Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Combustion synthesis of Eu 2 O 3 nanomaterials with tunable phase composition and morphology

Combustion reactions in europium nitrate – acetylacetone – 2-methoxyethanol solutions and gels were investigated to produce europium (III) oxide (Eu 2 O 3 ) nanocrystalline materials and thin films. Thermal analyses of solutions indicated that the 2-methoxyethanol solvent also acts as a fuel in the absence of acetylacetone. Adding acetylacetone increases the overall heat of the reaction. Thermal analysis results revealed that the slow oxidation of unburned hydrocarbon residues follows the primary combustion reaction. Time-temperature profile measurements of the bulk combustion synthesis process in air and nitrogen atmospheres enabled the extraction of the maximum reaction temperature and the heating and cooling rates in the combustion zone. Several direct correlations exist between measured combustion parameters and the phase composition of the products. Combustion in air results in mixed-phase cubic and monoclinic nanocrystalline Eu 2 O 3 . Increasing the acetylacetone concentration in solutions increases the synthesis temperature and decreases the quantity of cubic Eu 2 O 3 . Here, the reaction of solutions in a nitrogen atmosphere or diluted with Eu 2 O 3 provides control of the product phase composition and reduces the quantity of the monoclinic phase. Transmission electron microscopy imaging shows that the Eu 2 O 3 end products are highly porous aggregates of nanocrystalline particles. Electrospraying of reactive solutions onto different substrates followed by short annealing makes the preparation of Eu 2 O 3 materials with diverse morphologies possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of Thermal Conductivity of Bentonite Buffer Materials with Copper Wires/Meshes for High-Level Radioactive Waste Disposal

In high-level radioactive waste disposal, a heat-generating waste canister is generally encased with a layer of bentonite-based buffer material acting as an engineered barrier to limit water percolation and radionuclide release. The low thermal conductivity of bentonite (~0.5 W/m∙K) combined with a high thermal loading waste package may result in a high surface temperature on the package that can potentially impact the structural integrity of the package itself as well as the surrounding buffer material. We show in this paper that the thermal conductivity of bentonite can be effectively enhanced by embedding copper wires/meshes across the buffer layer to form fully connected high heat conduction pathways. A simple calculation based on Rayleigh’s model shows that a required thermal conductivity of 5 W/m∙K for effective heat dissipation can be achieved simply by adding ~1 vol % of copper wires/meshes into bentonite. As a result, the peak surface temperature on a large waste package such as a dual-purpose canister can be reduced by up to 300°C, leading to a significant reduction in the surface storage time for waste cooling and therefore the overall cost for direct disposal of such waste packages. Because of the ensured full thermal percolation across the buffer layer, copper wires/meshes turn out to be much more effective than any other materials currently suggested (such as graphene or graphite) in enhancing the thermal conductivity of buffer material. Furthermore, the embedded copper wires/meshes can help reinforce the mechanical strength of the buffer material, thus preventing the material from a potential erosion by a possible intrusion of dilute groundwater.

36 MATERIALS SCIENCE↗

Power handling in a highly-radiative negative triangularity pilot plant

Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for P SOL = 25 MW and n sep = 0.96 × 10 20 m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature T e remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, P SOL can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.

Miller, M. A. (ORCID:0000000265406533)↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrodynamical Simulations of Proton Ingestion Flashes in Type I X-Ray Bursts

We perform the first multidimensional fluid simulations of thermonuclear helium ignition underneath a hydrogen-rich shell. This situation is relevant to Type I X-ray bursts on neutron stars that accrete from a hydrogen-rich companion. Using the low-Mach number fluid code MAESTROeX, we investigate the growth of the convection zone due to nuclear burning, and the evolution of the chemical abundances in the atmosphere of the star. We also examine the convective boundary mixing processes that cause the evolution to differ significantly from previous one-dimensional simulations that rely on mixing-length theory. We find that the convection zone grows outward as penetrating fluid elements cool the overlying radiative layer, rather than directly from the increasing entropy of the convection zone itself. Simultaneously, these flows efficiently mix composition, carrying carbon out of and protons into the convection zone even before contact with the hydrogen shell. We discuss the implications of these effects for future modeling of these events and observations.

astrophysical fluid dynamics↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

GEOPHIRES files for DDU techno-economic simulations

During 2017-2019, the U.S. Department of Energy funded six geothermal deep direct-use (DDU) projects to investigate feasibility of DDU for heating, cooling and thermal storage in the United States. In a follow-on study conducted at the National Renewable Energy Laboratory (NREL), findings of these six projects were reviewed and analyzed, and additional simulations were conducted using the simulator GEOPHIRES to explore technical performance and cost-competitiveness of DDU. The results of the NREL study were published in the paper "Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States." The GEOPHIRES files developed in that study are included in this submission. The reference for the paper under review is below: Beckers KF, Kolker A, Pauling H, McTigue JD, and Kesseli D (2021) ?Evaluating the Feasibility of Geothermal Deep Direct-Use in the United States?, Submitted to Energy Conversion and Management, Under Review.

