Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric driving range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ion and Electron Acoustic Bursts during Anti-Parallel Reconnection Driven by Lasers

Magnetic reconnection converts magnetic energy into thermal and kinetic energy in plasma. Among the numerous candidate mechanisms, ion acoustic instabilities driven by the relative drift between ions and electrons (or equivalently, electric current) have been suggested to play a critical role in dissipating magnetic energy in collisionless plasmas. However, their existence and effectiveness during reconnection have not been well understood due to ion Landau damping and difficulties in resolving the Debye length scale in the laboratory. We report a sudden onset of ion acoustic bursts measured by collective Thomson scattering in the exhaust of anti-parallel magnetically driven reconnection using high-power lasers. The ion acoustic bursts are followed by electron acoustic bursts with electron heating and bulk acceleration. We reproduce these observations with one- and two-dimensional particle-in-cell simulations in which an electron outflow jet drives ion acoustic instabilities, forming double layers. These layers induce electron two-stream instabilities that generate electron acoustic bursts and energize electrons. Our results demonstrate the importance of ion and electron acoustic dynamics during reconnection when ion Landau damping is ineffective, a condition applicable to a range of astrophysical plasmas including near-Earth space, stellar flares and black hole accretion engines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Business Models for Scaling Demand Flexibility Volume I – Value proposition characteristics, challenges, and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on demand flexibility value propositions, which provide information on value creation and describe how programs deliver clear benefits that address customer and grid needs. This report discusses the role of value propositions in demand flexibility programs, provides an overview of value propositions for a range of demand flexibility stakeholders, identifies existing challenges to establishing an effective value proposition, and describes lessons learned. This report is part of a series that includes reports on customer relationship management strategies, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First-order structural phase transition at low temperature in GaPt 5 P and its rapid enhancement with pressure

Single crystals of X Pt 5 ⁢P (X = Al, Ga, and In), belonging to the 1-5-1 family of compounds, were grown from a Pt-P solution at high temperatures, and measurements of the ambient pressure, temperature-dependent magnetization, resistivity, and x-ray diffraction were made. Additionally, the ambient-pressure Hall resistivity and temperature-dependent resistance under pressure were measured on GaPt 5 ⁢P. All three compounds have a tetragonal P4/mmm crystal structure at room temperature with metallic transport and weak diamagnetism over the 2–300 K temperature range. Surprisingly, at ambient pressure, both the transport and magnetization measurements on GaPt 5 ⁢P show a steplike feature in the 70–90 K region, suggesting a possible structural phase transition. Neither AlPt 5 ⁢P nor InPt 5 ⁢P have any signatures of a phase transition in their temperature-dependent electrical resistance and magnetization data. Both the hysteretic nature and sharpness of the features in the GaPt 5 ⁢P data suggest that the transition is first-order. Further, single-crystal x-ray diffraction measurements provided further details of the structural transition with a possibility of a crystal symmetry different from P⁢4/mmm below the transition temperature. The transition is characterized by anisotropic changes in the lattice parameters and a volume collapse with respect to the high-temperature tetragonal crystal structure. Furthermore, satellite peaks are observed at two distinct and nonequivalent wave vectors (0, 0, 0.5) and (0.5, 0.5, 0.5), and density functional theory calculations present phonon softening, especially at (0.5, 0.5, 0.5), as a possible driving mechanism. Additionally, we find that the structural transition temperature increases rapidly with increasing pressure, reaching room temperature by ~2.2 GPa, highlighting the high degree of pressure sensitivity of GaPt 5 ⁢P and fragile nature of its room-temperature structure. Even though the volume collapse and extreme pressure sensitivity suggest chemical pressure should drive a similar structural change in AlPt 5⁢ P, where both unit-cell dimensions and volume are smaller, its structure is found to be the same as that of the room-temperature GaPt 5 ⁢P. Overall, GaPt 5 ⁢P stands out as a sole member of the 1-5-1 family of compounds for which a temperature-driven structural change has been observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review on the growth, properties and applications of self-assembled oxide–metal vertically aligned nanocomposite thin films—current and future perspectives

