Search NASA⌕ Search

SEARCH · Search NASA

Results for “drop size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Differential reflectivity (Z-DR) measurements of rainfall compared with ground-based disdrometer measurements

The dual-polarization differential-reflectivity (Z-DR) radar technique of Seliga and Bringi (1976) is used to determine rainfall rates and drop sizes over a site located at a distance of 47.1 km, and the results are analyzed using the empirical calibration relations of Seliga et al. (1983) and compared with electromechanical-disdrometer measurements. The data are presented in graphs and found to be well correlated, demonstrating the validity of the Z-DR estimates and the improvement introduced by applying the empirical relations rather than an a priori drop-size distribution.

Direskeneli, H.↗

The effect of fuel sprays on emissions from a gas turbine combustor

A research gas turbine combustor which allows for independent control of drop size, fuel/air ratio, air inlet temperature, pressure, reference velocity, and residence time has been used to study the influence of fuel spray characteristics on primary zone emissions. Local concentrations of oxides of nitrogen, carbon monoxide and unburned hydrocarbons at various locations in the flow, local gas temperature, gas velocity, and the turbulence intensity (measured with laser velocimetry) are obtained. A comprehensive data analysis program to compute the local fuel/air ratio and the sum of the mole fractions of the species present confirms the validity of the emissions data. Increasing drop size is correlated with an increase in unburned hydrocarbons, while increasing residence time is associated with sharp decreases in hydrocarbons and carbon monoxide and an increase in oxides of nitrogen.

Nicholls, J. A.↗

SLD Instrumentation in Icing Wind Tunnels – Investigation Overview

A collaborative effort to better understand cloud characterization probes in Supercooled Large Drop (SLD) conditions, as well the ability to simulate these conditions in several icing wind tunnels, was undertaken by NASA, NRCC, CIRA, ECCC, FAA and Met Analytics, Inc. Both drop sizing and liquid water content, LWC, were measured with various probes using current to emerging technologies. To ensure the best possible data quality from the newest probes, the probe manufacturers, SEA, Inc. and Artium, Inc. were invited to support testing and data analysis efforts. A common set of probes was identified to test in each of the three participating facilities: NRCC’s Altitude Icing Wind Tunnel, NASA’s Icing Research Tunnel and CIRA’s Icing Wind Tunnel. From the common set of probes, a subset were identified to use for comparison across the three facilities. These were the CDP-2 and 2D-S for drop sizing, and the Multi-wire for LWC. The LWC value was also checked by measuring the ice accretion thickness under hard rime conditions on a NACA-0012 airfoil. A common test matrix with sweeps in both LWC and median volume diameter, MVD, was developed. Each facility achieved these conditions as determined by their own calibration. The MVD ranged from 20 to at least 200 um, and LWC ranged from 0.5 to 3 g/m3. The comparison probes tested at common conditions in each facility were intended to allow for a direct comparison, and check of potential facility bias.

Icing Wind Tunnel↗

Experimental studies on effervescent atomizers with wide spray angles

An experimental investigation was conducted to examine the operating and spray characteristics of two internal-mixing twin-fluid atomizers that were designed to produce effervescent atomization at low air/liquid mass ratios (ALR's). These two experimental atomizers ejected the two phase flow so as to produce a wide spray angle. One atomizer was a plain orifice design that used a four-hole exit orifice which divided and turned the two phase flow just prior to ejection. The other atomizer, called the conical sheet atomizer, ejected the two phase flow through an annular passage in such a way as to form a hollow cone spray. The atomizer operating parameters varied during this investigation were the air/liquid mass ratio, atomizer operating pressure, and, in the case of the conical sheet atomizer, the exit gap width. Studies of spray characteristics included measurements of the spray Sauter mean diameter (SMD), drop size distribution, and, for the conical sheet atomizer, circumferential distribution of the liquid mass within the spray. For both atomizers it was found that SMD decreases with an increase in either ALR or operating pressure. The effect of ALR on SMD diminishes as the value of ALR increases. For the conical sheet atomizer, when operating at low values of pressure and ALR, SMD increases with increase in gap width, but the influence of gap width on SMD diminishes with an increase in either pressure or ALR. At the highest operating pressure of the conical sheet atomizer (552 kPa), SMD is independent of gap width at all ALR's. For both atomizers, changes in operating pressure and ALR have little effect on the distribution of drop sizes in the spray.

