Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Future grid mix impacts on whole-building life cycle assessment

Building construction and operation are a significant contribution to global greenhouse gas emissions, so understanding and mitigating emissions is crucial for reliable and realistic emissions accounting. Whole-building Life Cycle Assessment (WBLCA) is an emissions accounting method that considers lifetime environmental impacts of a building during its construction, operation, and eventual end-of-life. When performing WBLCAs, emission calculations from the building's operation over the entire building lifespan are typically based on today's energy grid mixes. This method does not consider changes or advancements in the clean energy proportion within the grid mix and can over or under-inflate results, skewing the ratio of embodied vs. operational environmental impacts. While a variety of prediction tools estimate what future grid emissions might be, predictions can vary widely. To predict the clean energy ratio within future grid mixes and the potential impact these changes might have on WBLCA, annual data from several existing U.S. grid models was averaged and probabilistic modeling was used to extend the usable projections of shorter forecasts. Results show that clean energy sources will likely continue to increase over time, although the rate of growth varies by model. On average, by 2085, the clean energy penetration of the grid is projected to reach ~81% and renewable energy is projected to reach ~71%, although no widespread consensus is reached. To understand how the future grid mix impacts lifetime building emissions within a WBLCA context, the team analyzed two 2021 IECC-compliant all-electric residential buildings: one built from traditional materials and construction processes and the other built with carbon sequestering materials and modular assembly, with a portion of energy generated on site. The results indicate that a moderate estimate of future electricity grid mixes shows a reduction of yearly operational emissions for traditional residential buildings of 55% between 2025 and 2085, and a corresponding reduction of 48% of total emissions over a 60 year building lifespan. This study offers a nuanced approach to account for the variability of future grid mix models and provides an average trend-line based on a robust collection of scenarios.

Life Cycle Assessment (LCA)↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Interpretable Machine Learning for Characterizing Electric Vehicle Charging Behavior: Insights from Real-World Data

As electric vehicle (EV) adoption rises globally, concerns about the impact on aging electrical grids grow, particularly regarding the charging behavior of EV drivers. This study analyzes real-world driving and charging data from Ford battery electric vehicles (BEVs) collected between 2018 and 2019 to develop interpretable models that characterize charging behavior and quantify influencing factors. Prior research has relied on assumptions regarding driver behavior, often overlooking actual charging patterns. By employing generalized linear mixed models (GLMMs), this work offers insights into how various elements, such as next trip distance and state of charge (SOC), influence charging decisions. The dataset comprises over three million park-trip pairs from 1,997 vehicles, revealing that features related to driving behavior significantly dictate charging behavior, while infrastructure and regional factors have lesser impacts. The findings suggest that existing simulation models may oversimplify EV charging behavior assumptions. This work utilizes real-world EV driving and charging data to train interpretable models that describe charging behavior and quantify the factors most associated with how drivers use charging infrastructure. This research underscores the need for interpretable, data-driven methodologies to inform future EV infrastructure planning and grid management.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Technoeconomic Analysis of Steel Production with Electric Thermal Energy Storage

The iron and steel industry is an important manufacturing sector and one of the largest energy consumers in the United States and globally. Hydrogen direct reduction of iron ore (H2DRI) is considered a promising process that could enhance domestic steel production. This process requires hydrogen inlet temperatures up to 950 degrees C to drive the endothermic reduction of the iron ore pellets. In this work we investigate the technoeconomic performance of an H2DRI plant using electric thermal energy storage (ETES) technologies for the hydrogen heating, compared to conventional natural gas fired heaters, hydrogen fired heaters, and electric hydrogen heaters. A technoeconomic analysis framework for the plant is developed and used in multiple case studies, covering different hydrogen prices, grid electricity profiles, and financing scenarios. The levelized cost of steel production is found out to be in the range of $775-950/mt, which is mostly inside the benchmarked steel price of $941/mt. ETES-based hydrogen heating is found to be in par with conventional natural gas fired heaters, and cheaper than hydrogen fired heaters and electric hydrogen heaters. The major cost drivers are the iron ore and hydrogen feedstock, followed by the hydrogen compression and heating capital. Several insights and suggested future directions are identified.

08 HYDROGEN↗

Bridging the Gap on Data, Metrics, and Analyses for Grid Resilience to Weather Events: Information that utilities can provide regulators, state energy offices, and other stakeholders

A growing number of states require regulated utilities to file resilience plans to improve the electric grid’s ability to anticipate, withstand, adapt to and recover from increasingly severe weather events. This report aims to help state regulators identify and request data, metrics, and analyses from utilities and use it in decisions on utility resilience plans and investments. The report reviews state requirements and utility plans focused on overall grid resilience, climate change resilience and vulnerabilities, infrastructure modernization, storm protection, and wildfire mitigation. It details types of data, metrics, and analyses across five categories--and provides examples of each from the utility plans. The first category is vulnerability assessments, or evaluations of the susceptibility of systems, communities, or assets to potential harm from identified hazards. The second is data on hazards and the exposure of utility assets and customers to these hazards. The third is attribute metrics, or system characteristics that contribute to or describe the resilience of a system. The fourth is performance metrics, which are impacts of resilience investments on system performance--typically a reduction of negative impacts from hazard events. Finally, evaluation and prioritization are analyses that utilities conduct to estimate impacts from resilience measures (evaluation) and prioritize measures based on costs and estimated impacts (prioritization). The report concludes with examples of key trends and emerging best practices for states and utilities, and identifies areas for further research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating Resilience of the Community through Holistic Engagement and use of Renewables (ARCHER) Planning Framework

