Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Least squares parameter estimation methods for material decomposition with energy discriminating detectors

Purpose: Energy resolving detectors provide more than one spectral measurement in one image acquisition. The purpose of this study is to investigate, with simulation, the ability to decompose four materials using energy discriminating detectors and least squares minimization techniques. Methods: Three least squares parameter estimation decomposition techniques were investigated for four-material breast imaging tasks in the image domain. The first technique treats the voxel as if it consisted of fractions of all the materials. The second method assumes that a voxel primarily contains one material and divides the decomposition process into segmentation and quantification tasks. The third is similar to the second method but a calibration was used. The simulated computed tomography (CT) system consisted of an 80 kVp spectrum and a CdZnTe (CZT) detector that could resolve the x-ray spectrum into five energy bins. A postmortem breast specimen was imaged with flat panel CT to provide a model for the digital phantoms. Hydroxyapatite (HA) (50, 150, 250, 350, 450, and 550 mg/ml) and iodine (4, 12, 20, 28, 36, and 44 mg/ml) contrast elements were embedded into the glandular region of the phantoms. Calibration phantoms consisted of a 30/70 glandular-to-adipose tissue ratio with embedded HA (100, 200, 300, 400, and 500 mg/ml) and iodine (5, 15, 25, 35, and 45 mg/ml). The x-ray transport process was simulated where the Beer-Lambert law, Poisson process, and CZT absorption efficiency were applied. Qualitative and quantitative evaluations of the decomposition techniques were performed and compared. The effect of breast size was also investigated. Results: The first technique decomposed iodine adequately but failed for other materials. The second method separated the materials but was unable to quantify the materials. With the addition of a calibration, the third technique provided good separation and quantification of hydroxyapatite, iodine, glandular, and adipose tissues. Quantification with this technique was accurate with errors of 9.83% and 6.61% for HA and iodine, respectively. Calibration at one point (one breast size) showed increased errors as the mismatch in breast diameters between calibration and measurement increased. A four-point calibration successfully decomposed breast diameter spanning the entire range from 8 to 20 cm. For a 14 cm breast, errors were reduced from 5.44% to 1.75% and from 6.17% to 3.27% with the multipoint calibration for HA and iodine, respectively. Conclusions: The results of the simulation study showed that a CT system based on CZT detectors in conjunction with least squares minimization technique can be used to decompose four materials. The calibrated least squares parameter estimation decomposition technique performed the best, separating and accurately quantifying the concentrations of hydroxyapatite and iodine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-H-206-07: Assessment of Geometric Distortion in EPI with a SPAMM Tagged Acquisition

Purpose: Echo planar imaging (EPI) is known to exhibit gross geometric distortion caused by multiple factors, including B0 inhomgeneity and transient eddy currents. However, diffusion weighted (DW) EPI has become indispensable for diagnosis and therapy assessment. We propose a methodology for quantifying distortion in EPI sequences that does not require the use of dedicated spatial accuracy phantoms, enabling flexibility in phantom design for QA of distortion effects in EPI protocols. Methods: The proposed methodology utilizes a saturation technique known as Spatial Modulation of Magnetization (SPAMM) that tags the imaging subject with saturated grid lines. Originally intended for tracking cardiac motion, these grids are applied to assess differences between diffusion weighting directions and b-values, or against a more geometrically robust sequence such as fast spin echo (FSE). The saturation preparation sequence consists of binomially weighted (e.g. 1-3-3-1) pulses interleaved with gradient blips along the frequency encode direction, followed by the same sequence with gradient blips in the phase encode direction. Three phantoms were assessed with these sequences: a spherical head-sized phantom, a large shimming phantom, and a modified PET ACR phantom that included compartments of water, air, oil, and Teflon. Each phantom was acquired with three sequences using parameters from a clinically appropriate protocol (22 cm head or 46 cm abdomen): a conventional DW-EPI sequence (3 DW directions), and both the DW-EPI and FSE sequences with tagging. Differences in grid locations were visualized with minimum intensity projection between images, and measured using intersecting locations on the grids. Results: Grid lines were clearly visualized on tagged images and enabled quantification of distortions. Maximum eddy current induced errors of 10.8 to 14.8 mm were observed in areas away from isocenter with DW gradients applied in various directions. Conclusion: SPAMM tagging provides a promising mechanism for assessing spatial distribution of distortion in EPI sequences.

