similar form. The scaling parameters in this form have been correlated in terms of the independent flow and geometric variables. The effect of parametric variation of each of the independent variables on the experimental and predicted profiles are examined. The predicted distributions show excellent agreement with the data over a wide range of the independent variables.

Holdeman, J. D.↗

Preliminary investigation of elongational flow of dilute polymer solutions

A tubeless siphon apparatus has been set up to measure extensional flow. In this apparatus, the liquid is continuously drawn into a capillary and, after steady flow has been established, the tube is raised above the liquid surface. With viscoelastic liquids, the flow continues and a column can be lifted from the reservoir. At the capillary entrance, an oscillating bead of excess liquid collects which interferes with both the flow and the measurements. This can be minimized by careful control of the liquid-column height. For homogeneous solutions, the column is symmetrical and tapers steadily from the liquid surface to the capillary entrance, with no bulging. Preliminary results show tensile viscosities 1000 times that of the Trouton coefficient and having a very strong dependence on deformation rate. A concentration-stretch rate-reduced variable scheme is proposed.

Peng, S. T. J.↗

Laboratory measurements of radiance and reflectance spectra of dilute primary-treated sewage sludge

The feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge is evaluated. The laboratory arrangement, solar simulator, and test results from three experiments conducted in the laboratory are described. Radiance and reflectance spectra are presented for primary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled reflectance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Well-defined upwelled reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations. The spectral-reflectance values appeared to be influenced by the type of base water, but this influence was small, especially for the mixtures with low concentrations of sewage sludge.

Usry, J. W.↗

Laboratory measurements of radiance and reflectance spectra of dilute secondary-treated sewage sludge

The National Aeronautics and Space Administration (NASA), in cooperation with the Environmental Protection Agency (EPA) and the National Oceanic and Atmospheric Administration (NOAA), conducted a research program to evaluate the feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge. One aspect of the research program involved the measurements of upwelled spectral signatures for sewage-sludge mixtures of different concentrations in an 11600-liter tank. This paper describes the laboratory arrangement and presents radiance and reflectance spectra in the visible and near-infrared ranges for concentrations ranging from 9.7 to 180 ppm of secondary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled radiance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations.

Witte, W. G.↗