The primary objective of the Accelerating Resilience of the Community through Holistic Engagement and Use of Renewables (ARCHER) initiative was to identify and incorporate the unique variations in energy burden, social vulnerability, living conditions, and access to essential services that differ across communities. By accounting for these localized factors—down to the neighborhood level—the project supports more targeted and effective investments in community resilience. The framework seeks to establish practical planning guidance, methods, and performance measures for community energy resilience, integrate community-level and electric utility system resilience planning, and assess its effectiveness through comparison with conventional and operational planning approaches. A key component of the project was its data exchange platform, which is used to evaluate and demonstrate the tools, methodologies, and planning approaches developed through ARCHER. This open-source platform enables developers and vendors of distribution and outage management systems to build upon the research by incorporating its concepts into their own tools and workflows. This capability is enabled by the transparent availability of data, functional requirements, and the underlying information model. The project yielded several important insights. First, meaningful engagement with communities is essential to achieving comprehensive resilience outcomes. Second, resilience planning is most effective when electric grid considerations and broader community needs are addressed in a coordinated manner. Third, the use of platforms that allow for real-time input from communities can enhance utility responsiveness during restoration activities. Fourth, a structured and systematic planning approach can successfully translate ARCHER concepts into practice. Fifth, the development of an integrated metric that reflects both grid performance and community impacts provides a more holistic basis for evaluating resilience. Finally, incorporating community engagement and equity considerations into grid operations is critical, particularly during severe weather events that result in extended outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TASTI-GRID: a holistic view of Florida's grid resilience opportunities

In December of 2025, the American Society of Civil Engineers updated Florida’s infrastructure grade to a ”C+” – reflecting overall investments in recent years. With the recommendation to further strengthen the electric grid and establish consistent building standards, extreme weather, aging infrastructure, and population in-migration are still compounding Florida’s grid vulnerabilities. Key challenges related to hurricane and other tropical & marine weather events are not unique to Florida. However, the state’s topography, location, demographics, and variation among rural and urban centers for tourism and industry, demonstrate the need for unique approaches to advancing critical infrastructure resilience, particularly for large concentrations of elderly residents or in areas of historic underinvestment. Florida’s grid asset advancements are credited with a reduction in average power outage durations. Yet, improvements since 2021 have set the stage for future resilience activities – as modernization efforts have greatly improved data collection – enabling better understanding of vulnerabilities and trends across counties and localities (particularly in Central Florida).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Survey of Open-Source Tools for Transmission and Distribution Systems Research

This work presents a review of open-source electric power transmission and distribution systems analysis tools suitable for use by industry professionals and academic researchers. Due to the high complexity of the electric grid, there exist numerous tools and extensive research pertaining to nearly every aspect of the design, operation, and control of transmission and distribution networks. In addition to the commercial tools, a wide range of free, open-source tools, models, and data usable by the scientific community for related research have been developed by different organizations, including both international and US universities and national laboratories. However, due to the absence of a catalog of available tools, models and data, researchers often lack a knowledge of existing capabilities and may develop duplicative software and tools. Increasing awareness of these available resources seeks to accelerate their broader use, leading to more efficient and standardized grid analysis. This review paper (which is part of a larger survey effort that studied over 400 tools in the transmission, distribution, buildings, and electric vehicles space) outlines selected open-source resources that have been developed in power transmission and distribution systems research. It is anticipated that this work can serve as a guide for industry and academic researchers alike, ensuring that research efforts are well-channeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Grid Value of Ocean Current Energy in Florida

Ocean current energy technology has been proposed as a potential contributor to Florida's energy portfolio. There has been limited investigation of how this energy would be valued when integrated into the Florida electrical grid. This study assesses three future grid scenarios to evaluate the impact of adding zero-cost ocean current energy to each. The Resource Planning Model, a tool developed by the National Renewable Energy Laboratory, is used to identify the least-cost generation mix through 2050, with and without ocean current energy. The first scenario is a base case and assumes existing policies in which the addition of ocean current energy does not retire fossil-based technologies but variable generation technologies. In the second scenario, solar and storage technologies are lower cost, and the addition of ocean current generation enables those technologies along with wind to retire existing natural gas units earlier. In the third scenario, which requires a 95% reduction in carbon emissions from 2020 levels by 2050, ocean current energy can play a role in decarbonization along with other variable generation technologies. This analysis is intended to inform stakeholders on the opportunity, potential challenges, and overall value to the grid of ocean current technology from a reliability and availability focused perspective.

capacity expansion model↗

The Grid Value of Ocean Current Energy in Florida: Preprint

Ocean current technology has been proposed as a potential contributor to Florida's energy portfolio. There has been limited investigation of how this energy would be valued when integrated into the Florida electrical grid. This study assesses three future grid scenarios to evaluate the impact of adding ocean current to each. NREL's capacity expansion model, Resource Planning Model, is used to identify the least-cost generation mix through 2050, with and without ocean current. The first scenario, Business as Usual, Base case assuming current policies, ocean current does not replace fossil-based technologies. In the second scenario, we allow solar and storage to have lower costs than the first scenario which allows ocean current to retire gas earlier and more variable generation technologies to be deployed. In the third scenario, the Florida carbon constraint 95 by 2050 from 2020 levels case, ocean current can play a bigger role in decarbonization than the two other cases when coupled with other technologies.

capacity expansion model↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