15 GEOTHERMAL ENERGY↗

Sensitivity of Neutron-Rich Nuclear Isomer Behavior to Uncertainties in Direct Transitions

Nuclear isomers are populated in the rapid neutron capture process (r process) of nucleosynthesis. The r process may cover a wide range of temperatures, potentially starting from several tens of GK (several MeV) and then cooling as material is ejected from the event. As the r-process environment cools, isomers can freeze out of thermal equilibrium or be directly populated as astrophysically metastable isomers (astromers). Astromers can undergo reactions and decays at rates very different from the ground state, so they may need to be treated independently in nucleosythesis simulations. Two key behaviors of astromers—ground state ↔ isomer transition rates and thermalization temperatures—are determined by direct transition rates between pairs of nuclear states. We perform a sensitivity study to constrain the effects of unknown transitions on astromer behavior. Detailed balance ensures that ground → isomer and isomer → ground transitions are symmetric, so unknown transitions are equally impactful in both directions. We also introduce a categorization of astromers that describes their potential effects in hot environments. We provide a table of neutron-rich isomers that includes the astromer type, thermalization temperature, and key unmeasured transition rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Germplasm cryopreservation of macroalgae for aquaculture breeding and natural resource conservation: A review

The expansion of the global macroalgal aquaculture and climate change creates the need for germplasm preservation of valuable aquaculture strains and maintenance of natural biodiversity. Compared to the large number of studies in fish and shellfish species, relative few studies have been conducted on the macroalgal germplasm cryopreservation. The first cryopreservation of macroalgae to –75 °C was reported on Neopyropia tenera (formerly called Porphyra tenera) in 1964. To date, a total of 34 studies reported germplasm cryopreservation in 33 species, including Chlorophyta (7 species), Ochrophyta (14 species), and Rhodophyta (12 species). Here, the goal of this review was to summarize the published studies on macroalgal germplasm cryopreservation, compare the reported protocols for the cryopreservation process, and identify the factors affecting post-thaw viability. Overall, macroalgal germplasm cryopreservation included haploid or diploid thalli, spores, and gametes. Cryotubes (1.5-ml or 2-ml) have been widely used to package germplasm samples for cooling and storage in most studies, and the 0.5-ml straws and 5-ml cryotubes have been used in several studies. Two approaches (programmable controlled cooling and vitrification) were employed for macroalgal germplasm cryopreservation. A two-step programmable controlled cooling (e.g., from initial culture temperature to a frozen temperature, such as –40 °C, and then directly plunging into liquid nitrogen at –196 °C) was determined to be an effective cooling strategy. Vitrification, a super rapid cooling for a sample to form non-crystalline amorphous solid, was applied on macroalgal germplasm cryopreservation with sample encapsulation and dehydration. Survival of post-thaw samples varied significantly in different studies. Based on research updates, recommendations are made for future research. It is expected that this review can serve as a foundation for future germplasm banking of macroalgae for aquaculture and biodiversity preservation.

59 BASIC BIOLOGICAL SCIENCES↗

Microstructure Alignment Effects from Engineered Cooling during Additive Manufacturing of Alnico Magnets from Prealloyed Powder

Alnico is a rare-earth free; permanent magnet (PM) which maintains its saturation magnetization while at temperatures up to 550°C but lacks the coercivity and energy product needed for a wide range of demanding applications. With an optimal set of processing and manufacturing techniques, Alnico could replace Dy-free Nd-Fe-B magnets in certain applications if the microstructure is textured in a $\langle$001$\rangle$ direction. Additive manufacturing (AM) of near-net-shape magnets may provide such texture. To investigate the possibility, directed-energy deposition (DED) in conjunction with an actively cooled substrate was used to build samples with a compositionally modified, gas-atomized, Alnico 8 alloy. The resulting samples were solutionized and quenched, followed by magnetic annealing and a heat treatment. Magnetic properties and microstructures are compared to previous work.

