Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric field pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

ELF wave production by an electron beam emitting rocket system and its suppression on auroral field lines - Evidence for Alfven and drift waves

Orthogonal probes on a free-flying plasma diagnostics payload are used to study ELF electric disturbances in the auroral ionosphere that are due to the injection of powerful electron beams. Frequency spectrograms are presented for various pitch angles, pulsing characteristics, and other properties of the injected beams; the large scale DC ionospheric convection electric field is measured, together with auroral particle precipitation, visual auroral forms, and ionospheric parameters. In view of the experimental results obtained, it is postulated that the observed ELF waves are in the Alfven and drift modes, and are generated by the positive vehicle potential during beam injection.

Winckler, J. R.↗

Broadband electromagnetic sensors for aircraft lightning research

A set of electromagnetic sensors, or electrically-small antennas, is described. The sensors are designed for installation on an F-106 research aircraft for the measurement of electric and magnetic fields and currents during a lightning strike. The electric and magnetic field sensors mount on the aircraft skin. The current sensor mounts between the nose boom and the fuselage. The sensors are all on the order of 10 cm in size and should produce up to about 100 V for the estimated lightning fields. The basic designs are the same as those developed for nuclear electromagnetic pulse studies. The most important electrical parameters of the sensors are the sensitivity, or equivalent area, and the bandwidth (or rise time). Calibration of sensors with simple geometries is reliably accomplished by a geometric analysis; all the sensors discussed possess geometries for which the sensitivities have been calculated. For the calibration of sensors with more complex geometries and for general testing of all sensors, two transmission lines were constructed to transmit known pulsed fields and currents over the sensors.

Trost, T. F.↗

Electron Spin Polarization in Large Electric Fields

This project investigated the effects of large electric fields on electron spin polarization in semiconductors, which is of interest for spin-based electronics (“spintronics”) and quantum information processing. It has been theoretically proposed that large electric fields could potentially preserve or amplify electron spin polarization, which would make it easier to generate, transport, and detect spin polarization in spin-based devices; however, previous measurements had not measured the response of electron spin polarization at large electric fields. During this project, methods to perform measurements of electron spin polarization at large electric fields were developed and performed using ultrafast time- and spatially-resolved magneto-optical spectroscopy, high-voltage pulses, and lock-in detection. The device geometry was engineered to reduce the threshold voltage required to reach the Gunn threshold, and the effect of optical illumination on the sample conductivity and Gunn oscillations was investigated. Electron spin polarization measurements were performed at electric fields up to and beyond the Gunn threshold for the device. The measurements showed that the electron spin polarization magnitude decreased with increasing electric field in the devices measured, and a spin amplification effect was not observed. However, these effects could potentially exist in a different material or in a material with a different doping concentration or in a different device geometry.

36 MATERIALS SCIENCE↗

Characteristics of upward-connecting-leader current leading to attachment in downward negative cloud-to-ground lightning strokes

For this work, we analyzed currents associated with upward connecting leaders (UCLs) initiated from the Kennedy Space Center Industrial Area Tower in two negative cloud-to-ground strokes that struck the tower. One stroke was also recorded using a high-speed video camera located 760 m from the KSC IAT. The NLDN-reported peak currents for the two strokes were – 31.7 and – 98.5 kA. During the UCL development phase the current waveforms exhibited a monotonically (quasi-exponentially) increasing “background” current overlaid with 10-μs scale pulses with a median amplitude of 51.1 A. The UCL current durations for the two strokes were 1039 and 449 μs, respectively. During the pre-attachment processes (UCL and slow front) the total negative charge effectively transferred to ground were 70.2 and 55 mC, respectively. For the stroke captured on high-speed video, the average line-charge-density for the 109-m long UCL was found to be 0.5 mC/m. The average UCL 2-D speed was 2.4 × 10 5 m/s, and it was observed to accelerate toward the downward leader prior to attachment. We observed that UCL-pulse amplitudes are larger, background currents are higher, and interpulse intervals are shorter at later times during UCLs, which can be attributed to the intensification of the local electric field due to the approaching downward negative leader. The median positive charge injected into the UCL by a pulse was 297 μC. The UCL associated with the higher peak-current stroke produced the highest injected pulse-charge values about three times sooner during its development, likely due to the 2–2.7 times faster average downward leader vertical speeds.

54 ENVIRONMENTAL SCIENCES↗

Pump-probe spectroscopy of chiral vibrational dynamics

A planar molecule may become chiral upon excitation of an out-of-plane vibration, changing its handedness during half a vibrational period. When exciting such a vibration in an ensemble of randomly oriented molecules with an infrared laser, half of the molecules will undergo the vibration phase-shifted by π compared to the other half, and no net chiral signal is observed. This symmetry can be broken by exciting the vibrational motion with a Raman transition in the presence of a static electric field. Subsequent ionization of the vibrating molecules by an extreme ultraviolet pulse probes the time-dependent net handedness via the photoelectron circular dichroism. Our proposal for pump-probe spectroscopy of molecular chirality, based on quantum-chemical theory and discussed for the example of the carbonyl chlorofluoride molecule, is feasible with current experimental technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

The temporal structure of HF and VHF radiations during Florida lightning return strokes

Measurements have been made of the HF and VHF radiation at 3, 30, 139, and 295 MHz produced during lightning return strokes, in correlation with wideband electric field measurements covering from about 300 Hz to 2 MHz. Intense pulses of RF are observed during the first return stroke in a discharge to ground, but with a 10-30 µsec time delay between the beginning of the stroke and the occurrence of significant RF radiation. The delay occurs at all frequencies and is short enough to suggest that the main channel and/or branches are the main initial sources of RF during the first stroke. During a subsequent return stroke, the RF starts an average of 265 µsec prior to the onset of the stroke. At 139 and 295 MHz, the subsequent stroke RF lasts only about 115 µsec; however, at 3 MHz, the radiation frequently persists up to and during the stroke.

