Geophysical Characterization and Monitoring of the 200 Area Treated Effluent Disposal Facility to Support Permit Renewal; TEDF Geophysical Monitoring

The Treated Effluent Disposal Facility (TEDF), located in the 200 East Area of the Hanford Site, is a site where non-hazardous and non-radioactive liquid wastes are disposed into two state-permitted infiltration basins. In 2016, the Washington State Department of Ecology denied a permit renewal request for TEDF due to the inability to adequately assess the impact of TEDF discharge water on the underlying groundwater quality. TEDF overlies the relatively impermeable Ringold Lower Mud (RLM) unit, whose upper contact lies in the vadose zone approximately 30 m below ground surface and approximately 10 m above the water table boundary. The RLM is assumed to isolate TEDF discharge water from the natural groundwater aquifer, which is monitored using wellbores screened below the RLM. Therefore, samples collected from monitoring wells near TEDF are not considered representative of TEDF discharge water. Rather, TEDF discharge water is assumed to mound on top of the RLM to form a perched aquifer. To support permitting of the TEDF, a new monitoring well is required that can be used to sample water from the presumed perched water aquifer above the RLM. Ideally, the screened section of the well would be located at the peak of the perched water mound(s), which presumably occurs at the point of maximum vertical flux from TEDF to the RLM, or equivalently where the dominant infiltration flow paths reach the RLM. This report describes how time-lapse 3D electrical resistivity tomography (ERT) was used in conjunction with nominal TEDF discharge operations to image the dominant flow paths from each pond to the RLM. Results are summarized in Figure ES.1. Figure ES.1A shows a satellite image of the TEDF overlain by an array of surface ERT electrodes. The solid and dashed black circles denote the zones of maximum vertical flux at the RLM within the south and north ponds, respectively, and presumably the regions where perched water peaks during discharge. Figure ES.1B shows time-lapse difference imaging results approximately 15 days after switching discharge from the south pond to the north pond. Blue iso-surfaces beneath the north pond denote regions of increasing bulk electrical conductivity caused by increasing saturation due to infiltrating water. Red iso-surfaces beneath the south pond denote regions that were previously saturated during the south pond discharge and are now de-saturating, causing a decrease in bulk electrical conductivity. In both cases, the zones of maximum change mark the dominant flow paths to the RLM. Figure ES.1C shows time-lapse imaging results approximately 15 days after switching discharge from the north pond to the south pond. In this case, blue iso-surfaces mark the dominant flow paths to the RLM from the south pond. The red iso-surfaces mark the dominant flow paths that existed during discharge to the north pond. The regions of maximum change in bulk conductivity (due to saturation or desaturation) that mark the primary flow paths are equivalent in both cases and denoted by the dashed solid and black circles. If a perched water zone forms on the RLM, it is likely to mound within or near the dashed circle during discharge to the north pond, and in the solid circle during discharge to the south pond. In other words, if perched water mounding occurs, the circles mark the optimum locations suggested by the ERT imaging for monitoring boreholes to be placed, enabling samples to be collected that are representative of TEDF discharge impacts on groundwater quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Report for W911NF-23-1-0323: Development of Scalable Three-Dimensional Ion Traps for Quantum Information Processing

Trapped atomic ions are a promising platform for scalable quantum information processing. They lead in many key metrics such as single and two qubit gate fidelities, as well as quantum volume. We recently realized novel 3D ion traps with a high resolution 3D-printing process. The traps combine the scalability potential of surface chip traps with the superior trap performance of macroscopic 3D ion traps. Like photolithography, 3D-printing is a digitally defined process and hence allows for rapid iteration between design and fabrication. In contrast to photolithography, it also allows for fully defined 3D structures and, thus, is an ideal process to develop large, well-defined trap arrays with complex 3D electrode structures. Our current goal is to implement key procedures and perform critical measurements that justify incorporation of 3D-printed traps into large-scale quantum computing efforts. En route, we recently realized trapping in horizontal traps that are operating at cryogenic temperatures.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Synthesis of Manganese Hydroxide Nanowire Arrays for a High-Performance Zinc-Ion Battery

