Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionic debris measurement of three extreme ultraviolet sources

Generation of debris in extreme ultraviolet (EUV) light sources is an inherent and real threat to the lifetime of collection optics. Debris measurement of these sources is useful to enable source suppliers to estimate collector lifetime. At the Center for Plasma Material Interactions (CPMI) at the University of Illinois, an Illinois calibrated spherical sector electrostatic energy analyzer (ICE) was built to measure the ion debris flux in absolute units. In addition to ion flux, the detector is also capable of identifying different ion species present in the plasma utilizing energy-to-charge ratio discrimination. The lifetime of the collector optics is calculated using the measured ion flux. In the current investigation we compare the measurement of ion debris production in three different EUV sources: the Energetiq EQ-10M, the AIXUV-100, and the XTREME XTS 13-35. In the EQ-10M source, three angular measurements are coupled with three variations in operating pressure to measure consequent effects on debris production. These measurements reveal four predominant ion species in the energetic debris analysis: C{sup +}, Si{sup +}, Xe{sup +}, and Xe{sup 2+}. The amount of debris is reduced as pressure is increased. Various debris mitigation methods are implemented in the AIXUV-100 source and results reveal that four ion species are observed (Ar{sup +}, Xe{sup +}, Xe{sup 2+}, and W{sup +}), though there does not seem to be a dominant species. The first mitigation technique, backstreaming argon toward the source, reduces the amount of Ar{sup +}, Xe{sup 2+}, and W{sup +}, yet increases the amount of Xe{sup +} The increase in Xe{sup +} flux is explained based on charge exchange phenomena. The ICE machine was then attached 1.92 m away from the pinch of XTS 13-35 source, and placed at 25 deg. away from the normal line. The comparison of results reveals that the XTS 13-35 and the EQ-10M sources produced comparable amounts of energetic ion flux per watt of EUV light produced. The AIXUV-100 source generated more ion debris flux per watt of EUV light than the other two sources, though it should be noted that the AIXUV-100 source was capable of producing more than ten times the amount of EUV light power compared to any of the other sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of secondary particle behavior in multiaperture, multigrid accelerator for the ITER neutral beam injector

Heat load on acceleration grids by secondary particles such as electrons, neutrals, and positive ions, is a key issue for long pulse acceleration of negative ion beams. Complicated behaviors of the secondary particles in multiaperture, multigrid (MAMuG) accelerator have been analyzed using electrostatic accelerator Monte Carlo code. The analytical result is compared to experimental one obtained in a long pulse operation of a MeV accelerator, of which second acceleration grid (A2G) was removed for simplification of structure. The analytical results show that relatively high heat load on the third acceleration grid (A3G) since stripped electrons were deposited mainly on A3G. This heat load on the A3G can be suppressed by installing the A2G. Thus, capability of MAMuG accelerator is demonstrated for suppression of heat load due to secondary particles by the intermediate grids.

43 PARTICLE ACCELERATORS↗

Angular and energy distribution of Sn ion debris ejected from a laser-produced plasma source, for laser power densities in the range suitable for extreme ultraviolet lithography

In this paper, experimental results are presented for the spatial and energy distributions of charge-discriminated Sn ions ejected from laser-produced plasmas. The plasmas were formed on solid, planar Sn targets, irradiated with a Nd:YAG laser. Ions were investigated using a calibrated electrostatic sector analyzer, scanning an energy-to-charge ratio range of 0.22 to 2.2 keV/e for emission angles between 20 and 80 degrees relative to target normal. Results were obtained for three laser power densities, in the region suitable for inducing significant extreme ultraviolet emission, of the order 1.5-8.1 x 10{sup 11} W/cm{sup 2}. The fully differentiated data were found to be well characterized by Gaussian fits, which allowed trends in the emission profiles to be readily quantified. Ions of set energy and charge were observed to possess a preferential angle of emission, the superposition of which yields a physical basis for the total angular emission observed previously and in this work. The experimental results obtained have been related to physical processes within the plasma that influence the energy and angle of ejection of ions from laser produced plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

43 PARTICLE ACCELERATORS↗

Beam energy tracking system on Optima XEx high energy ion implanter

The Axcelis Optima XEx high energy implanter is an RF linac-based implanter with 12 RF resonators for beam acceleration. Even though each acceleration field is an alternating, sinusoidal RF field, the well known phase-focusing principle produces a beam with a sharp quasi-monoenergetic energy spectrum. A magnetic energy filter after the linac further attenuates the low energy continuum in the energy spectrum often associated with RF acceleration. The final beam energy is a function of the phase and amplitude of the 12 resonators in the linac. When tuning a beam, the magnetic energy filter is set to the desired energy, and each linac parameter is tuned to maximize the transmission through the filter. Once a beam is set up, all the parameters are stored in a recipe, which can be easily tuned and has proven to be quite repeatable. The magnetic field setting of the energy filter selects the beam energy from the RF Linac accelerator, and in-situ verification of beam energy in addition to the magnetic energy filter setting has long been desired. An independent energy tracking system was developed for this purpose, using the existing electrostatic beam scanner as a deflector to construct an in-situ electrostatic energy analyzer. This paper will describe the system and performance of the beam energy tracking system.