Self-assembled oxide–metal nanocomposite thin films have aroused great research interest owing to their wide range of functionalities, including metamaterials with plasmonic and hyperbolic optical properties, and ferromagnetic, ferroelectric and multiferroic behaviors. Oxide–metal nanocomposites typically self-assemble as metal particles in an oxide matrix or as a vertically aligned nanocomposite (VAN) with metal nanopillars embedded in an oxide matrix. Among them, the VAN architecture is particularly interesting due to the vertical strain control and highly anisotropic structure, enabling the epitaxial growth of materials with large lattice mismatch. In this review, the driving forces behind the formation of self-assembled oxide–metal VAN structures are discussed. Specifically, an updated in-plane strain compensation model based on the areal strain compensation concept has been proposed in this review, inspired by the prior linear strain compensation model. It provides a guideline for material selection for designing VAN systems, especially those involving complex orientation matching relationships. Based on the model, several case studies are discussed, comparing the microstructure and morphology of different oxide–metal nanocomposites by varying the oxide phase. Specific examples highlighting the coupling between the electrical, magnetic and optical properties are also discussed in the context of oxide–metal nanocomposites. Finally, future research directions and needs are also discussed.

36 MATERIALS SCIENCE↗

A Hybrid Heavy-Duty Diesel Power System for Off-Road Applications - Concept Definition

A multi-year Power System R&D project was initiated with the objective of developing an off-road hybrid heavy-duty concept diesel engine with front end accessory drive-integrated energy storage. This off-road hybrid engine system is expected to deliver 15-20% reduction in fuel consumption over current Tier 4 Final-based diesel engines and consists of a downsized heavy-duty diesel engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy recovery through both mechanical (high speed flywheel) and electrical systems. The first year of this project focused on the definition of the hybrid elements using extensive dynamic system simulation over transient work cycles, with hybrid supervisory controls development focusing on energy recovery and transient load assist, in Caterpillar’s DYNASTY™ software environment. Three key off-road applications were the focus of the hybrid concept definition with an aim of understanding the system’s modular capability for the diverse off-road heavy-duty market. Core engine performance 1D and 3D simulations isolated the efficiency contributions from the downsized engine, turbocompounding, and in-cylinder thermal barrier coatings. A fuel consumption improvement range of 14 to 24% was predicted, resulting in successful project progression to the design and experimental validation phase. Furthermore, an overview of the experimental engine and hybrid system status concludes the discussion along with the multi-year project’s next steps.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamic magnetic phase transition induced by parametric magnon pumping

Uncovering pathways to optically drive magnetic order-disorder transitions on ultrashort timescales can lead to the realization of novel out-of-equilibrium quantum phenomena. A long-sought pathway is to directly excite a highly nonthermal energy-momentum distribution of magnons, bypassing both charge and lattice degrees of freedom. However, this remains elusive owing to the weak coupling and large momentum mismatch between photons and magnons. Here we demonstrate strong parametric excitation of magnons across the entire Brillouin zone of the antiferromagnetic insulator Sr 2 ⁢Cu 3 ⁢O 4 ⁢Cl 2 by periodically modulating the superexchange interaction with the electric field of light. The excitation efficiency is greatly enhanced by tuning to the van Hove singularity in the magnon spectrum, sufficient to transiently collapse the antiferromagnetic state using a pulsed laser field of 10 9 V/m. The order parameter recovery timescale increases by over 1000 times as a function of excitation density, reflecting a crossover from high- to low-energy magnon dominated decay dynamics. This electric-field induced parametric magnon pumping mechanism is applicable to a broad range of magnetic insulators and opens up the possibility of dynamically engineering magnon distributions by design.

antiferromagnetism↗

NdFeB Permanent Magnet Uses, Projected Growth Rates and Nd Plus Dy Demands across End-Use Sectors through 2050: A Review

Rare earth element (REE) permanent magnets (NdFeB) are a critical element in a vast and growing number of industrial applications. In consumer electronics, a broad category encompassing computer, CD, and DVD hard drives, in addition to the ubiquitous cell phones, the nominal NdFeB magnet content may be small, but the global market share for this sector accounts for almost 30% of NdFeB demand, due to a large and continually increasing consumer base. It is estimated that wind turbines that primarily employ permanent magnets will add roughly 110 GW annually of on- and off-shore capability over the next few years. Electric vehicles (EVs) and E-bicycles (EBs) equipped with permanent magnet motors comprise the transportation contribution. Permanent magnet motors have garnered nearly 100% of the market share among EV manufacturers worldwide. Industrial, professional service, and personal robots, most using permanent magnets, are also included in the projected global need for rare earths, particularly Nd and Dy. The sector projects significant growth of approximately 10% across robotic categories. In this paper, we calculate the future demand for Nd and Dy through 2050 across these sectors using a compounded annual growth rate coupled with magnet weight and rare earth content. Uncertainties in the estimates, such as the true global production of Nd, a range of end-product scales and/or unit types in each sector, varied magnet compositions, and the variety of uses within a sector, are all considered.