David M Le Vine↗

Measurement of the ionization response of amorphous selenium with 122 keV γ rays

In this work, we performed a measurement of the ionization response of 200 μm-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/μm. The aSe target was exposed to ionizing radiation from a 57 Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV γ rays, we measured the charge yield in aSe and the line width as a function of drift electric field. From a detailed microphysics simulation of charge generation and recombination in aSe, we conclude that the strong dependence of recombination on the ionization track density provides the dominant contribution to the energy resolution in aSe. These results provide valuable input to estimate the sensitivity of a proposed next-generation search for the neutrinoless ββ decay of 82 Se that aims to employ imaging sensors with an active layer of aSe. We estimate the RMS line width of the integrated ionization signal from neutrinoless ββ decay events (of deposited energy 3 MeV) to be 2.0% for a drift field of 50 V/μm. The energy resolution can be improved to 1% by correcting for the charge yield as a function of ionization density along the imaged electron tracks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Increasing the isotropic properties of a discharge spark chamber with a large gap

The recording of particle tracks in the form of sparks or streamers running at different angles toward the electric field of the chamber was studied. The investigations were performed with two discharge spark chambers consisting of boxes filled with neon at 1 atm. The spark chambers were powered by a pulse with an amplitude of 300 kV applied from a pulse generator. The recording of particle tracks in the form of sparks took place at track angles smaller than 30 deg with respect to the electrical field. At angle larger than 40 deg the tracks are recorded in the form of streamers. Particle traces with respect to the angle are given.

Nurgozhin, N. N.↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Axial proton probing of magnetic and electric fields inside laser-driven coils

In a laser-driven coil, a laser is used to eject electrons from a plate, which then draws a current through a loop. Diagnosing the field strength, geometry, and conditions within these loops has been one of the primary difficulties in fielding this type of target. In this paper, the diagnostic technique of axial proton probing with a mesh fiducial of a laser-driven coil is demonstrated. Multiple coil types were driven by a 1 ns, 1.25 kJ long pulse beam and probed several times. Here, this technique provides significantly more information than transverse probing on electric- and magnetic-field strength in the region of interest and shows in our experiment complex, non-uniform current path structures and charge distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical solver for investigating the space charge effect on the electric field in liquid argon time projection chambers

This paper reports the development of a numerical solver aimed to simulate the interaction between the space charge (i.e. ions) distribution and the electric field in liquid argon time projection chamber (LArTPC) detectors. The ion transport equation is solved by a time-accurate, cell-centered finite volume method and the electric potential equation by a continuous finite element method. The electric potential equation updates the electric field which provides the drift velocity to the ion transport equation. The ion transport equation updates the space charge density distribution which appears as the source term in the electric potential equation. The interaction between the space charge distribution and the electric field is numerically simulated within each physical time step. The convective velocity in the ion transport equation can include the background flow velocity in addition to the electric drift velocity. The numerical solver has been parallelized using the Message Passing Interface (MPI) library. Numerical tests show and verify the capability and accuracy of the current numerical solver. It is planned that the developed numerical solver, together with a Computational Fluid Dynamics (CFD) package which provides the flow velocity field, can be used to investigate the space charge effect on the electric field in large-scale particle detectors.

42 ENGINEERING↗

On the use of dielectric elements in axion searches with microwave resonant cavities

This study explores the primary effects of dielectric materials in a resonant cavity-based search for axion dark matter. While dielectrics prove beneficial in numerous cases, their incorporation may lead to less-than-optimal performance, especially for the lowest TM mode. Additionally, the stronger confinement of the electric field inside the dielectrics can exacerbate mode mixings, in particular for higher-order modes. Case studies have been carried out using a combination of analytical solutions and numerical simulations. The findings indicate dielectric cavities employing the TM 010 mode experience a significant reduction in sensitivity when compared to a similar search conducted in a cavity at equivalent frequency using no dielectrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

D region disturbances caused by electromagnetic pulses from lightning

Attention is given to a simple formulation of the propagation and absorption in a magnetized collisional plasma of EM pulses from lightning which describes the effect of discharge orientation and radiated electric field on the structure and magnitude of heating and secondary ionization in the D region. Radiation from most lightning discharges can heat substantially, but only the most intense (not less than 20 V/m) are likely to cause ionization enhancements not less than 10 percent of the ambient in a single ionization cycle. This dependence on the radiated electric field is modified by the discharge radiation pattern: a horizontal cloud discharge tends to cause larger heating and ionizaton maxima while a vertical return stroke causes disturbances of a larger horizontal extent.

Rodriguez, Juan V.↗