Search NASA⌕ Search

SEARCH · Search NASA

Results for “dwellings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterization of Spall in Hard Rock from Observations and Simulations of the Source Physics Experiment Phase I

In this work, spall signals from the Source Physics Experiments are presented, analyzed, and modeled for insight to the explosion source. The observed signal is similar in nature to nearby historical nuclear explosions, and the surface force-time history or velocity can be interpreted with the same model. We use the models for peak spall velocity, spalled mass, and spall depth and radius derived from historical nuclear explosions to parameterize the physical force-time history model from Stump (1985) and show that this parameterized model can be used for spall prediction. The spall signal is also investigated with a numerical continuum model that incorporates gravity. Peak velocity and dwell time are well predicted, and the multiple slap-down phases are captured if one includes a weak near-surface layer similar to the geologic observation.

58 GEOSCIENCES↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes

Cost is a major barrier when upgrading homes to reduce carbon emissions required to meet DOE’s climate-related goals. This report summarizes a nationwide effort to gather home energy upgrade project cost data along with household energy performance data. The goal was to develop cost benchmarks and to guide future R&D efforts aimed at cost compression and scaling of the residential upgrade market. The cost data were compiled for both total project costs and costs of individual measures. The majority of energy savings were modeled, with some models using measured site data for calibration. The database was analyzed using clustering techniques to find common energy and CO2 reduction approaches. The individual measures were combined into archetypal solutions to determine least-cost approaches to maximizing energy and carbon savings. Several financial analyses were preformed to examine other cost metrics beyond first cost. Project data was obtained for 1,739 projects, from 15 states and 12 energy programs, with a total of 10,512 individual measures. The database includes a wide-array of projects, ranging from single-measure HVAC upgrades to net-zero energy whole home remodels. Projects were predominantly single-family detached dwellings with wood frame construction. Most of the data was obtained from energy programs because they had recorded the necessary information and were willing to share with this study. This sample of convenience can provide broad guidance and national cost benchmarks, but lacks sufficient detail to draw more disaggregated conclusions, such as geographical trends. The majority of data contributions were obtained without compensation from sources where the required data was already in some sort of structured format. We compensated sources to enter data from individual projects into a structured data format for about 500 projects, with an average cost of about $40 per project. The database was highly skewed to lower cost, lower impact projects due to the nature of the sample of convenience. Less than 10% of projects had savings greater than 50%. The cost data for individual measures in the database are being used in other DOE efforts on residential energy use/decarbonization. This data collection effort should continue in order to provide the best-informed guidance for DOE and industry R&D, as well as deployment efforts (including policy and program planning).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficient Thermoplastic Composite Manufacturing

The objective of the project was to establish an effective and affordable method to lay-up and consolidate/join large thermoplastic composite aerospace structure with cycle times measured in minutes rather than hours. Composite airplane designs have proven efficient and effective however future potential product production rates are challenging what the current systems can efficiently produce due to material lay-down constraints and extended thermal cycle times. The ability to lay-up then rapidly heat, consolidate, and cool large complex composite structures plus very accurately tool them (i.e. matching CTE of composite materials) along with very precise thermal control is a difficult challenge. Current systems such as autoclave processing of thermoset materials require long cycle times due to method of heating and the large associated thermal masses. These extended cycle times inhibit the ability to meet higher rate production scenarios due to the need for multiple sets of equipment and tools. Thermoplastic composite materials were used to facilitate more rapid cycle times via the elimination of a need for a cure dwell at temperature. Also, utilized induction heating along with smart susceptors to enable the quick cycle times needed while providing precise intrinsic thermal control. The intrinsic control of the induction heating process via the smart susceptors along with the use of laser assisted fiber placement were the key innovations areas developed. The ability to rapidly heat and then precisely control the temperature of the consolidation component was paramount to the success of this project. It is this unique processing attribute coupled with the thermoplastic material characteristics along with rapid lay-up methods that are novel and advantageous. While many requirements and influencing factors decide the materials and processes utilized for future airplane construction, the forecast of accelerated production rates and the recent performance successes of composites in airplane construction provide an opportunity for this processing technology to have significant influence. During the course of this project a number of key accomplishments were completed. They are as follows: The needed laser assisted fiber placement capabilities have been developed and validated on a component of meaningful scale and complexity. Subsequently, a thermoplastic preform of the part scale-up part design was laser assisted fiber placed and made availalbe for consolidation. An induction consolidation system was sized, designed, and fabricated resulting in the full capability to consolidate the scale-up component. The tool for induction consolidating of the scale-up component was designed and fabricated. An aluminum pressure bladder was welded and formed for use as the pressurization membrane to perform the needed application of pressure on the part at temperature to achieve consolidation. The induction consolidation system consisting of the restraint, induction power supply, induction tool with integrated induction coils and smart susceptor liners, along with the aluminum bladder were successfully used to consolidate a large thermoplastic skin. The capability of accomplishing rapid heat-up rates and cool down rates for consolidation of large thermoplastic skins with precise thermal control and even pressure application at the consolidation temperature was validated. The general conclusion is that the use of induction consolidation with smart susceptors is an effective method to rapidly and efficiently consolidate large thermoplastic composite components and enable affordable high rate manufacturing of composites. More specific conclusions generated by this project are as follows: A restraint type induction consolidation system provides an affordable option over the standard press when using the induction consolidation processing method. Aluminum bladders can be formed to the complex shapes needed and supply uniform pressure for consolidation and co-consolidation of thermoplastic composite materials. Straightforward modifications can be made to existing fiber placement robotic systems to enable their use for thermoplastic lay-up applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Integration to Gain Commercial Efficiency for the Urban Goods Delivery System, Meet Future Demand for City Passenger and Delivery Load/Unload Spaces, and Reduce Energy Consumption

