Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A search for sources of ultra high energy gamma rays at air shower energies with Ooty EAS array

A 24 detector extensive air shower array is being operated at Ootacamund (2200 m altitude, 11.4 deg N latitude) in southern India to search for sources of Cosmic gamma rays of energies greater then 5 x 10 to the 13th power eV. The angular resolution of the array has been experimentally estimated to be better than about 2 deg. Since June '84, nearly 2.5 million showers have been collected and their arrival directions determined. These showers are being studied to search for very high energy gamma ray emission from interesting astrophysical objects such as Cygnus X-3, Crab pulsar and Geminga.

Tonwar, S. C.↗

Materials International Space Station Experiment (MISSE): Overview, Accomplishments and Future Needs

Materials and devices used on the exterior of spacecraft in low Earth orbit (LEO) are subjected to environmental threats that can cause degradation in material properties, possibly threatening spacecraft mission success. These threats include: atomic oxygen (AO), ultraviolet and x-ray radiation, charged particle radiation, temperature extremes and thermal cycling, micrometeoroid and debris impacts, and contamination. Space environmental threats vary greatly based on spacecraft materials, thicknesses and stress levels, and the mission environment and duration. For more than a decade the Materials International Space Station Experiment (MISSE) has enabled the study of the long duration environmental durability of spacecraft materials in the LEO environment. The overall objective of MISSE is to test the stability and durability of materials and devices in the space environment in order to gain valuable knowledge on the performance of materials in space, as well as to enable lifetime predictions of new materials that may be used in future space flight. MISSE is a series of materials flight experiments, which are attached to the exterior of the International Space Station (ISS). Individual experiments were loaded onto suitcase-like trays, called Passive Experiment Containers (PECs). The PECs were transported to the ISS in the Space Shuttle cargo bay and attached to, and removed from, the ISS during extravehicular activities (EVAs). The PECs were retrieved after one or more years of space exposure and returned to Earth enabling post-flight experiment evaluation. MISSE is a multi-organization project with participants from the National Aeronautics and Space Administration (NASA), the Department of Defense (DoD), industry and academia. MISSE has provided a platform for environmental durability studies for thousands of samples and numerous devices, and it has produced many tangible impacts. Ten PECs (and one smaller tray) have been flown, representing MISSE 1 through MISSE 8, yielding long-duration space environmental performance and durability data that enable material validation, processing recertification and space qualification; improved predictions of materials and component lifetimes in space; model verification and development; and correlation factors between space-exposure and ground-facilities enabling more accurate in-space performance predictions based on ground-laboratory testing. A few of the many experiment results and observations, and their impacts, are provided. Those highlighted include examples on improved understanding of atomic oxygen scattering mechanisms, LEO coating durability results, and polymer erosion yields and their impacts on spacecraft design. The MISSE 2 Atomic Oxygen Scattering Chamber Experiment discovered that the peak flux of scattered AO was determined to be 45 deg from normal incidence, not the model predicted cosine dependence. In addition, the erosion yield (E(sub y)) of Kapton H for AO scattered off oxidized-Al is 22% of the E(sub y) of direct AO impingement. These results were used to help determine the degradation mechanism of a cesium iodide detector within the Hubble Space Telescope Cosmic Origins Spectrograph Experiment. The MISSE 6 Indium Tin Oxide (ITO) Degradation Experiment measured surface electrical resistance of ram and wake ITO coated samples. The data confirmed that ITO is a stable AO protective coating, and the results validated the durability of ITO conductive coatings for solar arrays for the Atmosphere-Space Transition 2 Explorer program. The MISSE 2, 6 and 7 Polymer Experiments have provided LEO AO Ey data on over 120 polymer and composites samples. The flight E(sub y) values were found to range from 3.05 x 10(exp -26) cu cm/atom for the AO resistant polymer CORIN to 9.14 x 10(exp -26) cu cm/atom for polyoxymethylene (POM). In addition, flying the same polymers on different missions has advanced the understanding of the AO E(sub y) dependency on solar exposure for polymers containing fluorine. The MISSE polymer results are highly requested and have impacted spacecraft design for WorldView-2 & -3, the Global Precipitation Measurement-Microwave Imager, and other spacecraft. The flight data has enabled the development of an Atomic Oxygen Erosion Predictive Tool that allows the erosion prediction of new and non-flown polymers. The data has also been used to develop a new NASA Technical Standards Handbook "Spacecraft Polymers Atomic Oxygen Durability Handbook." Many intangible benefits have also been derived from MISSE. For example, over 40 students have collaborated on Glenn's MISSE experiments, which have resulted in greater than $80K in student scholarships and awards in national and international science fairs. Students have also given presentations and won poster competition awards at international space conferences.