Geochemistry & Geophysics↗

Effects of growth rate and dynamic substrate tilt on properties of Au-Ta alloy films deposited by high-power impulse magnetron sputtering

Gold-tantalum (Au—Ta) alloys are promising for next-generation hohlraums for magnetically-assisted indirect-drive inertial confinement fusion. Hohlraum fabrication involves sputter deposition of ultrathick coatings on sphero-cylindrical substrates. The control of physical properties of such coatings remains a challenge. Here, in this work, we systematically study effects of the growth rate and dynamic substrate tilt on properties of AuTa 4 films deposited onto rotating planar substrates mounted at different tilt angles to mimic different regions of the sphero-cylindrical surface of a hohlraum. We use high-power impulse magnetron sputtering (HiPIMS) in the constant charge per pulse mode with a pulse duration of 100 μs, a charge per pulse of 190 μC, a peak target current of about 3 A, and the pulse frequency varied in the range of 400–1400 Hz. The Langmuir probe, mass-resolved ion energy spectrometry, and optical emission spectroscopy are used to monitor plasma discharge characteristics in order to isolate and study effects of the growth rate. The deposition rate and the ballistics and energetics of depositing species are estimated by Monte Carlo simulations. Results show that the film microstructure, crystallographic phase, residual stress, and electrical resistivity strongly depend on both the deposition rate and substrate tilt, highlighting their critical role in tailoring properties of Au—Ta films during hohlraum fabrication.

36 MATERIALS SCIENCE↗

Design and operational considerations of catalytic membrane reactors for ammonia synthesis

Production of ammonia using hydrogen derived from renewable electricity instead of hydrocarbon reforming would dramatically reduce the carbon footprint of this commodity chemical. Novel technologies such as catalytic membrane reactors may potentially be more compatible with distributed ammonia production than the conventional Haber-Bosch process. Here, a reactor model is developed based on integrating a standard industrial iron catalyst into a catalytic membrane reactor (CMR) equipped with an inorganic membrane that is selective to NH 3 over N 2 /H 2 . CMR performance is studied as functions of wide ranges of membrane properties and operating conditions. Conversion and ammonia recovery are dictated principally by the ammonia permeance, and the benefits by using membranes become significant above 100 GPU = 3.4 × 10 –8 mol m –2 s –1 Pa –1 . To be effective, the CMR requires a minimum selectivity for ammonia of 10 over both nitrogen and hydrogen, and purity scales with the effective selectivity. Increasing the pressure of operation significantly improves all metrics, and at P = 30 bar with a quality membrane ammonia is almost completely recovered, enabling direct recycle of un-reacted hydrogen and nitrogen without need for recompression. Temperature drives conversion and scales monotonically without thermodynamic limitations in a CMR. Alternatively, the temperature may be reduced as low as 300°C while achieving conversion levels surpassing equilibrium limits at T = 400°C in a conventional reactor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Cost Analysis and Operational Range Prediction Based on Medium- and Heavy-Duty Electric Vehicle Real-World Deployments across the United States

While the market for medium- and heavy-duty battery-electric vehicles (MHD EVs) is still nascent, a growing number of these vehicles are being deployed across the U.S. This study used over 2.3 million miles of operational data from multiple types of MHD EVs across various regions and operating conditions to address knowledge gaps in total cost of ownership and operational range. First, real-world energy cost savings were determined: MHD fleets should experience energy cost savings each year from 2021 to 2035, regardless of vehicle platform, with the greatest savings seen in transit buses (up to USD 4459 annually) and HD trucks (up to USD 3284 annually). Second, to help fleets across various geographies throughout the U.S. assess the suitability of EVs for their year-round operating needs, operational range was modeled using the XGBoost algorithm (R2: 70%) given 22 input features relevant to vehicle efficiency. Finally, this paper recommends (1) that MHD fleets apply energy-saving practices to minimize the impacts of cold temperatures and high congestion levels on vehicle efficiency and range, and (2) that local hauling fleets select trucks with a nominal range nearly double the expected maximum daily range to account for range losses under local, urban driving conditions.