Whitlow, J. D.↗

Structure of a Swirl-stabilized, Combusting Spray

Measurements of the structure of a swirl-stabilized, reacting spray are presented. The configuration consisted of a research air-assist atomizer located in the center surrounded by a coflowing air stream. Both the air assist and coflow streams had swirl imparted to them in the same direction with 45 degree angle swirlers. The fuel and air entered the combustor at ambient temperature and the combustor was operated in an unconfined environment. The gas phase was seeded with aluminum oxide particles in order to obtain velocity measurements. Velocity measurements for the gas phase are reported for both an isothermal, single-phase case without drops and a reacting spray case at axial distances from 2.5 to 350 mm downstream of the nozzle. Both mean and fluctuating values are reported. Heptane fuel was used for all the experiments. Drop size and velocity, and drop number flux are also reported for five axial distances downstream. Both mean and fluctuating values are reported for the drops. The measurements were performed using a two-component phase/Doppler particle analyzer. Profiles across the entire flowfield where velocities were significant are presented. Mean gas phase temperatures were also measured intrusively using a single pt/pt-13 percent rh thermocouple and are reported at axial distances from 2.5 to 200 mm downstream of the nozzle.

Bulzan, Daniel L.↗

Two phase detonation studies

An experimental study of the passage of a shock wave over a burning fuel drop is described. This includes high speed framing photographs of the interaction taken at 500,000 frames per second. A theoretical prediction of the ignition of a fuel drop by a shock wave is presented and the results compared with earlier experimental work. Experimental attempts to generate a detonation in a liquid fuel drop (kerosene)-liquid oxidizer drop (hydrogen peroxide)-inert gas-environment are described. An appendix is included which gives the analytical prediction of power requirements for the drop generator to produce certain size drops at a certain mass rate. A bibliography is also included which lists all of the publications resulting from this research grant.

Nicholls, J. A.↗

Structure of a swirl-stabilized combusting spray

Measurements of the structure of a swirl-stabilized, reacting spray are presented. The configuration consisted of a research air-assist atomizer located in the center surrounded by a co-flowing airstream. Both the air-assist and co-flowing streams had swirl imparted to them in the same direction with 45-deg angle swirlers. The fuel and air entered the combustor at ambient temperature and the combustor was operated in an unconfined environment. The gas phase was seeded with aluminum-oxide particles in order to obtain velocity measurements. Mean velocity measurements for the gas phase are reported for both an isothermal, single-phase case without drops and a reacting spray case at axial distances from 2.5 to 50 mm downstream of the nozzle. Heptane fuel was used for all the experiments. Drop size and mean velocity and drop number flux are also reported for five axial distances downstream. The measurements were performed using a two-component phase/Doppler particle analyzer. Profiles across the entire flowfield where velocities were significant are presented. Mean gas-phase temperatures were also measured intrusively using a single pt/pt-13%rh thermocouple and are also reported at axial distances from 2.5 to 50 "im downstream of the nozzle.

Bulzan, Daniel L.↗

Ultrasonics and Optics Would Control Shot Size

Feedback system assures production of silicon shot of uniform size. Breakup of silicon stream into drops is controlled, in part, by varying frequency of vibrations imparted to stream by ultrasonic transducer. Drop size monitored by photodetector. Control method particularly advantageous in that constant size is maintained even while other process variables are changed deliberately or inadvertently. Applicable to materials other than silicon.

Morrison, A. D.↗

Phase segregation due to simultaneous migration and coalescence

Ground-based modeling and experiments have been performed on the interaction and coalescence of drops leading to macroscopic phase separation. The focus has been on gravity-induced motion, with research also initiated on thermocapillary motion of drops. The drop size distribution initially shifts toward larger drops with time due to coalescence, and then a back towards smaller drops due to the larger preferentially settling out. As a consequence, the phase separation rate initially increases with time and then decreases.

Davis, Robert H.↗

Comparison of two different raindrop disdrometers

Different types of impact sensors, used for the measurement of drop size distribution, are described and compared. All of them generate an electrical output which is to a first order a function of the velocity and mass of impacting drops within the size range of 0.25 to 5.0 mm. The disdrometers discussed include an active styrofoam disdrometer, a passive plexiglass sensor, and a cast epoxy disdrometer sensor. The sensors are calibrated by dropping water drops of known size on the sensor, and using an oscilloscope to measure peak amplitude. Similar response characteristics are observed for the active styrofoam disdrometer and the passive plexiglass and brass sensors. The cast epoxy impact sensor is noted to have a faster response and to be more sturdy than the styrofoam or plexiglass sensors.

