Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Precisely measuring the distance to the moon

Continuing improvements in the lasers and the detection electronics over the years which have led to accurate measurements of the distance from the earth to the moon are discussed. The first reflector of laser light pulses, deployed on the moon surface twenty years ago by the Apollo 11 astronauts, consisted of 100 fused silica corner cubes, and reflected a beam of light directly back toward its point of origin. Observatories located in Texas, Hawaii, and France now regularly range the moon with an accuracy of approximately 1 inch. Ranging programs have also been carried out in Australia and the Soviet Union. The ranges are computer-analyzed to determine precisely the positions of the observatories on earth, the positions of the reflectors on the moon, the orbit of the moon around the earth, and the rotation and orientation of the earth and the moon. The most important scientific advances derived from lunar ranging are also reviewed.

Faller, J. E.↗

Relationship of Topside Ionospheric Ion Outflows to Auroral Forms and Precipitation, Plasma Waves, and Convection Observed by Polar

The POLAR satellite often observes upflowing ionospheric ions (UFIs) in and near the aurora] oval on southern perigee (approx. 5000 km altitude) passes. We present the UFI features observed by the thermal ion dynamics experiment (TIDE) and the toroidal imaging mass angle spectrograph (TIMAS) in the dusk-dawn sector under two different geomagnetic activity conditions in order to elicit their relationships with auroral forms, wave emissions, and convection pattern from additional POLAR instruments. During the active interval, the ultraviolet imager (UVI) observed a bright discrete aurora on the duskside after the substorm onset and then observed a small isolated aurora form and diffuse auroras on the dawnside during the recovery phase. The UFIs showed clear conic distributions when the plasma wave instrument (PWI) detected strong broadband wave emissions below approx. 10 kHz, while no significant auroral activities were observed by UVI. At higher latitudes, the low-energy UFI conics gradually changed to the polar wind component with decreasing intensity of the broadband emissions. V-shaped auroral kilometric radiation (AKR) signatures observed above -200 kHz by PWI coincided with the region where the discrete aurora and the UFI beams were detected. The latitude of these features was lower than that of the UFI conics. During the observations of the UFI beams and conics, the lower-frequency fluctuations observed by the electric field instrument were also enhanced, and the convection directions exhibited large fluctuations. It is evident that large electrostatic potential drops produced the precipitating electrons and discrete auroras, the UFI beams, and the AKR, which is also supported by the energetic plasma data from HYDRA. Since the intense broadband emissions were also observed with the UFIs, the ionospheric ions could be energized transversely before or during the parallel acceleration due to the potential drops.

Hirahara, M.↗

Detailed examination of a plasmoid in the distant magnetotail with ISEE 3

Details of an investigation of a lone plasmoid encountered by the ISEE-3 spacecraft in February 1983 are reported. ISEE-3 was then at 217 earth radii distance, in the magnetosheath, and had entered the magnetotail. Intense energetic particle, plasma and magnetic field fluctuations were detected, indicating a large electron flux moving tailward, a suprathermal proton flux, a jump in electron temperature, and inverse signatures of an increasing magnetic field. Closed magnetic field lines were also detected as were IMF field lines around the plasmoid and open field lines connecting the earth with space. The hot particles in the plasmoid are concluded to have been magnetically confined in a boundary one earth radius thick. An earthward directed beam was also detected and was found to balance the tailward flux. The origin and characteristics of the beam were not discerned.

Hones, E. W., Jr.↗

Relationship of Topside Ionospheric Ion Outflows to Auroral Forms and Precipitations, Plasma Waves, and Convection Observed by POLAR