Flight Experiment↗

4482 Element Multispectral Hybrid PV/PC HgCdTe IRFPA for High Resolution Coverage of 3.7 - 15.4 Micrometers for the AIRS Instrument

The Atmospheric Infrared Sounder (AIRS) is a key facility instrument in the NASA Earth Observing System (EOS) program, being implemented to obtain comprehensive long-term measurements of earth processes affecting global change. The instrument performs passive IR remote sensing using a high resolution grating spectrometer with a wide spectral coverage (3.7 - 15.4 m) directing radiation onto a hybrid HgCdTe IRFPA operating at 58K in a vacuum package cooled to 155K. The hybrid HgCdTe FPA consists of twelve modules, 10 with multiplexed photovoltaic detectors and two with individually leaded out photoconductive detectors. The complex FPA has a large optical footprint, 53 mm x 66 mm, and receives energy dispersed from the grating through a precision filter assembly containing 17 narrow band filters. The backside illuminated PV detector arrays are fabricated from P-on-n double layer LPE grown heterojunction detectors in a bilinear format of 50 m x 100 m detectors, with from 232 to 420 detectors per module. For the MWIR bands four PV modules cover the 3.7 m to 8.22 m region. Low detector capacitance and low noise preamplifiers in the ROIC are key to achieving high sensitivities in these bands. Uniform quantum efficiencies and detectivities exceeding 3E13 cm-rtHz/W have been achieved. The LWIR region is covered by six PV modules spanning 8.8 m to 13.75 m. High detector resistance and very low ROIC preamplifier input noise are key to achieving high sensitivity. A detectivity exceeding 2E11 cm-rtHz/W has been achieved at the longest wavelength. Two additional PC modules cover the longest spectral bands out to 15.4 m. This high performance multispectral focal plane has been built and integrated with the dewar assembly, and is currently being integrated with the complete AIRS sensor.

Rutter, James↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗

X-ray spectrograph design

An aberration theory is applied to spectrograph design. The initial system considered has a toroidal mirror in front of a concave grating spectrograph, giving spatial resolution perpendicular to the dispersion direction. The accuracy of the theory is shown by comparison of spot diagrams obtained from the aberrations with those produced by raytracing. The major aberrations affecting the vignetting at the intermediate slit and the spatial resolution are identified. A new system, using a holographic grating to give a flat focal plane, is then designed and optimized. It has increased spatial resolution over the wavelength range and is particularly suitable for microchannel array detectors.

Chrisp, M. P.↗

Sun sensor boresight alignment testing for the Halogen Occultation Experiment

The boresight alignment testing for the sun sensor assembly on the Halogen Occultation Experiment (HALOE) is described. The sun sensor assembly consists of three sensors that provide feedback signals for controlling dual axes gimbals. Two energy balancing silicon detectors are operated as wideband sensors in the azimuth and elevation axes. The third sensor is a silicon photodiode array operated as a narrow-band sensor in the elevation axis. These sensors are mounted on a common Invar structure which is mounted to the HALOE telescope. A blackbody was used as the stimulating source to perform the initial boresight alignment and this was checked with a heliostat solar look and a direct solar look. These tests are explained with a comparison between each source used.

Moore, A. S.↗

Recent advances in superconducting-mixer simulations

Over the last few years, considerable progress have been made in the development of techniques for fabricating high-quality superconducting circuits, and this success, together with major advances in the theoretical understanding of quantum detection and mixing at millimeter and submillimeter wavelengths, has made the development of CAD techniques for superconducting nonlinear circuits an important new enterprise. For example, arrays of quasioptical mixers are now being manufactured, where the antennas, matching networks, filters and superconducting tunnel junctions are all fabricated by depositing niobium and a variety of oxides on a single quartz substrate. There are no adjustable tuning elements on these integrated circuits, and therefore, one must be able to predict their electrical behavior precisely. This requirement, together with a general interest in the generic behavior of devices such as direct detectors and harmonic mixers, has lead us to develop a range of CAD tools for simulating the large-signal, small-signal, and noise behavior of superconducting tunnel junction circuits.

Withington, S.↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

InSb arrays: Astronomy with a 32x32 CCD/development of a 58x62 DRO

Experience gained in operating infrared detector arrays for high sensitivity astronomical applications at the University of Rochester are summarized. Progress made in operating the 32 x 32 InSb array with bump-bonded Silicon CCD readout is described. Astronomical work done with the 32 x 32 camera is also described. Plans for the future, including improvements for the 32 x 32 camera system as well as implementing a new generation of 58 x 62 InSb array using switched-MOSFET direct readout multiplexing system in the place of the older CCD technology is discussed.

Forrest, W. J.↗

Focal plane infrared readout circuit

An infrared imager, such as a spectrometer, includes multiple infrared photodetectors and readout circuits for reading out signals from the photodetectors. Each readout circuit includes a buffered direct injection input circuit including a differential amplifier with active feedback provided through an injection transistor. The differential amplifier includes a pair of input transistors, a pair of cascode transistors and a current mirror load. Photocurrent from a photodetector can be injected onto an integration capacitor in the readout circuit with high injection efficiency at high speed. A high speed, low noise, wide dynamic range linear infrared multiplexer array for reading out infrared detectors with large capacitances can be achieved even when short exposure times are used. The effect of image lag can be reduced.