Qiu, Yin (ORCID:0009000900948794)↗

Characterizing W sources in the all-W wall, all-RF WEST tokamak environment

In this work, experimental data, together with interpretive modeling tools, are examined to study trends in the tungsten (W) source in the all-W environment of the WEST tokamak, both from the divertor and from the main chamber. In particular, a poloidal limiter protecting an ion cyclotron resonance heating (ICRH) antenna is used as proxy for main chamber sourcing. The key study is carried out by stepping up lower hybrid current drive (LHCD) power, as the only auxiliary power source. Limiter and divertor W sources exhibit a qualitatively similar proportionality to the total power crossing the separatrix, P SEP , although the main chamber source remains substantially lower than the divertor source, for the range of P SEP accessible in the experiments. Intepretive modeling of the limiter source is carried out with a particle-in-cell (PIC) sheath model coupled to a surface sputtering model. Oxygen is used as a proxy for all light impurity species allowing for characterization of the critical W erosion regions. To get a good quantitative match to the data, it is necessary to assume that the oxygen arrives at the surface mostly at high ionization stages (4+ and above). A separate simulation with SOLEDGE-EIRENE, constrained to measured upstream scrape-off-layer plasma profiles, gives oxygen fractional abundances that are compatible with the PIC simulation result. This is understood to arise from transport processes that dominate over recombination. Substituting the LHCD by ICRH, in an equivalent experiment, the local W source exhibits a 3× enhancement. This can be matched by the simulation, by assuming local RF electric field rectification, based on ~100 eV peak-to-peak, near-antennna electric field. This work has highlighted the particular importance of understanding the ion charge state balance of light impurities as these are most likely the dominant sputtering species in fusion devices with high-Z walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of heterogeneous, irreversible lithium plating in extreme fast charging of lithium-ion batteries

Realization of extreme fast charging (XFC, ≤15 minutes) of lithium-ion batteries is imperative for the widespread adoption of electric vehicles. However, dramatic capacity fading is associated with XFC, limiting its implementation. To quantitatively elucidate the effects of irreversible lithium plating and other degradation mechanisms on the cell capacity, it is important to understand the links between lithium plating and cell degradation at both the local and global (over the full cell) scales. Here, we study the nature of local lithium plating after hundreds of XFC cycles (charging C-rates ranging from 4C to 9C) in industrially-relevant pouch cells using spatially resolved X-ray diffraction. Our results reveal a spatial correlation at the mm scale between irreversible lithium plating on the anode, inactive lithiated graphite phases, and local state-of-charge of the cathode. In regions of plated lithium, additional lithium is locally and irreversibly trapped as lithiated graphite, contributing to the loss of lithium inventory (LLI) and to a local loss of active anode material. The total LLI in the cell from irreversibly plated lithium is linearly correlated to the capacity loss in the batteries after XFC cycling, with a non-zero offset originating from other parasitic side reactions. Finally, at the global (cell) scale, LLI drives the capacity fade, rather than electrode degradation. We anticipate that the understanding of lithium plating and other degradation mechanisms during XFC gained in this work will help lead to new approaches towards designing high-rate batteries in which irreversible lithium plating is minimized.