60 APPLIED LIFE SCIENCES↗

An Experimental Investigation of Human Performance Differences Depending on Simulator Complexity

As a different approach to collect human reliability analysis (HRA) data compared to the full-scope simulator studies, Idaho National Laboratory (INL) has attempted to collect HRA data based on Simplified Human Error Experimental Program (SHEEP), which uses a simplified simulator and student participants. To date, INL has considered the SHEEP approach using simplified simulators such as Rancor Microworld and Compact Nuclear Simulator to complement – not replace – full-scope studies as well as to mainly collect HRA data for estimating nominal/basic human error probabilities (HEPs) needed in the HRA quantification process. This study is a part of the project aiming to suggest how to support full-scope data collection studies based on SHEEP. This paper first introduces major tasks within the SHEEP framework. Then, as one of the major tasks, why and how we have planned to experimentally investigate human performance differences depending on simulator complexity are mainly introduced in this paper.

99 GENERAL AND MISCELLANEOUS↗

Predicting critical heat flux with uncertainty quantification and domain generalization using conditional variational autoencoders and deep neural networks

Deep generative models (DGMs) can generate synthetic data samples that closely resemble the original dataset, addressing data scarcity. In this work, we developed a conditional variational autoencoder (CVAE) to augment critical heat flux (CHF) data used for the 2006 Groeneveld lookup table. To compare with traditional methods, a fine-tuned deep neural network (DNN) regression model was evaluated on the same dataset. Both models achieved small mean absolute relative errors, with the CVAE showing more favorable results. Uncertainty quantification (UQ) was performed using repeated CVAE sampling and DNN ensembling. The DNN ensemble improved performance over the baseline, while the CVAE maintained consistent results with less variability and higher confidence. Both models achieved small errors inside and outside the training domain, with slightly larger errors outside. Altogether, the CVAE performed better than the DNN in predicting CHF and exhibited better uncertainty behavior.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical Practices in Rigorously Assessing the Inherent Activity of Nanoparticle Electrocatalysts

Accurate activity measurements for electrocatalytic materials are the backbone of impactful electrocatalyst research. Inherent to accurate measurements is the correct accounting of the active catalyst sites and the design of experiments to ensure that these sites are participating in the measured reaction. Improvements in electrocatalyst activity for fuel cell reactions (hydrogen oxidation and oxygen reduction) are essential for the widespread adoption of this carbon-neutral energy source. Activities for these half-reactions can be reported in a variety of ways including specific activities, mass activities, volumetric activities, and half-wave potentials. These values are traditionally measured with a rotating disk electrode (RDE) in which the electrocatalyst is supported on a porous active layer film attached to the RDE. To accurately measure electrocatalyst activity with an RDE, two major sources of errors must be addressed: (i) accurate electrochemical surface area (ECSA) quantification and (ii) fast diffusion of reactants through the active layer film. In this contribution, we first aim to detail through RDE experiments and mass transport modeling the potential errors that can be observed when these factors are not properly addressed. We then present recommendations and discuss techniques for properly constructing electrocatalyst thin films and characterizing the ECSA on monometallic and novel alloy electrocatalysts. These practices, when adopted, ensure greater confidence and reliability in reports of electrocatalyst activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared extrapolations for atomic nuclei

Harmonic oscillator model-space truncations introduce systematic errors to the calculation of binding energies and other observables. We identify the relevant infrared (IR) scaling variable and give values for this nucleus-dependent quantity. We consider isotopes of oxygen computed with the coupled-cluster method from chiral nucleon–nucleon interactions at next-to-next-to-leading order and show that the IR component of the error is sufficiently understood to permit controlled extrapolations. By employing oscillator spaces with relatively large frequencies, that are well above the energy minimum, the ultraviolet corrections can be suppressed while IR extrapolations over tens of MeVs are accurate for ground-state energies. However, robust uncertainty quantification for extrapolated quantities that fully accounts for systematic errors is not yet developed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding Model Inadequacy in TRISO Nuclear Fuel Fission Products Release Models: Empirical and Mechanistic Approaches

