Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beams & optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

In-situ Characterizations of Microstructural Degradation of Perovskite Solar Cells

Rapid progress has been achieved in perovskite solar cells (PSCs), and their efficiencies have improved from 3.8 % to 24.2 % in less than a decade. With low-cost processing, PSCs have shown exciting photovoltaic (PV) properties, such as effective optical absorption, a long carrier lifetime, and unique defect tolerance. While recent studies demonstrated improved stability up to 100 days, PSC technology is still challenged to meet the stringent industry requirements for commercialization. Despite considerable efforts, the underlying physical mechanisms for the inferior stability of PSCs are not well understood. One reason for this divergence is that many established measurement techniques (e.g., quantum efficiency, photoluminescence) probe the properties on length scales far greater than that of electronic and/or structural inhomogeneity (i.e., < 1 μm near grain boundaries) and therefore characterize convoluted and/or averaged properties. Ion/electron beam-based techniques have been extensively used to access the microstructures of PSCs, enabling atomic/nanoscale structural, chemical, optical, and electrical characterizations. For example, focused ion beam (FIB) milling produces an atomically smooth surface that minimizes the artifacts attributed to the surface roughness. FIB techniques can also create a well-defined cross-section of PSCs without mechanical damage in a physical cleaving sample preparation. While powerful, there are some concerns about possible beam damage of inorganic-organic perovskites via chemical-bond breakage and local heating. This project aims to comprehensively understand how the microstructural/interfacial properties of PSCs (e.g., Methylammonium Lead Iodide [MAPbI 3 ]) are modified under the irradiating ion beams. Specifically, we investigate the sub-surface properties of PSCs before and after Ar-ion beam injections. Kelvin probe force microscopy (KPFM) measures the contact potential differences (CPDs). Photoluminescence (PL) microscopy in conjunction with Finite-Difference Time-Domain (FDTD) simulations infers the formation of a “dead layer” (< 15 nm) on the subsurface of MAPbI 3 during Ar+ milling processes while preserving the initial bulk properties. The x-ray photoemission spectroscopy (XPS) confirms this modified surface is a lead-rich and iodine-deficient surface. We initiate customizing in-situ measurement setup while measuring the local optical and electrical properties of PSC under thermal (cooling, heating) and light stressors. Our results provide in-depth knowledge of the ion-beam impact on metal-halide perovskites and how this modified sub-surface impacts their properties under accelerated stressors of light and heat. Intensive Monte Carlo simulations of an electron beam interacting with PSCs provide the beam energy distribution in PSCs, proposing possible measurement conditions of using e-beam with minimizing beam damage. Our in-situ measurement platform can accommodate the diverse architecture of PSC devices for studying deterioration mechanisms under mixed environmental stressors.

14 SOLAR ENERGY↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Phase retrieval for short wavelength orbital angular momentum beams using knife-edge diffraction

Laser beams operating in high order transverse modes, especially orbital angular momentum (OAM) modes, have been used increasingly in many frontier research areas. The characterization of these laser modes and the related component analysis can be carried out using the retrieved optical phase. However, conventional iterative phase retrieval methods, when applied to pure OAM modes, may fail because their convergence depends on the choice of the initial phase. Here, we present an improved phase retrieval method which can incorporate additional phase information obtained using knife-edge diffraction. Using no additional optics or few optics available in a wide spectral range, this method is particularly suitable for short wavelength lasers such as free-electron lasers (FELs) in the VUV, EUV, and X-ray regimes. Finally, this method has been tested using simulated beams, and successfully applied to experimentally generated beams from a HeNe laser and an FEL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stabilized Synthesis of 2D Verbeekite: Monoclinic PdSe 2 Crystals with High Mobility and In-Plane Optical and Electrical Anisotropy

PdSe 2 has a layered structure with an unusual, puckered Cairo pentagonal tiling. Its atomic bond configuration features planar 4-fold-coordinated Pd atoms and intralayer Se–Se bonds that enable polymorphic phases with distinct electronic and quantum properties, especially when atomically thin. PdSe 2 is conventionally orthorhombic, and direct synthesis of its metastable polymorphic phases is still a challenge. Here, we report an ambient-pressure chemical vapor deposition approach to synthesize metastable monoclinic PdSe 2 . Monoclinic PdSe 2 is shown to be synthesized selectively under Se-deficient conditions that induce Se vacancies. These defects are shown by first-principles density functional theory calculations to reduce the free energy of the metastable monoclinic phase, thereby stabilizing it during synthesis. Further, the structure and composition of the monoclinic PdSe 2 crystals are identified and characterized by scanning transmission electron microscopy imaging, convergent beam electron diffraction, and electron energy loss spectroscopy. Polarized Raman spectroscopy of the monoclinic PdSe 2 flakes reveals their strong in-plane optical anisotropy. Electrical transport measurements show that the monoclinic PdSe 2 exhibits n-type charge carrier conduction with electron mobilities up to ~298 cm 2 V –1 s –1 and a strong in-plane electron mobility anisotropy of ~1.9. The defect-mediated growth pathway identified in this work is promising for phase-selective direct synthesis of other 2D transition metal dichalcogenides.