This three-year project supported by the U.S. Department of Energy Vehicle Technologies Office has the potential to radically improve the urban freight system in ways that help both the public and private sectors. Working from 2018-2021, project researchers at the University of Washington’s Urban Freight Lab and collaborators at the Pacific Northwest National Laboratory have produced key data, tested technologies in complex urban settings, developed a prototype parking availability app, and helped close major knowledge gaps. All the fruits of this project can be harnessed to help cities better understand, support and actively manage truck load/unload operations and their urban freight transport infrastructure. Project learnings and tools can be used to help make goods delivery firms more efficient by reducing miles traveled and the time it takes to complete deliveries, benefitting businesses and residents who rely on the urban freight system for supplies of goods. And, ultimately, these project learnings and tools can be used to make cities more livable by minimizing wasted travel, which, in turn, contributes to reductions in fuel consumption and emissions. Cities today are challenged to effectively and efficiently manage their infrastructure to absorb the impacts of ever-increasing e-commerce-fueled delivery demand. All delivery trucks need to park somewhere to unload and load. Yet today’s delivery drivers have no visibility on available parking until they arrive at a site, which may be full. That means they can wind up cruising for parking, which wastes time and fuel and contributes to congestion. Once drivers do find parking, the faster they can unload at the spot, the faster they free up space for other drivers, helping others avoid circling for parking. This makes the parking space—and thus the greater load/unload network—more productive. To this end, the research team successfully met the project’s three goals, developing and piloting strategies and technologies to: 1. Reduce parking-seeking behavior in the study area by 20%; 2. Reduce parcel truck dwell time (the time a truck spends in a spot to load/unload) in the study area by 30%; 3. Increase curb space, alley space and private loading bay occupancy rates in the study area. The research team met these goals by creating and piloting on Seattle streets OpenPark, a first-of-its-kind real-time and forecasting curb parking app customized for commercial delivery drivers—giving drivers the “missing link” in their commonly used routing tools that tell them how best to get to delivery locations, but not what parking is available to use when they get there. Installing in-ground sensors on commercial vehicle load zones (CVLZs) and passenger load zones (PLZs) in the 10-block study area in Seattle’s downtown neighbourhood of Belltown let researchers glean real-time curb parking data. The research team also met project goals by piloting three parcel lockers in public and private spaces open to any delivery carrier, creating a consolidated delivery hub that lets drivers complete deliveries faster and spend less time parked. Researchers collected and analysed data to produce the first empirical, robust, statistically significant results as to the impact of the lockers, and app, on on-the-ground operations. In addition to collecting and analyzing sensor and other real-time and historical data, researchers rode along with delivery drivers to confirm real-world routing and parking behavior. Researchers also surveyed building managers on their private loading bay operations to understand how to boost usage.