The POLAR satellite often observes upflowing ionospheric ions (UFls) in and near the auroral oval on southern perigee (approximately 5000 km altitude) passes. We present the UFI features observed by the thermal ion dynamics experiment (TIDE) and the toroidal imaging mass-angle spectrograph (TIMAS) in the dusk-dawn sector under two different geomagnetic activity conditions in order to elicit their relationships with auroral forms, wave emissions, and convection pattern from additional POLAR instruments. During the active interval, the ultraviolet imager (UVI) observed a bright discrete aurora on the dusk side after the substorm onset and then observed a small isolated aurora form and diffuse auroras on the dawn side during the recovery phase. The UFls showed clear conic distributions when the plasma wave instrument (PWI) detected strong broadband wave emissions below approximately 10 kHz, while no significant auroral activities were observed by UVI. At higher latitudes, the low-energy UFI conics gradually changed to the polar wind component with decreasing intensity of the broadband emissions. V-shaped auroral kilometric radiation (AKR) signatures observed above approximately 200 kHz by PWI coincided with the region where the discrete aurora and the UFI beams were detected. The latitude of these features was lower than that of the UFI conics. During the observations of the UFI beams and conics, the lower-frequency fluctuations observed by the electric field instrument (EFI) were also enhanced, and the convection directions exhibited large fluctuations. It is evident that large electrostatic potential drops produced the precipitating electrons and discrete auroras, the UFI beams, and the AKR, which is also supported by the energetic plasma data from HYDRA. Since the intense broadband emissions were also observed with the UFIs. the ionospheric ions could be energized transversely before or during the parallel acceleration due to the potential drops.

Hirahara, M.↗

Smart materials: strain sensing and stress determination by means of nanotube sensing systems, composites, and devices

The present invention is directed toward devices comprising carbon nanotubes that are capable of detecting displacement, impact, stress, and/or strain in materials, methods of making such devices, methods for sensing/detecting/monitoring displacement, impact, stress, and/or strain via carbon nanotubes, and various applications for such methods and devices. The devices and methods of the present invention all rely on mechanically-induced electronic perturbations within the carbon nanotubes to detect and quantify such stress/strain. Such detection and quantification can rely on techniques which include, but are not limited to, electrical conductivity/conductance and/or resistivity/resistance detection/measurements, thermal conductivity detection/measurements, electroluminescence detection/measurements, photoluminescence detection/measurements, and combinations thereof. All such techniques rely on an understanding of how such properties change in response to mechanical stress and/or strain.

Barrera, Enrique V.↗

Concept of an Opto-electronic Accelerometer System (OAS)

An accelerometer based on a spring-suspended reference mass and its precise relative motion measurement by means of 3 two-dimensional position sensitive detectors (PSD) is described. A breadboard model achieves a resolution (longterm linearity) of 25 nm in one direction. Due to the physical principle of the PSD, the second layer is slightly less sensitive than the top layer; accordingly for gravity gradient detection the more sensitive layer is selected for the Z/X component detection. At 10 Hz sampling rate an acceleration gradient of under 10 to the minus 12th power g (i.e., 0.01 E or 0.001 Gal/km) is considered to be detectable.

Kunkel, B.↗

Reduced electrical bandwidth receivers for direct detection 4-ary PPM optical communication intersatellite links

This interim progress report consists of copies of three reports written for NASA's Flight System Development and Demonstration (FSDD) project on optical intersatellite links. The first report, 'Test results of the PlessCor avalanche photodiode (APD) preamplifier for use in the 50 Mbps quaternary pulse position modulator (QPPM) receiver,' was prepared for NASA Goddard Space Flight Center. The second, 'Performance of Q-ary PPM receiver under additive white Gaussian noise,' was prepared at the request of NASA Lewis Research Center for testing the electronic systems for the FSDD project. The third, 'Use of a Bessel lowpass filter as an approximate raised cosine filter,' was written for raised cosine filter implementation in the FSDD QPPM receiver.

Davidson, Frederic M.↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Upper limits for X-ray and energetic neutral particle emission from Jupiter - Voyager-1 results

The X-ray sensitivity of the low energy proton channels in the Low Energy Charged Particle (LECP) experiment and its directional measurements determined whether X-rays from Jupiter can be recognized as additional flux above background as Voyager 1 approached the planet. Between about 230 and about 100 R(J), a statistically significant count rate was detected interpreted as X-rays and/or neutral particles. Such an X-ray flux leads to estimates of precipitating electrons over the Jovian polar caps which are 200 times larger than over observed electron fluxes in the Io plasma torus.