The increasing use of tristructural isotropic (TRISO) particle fuel in both advanced and existing reactors necessitates a thorough evaluation of uncertainties and shortcomings in TRISO fission product release models. These inadequacies arise from the simplifications made in computational models compared to experimental data. Utilizing the BISON fuel performance code and experimental data from the Advanced Gas Reactor (AGR) program provides a unique chance to rigorously assess these inadequacies within a Bayesian uncertainty quantification (UQ) framework. This study contrasts the standard Bayesian framework with the Kennedy-O'Hagan (KOH) framework, which explicitly accounts for modeling inadequacies, in the context of UQ for TRISO silver release models. It examines both the traditional Arrhenius equation and a more advanced lower-length-scale (LLS)-informed model that incorporates microstructure information. The inverse UQ process applied to AGR-2 and AGR-3/4 datasets identified modeling inadequacy as the primary source of uncertainty, with experimental noise also being significant, while model parameter uncertainty was minimal. Both the Arrhenius and LLS-informed models showed similar levels of modeling inadequacy. For forward predictive UQ using the AGR-1 dataset, the KOH framework enhanced the accuracy and quality of quantified uncertainties by approximately 30% and 40%, respectively, compared to the standard Bayesian framework. This improvement was observed for both the Arrhenius and LLS-informed models. At the engineering scale, both models performed similarly, but the LLS-informed model outperformed the Arrhenius equation at the mesoscale. These findings underscore the importance of explicitly considering modeling inadequacy in the UQ process and highlight the need for ongoing refinement of physics-based models to address these shortcomings.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unpacking model inadequacy: The quantification of silver release from TRISO fuel by considering empirical and mechanistic approaches

Increasing adoption of the proposed tristructural isotropic (TRISO) particle fuel for both advanced and existing reactors makes it critical to assess and address any uncertainties and inadequacies of TRISO fission product release models. Model inadequacy stems from simplifications made to the computational model when compared to the experiments. The modeling and simulation efforts conducted using the BISON fuel performance code, along with the experimental campaigns carried out under the Advanced Gas Reactor Fuel Development and Qualification Program, afford a unique opportunity to conduct a rigorous modeling inadequacy assessment within the Bayesian uncertainty quantification (UQ) framework. Here, this study compares the standard Bayesian framework against the Kennedy-O'Hagan (KOH) framework, which explicitly represents modeling inadequacy, in regard to UQ for TRISO silver release models. For this purpose, both the traditional Arrhenius equation fitted to experimental data and the more advanced lower-length-scale (LLS)-informed model, which considers microstructure information, are independently considered. Applying the inverse UQ process on the AGR-2 and -3/4 datasets revealed modeling inadequacy to be the most dominant source of uncertainty. Experimental noise uncertainty is also significant; however, model parameter uncertainty can be considered negligible. Interestingly, both the Arrhenius equation and the LLS-informed model demonstrated similar levels of modeling inadequacy. For the forward predictive UQ, the KOH framework improved both the accuracy and quality of quantified uncertainties in comparison to the standard Bayesian framework. This is true for both the Arrhenius equation and the LLS-informed model. In comparing these modeling approaches, both demonstrated similar performance at the engineering scale, while the LLS-informed model expectedly outperformed the Arrhenius equation at the mesoscale. These conclusions highlight the importance of explicitly accounting for modeling inadequacy in the UQ process, and reinforce the need for continuous refinement of physics-based models in order to address the modeling inadequacy.

Advanced reactors↗

Determination of a Generic Human Error Probability Distribution, Part 2: A Dynamic SPAR-H Example Application

Humans are an integral part of a nuclear power plant (NPP) from its construction, to its everyday maintenance and operation. In the nuclear industry there are many approaches to quantifying component reliability, which is called probability risk assessment (PRA). In PRA there are two considerations given to the quantification, static and dynamic. Static is quantified before or after an operation; and dynamic is time dependent, in that the probability changes as real time data are provided. In PRA, the importance of the components is calculated, but what of the importance of the human component? There are several methods for human reliability analysis (HRA), which include but are not limited to: THERP, ATHEANA, CREAM, SPAR-H, ASEP, and SLIM. Each of these methods aims to provide a more accurate and objective human error probability (HEP) quantification. Of the methods listed above, ASEP, THERP, and SPAR-H are all inextricably linked. The Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method was generated to better generalize the Technique for Human Error Rate Prediction (THERP) and Accident Sequence Precursor (ASEP). THERP is mapped to specific scenario templates, and ASEP is a simplified screening method, while SPAR-H employs generalizations to describe the spectrum of human behavior while maintaining the same theoretical underpinnings. SPAR-H is a well-known and accepted HRA method that uses performance shaping factors (PSFs) to classify inputs to the human component. PSFs capture a wide variety of input data, including plant status, crew dynamics, task description, and psychological aspects of the human operator. Current efforts have been focused to further generalize SPAR-H in to a dynamic framework. These methods can fit into dynamic NPP simulations such as RAVEN / RELAP-7. In order to do this, a dynamic methodology is applied to model the human as would be applied to the components. This method is applied in part one in the accompanying paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct numerical simulations in solid mechanics for quantifying the macroscale effects of microstructure and material model-form error