97 MATHEMATICS AND COMPUTING↗

Developing Residential Energy Usage Baselines and Energy Efficiency Options

FCPC has been a leader in energy conservation not only in the State of Wisconsin, but nationally, as well. In 2016, the Environmental Protection Agency (EPA) ranked FCPC 11th in its Top 30 Local Government List as a result of the extensive measures the Tribe has taken toward its goal of achieving 100% carbon-neutral energy independence. Some of these efforts include the reduction of the Tribal government workweek to four days instead of five, the purchase of renewable energy certificates to more than offset the Tribe’s annual energy consumption, the installation of solar photovoltaic systems, and the completion of energy audits of Tribal government facilities. Until now, FCPC has focused on energy efficiency options for government and enterprise buildings, but it is now time to broaden the scope of energy efficiency to include the Tribe’s residential community. The Tribe’s Energy Working Group has identified the completion of home energy audits as one of its more imminent goals, as formal energy evaluations have yet to be completed on residential dwellings on the FCPC reservation. Tribal leadership is already looking ahead to the anticipated outcome of these energy audits and has taken steps to develop a cost sharing program that will assist Tribal homeowners to implement identified efficiency options as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Core-Shell Heterostructures as Functional Materials for Solid Oxide Fuel Cell (SOFC) Electrodes

The principal objective of this project was to synthesize core-shell heterostructures for solid oxide fuel cell cathodes using a molten salt solvent. In doing so, the main goals were split into a) to elucidate and understand the influence of molten salt chemistries to expeditiously synthesize perovskite type oxides for solid oxide fuel cells, b) provide a chemical framework for future molten salt syntheses of energy relevant ceramic materials, c) demonstrate and investigate the required parameters for the optimal core-shell synthesis and yield of La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) – La 0.8 Sr 0.2 MnO 3 (shell), and d) demonstrate improved cathode performance of core-shell LSCF-LSM compared to an LSCF cathode on symmetric cells. The results clearly show that a) the influence of the molten salt cation outweighs the anion in regards to product stoichiometry, b) molten salts should be tailored to balance cationic and anionic acidity for high product yield, c) high yield of core-shell nanoparticles can be achieved by optimal mass ratio between core to shell, dwell time in the salt, size ratio between core to shell, and mass ratio between overall powder to salt, and d) the core-shell LSCF-LSM cathodes have lower polarization resistances than LSCF at higher temperatures. More work is required to optimize core-shell cathode performance at lower temperatures. However, this work thus provided justification for using the molten salt synthesis for SOFC cathodes and provided insights into future material modifications for improved performance.

08 HYDROGEN↗

Modeling Electric Vehicle Charging Station Siting Suitability with a Focus on Equity

As adoption of electric vehicles increases, the infrastructure to charge them must keep pace. Determining where to add new charging infrastructure is a complex process subject to many factors, including electrical service availability, vehicle dwell time, the type(s) of drivers and vehicles the stations will serve, traffic levels and timing, and land ownership. In addition, advancing social equity is a current priority of federal efforts to invest in electric vehicle charging infrastructure. Conducting Multi-criteria Decision Analysis (MCDA) within Argonne’s Energy Zones Mapping Tool (EZMT) is a useful method for analyzing many of the factors that influence how suitable a location is for potentially adding new charging infrastructure, and we show how equity metrics can be included in the analysis. However, data limitations impose challenges to using MCDA to evaluate and prioritize locations. We use three examples to demonstrate how to use publicly available data and MDCA to analyze different siting objectives. Each example starts with defining a specific objective and ends with how to use the results to identify specific potential locations that could be investigated further. This analysis demonstrates how interested stakeholders can use the EZMT to run the example MCDA models defined in this study, modify them to suit their needs, or create new MCDA models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

LA100 Equity Strategies. Chapter 7: Housing Weatherization and Resilience

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and access to cooling as means to achieve more equitable resilience to heat waves during unplanned power outages. Specifically, NREL used weather, housing, and socioeconomic data to characterize LA's residential building stock. We?developed a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We then simulated and evaluated the impacts of 10 building envelope and cooling upgrades on indoor temperature - a main cause of heat-induced health risks-over a 4-day power outage during a heat wave. We examined occupant exposure to extreme heat and how heat exposure changes with each upgrade across income, tenure (renter/owner status), building type, and disadvantaged community (DAC) status. We also examined upgrade costs and utility bills. Based on the results of our analysis and community guidance, we identified building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for LA's low-income households in the event of a planned or unplanned power outage during a summer heat wave. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

building envelope↗

Depot-Based Vehicle Data for National Analysis of Medium- and Heavy-Duty Electric Vehicle Charging