The morphology, microstructure as well as the orientation of cathodic materials are the key issues when preparing high-performance aqueous zinc-ion batteries (ZIBs). In this paper, binder-free electrode Mn(OH)2 nanowire arrays were facilely synthesized via electrodeposition. The nanowires were aligned vertically on a carbon cloth. The as-prepared Mn(OH)2 nanowire arrays were used as cathode to fabricate rechargeable ZIBs. The vertically aligned configuration is beneficial to electron transport and the free space between the nanowires can provide more ion-diffusion pathways. As a result, Mn(OH)2 nanowire arrays yield a high specific capacitance of 146.3 Ma h g−1 at a current density of 0.5 A g−1. They also demonstrates ultra-high diffusion coefficients of 4.5 × 10−8~1.0 × 10−9 cm2 s−1 during charging and 1.0 × 10−9~2.7 × 10−11 cm−2 s−1 during discharging processes, which are one or two orders of magnitude higher than what is reported in the studies. Furthermore, the rechargeable Zn//Mn(OH)2 battery presents a good capacity retention of 61.1% of the initial value after 400 cycles. This study opens a new avenue to boost the electrochemical kinetics for high-performance aqueous ZIBs.

25 ENERGY STORAGE↗

Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Ion Source Development for Neutron Generators

An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

36 MATERIALS SCIENCE↗

4D Printing of Stretchable Supercapacitors via Hybrid Composite Materials

Stretchable supercapacitors (SCs) have attracted significant attention in developing power-independent stretchable electronic systems due to their intrinsic energy storage function and unique mechanical properties. Most current SCs are generally limited by their low stretchability, complicated fabrication process, and insufficient performance and robustness. This study presents a facile method to fabricate arbitrary-shaped stretchable electrodes via 4D printing of conductive composite from reduced graphene oxide, carbon nanotube, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate. The electrode patterns of an arbitrary shape can be deposited onto prestretched substrates by aerosol-jet printing, then self-organized origami (ridge) patterns are generated after releasing the substrates from holding stretchers due to the mismatched strains. The stretchable electrodes demonstrate superior mechanical robustness and stretchability without sacrificing its outstanding electrochemical performance. The symmetric SC prototype possesses a gravimetric capacitance of ≈21.7 F g -1 at a current density of 0.5 A g -1 and a capacitance retention of ≈85.8% from 0.5 to 5 A g -1 . A SC array with arbitrary-shaped electrodes is also fabricated and connected in series to power light-emitting diode patterns for large-scale applications. Finally, the proposed method paves avenues for scalable manufacturing of future energy-storage devices with controlled extensibility and high electrochemical performance.

36 MATERIALS SCIENCE↗

Surface study of stainless steel electrode deposition from soil electrokinetic (EK) treatment using X-ray photoelectron spectroscopy (XPS)

Electrokinetic (EK) remediation relies upon application of a low-intensity direct current through the soil between stainless steel electrodes that are divided into a cathode array and an anode array. This mobilizes charged species, causing ions and water to move toward the electrodes. Metal ions and positively charged organic compounds move toward the cathode. Anions such as chloride, fluoride, nitrate, and negatively charged organic compounds move toward the anode. Here, this remediation techniques lead to a formation of a deposition at the both cathode and anode surface that mainly contributed byanion and cation from the remediated soil. In this research, Renggam-Jerangau soil species (HaplicAcrisol + RhodicFerralsol) with a surveymeter reading of 38.0 ± 3.9 μR/hr has been investigation in order to study the mobility of the anion and cation under the influence electric field. Prior to the EK treatment, the elemental composition of the soil and the stainless steel electrode are measured using XRF analyses. Next, the soil sample is remediated at a constant electric potential of 30 V within an hour of treatment period. A surface study for the deposition layer of the cathode and anode using X-ray Photoelectron spectroscopy (XPS) revealed that a narrow photoelectron signal from oxygen O 1s, carbon, C 1s silica, Si 2p, aluminium, Al 2p and chromium, Cr 2p exhibited on the electrode surface and indicate that a different in photoelectron intensity for each element on both electrode surface. In this paper, the mechanism of Si{sup 2+} and Al{sup 2+} cation mobility under the influence of voltage potential between the cathode and anode will be discussed in detail.

36 MATERIALS SCIENCE↗

Standard, Random, and Optimum Array conversions from Two-Pole resistance data

We present an array evaluation of standard and nonstandard arrays over a hydrogeological target. We develop the arrays by linearly combining data from the pole-pole (or 2-pole) array. The first test shows that reconstructed resistances for the standard Schlumberger and dipoledipole arrays are equivalent or superior to the measured arrays in terms of noise, especially at large geometric factors. The inverse models for the standard arrays also confirm what others have presented in terms of target resolvability, namely the dipole-dipole array has the highest resolution. In the second test, we reconstruct random electrode combinations from the 2-pole data segregated into inner, outer, and overlapping dipoles. The resistance data and inverse models from these randomized arrays show those with inner dipoles to be superior in terms of noise and resolution and that overlapping dipoles can cause model instability and low resolution. Finally, we use the 2-pole data to create an optimized array that maximizes the model resolution matrix for a given electrode geometry. The optimized array produces the highest resolution and target detail. Thus, the tests demonstrate that high quality data and high model resolution can be achieved by acquiring field data from the pole-pole array.

