Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of equilibrium radial electric field on energy loss process after pedestal collapse

An impact of the equilibrium radial electric field on energy loss processes after pedestal collapse is numerically investigated using the BOUT++ framework. Using linear stability analysis, the resistive ballooning mode is shown to be stabilized by the radial shear of the equilibrium radial electric field. On the other hand, the energy loss level after the pedestal collapse increases if the equilibrium radial electric field is taken into account. The spatio-temporal and phase diagram analyses show that the equilibrium radial electric field partially cancels the fluctuation-driven toroidally axisymmetric radial electric field and weakens the E × B shearing rate after pedestal collapse, weakening the turbulence suppression by vortex shearing. Finally, the equilibrium radial electric field therefore increases turbulence intensity in nonlinear cyclic oscillations among pressure gradient, E × B shearing rate, and turbulence intensity, which gives rise to subsequent bursts of turbulent transport and increases the energy loss level.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The value of concentrating solar power in ancillary services markets

Ancillary services, such as spinning reserves, can provide grid reliability and contribute to profitability of an energy resource. We exercise an existing dispatch optimization model to estimate the profitability of a concentrating solar power plant by incorporating the sale of spinning reserves in the ancillary service market using the National Renewable Energy Laboratory's System Advisor Model to simulate operations within a 72-h rolling horizon framework. Assuming a price-taker approach with day-ahead energy and spinning reserve prices from both the California Independent System Operator and the Electricity Reliability Council of Texas, we find that selling spinning reserves in addition to electric energy increases plant profitability by up to 7% with perfect knowledge of day-ahead pricing and solar resource availability. Here, this finding suggests that spinning reserve markets provide significant value streams to concentrating solar power plants that can leverage thermal energy storage to offer reliable production in the short-to-medium term.

14 SOLAR ENERGY↗

Aqueous organic flow batteries for sustainable energy storage

Aqueous Organic Redox Flow Batteries (RFBs) have the potential to address the large-scale need for storing electrical energy from intermittent sources like solar- and wind-based generation. Unlike metal-based redox systems, small organic molecules present the prospect of achieving sustainability, by being synthesizable from abundantly available carbon dioxide, water, nitrogen, sulfur, and renewable energy. This mini-review focuses on the progress and challenges in designing water-based RFBs based on small organic molecules that can address the requirements of large-scale energy storage. Further, much of the recent research in this area involves discovering new molecular architectures via computational screening, understanding degradation, and cell configurations to address the techno-economic challenges of extraordinary electrochemical durability, recyclability, low cost of precursor materials, and good solubility. Redox materials for the positive side of the cell are notably few. Future research must continue to focus on these techno-economic challenges through rapid materials discovery.

25 ENERGY STORAGE↗

Refining Control, Charging, and Battery Chemistry for CO 2 e Savings in Heavy-Duty Off-Road Plug-In Series Hybrid

With current and future regulations continuing to drive reductions in carbon dioxide equivalent (CO 2 e) emissions in the on-road industry, the off-road industry is also likely to be regulated for fuel and CO 2 e savings. This work focuses on converting a heavy-duty off-road material handler from a conventional diesel powertrain to a plug-in series hybrid, achieving a 49% fuel reduction and 29% CO 2 e reduction via simulation. Control strategies were refined for energy savings, including a regenerative braking strategy to increase regenerative braking and a load-following hydraulic strategy to decrease electrical energy consumption. The load-following hydraulic control shuts off the hydraulic electric machine when it is not needed—an approach not previously seen in a load-sensing, pressure-compensated system. Furthermore, these strategies achieved a 24.1% fuel savings, resulting in total savings of 61% in fuel and 41% in CO 2 e in the plug-in series compared to the conventional machine. Beyond control strategies, this study evaluated battery chemistry and charging strategy refinements for total cost of ownership (TCO) and lifetime CO 2 e. LFP batteries emerged as the most cost-effective and least emitting due to their longer lifespan, which reduced replacement frequency. Charging comparisons showed that Level 2 charging (L2C) typically resulted in lower TCO but higher lifetime CO 2 e than DC fast charging (DCFC). DCFC costs were heavily influenced by local demand charges, and DCFC emissions were heavily influenced by local grid emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Lithium-Ion UPS Battery Research and Commentary

Lithium-ion batteries are increasingly prevalent in a variety of devices both small and large. The high level of stored energy in UPS battery racks is closely scrutinized because sudden, uncontrolled release of chemical and electrical energy could be an ignition source. With this in mind, lithium-ion battery safety is the subject of several testing standards, including UL 1642, UL 1973, and UL 9540A.The motivation for this research and commentary is the potential installation of lithium-ion batteries in a Vertiv UPS assembly for one of the buildings on the ORNL campus. The battery modules Vertiv uses are compliant with abuse survival testing, demonstrating that cells and modules are rugged. The modules are further compliant with fire propagation requirements – in the event a failure does produce a fire, it doesn’t spread. Beyond these, the rack level assemblies Vertiv sources comply with UL requirements to contain a fire within the rack.This three-tiered approach to battery safety suggests Vertiv’s lithium-ion UPS battery racks can reasonably be considered for use in a facility with appropriate fire protection provisions and an informed emergency response team.

