Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

60 APPLIED LIFE SCIENCES↗

Minimizing treatment planning errors in proton therapy using failure mode and effects analysis

Purpose: Failure mode and effects analysis (FMEA) is a widely used tool to evaluate safety or reliability in conventional photon radiation therapy. However, reports about FMEA application in proton therapy are scarce. The purpose of this study is to apply FMEA in safety improvement of proton treatment planning at their center. Methods: The authors performed an FMEA analysis of their proton therapy treatment planning process using uniform scanning proton beams. The authors identified possible failure modes in various planning processes, including image fusion, contouring, beam arrangement, dose calculation, plan export, documents, billing, and so on. For each error, the authors estimated the frequency of occurrence, the likelihood of being undetected, and the severity of the error if it went undetected and calculated the risk priority number (RPN). The FMEA results were used to design their quality management program. In addition, the authors created a database to track the identified dosimetric errors. Periodically, the authors reevaluated the risk of errors by reviewing the internal error database and improved their quality assurance program as needed. Results: In total, the authors identified over 36 possible treatment planning related failure modes and estimated the associated occurrence, detectability, and severity to calculate the overall risk priority number. Based on the FMEA, the authors implemented various safety improvement procedures into their practice, such as education, peer review, and automatic check tools. The ongoing error tracking database provided realistic data on the frequency of occurrence with which to reevaluate the RPNs for various failure modes. Conclusions: The FMEA technique provides a systematic method for identifying and evaluating potential errors in proton treatment planning before they result in an error in patient dose delivery. The application of FMEA framework and the implementation of an ongoing error tracking system at their clinic have proven to be useful in error reduction in proton treatment planning, thus improving the effectiveness and safety of proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-241: Reduction in Planning Errors Via a Process Control Developed Using the Eclipse Scripting API

Purpose: Errors found during initial physics plan checks frequently require replanning and reprinting, resulting decreased departmental efficiency. Additionally, errors may be missed during physics checks, resulting in potential treatment errors or interruption. This work presents a process control created using the Eclipse Scripting API (ESAPI) enabling dosimetrists and physicists to detect potential errors in the Eclipse treatment planning system prior to performing any plan approvals or printing. Methods: Potential failure modes for five categories were generated based on available ESAPI (v11) patient object properties: Images, Contours, Plans, Beams, and Dose. An Eclipse script plugin (PlanCheck) was written in C# to check errors most frequently observed clinically in each of the categories. The PlanCheck algorithms were devised to check technical aspects of plans, such as deliverability (e.g. minimum EDW MUs), in addition to ensuring that policy and procedures relating to planning were being followed. The effect on clinical workflow efficiency was measured by tracking the plan document error rate and plan revision/retirement rates in the Aria database over monthly intervals. Results: The number of potential failure modes the PlanCheck script is currently capable of checking for in the following categories: Images (6), Contours (7), Plans (8), Beams (17), and Dose (4). Prior to implementation of the PlanCheck plugin, the observed error rates in errored plan documents and revised/retired plans in the Aria database was 20% and 22%, respectively. Error rates were seen to decrease gradually over time as adoption of the script improved. Conclusion: A process control created using the Eclipse scripting API enabled plan checks to occur within the planning system, resulting in reduction in error rates and improved efficiency. Future work includes: initiating full FMEA for planning workflow, extending categories to include additional checks outside of ESAPI via Aria database queries, and eventual automated plan checks.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-11: Sensitivity Analysis of Action Limits for Real-Time EPID-Based Delivery Verification System Using Artificial Clinical Relevant Error Simulations

Purpose: A real-time patient treatment delivery verification system using EPID (Watchdog) has been developed as an advanced patient safety tool. In a pilot study data was acquired for 119 prostate and head and neck (HN) IMRT patient deliveries to generate body-site specific action limits using statistical process control. The purpose of this study is to determine the sensitivity of Watchdog to detect clinically significant errors during treatment delivery. Methods: Watchdog utilizes a physics-based model to generate a series of predicted transit cine EPID images as a reference data set, and compares these in real-time to measured transit cine-EPID images acquired during treatment using chi comparison (4%, 4mm criteria) after the initial 2s of treatment to allow for dose ramp-up. Four study cases were used; dosimetric (monitor unit) errors in prostate (7 fields) and HN (9 fields) IMRT treatments of (5%, 7%, 10%) and positioning (systematic displacement) errors in the same treatments of (5mm, 7mm, 10mm). These errors were introduced by modifying the patient CT scan and re-calculating the predicted EPID data set. The error embedded predicted EPID data sets were compared to the measured EPID data acquired during patient treatment. The treatment delivery percentage (measured from 2s) where Watchdog detected the error was determined. Results: Watchdog detected all simulated errors for all fields during delivery. The dosimetric errors were detected at average treatment delivery percentage of (4%, 0%, 0%) and (7%, 0%, 0%) for prostate and HN respectively. For patient positional errors, the average treatment delivery percentage was (52%, 43%, 25%) and (39%, 16%, 6%). Conclusion: These results suggest that Watchdog can detect significant dosimetric and positioning errors in prostate and HN IMRT treatments in real-time allowing for treatment interruption. Displacements of the patient require longer to detect however incorrect body site or very large geographic misses will be detected rapidly.

