Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Tailoring olefin distribution via tuning rare earth metals in bifunctional Cu-RE/beta-zeolite catalysts for ethanol upgrading

Bioethanol to middle distillate technologies have offered a unique solution to produce renewable aviation fuel for decarbonizing the hard-to-electrify sectors. Here, we have developed the series of bimetallic Cu- and rare earth-containing (RE) Beta zeolite catalysts that yield high C 3+ alkene selectivity from ethanol upgrading (>80% selectivity at ~100% conversion, 623 K). The formation rates of butene isomers to C 5+ alkenes are linearly correlated with the strength of Lewis acidic RE identity, which follows the sequence of Yb 12 /Beta >Y 7 /Beta > Gd 12 /Beta > Ce 10 /Beta > La 12 /Beta. Rate measurements indicate that the RE selection plays the vital role in altering the rate of the key competitive reactions within the ethanol-to-alkenes reaction network, namely C 4 alcohol dehydration and C-C chain growth, which dictate alkene product distributions. Finally, these findings indicate a feasible and promising method for tailoring alkene product distributions from ethanol upgrading, which is of notable significance to the generation of renewable middle distillates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmarking thermal energy storage cost for industrial process heat

Process heat accounts for roughly half of industrial energy demand, and currently 95% of process heat is derived from the combustion of natural gas, oil, and coal. Electrification of industrial heating could be an alternative, potentially expanding locations suitable for manufacturing; however, industrial facility owners may desire energy storage to stabilize energy costs. In this work, the economic benefits of pairing thermal storage with electrified process heat to reduce the average price paid for energy are analyzed. Cost savings focus on energy arbitrage, or leveraging flexible energy pricing schemes, alone. The cost of natural gas combustion across decades (2019-2060) is compared to the costs of electricity and thermal energy storage in four United States Independent System Operator (ISO) regions. Systems installed today may not yield positive net present value (NPV) compared to the use of natural gas. However, using estimated electricity prices, systems installed in 2030 using arbitrage alone could be profitable when compared to natural gas in some regions of the U.S. Furthermore, if capital expenditures could be reduced by 50% for sensible thermal storage systems by 2030, profitable systems are found across all regions. This implies that electrification of industrial process heat, when paired with inexpensive thermal energy storage systems, could be less expensive than brownfield natural gas systems, using arbitrage as the only source of revenue and without a dependency on any future policy drivers such as pricing externalities that could further incentivize the electrification of industrial process heat.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

Long-term impact of electrification and retrofits of the U.S residential building in diverse locations

The U.S. buildings sector contributes 30% of operational carbon emissions, with residential buildings accounting for 56%. Reducing residential carbon emissions is crucial for achieving net-zero carbon goal. While many studies examine energy efficiency retrofit (EER) and electrification, few explore their long-term impacts across diverse climates and dynamic grid clean energy penetrations, as well as their economic effects on households. Here, this study proposes a method to assess how EER and electrification affect long-term decarbonization and economics across different climates, focusing on carbon emissions, energy burden (the percentage of household income spent on energy), and payback period in four locations: Tampa, San Diego, Denver, and Great Falls. The study also introduces the concept of implicit energy burden by considering investment costs. Results show that while electrification can reduce long-term emissions with increased clean energy penetration, it may not always achieve decarbonization due to mismatches between clean energy availability and demand. In cooling-dominant locations, electrification lowers energy burden and peak demand, but in heating-dominant locations, it increases energy burden to 8.24%, raises peak demand by 632.78%, and shifts it from summer to winter. After integrating investment costs, the implicit energy burden can reach 8.35% in cold climates. For already highly electrified buildings in Denver and Great Falls, the payback period of EER measures can be shortened by up to 48.98%. The study highlights a tradeoff between decarbonization and energy burden alleviation, showing that while EER measures can reduce the energy burden, they only achieve one-quarter of the carbon emission reduction of electrification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reactivity of net-zero carbon alcohol fuels and their corresponding aldehyde intermediates on PGM-based commercial oxidation catalysts for lean-burn emissions control

Alcohol net-zero carbon fuels will play a significant role in decarbonization of the hard-to-electrify transportation sectors. However, the combustion process in alcohol-fueled engines generate toxic aldehydes. For commercialization of net-zero carbon fuels on engines, compliance with the stringent U.S. EPA regulations is necessary. Here, this contribution focuses on reactivity of alcohols and aldehydes on commercial diesel oxidation catalysts (DOC) to inform selection of future net-zero carbon fuels. Alcohol (and aldehyde) light-off temperatures were measured on aged DOCs under full synthetic engine-exhaust conditions. Methanol was the most reactive, while ethanol completely oxidized at higher temperatures. Alcohols typically formed less reactive aldehyde intermediates. DRIFTS revealed strongly adsorbing surface formates and acetates during methanol and ethanol oxidation, respectively, resulting in inhibition effects. Preliminary alcohol oxidation mechanisms combining flow reactor and DRIFTS observations are presented. Aldehydes inhibited CO oxidation. Minimal N 2 O formation was observed for the alcohols investigated.