Two fundamental approximations in macroscale solid-mechanics modeling are (1) the assumption of scale separation in homogenization theory and (2) the use of a macroscopic plasticity material model that represents, in a mean sense, the multitude of inelastic processes occurring at the microscale. With the goal of quantifying the errors induced by these approximations on engineering quantities of interest, we perform a set of direct numerical simulations (DNS) in which polycrystalline microstructures are embedded throughout a macroscale structure. The largest simulations model over 50,000 grains. The microstructure is idealized using a randomly close-packed Voronoi tessellation in which each polyhedral Voronoi cell represents a grain. An face centered cubic crystal-plasticity model is used to model the mechanical response of each grain. The overall grain structure is equiaxed, and each grain is randomly oriented with no overall texture. The detailed results from the DNS simulations are compared to results obtained from conventional macroscale simulations that use homogeneous isotropic plasticity models. The macroscale plasticity models are calibrated using a representative volume element of the idealized microstructure. Furthermore, we envision that DNS modeling will be used to gain new insights into the mechanics of material deformation and failure.

36 MATERIALS SCIENCE↗

Evaluation of Safety in a Radiation Oncology Setting Using Failure Mode and Effects Analysis

Purpose: Failure mode and effects analysis (FMEA) is a widely used tool for prospectively evaluating safety and reliability. We report our experiences in applying FMEA in the setting of radiation oncology. Methods and Materials: We performed an FMEA analysis for our external beam radiation therapy service, which consisted of the following tasks: (1) create a visual map of the process, (2) identify possible failure modes; assign risk probability numbers (RPN) to each failure mode based on tabulated scores for the severity, frequency of occurrence, and detectability, each on a scale of 1 to 10; and (3) identify improvements that are both feasible and effective. The RPN scores can span a range of 1 to 1000, with higher scores indicating the relative importance of a given failure mode. Results: Our process map consisted of 269 different nodes. We identified 127 possible failure modes with RPN scores ranging from 2 to 160. Fifteen of the top-ranked failure modes were considered for process improvements, representing RPN scores of 75 and more. These specific improvement suggestions were incorporated into our practice with a review and implementation by each department team responsible for the process. Conclusions: The FMEA technique provides a systematic method for finding vulnerabilities in a process before they result in an error. The FMEA framework can naturally incorporate further quantification and monitoring. A general-use system for incident and near miss reporting would be useful in this regard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ab initio nucleon-nucleus elastic scattering with chiral effective field theory uncertainties

Effective interactions for nucleon-nucleus elastic scattering from first principles require the use of the same nucleon-nucleon interaction in the structure and reaction calculations and a consistent treatment of the relevant operators at each order. Systematic investigations of the effect of truncation uncertainties of chiral nucleon-nucleon ( N N ) forces have been carried out for scattering observables in the two- and three-nucleons system as well as for bound-state properties of light nuclei. Here we extend this type of study to proton and neutron elastic scattering for 16 O and 12 C. Using the frameworks of the spectator expansion of multiple scattering theory as well as the no-core shell model, we employ one specific chiral interaction from the LENPIC collaboration and consistently calculate the leading-order effective nucleon-nucleus interaction up to the third chiral order, from which we extract elastic scattering observables. Then we apply pointwise as well as correlated uncertainty quantification for the estimation of the chiral truncation error. We calculate and analyze proton elastic scattering observables for 16 O and 12 C as well as neutron elastic scattering observables for 12 C between 65 and 185 MeV projectile kinetic energy. We find in all cases qualitatively similar results for the chiral truncation uncertainties as in few-body systems and assess them using similar diagnostic tools. The order-by-order convergence of the scattering observables for 16 O and 12 C is very reasonable around 100 MeV, while for higher energies the chiral expansion parameter becomes too large for convergence. Comparing proton and neutron differential cross sections reveals that their description is comparable up to around 100 MeV. Here, we also find a nearly perfect correlation between the differential cross section for neutron scattering and the N N Wolfenstein amplitudes for small momentum transfers. The diagnostic tools for studying order-by-order convergence in observables in few-body systems can be employed for observables in nucleon-nucleus scattering with only minor modifications provided the momentum scale in the problems is not too large. We also find that the chiral N N interaction on which our study is based gives a very good description of differential cross sections for 16 O and 12 C as low as 65-MeV projectile energy, particularly in the forward direction. In addition, the very forward direction of the neutron differential cross section mirrors the behavior of the N N interaction amazingly well.