60 APPLIED LIFE SCIENCES↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust Design Under Uncertainty in Quantum Error Mitigation

Error mitigation techniques are crucial to achieving near-term quantum advantage. Classical postprocessing of quantum computation outcomes is a popular approach for error mitigation, which includes methods, such as zero noise extrapolation, virtual distillation, and learning-based error mitigation. However, these techniques have limitations due to the propagation of uncertainty resulting from the finite shot number of a quantum measurement. In this work, we introduce general and unbiased methods for quantifying the uncertainty and error of error-mitigated observables based on the strategic sampling of error mitigation outcomes. We then extend our approach to demonstrate the optimization of performance and robustness of error mitigation under uncertainty. To illustrate our methods, we apply them to zero noise extrapolation and Clifford date regression in the ground state of the XY model simulated using depolarizing and International Business Machines Corporation (IBM) Toronto noise models, respectively. In particular, we optimize the choice of noise levels and the allocation of shots for zero noise extrapolation and the distribution of the training circuits for Clifford data regression. While our methods are readily applicable to any postprocessing-based error mitigation approach, in practice they must not be prohibitively expensive—even though they perform optimizations of the error mitigation hyperparameters requiring sampling of a statistical distribution of error mitigation outcomes. By leveraging surrogate-based optimization, we show that our methods can efficiently perform optimal design for a zero noise extrapolation implementation. We then further demonstrate the transferability of learned zero noise extrapolation hyperparameters to other similar circuits.

97 MATHEMATICS AND COMPUTING↗

Learning quantum computers' errors using interpretable neural networks

Learning and reducing the errors and noise in quantum computing systems is necessary for achieving quantum computation’s promise. However, rapid advances in experimental quantum computing are making this task increasingly difficult, because state-of-the-art systems now contain hundreds of qubits and many characterization techniques are hard to apply at this scale. Furthermore, complex kinds of errors in these systems, such as crosstalk and non-Markovian effects, must be understood and decreased, but these errors are challenging to study with most existing methods. In this project, we explored using neural networks for scalable characterization of complex errors in quantum computers. We proposed and demonstrated characterizing a quantum computer’s errors with neural networks that have interpretable parameters corresponding to the rates of different kinds of errors, within a sparse Lindbladian parameterization for errors. To enable scaling to many qubit systems, these networks then predict how these errors combine within quantum circuits and impact their outcomes using an efficient approximations. We demonstrated these networks ability to learn coherent crosstalk errors and context-dependent errors in a simulated 4-qubit system.

97 MATHEMATICS AND COMPUTING↗

An Assessment of the Error Due to Computing Waste Isolation Pilot Plant Porosity Using the Porosity Response Surface Approach

The Waste Isolation Pilot Plant Performance Assessment (WIPP PA) must predict the likelihood that radionuclides will escape into the biosphere via mechanisms that depend on geohydraulic flow. Ideally, one would predict the geohydraulic flow using coupled geohydraulic and geomechanical simulations, but such coupled simulations are not computationally tractable. Instead, Sandia has historically used a look-up table of porosities for a given fluid pressure and time, called the porosity response surface, but this approach can introduce porosity errors because it largely ignores the porosity’s dependence on the past fluid pressure history. This report discusses efforts to quantify these porosity errors for both the legacy and new porosity response surfaces. Six hundred different fluid pressure histories were fed through the legacy/new geomechanical model and the legacy/new porosity response surface to generate six hundred porosity error histories. The error associated with the legacy porosity surface was substantial, while the error associated with the new porosity surface was typically small, except when fluid pressures exceeded the lithostatic pressure at the repository. In response to the errors at high pressures, a preliminary study of the WIPP PA’s sensitivity to these porosity errors was conducted. The study found that reducing the porosity errors at high pressures negligibly affected predictions of radionuclide releases. Finally, an initial machine-learned model for porosity was developed. This ML model significantly reduced the porosity error at high pressures, but sizable errors remained, so more development is necessary before coupling an ML model to the geohydraulic model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Audit of the global carbon budget: estimate errors and their impact on uptake uncertainty

