Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrochemical sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High Temperature Protonic Conductors

High Temperature Protonic Conductors (HTPC) with the perovskite structure are envisioned for electrochemical membrane applications such as H2 separation, H2 sensors and fuel cells. Successive membrane commercialization is dependent upon addressing issues with H2 permeation rate and environmental stability with CO2 and H2O. HTPC membranes are conventionally fabricated by solid-state sintering. Grain boundaries and the presence of intergranular second phases reduce the proton mobility by orders of magnitude than the bulk crystalline grain. To enhanced protonic mobility, alternative processing routes were evaluated. A laser melt modulation (LMM) process was utilized to fabricate bulk samples, while pulsed laser deposition (PLD) was utilized to fabricate thin film membranes . Sr3Ca(1+x)Nb(2-x)O9 and SrCe(1-x)Y(x)O3 bulk samples were fabricated by LMM. Thin film BaCe(0.85)Y(0.15)O3 membranes were fabricated by PLD on porous substrates. Electron microscopy with chemical mapping was done to characterize the resultant microstructures. High temperature protonic conduction was measured by impedance spectroscopy in wet air or H2 environments. The results demonstrate the advantage of thin film membranes to thick membranes but also reveal the negative impact of defects or nanoscale domains on protonic conductivity.

Dynys, Fred↗

Chemochromic Indicators for the Detection of Hypergolic Fuels

The toxicity and hazard level associated with the use of hypergolic fuels necessitates the development of technology capable of detecting the presence of such fuels in a variety of different environments and conditions. The most commonly used sensors for the detection of hypergolic fuels are electrochemical in nature, which have serious limitations when used as area monitoring devices. Recent collaborative work between Kennedy Space Center and ASRC Aerospace has led to the development of indicators which exhibit a color change upon exposure to hydrazine under different conditions. The indicators under investigation on this developmental effort are para-dimethylaminobenzaldehyde (PDAB), various formulations of universal pH indicators, and potassium tetrachloroaurate (KAuCl4). These chemochromic indicators have been tested for the detection of hydrazine under various conditions: pure liquid fuel, aqueous fuel solution, saline aqueous fuel solutions, vapor fuel, and 3-month shelf life study, which included UV protection, thermal extremes, and normal storage conditions. The hypergolic fuel indicator test was conducted with the indicator impregnated into a wipe material to test the applicability of the indicator to be used to capture (absorb) and indicate the presence of hypergolic fuels. Each of the indicators performed well, with the universal pH indicator being the best candidate because of the visible response color change and the indicator stability after the shelf life study.

Santiago-Maldonado, E.↗

Proliferation Detection via Acoustic Monitoring of Pyroprocessing Equipment and Related Systems

In support of nuclear safeguards and nonproliferation, this effort is leveraging acoustic and seismic sensors to advance detection of pyroprocessing activities. Pyroprocessing, or electrochemical processing, is a method of separating irradiated nuclear fuel into its actinide and fission product components, enabling the reuse of fuel materials and reducing the radiotoxicity of the remaining waste. Verification and accountability in the process poses several challenges because of the high radiation environment and the presence of material holdup through the facility. Irregular or unaccounted-for equipment operation can signify diversion or misuse of critical materials. Acoustic and seismic sensors offer the capability to identify periods of equipment operation and help verify adherence to accountancy records.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermoelectric microdevice fabricated by a MEMS-like electrochemical process

Microelectromechanical systems (MEMS) are the basis of many rapidly growing technologies, because they combine miniature sensors and actuators with communications and electronics at low cost. Commercial MEMS fabrication processes are limited to silicon-based materials or two-dimensional structures. Here we show an inexpensive, electrochemical technique to build MEMS-like structures that contain several different metals and semiconductors with three-dimensional bridging structures. We demonstrate this technique by building a working microthermoelectric device. Using repeated exposure and development of multiple photoresist layers, several different metals and thermoelectric materials are fabricated in a three-dimensional structure. A device containing 126 n-type and p-type (Bi, Sb)2Te3 thermoelectric elements, 20 microm tall and 60 microm in diameter with bridging metal interconnects, was fabricated and cooling demonstrated. Such a device should be of technological importance for precise thermal control when operating as a cooler, and for portable power when operating as a micro power generator.