Rowland, J. R.↗

Estimating the Concentration of Large Raindrops from Polarimetric Radar and Disdrometer Observations

Estimation of rainfall integral parameters, including radar observables, and empirical relations between them are sensitive to the truncation of the drop size distribution (DSD), particularly at the large drop end. The sensitivity of rainfall integral parameters to the maximum drop diameter (D(sub max)) is exacerbated at C‐band since resonance effects are pronounced for large drops in excess of 5 mm diameter (D). Due to sampling limitations, it is often difficult to reliably estimate D(sub max) with disdrometers. The resulting uncertainties in D(sub max0 potentially increase errors in radar retrieval methods, particularly at C‐band, that rely on disdrometer observations for DSD input to radar models. In fact, D(sub max) is typically an assumed DSD parameter in the development of radar retrieval methods. Because of these very uncertainties, it is difficult to independently confirm disdrometer estimates of D(sub max) with polarimetric radar observations. A couple of approaches can be taken to reduce uncertainty in large drop measurement. Longer integration times can be used for the collection of larger disdrometer samples. However, integration periods must be consistent with a radar resolution volume (RRV) and the temporal and spatial scales of the physical processes affecting the DSD therein. Multiple co‐located disdrometers can be combined into a network to increase the sample size within a RRV. However, over a reasonable integration period, a single disdrometer sample volume is many orders of magnitudes less than a RRV so it is not practical to devise a network of disdrometers that has an equivalent volume to a typical RRV. Since knowledge of DSD heterogeneity and large drop occurrence in time and space is lacking, the specific accuracy or even general representativeness of disdrometer based D(sub max) and large drop concentration estimates within a RRV are currently unknown. To address this complex issue, we begin with a simpler question. Is the frequency of occurrence of large rain drops (D > 5 mm) in disdrometer observations, either stand alone or networked, generally representative and consistent with polarimetric radar observations? We first show from simulations that the concentration of large (D > 5 mm) rain drops (N(sub T5)) can be estimated from polarimetric observations of specific differential phase (K(sub dp)) and differential reflectivity (Z(sub dr)), N(sub T5)=F(K(sub dp),Z(sub dr)), or horizontal reflectivity (Z(sub h)) and Z(sub dr), N(sub T5)=(Z(sub h),Z(sub dr)). We assess the error associated with polarimetric retrieval of N(sub T5), including sensitivity to D(sub max) parameterization assumptions and measurement error in the radar simulations. Polarimetric measurements at S‐band and C‐band will then be used to retrieve estimates of N(sub T5) and compared to disdrometer estimates of N(sub T5). After careful consideration of retrieval error, we will check consistency between disdrometer and polarimetric radar estimates of N(sub T5) and the frequency of occurrence of large rain drops in a variety of precipitating regimes using data from NASA's Global Precipitation Measurement (GPM) Ground Validation (GV) program, including field campaigns such as MC3E (Oklahoma) and IFloodS (Iowa) and extended measurements over Huntsville, Alabama and NASA Wallops Flight Facility in coastal Virginia.

Carey, Lawrence D.↗

NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration Procedure and Results

The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are presented. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C ('typical' icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

liquid water content↗

NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration

The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are being presented to the SAE AC-9C committee, as represented in the 2014 cloud calibration report. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C (typical icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

drop size↗

The role of drop velocity in statistical spray description

The justification for describing a spray by treating drop velocity as a random variable on an equal statistical basis with drop size was studied experimentally. A double-exposure technique using fluorescent drop photography was used to make size and velocity measurements at selected locations in a steady ethanol spray formed by a swirl atomizer. The size-velocity data were categorized to construct bivariate spray density functions to describe the spray immediately after formation and during downstream propagation. It was found that a statistical treatment of drop velocity was supported by the data. Spray density function shapes and modal characteristics depended strongly on position and the amount of droplet-gas interaction that had occurred. Bimodal density functions were formed by environmental interaction during downstream propagation. Large differences were also found between spatial mass density and mass flux size distributions at the same location.

Groeneweg, J. F.↗

Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods

Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