Medium- and heavy-duty vehicles (MHDVs) are a major source of greenhouse gases and local criteria air pollutants. Electrifying MHDVs may reduce these harmful emissions, which disproportionately impact disadvantaged communities. Due to their relatively high per-vehicle energy needs, consistent fleet operations, and frequent colocation of multiple vehicles at depots, MHDVs may have more spatially and temporally concentrated charging demands than light-duty passenger electric vehicles. That charging concentration means their electrification may require careful advance planning and coordination to manage potential impacts to the electrical grid via charge management or infrastructure upgrades. However, MHDV duty cycles and parking schedules are highly variable across vocations of operation, and there is a shortage of nationally representative, vocationally diverse public data describing typical MHDV operations. This report summarizes the methodology - designed with national representativeness in mind - used to create a new set of data describing typical daily driving distances, dwell durations, and normalized electric vehicle depot charging load curves for MHDVs. The dataset reflects the subset of MHDV operating patterns that may originate from a consistent depot each day and rely on the same depot for charging. In addition to trucks with depot-centric vocational patterns, the data describes operations of transit buses and school buses, each with a depot-centric focus. The dataset is available to the public and suitable for national analysis. It can inform research, infrastructure planning, and policymaking regarding the electrification of MHDVs.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Vehicle Charging Demand in the Chicago Metropolitan Area through 2030

This report outlines the collaborative efforts between Argonne National Laboratory and Exelon in advancing the Agent-Based Transportation Energy Analysis Model (ATEAM). Aligning with ComEd’s beneficial electrification plan, this study developed eight scenarios to access the temporal and spatial distribution of charging load and demand stemming from the widespread adoption of battery electric vehicles (BEV) adoption, augmented public charging infrastructure deployment, and increased multi-unit dwelling (MUD) charging availability. Enhancements to the ATEAM model encompassed the simulation of multiple days of travel behavior, estimation of total public charging infrastructure needs, user interface refinements, and output tracking at both vehicle and charging station levels. The total electricity consumption for residential and public charging to support over 800,000 BEVs in Chicago in 2029 is projected at approximately 10.2 GWh. Enhanced MUD home charging accessibility (70%) amplifies the home charging load in the study area by 1.5% compared to the baseline scenario (10%). The widespread adoption of BEVs reduces peak charging loads, owing to their inclusion across households with diverse income levels, thus fostering a more dispersed charging activity pattern. However, widespread BEV adoption increases the peak home charging load in areas with lower median household incomes, reflecting a higher BEV concentration in these locales and, subsequently, heightened peak charging demands. In the Widespread BEV adoption scenario, fewer census tracts exhibit elevated peak loads for combined home and public charging, indicating a more even distribution of charging demand across the study area. Predominantly, peak loads for combined charging—both home and public— occur between 2 p.m. and 10 p.m. across all scenarios, encompassing the majority of census tracts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Medium- and Heavy-Duty Vehicle Charging Infrastructure Attributes and Development

Although more established for light-duty vehicles (LDVs), advancements in electric vehicle (EV) charging technology are being made in the medium- and heavy-duty (MD/HD) sector. Progress is also being made with the electrification of MD/HD vehicles, including transit buses, school buses, MD trucks, and HD trucks. The diverse set of operational requirements and duty cycles for each vocation, as well as the range in the size of fleets, present unique charging and infrastructure requirements. This report focuses on charging requirements for MD/HD vehicles and synergies with LDV infrastructure. This analysis leans toward the qualitative rather than quantitative because relevant model inputs are in development and will not be established for a few years, as EV deployments are more mature in the LDV sectors than MD/HD. The report begins with an overview of MD/HD vehicle classes and types of charging, including depot and residential charging, among others (Section 2). Section 3 analyzes the home bases (overnight dwell locations) of existing MD/HD vehicles, with an emphasis on depot and residential home bases, and discusses implications for charging infrastructure. Section 4 discusses the key characteristics for determining if, when, and where MD/HD vehicles can leverage LDV charging infrastructure rather than requiring dedicated chargers. These considerations include electricity demand, connectors, physical space requirements, payment considerations, and impacts on the grid. Section 5 summarizes shared characteristics for MD/HD vehicles that are appropriate for near-term electrification and includes a summary of the outlook of the electric MD/HD vehicle market. The conclusion (Section 6) summarizes the report's findings and outlines areas for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