43 PARTICLE ACCELERATORS↗

Angular ion species distribution in droplet-based laser-produced plasmas

The angular distribution of the ion species generated from a laser irradiated droplet target is measured. The employed instrument was an electrostatic energy analyzer with differential pumping. Singly and doubly charged ions were detected at an argon ambient gas pressure of 2 × 10{sup −2} mbar. The amount of Sn{sup +} and Sn{sup 2+} and their kinetic energy is measured from 45° to 120° from the laser axis. Sn{sup +} expands approximately isotropically, and Sn{sup 2+} expansion is peaked towards the incoming laser radiation. The singly charged ion kinetic energy is close to constant over the measurement range, while it decreases by around 30% for Sn{sup 2+}. A calibrated model of the ion expansion that includes recombinations correctly predicts the mean ion charge distribution. The model is able to qualitatively estimate the influence of the laser wavelength on the mean ion charge distribution. The results show a more pronounced isotropic distribution for shorter wavelengths, and a more forward-peaked distribution for longer wavelengths. The ion charge distribution expected without the ambient gas is estimated through the measured ion kinetic energy. The presence of the ambient gas results in a decrease of the mean ion charge state and a decrease in angular anisotropy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low charge state heavy ion production with sub-nanosecond laser

We have investigated laser ablation plasma of various species using nanosecond and sub-nanosecond lasers for both high and low charge state ion productions. We found that with sub-nanosecond laser, the generated plasma has a long tail which has low charge state ions determined by an electrostatic ion analyzer even under the laser irradiation condition for highly charged ion production. This can be caused by insufficient laser absorption in plasma plume. This property might be suitable for low charge state ion production. We used a nanosecond laser and a sub-nanosecond laser for low charge state ion production to investigate the difference of generated plasma using the Zirconium target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iron plasma generation using a Nd:YAG laser pulse of several hundred picoseconds

We investigated the high intensity plasma generated by using a Nd:YAG laser to apply a laser-produced plasma to the direct plasma injection scheme. The capability of the source to generate high charge state ions strongly depends on the power density of the laser irradiation. Therefore, we focused on using a higher power laser with several hundred picoseconds of pulse width. The iron target was irradiated with the pulsed laser, and the ion current of the laser-produced iron plasma was measured using a Faraday cup and the charge state distribution was investigated using an electrostatic ion analyzer. We found that higher charge state iron ions (up to Fe{sup 21+}) were obtained using a laser pulse of several hundred picoseconds in comparison to those obtained using a laser pulse of several nanoseconds (up to Fe{sup 19+}). We also found that when the laser irradiation area was relatively large, the laser power was absorbed mainly by the contamination on the target surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of laser-target parameters for the production of stable lithium beam

A laser ion source coupled with a radio frequency quadrupole linac accelerator is being proposed as a suitable system for the production of a low energy, high-current stable lithium beam. In order to maximize the lithium yield, plasmas generated by laser ablation of different materials based on lithium (Li, LiOH, and LiNbO3) have been characterized by using a Faraday cup and an electrostatic ion analyzer in the time of flight configuration. A wide range of laser power density has been investigated (109–1012 W/cm2) using two Nd:YAG lasers operating at different wavelengths (1064 nm and 532 nm), pulse durations (6 ns and 17 ns), and maximum energies (1400 mJ and 210 mJ). This paper outlines the pros and cons of the investigated materials by studying how the ion energy, yields, and charge state distributions are modified when the laser power density is changed. Considerable attention has been paid to the higher charge states of oxygen, which may occur with the same mass-to-charge ratio of Li3+. The analysis has evidenced that LiNbO3 represents a valid target since it allows minimizing the O6+/7Li3+ ratio down to 2.5% by using a laser power density of 1.8 × 1010 W/cm2. For such a condition, a Li3+ current of 1.4 mA/cm2 has been measured.

Cannavò, A. (ORCID:0000000309759630)↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

In situ analyses on negative ions in the sputtering process to deposit Al-doped ZnO films

The origin of high energy negative ions during deposition of aluminum doped zinc oxide (AZO) films by dc magnetron sputtering of an AZO (Al{sub 2}O{sub 3}: 2.0 wt %) target was investigated by in situ analyses using the quadrupole mass spectrometer combined with the electrostatic energy analyzer. High energy negative oxygen (O{sup -}) ions which possessed the kinetic energy corresponding to the cathode sheath voltage were detected. The maximum flux of the O{sup -} ions was clearly observed at the location opposite to the erosion track area on the target. The flux of the O{sup -} ions changed hardly with increasing O{sub 2} flow ratio [O{sub 2}/(Ar+O{sub 2})] from 0% to 5%. The kinetic energy of the O{sup -} ions decreased with decreasing cathode sheath voltage from 403 to 337 V due to the enhancement of the vertical maximum magnetic field strength at the cathode surface from 0.025 to 0.100 T. The AZO films deposited with the lower O{sup -} bombardment energy showed the higher crystallinity and improved the electrical conductivity.