Kirsch, E.↗

The temporal evolution of 3-m striations in the modified ionosphere

Experiments were performed at Arecibo, Puerto Rico, to investigate the evolution times of 3-m field-aligned striations produced in the ionosphere by powerful high-frequency (HF) radio waves. The results of this investigation are now summarized. First, the striations' rise times are dependent on the HF electric field. The E region data suggest that this dependence is nonlinear. Second, the threshold value of the HF electric field required to produce detectable striations was experimentally determined. At threshold the component of the HF electric field perpendicular to the geomagnetic field is calculated to be 0.09 V/m in the F region and 0.37 V/m in the E region. Third, both the E and the F region data verify theoretical predictions that the striations' decay times are directly proportional to the electron diffusion across B. Finally, a one-to-one correspondence between the growth of the 3-m striations and the decline of the HF-enhanced plasma line during overshoot is sometimes observed.

Coster, A. J.↗

Filamentary current structures in the postnoon sector: Observations from UARS

During an intense geomagentic storm (Kp 7+) that began at approximately 1830 UT on October 1, 1991, the Upper Atmosphere Research Satellite (UARS) satellite encountered the dayside postnoon auroral oval. On two consecutive crossings of the northern hemisphere between 2040 and 2240 UT, the vector magnetometer detected region 1 and 2 Birkeland and ionospheric currents in the postnoon sector. Low-energy electron events were observed near 1400 MLT within a narrow portion of the region 1 current system. Simultaneous magnetic field measurements revealed the presence of intense (approximately 20 microA/sq m) bipolar filament current structures embedded in the auroral oval. The upward-directed currents were associated with the more concentrated region of precipitating electrons. Ions associated with the more intense flux of low-energy electrons exhibited a dispersion signature typical of an ion velocity filter. The dispersion, aligned along the orbit, exhibited higher-energy ions at lower latitudes and earlier local times. The colocation of filament currents and ion dispersion signatures at such late postnoon local times is not consistent with typical E x B 'cusp' dispersions. These features more likely result from dayside boundary wave phenomena.

Bythrow, P. F.↗

Hard X-Ray Emission of X-Ray Bursters

The primary goal of this proposal was to perform an accurate measurement of the broadband x-ray spectrum of a neutron-star low-mass x-ray binary found in a hard x-ray state. This goal was accomplished using data obtained under another proposal, which has provided exciting new information on the hard x-ray emission of neutron-star low-mass x-ray binaries. In "BeppoSAX Observations of the Atoll X-Ray Binary 4U0614+091", we present our analysis of the spectrum of 4U0614+091 over the energy band from 0.3-150 keV. Our data confirm the presence of a hard x-ray tail that can be modeled as thermal Comptonization of low-energy photons on electrons having a very high temperature, greater than 220 keV, or as a non-thermal powerlaw. Such a very hard x-ray spectrum has not been previously seen from neutron-star low-mass x-ray binaries. We also detected a spectral feature that can be interpreted as reprocessing, via Compton reflection, of the direct emission by an optically-thick disk and found a correlation between the photon index of the power-law tail and the fraction of radiation reflected which is similar to the correlation found for black hole candidate x-ray binaries and Seyfert galaxies. A secondary goal was to measure the timing properties of the x-ray emission from neutronstar low-mass x-ray binaries in their low/hard states.

Kaaret, P.↗

Hydrazine Detection with a Tunable Diode Laser Spectrometer

Several instruments have been developed to measure low concentrations of hydrazine but none completely meet the sensitivity requirements while satisfying additional criteria such as quick response, stable calibration, interference free operation, online operation, reasonable cost, etc. A brief review is presented of the current technology including the electrochemical cell, the ion mobility spectrometer, the mass spectrometer, and the gas chromatograph. A review of the advantages and disadvantages of these instruments are presented here. The review also includes commercially unavailable technology such as the electronic nose and the Tunable Diode Laser (TDL) IR Spectrometer. It was found that the TDL could meet the majority of these criteria including fast response, minimum maintenance, portability, and reasonable cost. An experiment was conducted to demonstrate the feasibility of such a system using an existing (non-portable) instrument. A lead-salt tunable diode laser, cooled to 85 degrees Kelvin was used to record direct absorption and second-derivative spectra of Hydrazine at several pressures to study the sensitivity to low levels of Hydrazine. Spectra of NH3 and CO2 were used for wavelength identification of the scanned region. With a pathlength of 80 m, detection sensitivities of about 1 ppb were achieved for hydrazine in dry nitrogen at a cell pressure of 100 mbar. For spectroscopic detection of Hydrazine, spectral regions including strong Ammonia or Carbon Dioxide lines must be avoided. Strong Hydrazine absorption features were identified at 940/cm showing minimal contribution from Ammonia interferences as suitable candidates for Hydrazine gas detection. For the studies reported here, the particular laser diode could only cover the narrow regions near 962/cm and 965/cm where strong Ammonia interferences were expected. However, the high resolution (0.001/cm) of the TDL spectrometer allowed individual lines of Hydrazine to be identified away from interferences from either Ammonia or Carbon Dioxide, especially at lower pressures. A Hydrazine line was identified at 961.75/cm which was free from Ammonia absorption and would be suitable to monitor hydrazine levels. This paper also shows data on the degradation of the detectivity of Hydrazine with increasing pressure. Several design options for a portable unit are presented, including designs with near IR and Quantum Cascade laser components which do not require liquid nitrogen cooling.

