Rhode Island Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Rhode Island homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Rhode Island homeowners will save $\$$11,011 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$629 for the 2012 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Iowa Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Iowa homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Iowa homeowners will save $\$$7,573 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$454 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Texas Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Texas homeowners. Moving to the 2012 IECC from the 2009 IECC is cost effective over a 30-year life cycle. On average, Texas homeowners will save $\$$3,456 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2012 IECC. Average annual energy savings are $\$$259 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes: Preprint

A parametric study was conducted using EnergyPlus version 6.0 to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate. The impacts of various dehumidification equipment and controls are analyzed on the high performance home. The study examined the combined effects of infiltrationand mechanical ventilation with balanced and unbalanced mechanical ventilation systems. Indoor relative humidity excursions were examined; specifically, the number of excursions, average excursion length, and maximum excursion length. Space relative humidity, thermal comfort, and whole-house source energy consumption were analyzed for indoor relative humidity set points of 50%, 55%, and 60%. Thestudy showed and explained why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in high-performance homes. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification should be provided to maintainspace relative humidity below 60% in a hot-humid climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alabama Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Alabama homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Alabama homeowners will save $\$$2,117 over 30 years under the 2009 IECC, with savings still higher at $\$$6,182 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$168 for the 2009 IECC and $462 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Kansas Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Kansas homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Kansas homeowners will save $\$$2,556 over 30 years under the 2009 IECC, with savings still higher at $\$$8,828 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$155 for the 2009 IECC and $\$$543 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Louisiana Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Louisiana homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Louisiana homeowners will save $\$$1,663 over 30 years under the 2009 IECC, with savings still higher at $\$$4,107 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$149 for the 2009 IECC and $\$$358 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mississippi Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Mississippi homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Mississippi homeowners will save $\$$2,022 over 30 years under the 2009 IECC, with savings still higher at $\$$5,400 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for both the 2009 and 2012 IECC. Average annual energy savings are $\$$164 for the 2009 IECC and $\$$422 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Missouri Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Missouri homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Missouri homeowners will save $\$$2,229 over 30 years under the 2009 IECC, with savings still higher at $\$$7,826 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$143 for the 2009 IECC and $\$$507 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tennessee Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Tennessee homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Tennessee homeowners will save $\$$1,809 over 30 years under the 2009 IECC, with savings still higher at $\$$6,102 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$123 for the 2009 IECC and $\$$415 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arizona Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Arizona homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost-effective over a 30-year life cycle. On average, Arizona homeowners will save $\$$3,245 over 30 years under the 2009 IECC, with savings still higher at $\$$6,550 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2009 and 2 years with the 2012 IECC. Average annual energy savings are $\$$231 for the 2009 IECC and $486 for the 2012 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Courthouse Building Energy Model: Building and System Characteristics

As part of the Department of Energy’s support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, researchers at Pacific Northwest National Laboratory apply a suite of prototype buildings covering 80% of the commercial building floor area in the United States for new construction. Efforts have begun to cover 90% of the commercial building floor area in the United States by developing prototype models for additional building types that include supermarket, laboratory, place of worship, public order and safety, and public assembly. “Courthouse” is a subcategory under the “Public Order and Safety” building type category defined by the Commercial Buildings Energy Consumption Survey (CBECS); other subcategories include police station, fire station, and detention and correctional facilities (i.e., jail, reformatory, or penitentiary). Oak Ridge National Laboratory used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents this research and reports the building and system characteristics necessary for developing a Courthouse prototype building energy model to be included in the Commercial Building Prototype Model suite.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

West Virginia Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for West Virginia homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, West Virginia homeowners will save $\$$1,996 over 30 years under the 2009 IECC, with savings still higher at $\$$7,301 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for both the 2009 and 2012 IECC. Average annual energy savings are $\$$135 for the 2009 IECC and $\$$480 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arkansas Energy and Cost Savings for New Single- and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) yield positive benefits for Arkansas homeowners. Moving to either the 2009 or 2012 IECC from the 2006 IECC is cost effective over a 30-year life cycle. On average, Arkansas homeowners will save $\$$1,948 over 30 years under the 2009 IECC, with savings still higher at $\$$6,679 with the 2012 IECC. After accounting for upfront costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2009 and 1 year for the 2012 IECC. Average annual energy savings are $\$$147 for the 2009 IECC and $\$466 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multifamily Housing Rehabilitation Process Improvements

Rea Ventures Group, LLC (Rea Ventures) partnered with Southface Energy Institute (Southface)—a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team—to rehabilitate 418 low-income multifamily rental apartments located at 14 properties in Georgia (International Energy Conservation Code Climate Zones 2–4). These 22-year-old units with individual utility meters were arranged in row house or townhouse style. Rehabilitation plans were developed using a process prescribed by the U.S. Department of Agriculture (USDA) Rural Development program, which partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide; this housing includes more than 14,000 existing multifamily housing developments. In 2012, more than $100 million in grants and loans were allocated for that purpose.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