Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosimetry, internal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Coefficients for Estimating Prenatal Dose in Pregnant Workers from Acute Intakes

Inhalation and ingestion dose coefficients for the embryo and fetus from intakes of radionuclides by the mother are provided in the International Commission on Radiological Protection (ICRP) Publication 88 for intake of each of 74 radionuclides. To address the many other possible radionuclides to which workers may be exposed, effective dose coefficients were developed for the embryo/fetus for all additional radionuclides addressed in ICRP Publication 107 with half-life of 10 min or more. The general approach was to use the estimated dose to the mother’s uterus during pregnancy as a scalable proxy for the dose to the embryo/fetus. The set of scaling factors used in the study was derived from analyses of the relationships of the dose to the mother’s uterus and the effective dose to the embryo/fetus for the ~400 cases (considering two intake modes and multiple forms of many of the radionuclides) addressed in Publication 88.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of ALARA radiation protection on the ISS through polyethylene shielding augmentation of the Service Module Crew Quarters

With 5-7 month long duration missions at 51.6 degrees inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (CnHn) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

Biokinetic models for group IVB elements

The International Commission on Radiological Protection (ICRP) is updating its biokinetic models in a series of reports titled Occupational Intakes of Radionuclides (OIR series). This paper provides an overview of biokinetic data for the group IVB elements hafnium (Hf) and titanium (Ti), compares these data with findings for the more extensively studied Group IVB element zirconium (Zr), and proposes biokinetic models for systemic Hf and Ti for use in the OIR series. A biokinetic model for systemic Zr recently adopted by the ICRP is proposed for application to Hf in view of the nearly identical chemical and physical properties of these two elements, their closely similar behavior in the environment, and their nearly identical biokinetic properties suggested by available comparative data. Finaly, the model structure applied to Zr and Hf is also applied to Ti, but a separate set of transfer coefficients is proposed for Ti.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Workshop on Using a Git-based Repository for ASTM Committee Technical Knowledge Capture [Slides]

Consensus technical standards maintained by ASTM International rely on individual contributors to act as technical contacts, effectively stewards, for a particular standard. As a particular standard’s technical content evolves over time, the contact must update relevant tables, graphics, and supporting discussion. However, the details of the data sources and/or processes used to perform such updates may be separate enough from the standard such that expert knowledge is required to perform these updates. As a result of this need for expert knowledge, and the desire to capture that knowledge, subcommittee E10.05 (Nuclear Radiation Metrology) has experimented with using a git-based repository to capture data and processes to reproduce figures needed by E10.05 to maintain the ASTM standards under their jurisdiction. This workshop will provide an overview of the git-based repository site’s organization, operation, and outputs. It will then lead interested workshop participants through adding content, not yet already included in the repository to the site.

42 ENGINEERING↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Dose reconstruction for plutonium-239 intakes at the Rocky Flats Plant

Purpose: The Rocky Flats (RF) Plant was a weapons manufacturing facility that operated from the early 1950s to 1989. Its primary missions were the production of plutonium (Pu) pits for thermonuclear weapons and the processing of retired weapons for Pu recovery. The purpose of this study was to estimate radiation doses to a cohort of 4499 RF workers from an intake of 239 Pu, the primary plutonium isotope handled at the site. Materials and methods: The latest biokinetic models of the International Commission on Radiological Protection, or site-specific variations of those models, were used to estimate 239 Pu intakes for each worker based on model fits to bioassay data often coupled with lung measurements. Results: Urinary excretion and lung retention data for most 239 Pu intakes could be fit reasonably well by a mixture of Pu dioxide and moderately soluble material. For some workers, better fits were obtained by application of other absorption types including Type S, 239 Pu nitrate, or pure 239 Pu dioxide, or by assuming intake via a wound. The lungs typically received the highest tissue doses, with fifty-year committed equivalent doses in the range of 0.5–1 Sv for 275 workers, 1–5 Sv for 115 workers, and greater than 5 Sv for 12 workers. Conclusions: RF was a unique site regarding a large number of lung measurements available for determining the appropriate absorption types for inhaled material. Further, this provided higher confidence in reconstructed 239 Pu doses than is generally gained from urinary data alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

An age- and sex-specific biokinetic model for radon *

Publication 137 of the International Commission on Radiological Protection (ICRP) describes a biokinetic model for radon used to derive dose coefficients for occupational intake of radon isotopes. The model depicts transfer of inhaled or ingested radon to blood, exchange of radon between blood and tissues, and gradual loss of radon from the body based on physical laws governing transfer of a non-reactive and soluble gas between materials. Here, this paper describes an age- and sex-specific variation of that model developed for use in an upcoming ICRP series of reports on environmental intake of radionuclides by members of the public titled ‘Dose Coefficients for Intakes of Radionuclides by Members of the Public’. The proposed model modifies the model structure and transfer coefficients presented in Publication 137 to allow more realistic dosimetric treatment of bone marrow and breast and expands the model to address pre-adult ages, based on the physical principles used in the development of the model of Publication 137 together with anatomical and physiological changes occurring during human development.