Houseman, John↗

Laboratory detection and millimeter spectrum of the MgCCH radical

The pure rotational spectrum of the magnesium monoacetylide radical, MgCCH, has been recorded in the laboratory using millimeter/sub-mm direct absorption spectroscopy. These measurements constitute the first time this molecule has been observed in the laboratory by any spectroscopic method. Seventeen rotational transitions were observed in the frequency range 210-370 GHz for MgCCH, which appears to be a linear molecule with a (sup 2)Sigma ground electronic state. Rotational and fine structure constants were determined for this radical from a nonlinear least squares fit to the data. The rotational rest frequencies measured here will enable astronomical observations to be carried out for MgCCH towards IRC +10216, where the magnesium compounds MgCN and MgNC, as well as many acetylide species, are present.

Anderson, M. A.↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

Optical observations on the CRIT-II Critical Ionization Velocity Experiment

A rocket borne Critical Ionization Velocity (CIV0 experiment was carried out from Wallops Island at dusk on May 4, 1989. Two barium shaped charges were released below the solar terminator (to prevent photoionization) at altitudes near 400 km. The ambient ionospheric electron density was 50,000/cu cm. The neutral barium jet was directed upward and at an angle of nominally 45 degrees to B which gives approximately 3 x 10 to the 23rd neutrals with super critical velocity. Ions created by a CIV process in the region of the neutral jet would travel up along B into sunlight where they can be detected optically. Well defined ion clouds (max. brightness 750 R) were observed in both releases. An ionization rate of 0.8 percent/sec (125 sec ionization time constant) can account for the observed ion cloud near the release field line, but the ionization rate falls off with increasing distance from the release. It is concluded that a CIV process was present in the neutral jet out to about 50 km from the release, which is significantly further than allowed by current theories.

Stenbaek-Nielsen, H. C.↗

The Cosmic Dust Analyzer for Cassini

The Cosmic Dust Analyzer (CDA) is designed to characterize the dust environment in interplanetary space, in the Jovian and in the Saturnian systems. The instrument consists of two major components, the Dust Analyzer (DA) and the High Rate Detector (HRD). The DA has a large aperture to provide a large cross section for detection in low flux environments. The DA has the capability of determining dust particle mass, velocity, flight direction, charge, and chemical composition. The chemical composition is determined by the Chemical Analyzer system based on a time-of-flight mass spectrometer. The DA is capable of making full measurements up to one impact/second. The HRD contains two smaller PVDF detectors and electronics designed to characterize dust particle masses at impact rates up to 10(exp 4) impacts/second. These high impact rates are expected during Saturn ring, plane crossings.

Bradley, James G.↗

The magnetopause electron layer along the distant magnetotail

An energetic electron layer is found immediately adjacent to, and outside of, the magnetopause surface along the distant magnetotail. The layer has been detected by instrumentation aboard the earth-orbiting spacecraft IMP-8 and is observed for electrons with energies above about 200 keV. The present study shows that such electrons form a layer about 3 earth radii thick and are strongly streaming in a well-ordered pattern, especially along the dusk magnetopause. The energy dissipation implied by the persistent flow may be a direct indication of nearly continuous magnetic merging at or near the magnetopause.

Baker, D. N.↗