2D material↗

Beam delivery and final focus systems for multi-TeV advanced linear colliders

The Beam Delivery System (BDS) is a critical component of a high-energy linear collider. It transports the beam from the accelerator and brings it to a focus at the Interaction Point. The BDS system includes diagnostic sections for measuring the beam energy, emittance, and polarization, as well as collimators for machine protection. The length of the BDS increases with collision energy. Higher collision energies also require higher luminosities, and this is a significant constraint on the design for energy-frontier machines. Here, we review BDS designs based on traditional quadrupole magnets and examine the challenges involved in extending these to the Multi-TeV regime consistent with requirements for advanced accelerator concepts.

43 PARTICLE ACCELERATORS↗

Beam delivery and beamstrahlung considerations for ultra-high energy linear colliders

As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50 × 1034 cm -2 s -1 in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the design of these machines. First, the Beam Delivery System (BDS) must not add significant length to the accelerator complex. Second, beam parameters must be chosen to mitigate beamstrahlung effects and maximize the luminosity-per-power of the machine. In this paper, we review advances in plasma lens technology that will help to reduce the length of the BDS system, and we detail new Particle-in-Cell simulation studies that will provide insight into beamstrahlung mitigation techniques. We apply our analysis to both $e$ + $e$ - and $γγ$ colliders. The challenges and solutions described in this paper are considered independently. In conclusion, a unified, self-consistent concept for a BDS system for a 15 TeV linear collider will be the subject of future work.

47 OTHER INSTRUMENTATION↗

Manufacturing Supply Chain Development for Modular Solar-Thermochemical Conversion Platform [Abstract]

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Stoichiometric Control and Optical Properties of BaTiO 3 Thin Films Grown by Hybrid MBE

BaTiO 3 is a technologically relevant material in the perovskite oxide class with above-room-temperature ferroelectricity and a very large electro-optical coefficient, making it highly suitable for emerging electronic and photonic devices. An easy, robust, straightforward, and scalable growth method is required to synthesize epitaxial BaTiO 3 thin films with sufficient control over the film's stoichiometry to achieve reproducible thin film properties. Here the growth of BaTiO 3 thin films by hybrid molecular beam epitaxy is reported. A self-regulated growth window is identified using complementary information obtained from reflection high energy electron diffraction, the intrinsic film lattice parameter, film surface morphology, and scanning transmission electron microscopy. Subsequent optical characterization of the BaTiO 3 films by spectroscopic ellipsometry revealed refractive index and extinction coefficient values closely resembling those of stoichiometric bulk BaTiO 3 crystals for films grown inside the growth window. Even in the absence of a lattice parameter change of BaTiO 3 thin films, degradation of optical properties is observed, accompanied by the appearance of a wide optical absorption peak in the IR spectrum, attributed to optical transitions involving defect states present. Therefore, the optical properties of BaTiO 3 can be utilized as a much finer and more straightforward probe to determine the stoichiometry level present in BaTiO 3 films.

36 MATERIALS SCIENCE↗

Toroidal plasma acceleration due to NBI fast ion losses in LTX- β

The recent Lithium Tokamak Experiment-Beta (LTX- β ) upgrade includes the addition of neutral beam injection (NBI) in the same direction as the plasma current (co- I P ) and a new toroidal Mirnov array for MHD characterization. In initial NBI experiments, a spontaneously rotating n = 1 MHD mode is seen to accelerate during NBI in the counter-beam direction, accompanied by a rise in electron density consistent with the beam-injected inventory but without a clear increase in plasma pressure. Together with analytic and numerical modeling of beam optics and fast ion confinement, these observations indicate the prompt loss of all or nearly all beam ions. However, the same modeling also suggests that planned upgrades to the Ohmic heating system should provide the fast ion confinement necessary for beam heating and core fueling. Here, a simple analytic model relates the momentum confinement time τ Φ to the observed evolution of mode rotation due to the combination of NBI momentum coupling, fast ion loss $\vec{J}\times\vec{B}$, and anomalous viscous torques, yielding τ Φ values consistent with past measurements of electron energy confinement time τ E,e .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Franck-Condon electron emission from polar semiconductor photocathodes