58 GEOSCIENCES↗

Understanding and removing surface states limiting charge transport in TiO2 nanowire arrays for enhanced optoelectronic device performance

Charge transport within electrode materials plays a key role in determining the optoelectronic device performance. Aligned single-crystal TiO 2 nanowire arrays offer an ideal electron transport path and are expected to have higher electron mobility. Unfortunately, their transport is found not to be superior to that in nanoparticle films. Here we show that the low electron transport in rutile TiO 2 nanowires is mainly caused by surface traps in relatively deep energy levels, which cannot be removed by conventional approaches, such as oxygen annealing treatment. Moreover, we demonstrate an effective wet-chemistry approach to minimize these trap states, leading to over 20-fold enhancement in electron diffusion coefficient and 62% improvement in solar cell performance. On the basis of our results, the potential of TiO 2 NWs can be developed and well-utilized, which is significantly important for their practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of V2O5/C core/shell arrays on graphene foam for electrochemical energy storage

Highlights: • Construct graphene foam supported V{sub 2}O{sub 5}/C c arrays. • Graphene foam + {sub 2}O{sub 5}/C arrays show large capacity and good cycles. • C layer is favorable for fast ion/electron transfer. - Abstract: V{sub 2}O{sub 5}-based materials are regarded as promising cathode materials for lithium-ion batteries (LIBs) because of their larger theoretical capacities than commercial cathode materials. Herein we develop a united solvothermal-chemical vapor deposition method for construction of bind-free V{sub 2}O{sub 5}/C core/shell arrays on the graphene foams positive electrodes of LIBs. Active V{sub 2}O{sub 5} nanoflakes with thicknesses of 10–15 nm are wrapped by ultrathin carbon layer of 2–4 nm forming core/shell arrays on the GF skeleton. The unique core/shell architecture can provide short ion/electron diffusion paths and substantial protection shell for the active materials, thus leading to accelerated electrochemical kinetics and enhanced cycling stability. A noticeable initial capacity of 290 mAh g{sup −1} at 1C in the voltage range of 2.0–4.0 V and 217 mAh g{sup −1} at 6C after 1000 cycles could be obtained for the GF + V{sub 2}O{sub 5}/C electrode, much better than its GF + V{sub 2}O{sub 5} counterpart.

25 ENERGY STORAGE↗

Vertically aligned carbon nanofiber as nano-neuron interface for monitoring neural function

Neural chips, which are capable of simultaneous, multi-site neural recording and stimulation, have been used to detect and modulate neural activity for almost 30 years. As a neural interface, neural chips provide dynamic functional information for neural decoding and neural control. By improving sensitivity and spatial resolution, nano-scale electrodes may revolutionize neural detection and modulation at cellular and molecular levels as nano-neuron interfaces. We developed a carbon-nanofiber neural chip with lithographically defined arrays of vertically aligned carbon nanofiber electrodes and demonstrated its capability of both stimulating and monitoring electrophysiological signals from brain tissues in vitro and monitoring dynamic information of neuroplasticity. This novel nano-neuron interface can potentially serve as a precise, informative, biocompatible, and dual-mode neural interface for monitoring of both neuroelectrical and neurochemical activity at the single cell level and even inside the cell.

59 BASIC BIOLOGICAL SCIENCES↗

Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring

We present the design and use of an ultrathin, stretchable sensor system capable of conformal lamination onto the skin, for precision measurement and spatial mapping of levels of hydration. This device, which we refer to as a class of ‘epidermal electronics’ due to its ‘skin-like’ construction and mode of intimate integration with the body, contains miniaturized arrays of impedance-measurement electrodes arranged in a differential configuration to compensate for common-mode disturbances. Experimental results obtained with different frequencies and sensor geometries demonstrate excellent precision and accuracy, as benchmarked against conventional, commercial devices. The reversible, non-invasive soft contact of this device with the skin makes its operation appealing for applications ranging from skin care, to athletic monitoring to health/wellness assessment.