25 ENERGY STORAGE↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Application of Particle Accelerators to Mitigate Energy and Climate Change Problems Facing America

Reliable CO 2 -free baseload power is needed to address ever-increasing demands for electricity while minimizing adverse climate change. Diversified power supply provided by solar, wind, geothermal, and nuclear reactors can displace the use of fossil fuels. The United States (U.S.) is taking a new look at nuclear power as a source of electrical energy and the nuclear industry is proposing new approaches which may minimize capital costs. However, nuclear power comes with a variety of technical problems. Chief among those is managing the used fuel from nuclear reactors. No long-term, practicable solution to this problem is available. The lack of progress on a comprehensive waste management strategy restricts growth in the nuclear power industry and minimizes the role that nuclear energy may serve as part of a zero-carbon future (Bahr, 2021). According to the Nuclear Waste Policy Act of 1982, as amended, the U.S. Government has possession of the used reactor fuel and incurs large annual storage fees paid to utilities to store and safeguard the accumulated used fuel. In effect, short term on-site storage of nuclear waste is the current waste management plan. The amount of used reactor fuel in the U.S. is approximately 80,000 metric tons. While no geologic repository exists within the U.S., the potential site at Yucca Mountain, NV would accommodate 70,000 metric tons, which fails to meet current and future needs. Given the technical and political challenges associated with establishing a single geological storage site, it is necessary for the U.S. to implement technologies that improve the suitability of geological storage by reducing the volume and radiotoxicity of stored material. No extant technology meets this need. Accelerator driven waste burners have been proposed as a scalable method to process used nuclear fuel, however considerable technical challenges remain which impede commercialization. Innovations in design require investigation of novel materials, development of accurate models and simulations, and a comprehensive assessment of safety and performance. This proposal elaborates how LANL is uniquely positioned to make key contributions to this area of research.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Housing Energy Connection Project (Final Technical Report)

This project expanded existing medium-voltage distribution to 33 households, a daycare, a mechanical shop, irrigation pumps, and a sewer lift station, all of which previously received electric service from the local electric utility. As part of the project, automatic meter reading (AMR) and advanced metering infrastructure (AMI) was installed to allow the Tribe to set up its own electric metering like a utility. The primary objective of this project was to expand the Tribe-owned electrical distribution to provide highly reliable electrical service to these existing loads. The objective was successfully met after project completion. The project reduced high costs for electric energy previously supplied by the utility, by supplanting utility-supplied electric power with Tribe-generated electric power. The project gave the Tribe greater independence from traditional power sources and provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

A Review of Current Research Trends in Power-Electronic Innovations in Cyber–Physical Systems

Here, in this article, a broad overview of the current research trends in power-electronic innovations in cyber–physical systems (CPSs) is presented. The recent advances in semiconductor device technologies, control architectures, and communication methodologies have enabled researchers to develop integrated smart CPSs that can cater to the emerging requirements of smart grids, renewable energy, electric vehicles, trains, ships, the Internet of Things (IoT), and so on. The topics presented in this article include novel power-distribution architectures, protection techniques considering large renewable integration in smart grids, wireless charging in electric vehicles, simultaneous power and information transmission, multihop network-based coordination, power technologies for renewable energy and smart transformer, CPS reliability, transactive smart railway grid, and real-time simulation of shipboard power systems. It is anticipated that the research trends presented in this article will provide a timely and useful overview to the power-electronics researchers with broad applications in CPSs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced electrolytes for high temperature energy storage device

An ultracapacitor that includes an energy storage cell immersed in an electrolyte and disposed within an hermetically sealed housing, the cell electrically coupled to a positive contact and a negative contact, wherein the ultracapacitor has a gel or polymer based electrolyte and is configured to output electrical energy at temperatures between about −40° C. and about 250° C. Methods of fabrication and use are provided.

Brambilla, Nicol Michele↗

High temperature energy storage device

An ultracapacitor that includes an energy storage cell immersed in an electrolyte and disposed within an hermetically sealed housing, the cell electrically coupled to a positive contact and a negative contact, wherein the ultracapacitor is configured to output electrical energy within a temperature range between about 80 degrees Celsius to about 210 degrees Celsius. Methods of fabrication and use are provided.

Signorelli, Riccardo↗

Advanced electrolytes for high temperature energy storage device

An ultracapacitor that includes an energy storage cell immersed in an electrolyte and disposed within an hermetically sealed housing, the cell electrically coupled to a positive contact and a negative contact, wherein the ultracapacitor has a gel or polymer based electrolyte and is configured to output electrical energy at temperatures between about −40° C. and about 250° C. Methods of fabrication and use are provided.

Brambilla, Nicolò↗