Evaluation Studies↗

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bio‐Imaging quorum sensing signal molecules in a soil‐mimic gel

Rhizosphere, the narrow region surrounding plant roots directly influenced by root exudates and the root associated microbiome, plays an important role in plant productivity and the rhizosphere is well known for stimulating microbial metabolic activities. How microbial communities interact to form stable, metabolically interconnected functional communities is an area of intense interest. The question remains on how microbially produced secreted molecules that function as intercellular communication signals shape the structure and function of microbial communities. Our goal is to detect and quantify signal molecules produced by microbes or plants in the root‐soil environment, spatially and temporarily. As a proof‐of‐concept, we are imaging diffusible extracellular microbial metabolites involved in a bacteria‐bacteria communication process called quorum‐sensing. Quorum‐sensing relies on the accumulation of high concentrations of signal molecules in the environment to control bacterial gene expression, influencing rhizosphere colonization and plant health. Local concentration of quorum sensing molecules are determined using aptamer based sensors. Aptamers that can specifically bind the desired signal molecules are selected through SELEX and immobilized on the surface of nano‐porous membranes. Binding of the signal molecules and aptamer covered surface results in changes in surface charge distribution and steric hinderance and thus modifying the transmembrane ionic transport. Changes in transmembrane impedance can be measured through electrochemical impedance spectroscopy methods to monitor local concentrations of signal molecules. Sensor responses were determined for different concentrations of signal molecules and results showed detection of C4‐HSL in a soil‐mimic solution with K D of 10 nM. We demonstrate that the quorum‐sensing signal molecule C4‐homoserine lactone and (C4‐HSL) can rapidly diffuse in a soil‐mimic gel, providing evidence for our use of a soil‐mimic for further aptasensor development and validation. The sensors were then inserted into soil mimic gel for monitoring C4‐HSL diffusion and the resulted impedance changes were used to determine the C4‐HSL concentration at different positions in the gel. Measurements of local C4‐HSL concentrations variation and numerical solution of diffusion equation were used to create 4D images of C4‐HSL molecule diffusion in the soil‐mimic gel.

Jiang, Nianyu↗

Electrochemical and Hydrodynamic Interferences on the Performances of an Oxygen Microsensor with Built-in Electrochemical Microactuator

A concept of novel electrochemical in situ self-calibration technique for an oxygen microsensor has been proposed to devise a convenient calibration method without an externally coupled apparatus. Systemic investigations on the influences of various electrochemical (pH) and hydrodynamic (solution stirring) conditions on the proposed microsensor performances are presented. The results suggest that: 1) The calibrating microenvironments can be manipulated with carefully engineered sensor designs and optimized generating signals; 2) The external oxygen permeable membrane is needed to minimize the electrochemical and hydrodynamic interferences.

Kim, Chang-Soo↗

LIMS Instrument Package (LIP) balloon experiment: Nimbus 7 satellite correlative temperature, ozone, water vapor, and nitric acid measurements

The Limb Infrared Monitor of the Stratosphere (LIMS) LIP balloon experiment was used to obtain correlative temperature, ozone, water vapor, and nitric acid data at altitudes between 10 and 36 kilometers. The performance of the LIMS sensor flown on the Nimbus 7 Satellite was assessed. The LIP consists of the modified electrochemical concentration cell ozonesonde, the ultraviolet absorption photometric of ozone, the water vapor infrared radiometer sonde, the chemical absorption filter instrument for nitric acid vapor, and the infrared radiometer for nitric acid vapor. The limb instrument package (LIP), its correlative sensors, and the resulting data obtained from an engineering and four correlative flights are described.