Alcohol oxidation↗

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗

CO 2 conversion to syngas via electrification of endothermal reactors: Process design and environmental impact analysis

CO 2 utilization via reverse water gas shift (rWGS) reaction has been proposed as a path to the sustainable utilization. Here this work presents a detailed process modelling study where steam methane reforming (SMR) generated hydrogen was combined with rWGS to produce syngas (CO + H 2 ) with various hydrogen-to-carbon oxide ratios. To further decrease CO 2 emissions that may offset the benefits of CO 2 converted in rWGS, electrification of endothermal reactors, both SMR and rWGS was considered where CO 2 emitting fuel burning in the furnace was replaced by the emerging ohmic (resistive) heating. Material and energy inventory obtained from process design calculations was used to perform Life Cycle Analysis (LCA) to calculate environmental impacts of CO 2 consumption and reactor electrification. The results showed that greenhouse gas emissions, in CO 2 kg equivalent, were the lowest when both SMR and rWGS were heated using wind-generated electricity, decreasing from 25 to 10 kg CO 2 equivalent for H 2 :CO = 2:1 while the conventional electricity mix used for furnace electrical heating across the board of scenarios generated highest environmental impacts, much higher than those that used natural gas as fuel. Process economics calculations suggested that, when both SMR and rWGS were electrically heated, the process only showed product syngas cost parity with the conventional fuel heated design when electricity cost was ~$0.008/kWh. This suggests that CO 2 utilization scenarios involving process electrification need to be carefully considered from the total design perspective so they do not produce more greenhouse gases than in conventional non-electrified scenarios.

42 ENGINEERING↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inequality and the Future of Electric Mobility in 36 U.S. Cities: An Innovative Methodology and Comparative Assessment

Electric vehicles are seen as one of the technological solutions to transition our transportation systems away from carbon, and cities offer unique opportunities to electrify transportation. To be equitable, however, this transition will not merely require technological innovations. Acknowledging socio-spatial inequalities and creating strategies to address them are critical - yet relatively underexplored - dimensions of the transportation transition. This paper integrates relevant literature into a micro-urban social typology (MUST) approach that uses agglomerative clustering techniques to examine, first, the factors and attributes defining transportation inequities within 36 U.S. cities, and, second, the implications of these inequities for policies that foster a more equitable transportation transition. By combining socio-spatial and transportation data, we identified five MUSTs: Wealthy, Urban Disadvantaged, Urban Renters, Middle-Class Homeowners, and Rural/Exurban. Rather than being tied to any particular indicator (e.g., homeownership), these MUSTs contain intersecting factors and features of inequities. We compare transportation and health outcomes across MUSTs, and the results suggest that user-centric strategies and public investments are necessary to foster true transportation equity. These must go beyond the electrification of private vehicles and should be tailored to the specific characteristics of each MUST. These could include electric carpooling for the rural/exurban MUST and electrification of transit for the urban disadvantaged and renter MUSTs. Our typology offers a critical next step toward informing transportation transition policies to target critical sociodemographic, economic, and techno-infrastructural factors.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Sustainable aviation fuels from biomass and biowaste via bio- and chemo-catalytic conversion: Catalysis, process challenges, and opportunities

Sustainable aviation fuel (SAF) production from biomass and biowaste streams is an attractive option for decarbonizing the aviation sector, one of the most-difficult-to-electrify transportation sectors. Despite ongoing commercialization efforts using ASTM-certified pathways (e.g., lipid conversion, Fischer-Tropsch synthesis), production capacities are still inadequate due to limited feedstock supply and high production costs. New conversion technologies that utilize lignocellulosic feedstocks are needed to meet these challenges and satisfy the rapidly growing market. Combining bio- and chemo-catalytic approaches can leverage advantages from both methods, i.e., high product selectivity via biological conversion, and the capability to build C-C chains more efficiently via chemical catalysis. Herein, conversion routes, catalysis, and processes for such pathways are discussed, while key challenges and meaningful R&D opportunities are identified to guide future research activities in the space. Bio and chemo-catalytic conversion primarily utilize the carbohydrate fraction of lignocellulose, leaving lignin as a waste product. This makes lignin conversion to SAF critical in order to utilize whole biomass, thereby lowering overall production costs while maximizing carbon efficiencies. Thus, lignin valorization strategies are also reviewed herein with vital research areas identified, such as facile lignin depolymerization approaches, highly integrated conversion systems, novel process configurations, and catalysts for the selective cleavage of aryl C–O bonds. The potential efficiency improvements available via integrated conversion steps, such as combined biological and chemo-catalytic routes, along with the use of different parallel pathways, are identified as key to producing all components of a cost-effective, 100% SAF.

09 BIOMASS FUELS↗

Experimental driving performance evaluation of battery-powered medium and heavy duty all-electric vehicles

As the push to reduce air pollutants and carbon dioxide for global warming continues, there is increasing interest in the development and deployment of battery electric vehicles for heavy-duty applications as one of the critical and challenging steps of a broader effort to fully electrify the transportation sector. This study evaluated and quantified the energy consumption rates and energy regeneration rates for three heavy-duty battery electric vehicles (a step van, a yard tractor, and a class 8 truck) using driving cycle tests with a heavy-duty vehicle chassis dynamometer. Information in this area is currently very limited, and yet it is critical to understanding how effective heavy-duty battery electric vehicles will be for a wide range of applications as the electrification of the heavy-duty vehicle market continues to expand. Energy consumption rates ranged from 0.37 and 2.71 kWh/km for most vehicle/cycle combinations. On a diesel liter energy-equivalent basis, the heavy-duty vehicles had approximately 3 to 6 times better energy consumption rates compared to comparable diesel vehicles, with weight normalized energy consumption rates also comparing favorably to the current and future greenhouse gas/fuel economy standards for equivalent diesel vehicles. Based on battery capacities ranging from 80 to 215 kWh, the vehicle ranges varied from 38.18 km to 171.2 km, with ranges of 115.9 km to 171.2 km for most types of driving and lower ranges of 38.18 to 42.20 km for sustained grade cycles. Overall, the advantage of improved energy consumption rates coupled with improvements that can be expected for battery technology and vehicle range, provide promise for expanded use of heavy-duty vehicles going into the future.

33 ADVANCED PROPULSION SYSTEMS↗