25 ENERGY STORAGE↗

Development of a Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) Tool

As demand for consumer electric vehicles (EVs) has drastically increased in recent years, manufacturers have been working to bring heavy-duty EVs to market to compete with Class 6-8 diesel-powered trucks. Many high-profile companies have committed to begin electrifying their fleet operations, but have yet to implement EVs at scale due to their limited range, long charging times, sparse charging infrastructure, and lack of data from in-use operation. Thus far, EVs have been disproportionately implemented by larger fleets with more resources. To aid fleet operators, it is imperative to develop tools to evaluate the electrification potential of heavy-duty fleets. However, commercially available tools, designed mostly for light-duty vehicles, are inadequate for making electrification recommendations tailored to a fleet of heavy-duty vehicles. The main challenge is that light-duty tools do not estimate real-time vehicle mass, a factor that has a disproportionate impact on the energy consumption of large commercial vehicles. The Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) tool advances the state of the art in evaluating electrification potential and infrastructure requirements for fleets of commercial vehicles. In this work, the HEVII tool is demonstrated with non-uniformly sampled telematics data from an existing fleet to assess the suitability for electrification of each individual vehicle, determine optimal locations for charging infrastructure to support a fleet of EVs and analyze associated costs. Payload mass is predicted using sparse ground-truth data for all input drive cycles and an initial data analysis is conducted to assess the characteristics driving behaviors and energy consumption of the fleet using an adaptable vehicle model. Battery size requirements are determined by applying a novel charger placement algorithm to maximize routes that are viable for EVs and balance time delays with infrastructure development costs. This work details and demonstrates the different aspects of the HEVII tool, presenting preliminary results from an example use case.

ADVANCED PROPULSION SYSTEMS↗

Kinetic simulation of a 50 mTorr capacitively coupled argon discharge over a range of frequencies and comparison to experiments

The effect of driving frequency in the range of 13.56–73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct “temperatures” for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2–10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25% of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model, and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge Separation at Organic Interfaces with Near-Zero Energy Offset: A Step toward Designing Inorganic-like Organic Semiconductors

For organic semiconductors, it is often presumed that an energy level offset at the donor–acceptor (D-A) interface is required to provide the driving force for charge separation (CS). This energy level offset unavoidably leads to a voltage loss in organic photovoltaics. In this work, by using zinc phthalocyanine (ZnPc) and fluorinated zinc phthalocyanine (F 4 ZnPc) as a model D/A interface, we found that spontaneous CS, with an enthalpy increase of ∼0.3–0.4 eV, can occur even with an interfacial energy offset as small as ∼0.1 eV. This enthalpy-increase CS process is driven by entropy. The entropic driving force can be enhanced by two factors: (1) a point-like spatial contact between the delocalized electron and hole wave function in the charge transfer exciton; (2) a small band bending near the interface originating from long-range electrostatic interaction. Our work demonstrates that effective CS can occur at interfaces with a near-zero energy level offset, which means that the energy loss at the D/A interface can be avoided.

36 MATERIALS SCIENCE↗

Overview of the TCV tokamak program: Scientific progress and facility upgrades

The TCV tokamak is augmenting its unique historical capabilities (strong shaping, strong electron heating) with ion heating, additional electron heating compatible with high densities, and variable divertor geometry, in a multifaceted upgrade program designed to broaden its operational range without sacrificing its fundamental flexibility. The TCV program is rooted in a three-pronged approach aimed at ITER support, explorations towards DEMO, and fundamental research. A 1 MW, tangential neutral beam injector (NBI) was recently installed and promptly extended the TCV parameter range, with record ion temperatures and toroidal rotation velocities and measurable neutral-beam current drive. ITER-relevant scenario development has received particular attention, with strategies aimed at maximizing performance through optimized discharge trajectories to avoid MHD instabilities, such as peeling-ballooning and neoclassical tearing modes. Experiments on exhaust physics have focused particularly on detachment, a necessary step to a DEMO reactor, in a comprehensive set of conventional and advanced divertor concepts. The specific theoretical prediction of an enhanced radiation region between the two X-points in the low-field-side snowflake-minus configuration was experimentally confirmed. Fundamental investigations of the power decay length in the scrape-off layer (SOL) are progressing rapidly, again in widely varying configurations and in both D and He plasmas; in particular, the double decay length in L-mode limited plasmas was found to be replaced by a single length at high SOL resistivity. Experiments on disruption mitigation by massive gas injection and electron-cyclotron resonance heating (ECRH) have begun in earnest, in parallel with studies of runaway electron generation and control, in both stable and disruptive conditions; a quiescent runaway beam carrying the entire electrical current appears to develop in some cases. Developments in plasma control have benefited from progress in individual controller design and have evolved steadily towards controller integration, mostly within an environment supervised by a tokamak profile control simulator. TCV has demonstrated effective wall conditioning with ECRH in He in support of the preparations for JT-60SA operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