Lee, R. B., III↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous Pt(Au) Alloys for the Enhanced, Non–enzymatic Detection of Hydrogen Peroxide under Biofouling Conditions

The non-enzymatic electrochemical sensing of hydrogen peroxide (H 2 O 2 ) is described. This study utilized a 3D bicontinuous nanoporous platinum-gold alloy-based sensor (NP-Pt(Au) electrode), which has a morphology that resembles a molecular sieve. SEM and CV were used to evaluate the morphological and electrochemical characteristics of the NP-Pt(Au) electrodes. The cathodic voltammetric response of H 2 O 2 was enhanced at the NP-Pt(Au) as compared to planar Pt electrodes. Further, the nanoporous electrode was able to maintain the H 2 O 2 voltammetric profile even in the presence of the biofouling agent, serum albumin. Its application as a non-enzymatic sensor for the amperometric measurement of H 2 O 2 was explored.

36 MATERIALS SCIENCE↗

A high-temperature mixed potential CO gas sensor for in situ combustion control

An in situ, accurate and robust sensor that can sustain a high temperature of above 1000 °C is needed for on-site combustion monitoring because it can give real-time and local data to the control system to adjust the overall combustion efficiency. In this work, we find that nickel oxide (NiO) is a promising sensing material for CO which is a direct indicator of the status of the combustion process of a power plant. Under the conditions of 0.5–3% O 2 and 1000 °C, the fabricated yttrium-stabilized zirconia (YSZ)-based mixed potential sensor using porous NiO demonstrates good sensitivity to CO, showing a signal as high as 36 mV to 1000 ppm CO. The effects of gas transport, structure and geometry of the NiO electrode on the sensing performance are studied. Results show that fast gas transport is much beneficial to improved sensitivity. NiO having a porous structure is much more sensitive to CO than that having a dense structure. But the t90 (time to achieve 90% final signal magnitude) of the former is much longer due to slower gas diffusion inside the pores. It's worth noting that the NiO sensor exhibits a positive relationship with the CO content, opposite to other reported results of mixed potential sensors to detect CO. We find that this might be due to the electrochemical reduction, instead of oxidation of CO during the interaction with NiO at 1000 °C. Selectivity tests on how CO 2 , CH 4 and steam affect CO sensing are also demonstrated. NiO is insensitive to even 10% CO 2 . CH 4 does not shift the average value of the CO sensing response. However, it makes the sensing signal fluctuate more intensively. 2% steam exerts a great influence on NiO sensitivity to CO: it magnifies the sensitivity of the porous NiO electrode to a low CO range of 0–100 ppm, but inhibits its sensitivity to a CO range of 100 ppm to 1000 ppm. Lastly, an 11 day stability test demonstrates the promising stability property of the proposed NiO-based YSZ sensor.

20 FOSSIL-FUELED POWER PLANTS↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Enhancement‐Mode PEDOT:PSS Organic Electrochemical Transistors Using Molecular De‐Doping

Abstract Organic electrochemical transistors (OECTs) show great promise for flexible, low‐cost, and low‐voltage sensors for aqueous solutions. The majority of OECT devices are made using the polymer blend poly(ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), in which PEDOT is intrinsically doped due to inclusion of PSS. Because of this intrinsic doping, PEDOT:PSS OECTs generally operate in depletion mode, which results in a higher power consumption and limits stability. Here, a straightforward method to de‐dope PEDOT:PSS using commercially available amine‐based molecular de‐dopants to achieve stable enhancement‐mode OECTs is presented. The enhancement‐mode OECTs show mobilities near that of pristine PEDOT:PSS (≈2 cm 2 V −1 s −1 ) with stable operation over 1000 on/off cycles. The electron and proton exchange among PEDOT, PSS, and the molecular de‐dopants are characterized to reveal the underlying chemical mechanism of the threshold voltage shift to negative voltages. Finally, the effect of the de‐doping on the microstructure of the spin‐cast PEDOT:PSS films is investigated.

Keene, Scott T.↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