47 OTHER INSTRUMENTATION↗

A simple, validated approach for design of two-dimensional periodic particle patterns via acoustophoresis

Two-dimensional patterning of microparticles enables a wide range of functional materials, including patterned energy storage electrodes, flexible electronics, and sensor arrays. Particle patterning via acoustics offers an attractive path to generate a wide variety of 2D periodic patterns that introduce tailorable hierarchical porosity, useful for controlling surface area, transport distances, and other properties. This method is most effective with micron scale particles and patterns of tens to hundreds of microns. To enable systematic exploration of the broad design space for such patterns, this work develops a model of 2D and 3D assembly of particles at high loadings and validates the obtained patterns against both experiments and more computationally intensive modeling techniques. Using this simple model, connections are mapped between input parameters (like actuation conditions, particle volume fraction, material properties) and output geometrical features (like void size and shape, pattern connectivity, and surface area) so that they can be tailored to given applications. The utility of this simple model is illustrated by predicting and then experimentally demonstrating new hierarchical patterns resulting from multiple waves of different frequencies interacting. These multiscale patterns offer the potential to lift the limits on surface area, diffusion distances, and other features.

42 ENGINEERING↗

Modulating surface acoustic wave generation through superconductivity

Surface acoustic waves (SAWs), with their five orders-of-magnitude slower propagation velocity, allow for considerably shorter wavelengths at the same frequency compared to electromagnetic waves. The short wavelengths allow for device miniaturization and on-chip integration. The generic design of these devices involves piezoelectric substrates with comb-like arrays of Al or Au electrodes known as interdigitated transducers (IDTs) deposited on the surface. However, Al and Au both have shortcomings at the cryogenic temperatures required for quantum applications, namely, the formation of two-level systems and the lack of superconductivity perpetuating Ohmic losses, respectively. In this work, SAWs are generated in the high-MHz to low-GHz range using niobium nitride (NbN) interdigitated transducers and Bragg reflectors. We demonstrate the fabrication of acoustic devices through photolithography and reactive ion etching. The sharp transition between superconducting and normal states and the corresponding change in SAW transmission allows for fine control of the “on” (superconducting) and “off” (normal) states of NbN, with a ΔT = 1 K separating the transmission minimum and maximum. We demonstrate a 16× difference in transmission between the “on” and “off” states of the device. The SAW transmission behavior mirrors the change in resistance of NbN at its T c . These findings open up new possibilities for the integration of NbN SAW resonators into existing quantum architectures based on NbN and a method for adjusting transmission properties independent of applied voltage.

36 MATERIALS SCIENCE↗

Ion microscopy with evolutionary-algorithm-based autofocusing

Abstract Ion microscopy is an established technique for laser focus diagnostics and the accurate, intensity-resolved measurement of laser ionization processes. In the present feasibility study, we discuss a new ion microscope design, which improves its resolution across a large range of magnifications and simplifies its operation. Instead of the common two einzel lens configuration, which is usually optimized for a fixed magnification, we propose a generic design consisting of an array of equally spaced ring electrodes, whose individually adjustable voltages are controlled by an evolutionary algorithm. In this way, we can realize aberration minimized magnifications between 25 and 100. Moreover, the algorithm can adjust the voltage settings under changing experimental conditions and facilitates autofocusing for user-defined magnification.

Haniel, Franz E.↗

Graphene oxide modified TiO 2 nanotube arrays: enhanced visible light photoelectrochemical properties

Novel nanocomposite films based on graphene oxide (GO) and TiO 2 nanotube arrays were synthesized by assembling GO on the surface of self-organized TiO 2 nanotube arrays through a simple assembling method. The composite films were characterized with field emission scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and UV-vis diffuse reflectance spectroscopy. Photoelectrochemical properties of the composite nanotube arrays were investigated under visible light illumination. Remarkably enhanced visible light photoelectrochemical response was observed for the GO decorated TiO 2 nanotube composite electrode compared with pristine TiO 2 nanotube arrays. Sensitizing effect of GO on the photoelectrochemical response of TiO 2 nanotube arrays was demonstrated and about 15 times enhanced maximum photoconversion efficiency was obtained with the presence of GO. Enhanced photocatalytic activity of TiO 2 nanotube arrays towards degradation of methyl blue was also demonstrated after modification of GO. The results presented here demonstrate GO to be efficient for the improvement of utilization of visible light for TiO 2 nanotube arrays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