Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

Reversible phase transformations between Pb nanocrystals and a viscous liquid-like phase

Phase transformations have been a prominent topic of study for both fundamental and applied science. Solid-liquid reaction–induced phase transformations can be hard to characterize, and the transformation mechanisms are often not fully understood. Here, we report reversible phase transformations between a metal (Pb) nanocrystal and a viscous liquid-like phase unveiled by in situ liquid cell transmission electron microscopy. The reversible phase transformations are obtained by modulating the electron current density (between 1000 and 3000 electrons Å –2 s –1 ). The metal-organic viscous liquid-like phase exhibits short-range ordering with a preferred Pb-Pb distance of 0.5 nm. Assisted by density functional theory and molecular dynamics calculations, we show that the viscous liquid-like phase results from the reactions of Pb with the CH 3 O fragments from the triethylene glycol solution under electron beam irradiation. Such reversible phase transformations may find broad implementations.

36 MATERIALS SCIENCE↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Radiation Effects in Used Next Generation Nuclear Fuel Reprocessing Strategies

Given global commitments to significantly increase nuclear energy capacity, it is now more important than ever to develop efficient used nuclear fuel (UNF) management strategies to encourage widespread adoption of closed fuel cycles. To achieve this ambitious goal, a comprehensive understanding of radiation effects is essential for these next generation technologies, as radiolysis often limits longevity and performance. Here, we present new findings on: (i) the radiation robustness and performance of advanced sulfur chloride-based chlorination processes in the presence of nuclear materials (Fig. 1A); and (ii) the impacts of voloxidized uranium and rhenium complexation on monoamide-based UNF direct dissolution strategies (Fig 1B). These studies employed a combination of time-resolved electron pulse and dose accumulation gamma and electron beam irradiation techniques.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Impact of Nd ions on the chemical kinetic behavior of radiolytic transients in molten LiCl-KCl-NdCl3 salt mixtures

Pyrochemical reprocessing technologies can be used to recover valuable materials from used nuclear fuel (UNF), such as uranium. However, other critical materials, such as fission product neodymium, are challenging to recover from molten chloride eutectic mixtures (LiCl-KCl) due to the presence of multivalent states (Nd2+/Nd3+), disproportionation reactions, and re-dissolution in the molten chloride salt. Understanding, predicting, and controlling these processes is further complicated by the presence of ionizing radiation fields, for which little is known on the interaction of neodymium ions with the radiolytic transients (es– and Cl2.–) in molten LiCl-KCl salt mixtures. Here, chemical kinetics, from integrated electron pulse irradiation and transient absorption spectroscopy, are presented for the reaction of Nd3+ ions with es– and Cl2.– as a function of temperature (400–600 ?).

36 - MATERIALS SCIENCE↗

EPR Investigation of Temporal and Thermal Stability of Irradiated Sweeteners

Abstract Electron paramagnetic resonance was used to study the dosimetric properties of commercial sweeteners (sucrose, saccharin, and stevia). The results concluded that sugar has dosimetric properties of interest, which makes it suitable for dose reconstruction, emergency response, and nuclear forensics applications. The radiation dose response was investigated by irradiating samples up to 10 Gy and found to be linear. The post-irradiation stability of samples was observed to be useful for the intended applications. The results showed that the post-irradiation intensities vary from one sample to another, with the general trend demonstrating a small increase in intensities shortly after irradiation followed by an approximately constant leveling out. Finally, the effect of isochronal annealing was studied by heating samples to various temperatures. The results showed an overall stable behavior of the signal below melting temperature.

Environmental Sciences & Ecology↗

Electron Quantum Dynamics in Strong-Field Irradiation

The major goal of the project was to investigate the nonsequential ionization dynamics of atomic systems with two active electrons under intense laser irradiation. In order to gain insights into such nonlinear dynamical systems, one must resort to clever numerical methods due to the poor scaling of computational memory and time. Accordingly, we have extended the virtual detector method of Feuerstein and Thumm by incorporating quasi-classical “virtual” particles that evolve alongside the Schrödinger wavefunction. A major and recent part of this research effort was to further extend the virtual-detector method to model a two-active-electron atomic system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron-Stimulated Formation and Release of Molecular Hydrogen and Oxygen from Boehmite Nanoplatelet Films

Here, the production and release of H 2 and O 2 during and after electron (100–1000 eV) irradiation of boehmite nanoplatelet films was studied. H 2 and O 2 produced during irradiation likely correspond to electron-induced dissociation of the hydroxyls primarily in the terminal surface layers of the boehmite followed by the H· + H· → H 2 (g) and O + O → O 2 (g) combinative desorption reactions as well as the abstraction reactions H· + >OH – → H 2 (g) + >O·̅. Postirradiation temperature-programmed desorption shows a temperature-dependent release of H 2 but no additional release of O 2 . This process likely involves diffusion and recombination of H· atoms initially trapped between the γ-AlOOH planes followed by recombination at edge and surface sites. H 2 production upon thermal-annealing-irradiated material shows no dependence on incident electron flux, suggesting the precursor species (H·) trapped within the bulk are long-lived.