6 ≤ A ≤ 19↗

Erratum: A Comparison of Closures for Stochastic Advection-Diffusion Equations

This note corrects an error in the authors' article [SIAM/ASA J. Uncertain. Quantif., 1 (2013), pp. 319 347] in which the cited work [Neuman, Water Resour. Res., 29(3) (1993), pp. 633 645] was incorrectly represented and attributed. Concentration covariance equations presented in our article as new were in fact previously derived in the latter work. In the original abstract, the phrase " . . .we propose a closed-form approximation to two-point covariance as a measure of uncertainty. . ." should be replaced by the phrase " . . .we study a closed-form approximation to two-point covariance, previously derived in [Neuman 1993], as a measure of uncertainty." The primary results in our article--the analytical and numerical comparison of existing closure methods for specific example problems are not changed by this correction.

stochastic PDE↗

Multiscale analysis in solids with unseparated scales: fine-scale recovery, error estimation, and coarse-scale adaptivity

There are several engineering applications in which the assumptions of homogenization and scale separation may be violated, in particular, for metallic structures constructed through additive manufacturing. Instead of resorting to direct numerical simulation of the macroscale system with an embedded fine scale, an alternative approach is to use an approximate macroscale constitutive model, but then estimate the model-form error using a posteriori error estimation techniques and subsequently adapt the macroscale model to reduce the error for a given boundary value problem and quantity of interest. Here, we investigate this approach to multiscale analysis in solids with unseparated scales using the example of an additively manufactured metallic structure consisting of a polycrystalline microstructure that is neither periodic nor statistically homogeneous. As a first step to the general nonlinear case, we focus here on linear elasticity in which each grain within the polycrystal is linear elastic but anisotropic.

42 ENGINEERING↗

AI/ML-Enhanced Wind Forecasts for Reducing Uncertainty in Prescribed Fire Planning

Prescribed fire is a vital tool for ecosystem management and wildfire risk reduction but its escalation is constrained by overly conservative burn windows because of uncertainties, for instance, in wind forecasts. This review describes the state of the art in weather product use by fire/smoke models and identifies three priority research gaps that artificial intelligence/machine learning (AI/ML) is well positioned to address: (1) spatial and temporal downscaling to meter-scale, sub-hourly wind fields; (2) bias correction for systematic model errors in complex terrain; and (3) robust uncertainty quantification to inform ensemble-based simulations. Emerging AI/ML techniques offer promising frameworks to address all three challenges. By providing high-resolution, bias-corrected, and probabilistic wind fields, AI/ML-enhanced forecasts will allow for expanded burn windows, improved ignition strategy design and a reduced reliance on expert intuition, especially when a prescribed fire is introduced into new areas.

54 ENVIRONMENTAL SCIENCES↗

Simulation studies and the need for field reflectance studies

There is a need to calibrate satellite data obtained at large polar (i.e., off-nadir) view angles for effects caused by scanner geometry and by the atmosphere. If such effects are not corrected for, then recorded radiance data will contain systematic and random errors which will make accurate target identification and quantification difficult. Adequate calibration of digital radiance data requires both an inductive analysis of digital satellite images and a deductive analysis based upon a priori simulation studies. The inputs to a simulation model (ground reflectance, atmospheric transmission and bandscatter) and their variability are dependent upon (for example) sun-target-sensor geometry. There is a major need to make accurate ground reflectance measurements to provide calibration information on the anisotropy of ground reflectance. There is also a need to assess atmospheric transmission and backscatter from the image itself. A potential simple, inexpensive method for making ground reflectance measurements in the above context is discussed.

Duggin, M. J.↗