36 MATERIALS SCIENCE↗

Evaluating cross-sectoral impacts of climate change and adaptations on the energy-water nexus: a framework and California case study

Abstract Electricity and water systems are inextricably linked through water demands for energy generation, and through energy demands for using, moving, and treating water and wastewater. Climate change may stress these interdependencies, together referred to as the energy-water nexus, by reducing water availability for hydropower generation and by increasing irrigation and electricity demand for groundwater pumping, among other feedbacks. Further, many climate adaptation measures to augment water supplies—such as water recycling and desalination—are energy-intensive. However, water and electricity system climate vulnerabilities and adaptations are often studied in isolation, without considering how multiple interactive risks may compound. This paper reviews the fragmented literature and develops a generalized framework for understanding these implications of climate change on the energy-water nexus. We apply this framework in a case study to quantify end-century direct climate impacts on California’s water and electricity resources and estimate the magnitude of the indirect cross-sectoral feedback of electricity demand from various water adaptation strategies. Our results show that increased space cooling demand and decreased hydropower generation are the most significant direct climate change impacts on California’s electricity sector by end-century. In California’s water sector, climate change impacts directly on surface water availability exceed demand changes, but have considerable uncertainty, both in direction and magnitude. Additionally, we find that the energy demands of water sector climate adaptations could significantly affect California’s future electricity system needs. If the worst-case water shortage occurs under climate change, water-conserving adaptation measures can provide large energy savings co-benefits, but other energy-intensive water adaptations may double the direct impacts of climate change on the state’s electricity resource requirement. These results highlight the value of coordinated adaptation planning between the energy and water sectors to achieve mutually beneficial solutions for climate resilience.

54 ENVIRONMENTAL SCIENCES↗

Geothermal Play Fairway Analysis of Low-Temperature Resources for Sedimentary Basin Geothermal Play Types: An Example in the Denver Basin

This project is part of a nationwide effort to highlight the advantages of incorporating low-temperature geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). The initiative aims to hasten the nation's decarbonization process by exploring the potential for using low-temperature geothermal resources (< 150 Degrees Celsius) in selected sedimentary basins that have several population centers. The Play Fairway Analysis (PFA) techniques were modified from earlier studies of sedimentary basin geothermal play types (SBGPTs) that assessed the viability of low-temperature resources. The decision-making process for leveraging low-temperature geothermal resources for GDU and CHP applications is complex and considers a variety of factors, including geological, economic, and risk criteria. This study covers workflows, relevant datasets, python code, and both common and composite maps used to create low-temperature geothermal resource favorability maps for the Denver Basin, which extends across Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. The proposed geothermal PFA approach for low-temperature geothermal resources includes: (1) identifying available relevant data and grouping data sets into PFA criteria (e.g., geological, economic, and risk criteria); (2) analyzing data gaps enable future focalized exploration; (3) performing uncertainty quantification; (4) weighting relevant data; (5) developing favorability and common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection. This project will facilitate future deployment of CHP and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources in sedimentary basins.

15 GEOTHERMAL ENERGY↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Investigation of Innovative Cooling Schemes on an Additively Manufactured Engine Scale Turbine Nozzle Guide Vane

This study includes the design, validation, and fabrication via direct metal laser sintering (DMLS) of a gas turbine nozzle guide vanes (NGV) that incorporates three innovative cooling schemes specifically enabled by additive manufacturing. The novel NGV design is the culmination of an extensive research and development effort over a period of 4 years that included low- and high-speed cascade testing coupled with unsteady computational fluid dynamics for numerous candidate innovative cooling architectures. The final vane design (SJ-vane) consists of sweeping jet (SJ) film cooling holes on the suction surface (SS), sweeping jet impingement holes at the leading edge and double-wall partial length triangular pin-fin with impinging jet at the trailing edge. For comparison purposes, a second DMLS enabled vane (777-vane) was designed and fabricated with prototypical cooling circuits to serve as a baseline. This vane consists of a shaped film cooling holes on the suction surface, circular impingement holes at the leading edge, and full-length cylindrical pin-fins at the trailing edge. Experiments with the two DMLS enabled vanes were performed at the Ohio State University Turbine Reacting Flow Rig (TuRFR) at engine-relevant temperature (1375 K) and Mach number conditions. Infrared (IR) thermography was utilized to measure the wall temperature of the pressure and suction surface at several coolant mass flowrates to estimate the overall cooling effectiveness (&straightphi;). Results showed improved cooling performance for the advanced cooling schemes (sweeping jet film cooling, impingement cooling, and triangular pin-fin cooling) compared with the baseline cooling schemes.

Engineering↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing↗