Jones, Brant M.↗

Comprehensive characterization of the irradiation effects of glassy carbon

Carbon materials have become increasingly diverse, finding applications in high-temperature and high-radiation environments. Glassy carbon, an allotrope known for its exceptional chemical inertness and desirable mechanical properties. However, understanding neutron irradiation effects in glassy carbon has proven challenging, primarily because of its unique nanopore structure. Here, this study presents a highly detailed microstructural characterization investigation of neutron-induced changes in glassy carbon, revealing how changes in nanopore structure and crystallinity impact the irradiation-induced shrinkage. Aberration-corrected scanning transmission electron microscopy (STEM) reveals pore closure that leads to material densification in the irradiated samples. Dimensional analysis combined with comparison to historical data suggest significant length shrinkage to occur. Neutron and in situ electron irradiation experiments suggest that glassy carbon transforms into so-called carbon onions, supporting the concept of shrinkage saturation. Investigating irradiation temperature effects using STEM, electron energy loss spectroscopy, x-ray diffraction, and Raman spectroscopy revealed partial amorphization at 210 °C–230 °C and preserved order in glassy carbon at 860 °C, coinciding with pore closure. Thermal property measurements were also conducted to assess the effects of densification and other changes in the atomic structure of glassy carbon. The results of this study have broad implications in the deployment of glassy carbon to nuclear environments, based around the observed changes in the thermal properties, and demonstrates the operational window for the onset of densification.

36 MATERIALS SCIENCE↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

Thermomechanical Properties of Neutron Irradiated Al 3 Hf-Al Thermal Neutron Absorber Materials

A thermal neutron absorber material composed of Al 3 Hf particles in an aluminum matrix is under development for the Advanced Test Reactor. This metal matrix composite was fabricated via hot pressing of high-purity aluminum and micrometer-size Al 3 Hf powders at volume fractions of 20.0, 28.4, and 36.5%. Room temperature tensile and hardness testing of unirradiated specimens revealed a linear relationship between volume fraction and strength, while the tensile data showed a strong decrease in elongation between the 20 and 36.5% volume fraction materials. Tensile tests conducted at 200 °C on unirradiated material revealed similar trends. Evaluations were then conducted on specimens irradiated at 66 to 75 °C to four dose levels ranging from approximately 1 to 4 dpa. Tensile properties exhibited the typical increase in strength and decrease in ductility with dose that are common for metallic materials irradiated at ≤0.4T m . Hardness also increased with neutron dose. The difference in strength between the three different volume fraction materials was roughly constant as the dose increased. Nanoindentation measurements of Al 3 Hf particles in the 28.4 vol% material showed the expected trend of increased hardness with irradiation dose. Transmission electron microscopy revealed oxygen at the interface between the Al 3 Hf particles and aluminum matrix in the irradiated material. Scanning electron microscopy of the exterior surface of tensile tested specimens revealed that deformation of the material occurs via plastic deformation of the Al matrix, cracking of the Al 3 Hf particles, and to a lesser extent, tearing of the matrix away from the particles. The fracture surface of an irradiated 28.4 vol% specimen showed failure by brittle fracture in the particles and ductile tearing of the aluminum matrix with no loss of cohesion between the particles and matrix. The coefficient of thermal expansion decreased upon irradiation, with a maximum change of –6.3% for the annealed irradiated 36.5 vol% specimen.

36 MATERIALS SCIENCE↗

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗

A deep learning model for automatic analysis of cavities in irradiated materials

Transmission electron microscopy (TEM) is a commonly used technique in materials science for defect investigation. Quantitative analysis of defects is important for understanding the properties of a material, but manual analysis of TEM micrographs can be time-consuming and prone to error, especially when the defects have irregular shapes rather than spherical shapes. Many existing methods or deep learning models do not handle a wide range of sizes for the same object type within a single image. In this work, we present a framework that enables users to train an instance segmentation model called Mask R- CNN on any microstructure dataset, perform multi-detection on the same image at different scales, and obtain properties (e.g., size, area) of the objects based on the desired shape (e.g., circle, ellipse, rectangle). Additionally, we have developed a parallel detection module that uses multiple GPUs to increase the efficiency of the object detection process. We demonstrate the capabilities of our framework using a set of TEM images of cavities with different shapes, size distributions, and background contrasts. Finally, we show that the performance of our model in terms of density, size, and swelling of the cavities is comparable to the human average and that our model achieves the highest recall value compared to existing methods due to the use of image multi-rescaling.

36 MATERIALS SCIENCE↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