61 RADIATION PROTECTION AND DOSIMETRY↗

2022 Annual Site Environment Report, Princeton Plasma Physics Laboratory

This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. This report fulfills the annual public reporting requirements of DOE Order 231.1B. The results of PPPL’s 2022 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2022. PPPL’s on-site operations started to be restored in 2022, following curtailments in 2020 and 2021 for the global coronavirus (COVID-19) pandemic. PPPL has engaged in fusion energy research since 1951 and at its current locations since 1958. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the U.S. and the world, and to develop the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2022. PPPL is engaged in a project to replace key NSTX-U components and systems to enable the operation of this international magnetic fusion user facility. In 2022, PPPL’s radiological environmental monitoring program measured tritium in the air at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of monitors located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2022, PPPL complied with permit limits for surface water and sanitary wastewater discharges. PPPL was honored with an award for EPEAT-certified electronics purchasing from the Global Electronics Council.

54 ENVIRONMENTAL SCIENCES↗

Summary of Forensic Examinations in Support of Breach Sealed Source Event at Harborview Medical Facility on 2 May 2019

On May 2, 2019, International Isotopes, Inc. (INIS), a subcontractor to Triad National Security, LLC (contractor for Los Alamos National Laboratory) breached a sealed radioactive source containing ~2800 Ci of the radioactive isotope cesium-137 ( 137 Cs) at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of 13 personnel, all 7 floors of the building, and a release of material to the environment. A summary of root and contributing causes of the event was investigated and published by a joint investigation team (JIT) co-led by NNSA and Triad National Security, LLC. That investigation was supported by forensics examinations provided by Pacific Northwest National Laboratory. This report summarizes the results of those forensic examinations.

61 RADIATION PROTECTION AND DOSIMETRY↗

2021 Annual Site Environmental Report

This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. The results of PPPL’s 2021 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2021. PPPL’s on-site operations were significantly curtailed in 2021 due to the global coronavirus pandemic. PPPL has engaged in fusion energy research since 1951. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the U.S. and the world, and to developing the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2021. PPPL is engaged in a project to replace key NSTX-U components and systems to enable operation of this international fusion user facility. In 2021, PPPL’s radiological environmental monitoring program measured tritium in the air at the NSTX-U Stack and at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of an in-stack monitor located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2021, PPPL complied with permit limits for surface and sanitary discharges. PPPL was honored with awards for EPEAT-certified electronics purchasing and use of peracetic acid as an alternative water treatment chemical in its non-potable process water systems an NJDEP recycling award.

54 ENVIRONMENTAL SCIENCES↗

Report of the Sixth Regional Review Meeting of the Radiological Security Partnership.

The Sri Lanka Atomic Energy Regulatory Commission (AERC) and the United States Department of Energy (U.S. DOE) co-hosted the 6th Regional Review Meeting on Radiological Security involving representatives from over 20 countries, the International Atomic Energy Agency (IAEA), the International Criminal Police Organization (INTERPOL), and the World Institute for Nuclear Security. The purpose of the event was to discuss the implementation of, and plans for, high-activity radioactive source security (RSS). The U.S. DOE’s National Nuclear Security Administration (NNSA) Office of Radiological Security (ORS) fully sponsored this review meeting. Participants were welcomed to Colombo, Sri Lanka, and the meeting was formally opened by Nirmali Karunarathna of the Sri Lanka Atomic Energy Regulator Council who emphasized the strong partnerships among the participants. The opening Ceremony and Lamp Lighting included dignitaries from the sponsoring countries. Robert Hilton, Deputy Chief of Mission at the U.S. Embassy in Colombo, and Kristin Hirsch of the ORS gave other opening remarks that highlighted the social benefit from radiological sources in medicine, industry, and agriculture, while stressing the importance of addressing the risks associated with the malicious use of radiological sources. Emphasis was placed on the importance of partnerships among all the participants to help ensure the success of securing radiological materials throughout the world and the opportunity to share information and experiences. AERC was acknowledged with special thanks for hosting this event. A participant list is included as Attachment A, and the meeting agenda is provided as Attachment B. All presentations were made available to participants. The following sections summarize the meeting’s presentations, discussions, issues, suggestions, and recommendations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Basis for the ICRP’s updated biokinetic model for systemic astatine