Pain, Bedabrata↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne experiment designed to search for the polarized imprint of gravitational waves from cosmic inflation. The discovery of such a signal would provide direct evidence for inflation, and its characterization would provide a means to explore energy scales orders of magnitude larger than any conceivable particle accelerator. PIPER will consist of two cryogenic telescopes-one for each of the Q and U Stokes parameters. Each will use a variable-delay polarization modulator (VPM) as its first element. This architecture is designed to minimize both T->B and E->B systematics. The detectors will be four 32x40 arrays of BUG detectors, utilizing transition-edge sensors and time-domain multiplexing. Each flight will observe approximately 25% of the sky at a single frequency. Additional flights will increase the frequency coverage.

Chuss, David T.↗

Design and Performance of a Multi-mode Photon-counting Receiver for the NASA O2O Mission

The NASA Orion O2O mission was designed and tested to support high-rate bi-directional optical communications between one of multiple ground sites and a crewed capsule during a 10-day mission. This paper focuses on the design and performance of the receiver that will be based at the NASA White Sands Complex, New Mexico, USA. The main receiver components consist of two 40-cm apertures, each coupled to a specialty multi-mode optical fiber; each fiber coupled to a custom array of superconducting nanowire single-photon detectors; a high-speed, high-channel-count time-to-digital converter; and custom digitizing electronics to perform deserialization, demodulation, clock recovery, and forward error correction with a powerful serially-concatenated pulse-position-modulation turbo code. We show error-free data communication performance up to the maximum required data rate of 267 Mb/s.

optical↗

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Optical radiation measurements II; Proceedings of the Meeting, Orlando, FL, Mar. 27, 28, 1989

The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.

Palmer, James M.↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

Technologies to Enable the Next Great Observatory

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is one of four mission concepts being studied by NASA for the 2020 Decadal Survey in Astronomy and Astrophysics. LUVOIR will be capable of a broad range of science, including: direct imaging and characterization of a wide range of exoplanets and the search for biosignatures on Earth-like planets around sun-like stars; studying galaxy formation and evolution; investigating star and planet formation; and remote sensing of bodies within the Solar System. Enabling a mission as ambitious as LUVOIR requires an array of technologies, such as ultra-stable structures and optics, precision metrology and wavefront sensing, high-contrast imaging techniques, large-format detectors with very low noise, and high-throughput ultraviolet instrumentation. Critically, a systems-level approach must be taken to developing these technologies, guided by architecture studies to place each technology in the appropriate system context.In this poster, we describe LUVOIR's technology needs, as well as current efforts that are actively developing these technologies. We will discuss recent advancements in: measuring picometer-level displacements of optical and structural elements; sub-milli-kelvin thermal sensing and control; non-contact vibration isolation for pointing and dynamic stability; coronagraph design for achieving 10-10 contrast on a segmented system; high-speed metrology for optical system alignment; low-order and out-of-band wavefront sensing for maintaining high-contrast images; low-noise detectors across the ultraviolet, optical, and near infrared bands; broadband coatings with high-reflectivity below Ly. We will also describe a systems approach to coordinating the development of these technologies to achieve the necessary maturity for a LUVOIR mission start in the next decade.

space telescopes↗

Optical Backplane Interconnect Technology (OBIT)

We describe and analyze a novel approach to implementing an Optical Backplane Interconnect Technology (OBIT) that is capable of optically connecting any row of a 32x32 backplane array to any row of a second 32x32 array. Each backplane array is formed monolithically on a wafer. The technology is based on the use of Grating Surface Emitting (GSE) waveguides formed on a wafer containing quantum-well and separate confinement waveguide layers. These layers are used for transverse guiding, gain, modulation, detection, and for the formation of wavelength tunable distributed-Bragg reflector lasers. The required surface structures are formed photolithographically. The GSE waveguides act as efficient antennae that radiate light at angles selected by tuning the wavelength of the lasers. The same waveguides may be used as the receiving antennae when the array is used in the receiving mode. Thus, wavelength tuning is used to direct each row of the transmitting array to the desired row of the receiving array. In summary: The optical backplane array will have the following characteristics: Any row of a 32x32 GSE array may be optically connected to any row of a second 32x32 array. Only one switch decision is required to switch 32 parallel connections to any one of 32 positions. Each monolithic array can be used as both transmitter and receiver by switching the bias on the quantum-well switch-detectors. Separate transmitting and receiving structures could be provided for duplex operation. For a bit error rate of 10 sup 9 at 100-MHz data rate, a required laser power of 12 mW is calculated based on an estimated total optical loss of 40 dB.

Hammer, J. M.↗

Development of the SAMEX vector magnetograph at the Marshall Space Flight Center

A breadboard design to prove the operational feasibility of SAMEX Vector Magnetograph is being developed. Although the breadboard design will not include all of the elements of the original design concept, critical elements such as the large detector array and the high resolution polarimeter will be important parts of the breadboard design to study the data analysis and compression techniques that will be needed in a SAMEX instrument, to study the calibration techniques for systemmatic errors in the polarimeter, and to obtain high resolution vector magnetograms during the next solar maximum. Although the SAMEX polarimeter is not optimum for a ground-based patrol instrument, the design concept can be confirmed with ground-based measurements and direct comparisons with the existing vector magnetograph. The extension of the scientific objectives for this breadboard design is possible if a tunable filter can be acquired.

West, E. A.↗