36 MATERIALS SCIENCE↗

Nickel plasma produced by 532-nm and 1064-nm pulsed laser ablation

A comparison between laser ablation of nickel in vacuum by using 532-and 1064-nm Nd:YAG (Yttrium Aluminium Garnet) laser wavelengths, with an intensity of 5 x 10{sup 9} W/cm{sup 2}, is reported. Nanosecond pulsed ablation produces high nonisotropic emission of neutrals and ionic species. For 532-nm laser irradiation, mass quadrupole spectrometry, coupled to electrostatic ion deflection and time-of-flight measurements, allows estimation of the energy distributions of the emitted species from plasma. For 1064-nm laser ablation, a cylindrical electrostatic ion analyzer permits one to measure the yield and the charge state of the emitted ions and reconstruct the ion energy and charge state distributions. Neutrals show typical Boltzmann-like distributions, while ions show Coulomb-Boltzmann-shifted distributions depending on their charge state. Surface profiles of the ablated craters permitted study of the ablation threshold and yields of nickel in vacuum versus the laser fluence. The plasma temperature was evaluated using experimental data. Special regard is given to the ion acceleration process occurring inside the plasma due to the high electrical field generated at nonequilibrium plasma conditions and the angular distribution of the emitted species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-black coatings for space instruments: a comparison of traditional Ebonol C processes and a method for future repeatability

Ultra-black coatings have served various roles in space instrumentation and hardware. The Ebonol C coating has been used for various missions requiring low reflectivity on aluminum substrates that are electrically conducting. This coating is produced through the formation of a cupric oxide structure on an intermediate layer of copper applied to the aluminum. For many years, this commercial formulation has been used ubiquitously for space instruments. The coating relies upon details of the copper base layer that have been trade secret at various finishing companies, and the availability of the Ebonol C formulated chemistry from the chemical supplier. In recent years, this product has been discontinued at various times, leaving vendors to either rely on expired stock or to formulate their own equivalents. Here, we detail the processing methods, chemistries, and resultant coating structures that produce reflectance performance equivalent to baseline historical reflectance data. This process detail will ensure equivalent performance for such coatings for future missions and link the performance to past and currently deployed instruments.

36 MATERIALS SCIENCE↗

Ion optical design with applications to a solar wind mass spectrometer

The design of charged particle beam transport systems at lower energies is discussed. Topics discussed include: index of refraction, photometry, phase space, matrices, lenses and imaging, charged particle trajectories in crossed electric and magnetic fields, design parameters for the Wien filter, and electrostatic energy analyzer design, an annotated bibliography is presented.

Coplan, M.↗

Observations of plasmas in the Jovian magnetosphere

This paper presents an analysis of observations of large intensities of low-energy protons deep within the Jovian magnetosphere which were made by Pioneer 10 with an electrostatic plasma analyzer having an energy range from 108 eV to 4.80 keV. A proton density profile plotted against the earth-received time of the satellite signals reveals four significant plasma features: (1) a 'plasmasphere' with relatively high proton densities, located inside the flux tubes of Io at 6 Jupiter radii and extending toward the planet to at least 2.8 radii; (2) a 'plasmapause', on which Io's flux tubes are positioned; (3) a sparse sporadic zone beyond Io, extending out to 8 Jupiter radii; and (4) a ring current beginning at 8 radii, which extends outward in the form of a thin plasma disk and in which Europa is embedded. The thermal energies of the protons in each zone are determined, and it is suggested that Jupiter's ionosphere is the source of these protons. It is noted that the relationship of Io to the 'plasmapause' is probably of fundamental importance to that satellite's modulation of Jovian decametric radio emissions.

Frank, L. A.↗

The nuclear and ionic charge distribution particle experiments on the ISEE-1 and ISEE-C spacecraft

The ISEE-1 and ISEE-C instruments are designed to measure the elemental abundances, charge state composition, energy spectra, and angular distributions of energetic ions in the energy range 2 keV/charge to 80 MeV/nucleon and electrons between 75 and 1300 keV. The instrument consists of three sensor systems: (1) ULECA which is an electrostatic deflection system with rectangular solid-state detectors for the 3-560 keV/charge range; (2) ULEWATT which is a double dE/dX vs E thin-window flowthrough proportional counter/solid-state detector telescope for the 0.2-80 MeV/nucleon (Fe) range; and (3) ULEZEQ which is a combination of an electrostatic deflection analyzer and a thin-window dE/dX vs E system with thin-window proportional counter and position-sensitive solid-state detector. The applications of the instruments to solar and interplanetary phenomena and to magnetospheric acceleration and trapped particles are discussed.