The International Commission on Radiological Protection (ICRP) recently updated its biokinetic models for workers in a series of reports called the OIR (occupational intakes of radionuclides) series. A new biokinetic model for astatine (At), the heaviest member of the halogen family, was adopted in OIR Part 5 (ICRP in press). Occupational intakes of radionuclides: Part 5). Furthermore, this paper provides an overview of available biokinetic data for At; describes the basis for the ICRP's updated model for At; and tabulates dose coefficients for intravenous injection of each of the two longest lived and most important At isotopes, 211 At and 210 At. At-211 (T 1/2 = 7.214 h) is a promising radionuclide for use in targeted α-particle therapy due to several favourable properties including its half-life and the absence of progeny that could deliver significant radiation doses outside the region of α-particle therapy. At-210 (T 1/2 = 8.1 h) is an impurity generated in the production of 211 At in a cyclotron and represents a potential radiation hazard via its long-lived progeny 210 Po (T 1/2 = 138 days). Tissue dose coefficients for injected 210 At and 211 At based on the updated model are shown to differ considerably from values based on the ICRP's previous model for At, particularly for the thyroid, stomach wall, salivary glands, lungs, spleen, and kidneys.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Misclassification of causes of death among a small all-autopsied group of former nuclear workers: Death certificates vs. autopsy reports

The U.S. Transuranium and Uranium Registries performs autopsies on each of its deceased Registrants as a part of its mission to follow up occupationally-exposed individuals. This provides a unique opportunity to explore death certificate misclassification errors, and the factors that influence them, among this small population of former nuclear workers. Underlying causes of death from death certificates and autopsy reports were coded using the 10 th revision of the International Classification of Diseases (ICD-10). These codes were then used to quantify misclassification rates among 268 individuals for whom both full autopsy reports and death certificates with legible underlying causes of death were available. When underlying causes of death were compared between death certificates and autopsy reports, death certificates correctly identified the underlying cause of death’s ICD-10 disease chapter in 74.6% of cases. The remaining 25.4% of misclassified cases resulted in over-classification rates that ranged from 1.2% for external causes of mortality to 12.2% for circulatory disease, and under-classification rates that ranged from 7.7% for external causes of mortality to 47.4% for respiratory disease. Neoplasms had generally lower misclassification rates with 4.3% over-classification and 13.3% under-classification. A logistic regression revealed that the odds of a match were 2.8 times higher when clinical history was mentioned on the autopsy report than when it was not. Similarly, the odds of a match were 3.4 times higher when death certificates were completed using autopsy findings than when autopsy findings were not used. This analysis excluded cases where it could not be determined if autopsy findings were used to complete death certificates. The findings of this study are useful to investigate the impact of death certificate misclassification errors on radiation risk estimates and, therefore, improve the reliability of epidemiological studies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Safety [Vol. 32, No. 1, January-March 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 The Safety Review and Approval Process for Space Nuclear Power Sources, G. L. Bennett; 19 Report on the American Nuclear Society International Topical Meeting: "The Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities", E. G. Silver; 35 Book Review: Fission Product Transport Processes in Reactor Accidents, Proceedings to the International Centre tor Heat and Mass Processes T. S. Kress; 38 Fast Reactor Technology in the 1990s: A Summary of the 1990 International Fast Reactor Safety Meeting, A. E. Levin; ACCIDENT ANALYSIS: 56 Effects of Chemical Phenomena on LWR Severe Accident Fission Product Behavior, A. P. Malinauskas and T. S. Kress; CONTROL AND INSTRUMENTATION: 65 Technical Note: Safety Parameter Display Systems—10 Years Later, R. J. Eckenrode; 68 Potential Application of Neural Networks to the Operation of Nuclear Power Plants, R. E. Uhrig; DESIGN FEATURES: 80 Twenty-First DOE/NRC Nuclear Air-Cleaning Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 91 Impact of an Apparent Radiation Embrittlement Rate on the Life Expectancy of PWR Vessel Supports, R. D. Cheverton, G. C. Robinson, W. E. Pennell, and R. K. Nanstad; ENVIRONMENTAL EFFECTS: 103 Technical Note: The Impact of Offsite Factors on the Safety Performance of Small Nuclear Power Plants, Yu. D. Baranaev and A. N. Viktorov; WASTE AND SPENT FUEL MANAGEMENT: 109 Activities Related to Waste Management, Compiled by E. G. Silver; OPERATING EXPERIENCES: 118 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 121 Selected Safety-Related Events, Compiled by G. A. Murphy; 123 Operating U.S. Power Reactors, Compiled by E. G. Silver; RECENT DEVELOPMENTS: 140 General Administrative Activities, Compiled by E. G. Silver; 150 Reports, Standards, and Safety Guides, D. S. Queener; 155 Status of Power-Reactor Licensing Activities, Compiled by E. G. Silver; 157 Proposed Rule Changes as of Sept. 30, 1990; ANNOUNCEMENTS: 79 MIT Offers Summer Program on Nuclear Power Reactor Safety; 108 Harvard School of Public Health Offers Several Short Courses; 139 Short Course and Workshop on Nuclear Criticality Safety at University of New Mexico; 160 SCK/CEN Announces Training Course on Emergency Planning and Response; 161 The Authors; 164 Indexes to Nuclear Safety, Volume 31

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