An analytical formulation of (optical-)phonon-mediated and momentum-resonant Franck-Condon emission of photoexcited electrons from polar semiconductors is shown to be very consistent with (i) the observed emission properties of a cesiated Ga⁢As⁢(001) photocathode at 808 nm [J. Phys. D: Appl. Phys. 54, 205301 (2021)] and (ii) the measured spectral emission properties of a Ga⁢N(0001) photocathode from just below its bandgap energy to 5 eV. The theoretical analysis in the parabolic band approximation predicts the form of both the quantum efficiency and mean transverse energy of photoemission as a function of the photocathode’s electron affinity and the electron temperature in the vicinity of its emission face. The good agreement between theory and experimental data also suggests that sub-10-nm rms surface roughness effects are not significant for polar semiconductor photocathodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrabright Electron Bunch Injection in a Plasma Wakefield Driven by a Superluminal Flying Focus Electron Beam

Here, we propose a new method for self-injection of high-quality electron bunches in the plasma wakefield structure in the blowout regime utilizing a “flying focus” produced by a drive beam with an energy chirp. In a flying focus the speed of the density centroid of the drive bunch can be superluminal or subluminal by utilizing the chromatic dependence of the focusing optics. We first derive the focal velocity and the characteristic length of the focal spot in terms of the focal length and an energy chirp. We then demonstrate using multidimensional particle-in-cell simulations that a wake driven by a superluminally propagating flying focus of an electron beam can generate GeV-level electron bunches with ultralow normalized slice emittance (~30 nm rad), high current (~17 kA), low slice energy spread (~0.1%), and therefore high normalized brightness (> 10 19 A/ m 2 /rad 2 ) in a plasma of density ~10 19 cm –3 . The injection process is highly controllable and tunable by changing the focal velocity and shaping the drive beam current. Nearterm experiments at FACET II where the capabilities to generate tens of kA, < 10 fs drivers are planned, could potentially produce beams with brightness near 10 20 A / m 2 / rad 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strongly Coupled Plasmon and Phonon Polaritons as Seen by Photon and Electron Probes

The ability to control and modify infrared excitations in condensed matter is of both fundamental and applied interest. Here we explore a system supporting low-energy excitations, in particular, mid-infrared localized plasmon modes and phonon polaritons that are tuned to be strongly coupled. We study the coupled modes by using far-field infrared spectroscopy, state-of-the-art monochromated electron energy-loss spectroscopy, numerical simulations, and analytical modeling. Here we demonstrate that the electron probe facilitates a precise characterization of polaritons constituting the coupled system, and enables an active control over the coupling and the resulting sample response both in frequency and space. Although far-field optical spectra can be substantially different from near-field electron energy-loss spectra, we show that a direct comparison is possible via postprocessing and right positioning of the electron beam. The resulting spectra allow us to evaluate the key parameters of the coupled system, such as the coupling strength, which we demonstrate to be probe independent. Our work establishes a rigorous description of the spectral features observed in light- and localized electron-based spectroscopies, which can be extended to the analysis of analogous optical systems with applications in heat management and electromagnetic field concentration or nanofocusing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of thermochemical treatments on laser-induced luminescence spectra from strontium titanate: comparison with swift ion-beam irradiation experiments

Results recently reported on the effect of thermochemical treatments on the (He-Cd) laser-excited emission spectra of strontium titanate (STO) are re-analyzed here and compared with results obtained under ion-beam irradiation. Contributing bands centered at 2.4 eV and 2.8 eV, which appear under laser excitation, present intensities dependent upon previous thermal treatments in oxidizing (O 2 ) or reducing atmosphere (H 2 ). As a key result, the emission band centered at 2.8 eV is clearly enhanced in samples exposed to a reducing atmosphere. From a comparison with the ionoluminescence data, it is concluded that the laser-excited experiments can be rationalized within a framework developed from ion-beam excitation studies. In particular, the band at 2.8 eV, sometimes attributed to oxygen vacancies, behaves as expected for optical transitions from conduction-band (CB) states to the ground state level of the self-trapped exciton center. The band at 2.0 eV reported in ion-beam irradiated STO, and attributed to oxygen vacancies, is not observed in laser-excited crystals. As a consequence of our analysis, a consistent scheme of electronic energy levels and optical transitions can now be reliably offered for strontium titanate.

74 ATOMIC AND MOLECULAR PHYSICS↗

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