Over the last 5 decades monitoring systems have been developed to detect changes in the accumulation of carbon (C) in the atmosphere and ocean; however, our ability to detect changes in the behavior of the global C cycle is still hindered by measurement and estimate errors. Here we present a rigorous and flexible framework for assessing the temporal and spatial components of estimate errors and their impact on uncertainty in net C uptake by the biosphere. We present a novel approach for incorporating temporally correlated random error into the error structure of emission estimates. Based on this approach, we conclude that the 2&sigma; uncertainties of the atmospheric growth rate have decreased from 1.2 Pg C yr ₋1 in the 1960s to 0.3 Pg C yr ₋1 in the 2000s due to an expansion of the atmospheric observation network. The 2&sigma; uncertainties in fossil fuel emissions have increased from 0.3 Pg C yr ₋1 in the 1960s to almost 1.0 Pg C yr ₋1 during the 2000s due to differences in national reporting errors and differences in energy inventories. Lastly, while land use emissions have remained fairly constant, their errors still remain high and thus their global C uptake uncertainty is not trivial. Currently, the absolute errors in fossil fuel emissions rival the total emissions from land use, highlighting the extent to which fossil fuels dominate the global C budget. Because errors in the atmospheric growth rate have decreased faster than errors in total emissions have increased, a ~20% reduction in the overall uncertainty of net C global uptake has occurred. Given all the major sources of error in the global C budget that we could identify, we are 93% confident that terrestrial C uptake has increased and 97% confident that ocean C uptake has increased over the last 5 decades. Thus, it is clear that arguably one of the most vital ecosystem services currently provided by the biosphere is the continued removal of approximately half of atmospheric CO 2 emissions from the atmosphere, although there are certain environmental costs associated with this service, such as the acidification of ocean waters.

54 ENVIRONMENTAL SCIENCES↗

Universally high transcript error rates in bacteria

Errors can occur at any level during the replication and transcription of genetic information. Genetic mutations derived mainly from replication errors have been extensively studied. However, fundamental details of transcript errors, such as their rate, molecular spectrum, and functional effects, remain largely unknown. To globally identify transcript errors, we applied an adapted rolling-circle sequencing approach to Escherichia coli, Bacillus subtilis, Agrobacterium tumefaciens, and Mesoplasma florum, revealing transcript-error rates 3 to 4 orders of magnitude higher than the corresponding genetic mutation rates. The majority of detected errors would result in amino-acid changes, if translated. With errors identified from 9929 loci, the molecular spectrum and distribution of errors were uncovered in great detail. A G→A substitution bias was observed in M. florum, which apparently has an error-prone RNA polymerase. Surprisingly, an increased frequency of nonsense errors towards the 3' end of mRNAs was observed, suggesting a Nonsense-Mediated Decay-like quality-control mechanism in prokaryotes.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying the Effect of Lidar Turbulence Error on Wind Power Prediction

Currently, cup anemometers on meteorological towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability; however, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install meteorological towers at potential sites. As a result, remote-sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. Although lidars can accurately estimate mean wind speeds and wind directions, there is still a large amount of uncertainty surrounding the measurement of turbulence using these devices. Errors in lidar turbulence estimates are caused by a variety of factors, including instrument noise, volume averaging, and variance contamination, in which the magnitude of these factors is highly dependent on measurement height and atmospheric stability. As turbulence has a large impact on wind power production, errors in turbulence measurements will translate into errors in wind power prediction. The impact of using lidars rather than cup anemometers for wind power prediction must be understood if lidars are to be considered a viable alternative to cup anemometers.In this poster, the sensitivity of power prediction error to typical lidar turbulence measurement errors is assessed. Turbulence estimates from a vertically profiling WINDCUBE v2 lidar are compared to high-resolution sonic anemometer measurements at field sites in Oklahoma and Colorado to determine the degree of lidar turbulence error that can be expected under different atmospheric conditions. These errors are then incorporated into a power prediction model to estimate the sensitivity of power prediction error to turbulence measurement error. Power prediction models, including the standard binning method and a random forest method, were developed using data from the aeroelastic simulator FAST for a 1.5 MW turbine. The impact of lidar turbulence error on the predicted power from these different models is examined to determine the degree of turbulence measurement accuracy needed for accurate power prediction.

17 WIND ENERGY↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Setup Errors and Shape Changes on Breast Radiotherapy

Purpose: The purpose of the present study was to quantify the robustness of the dose distributions from three whole-breast radiotherapy (RT) techniques involving different levels of intensity modulation against whole patient setup inaccuracies and breast shape changes. Methods and Materials: For 19 patients (one computed tomography scan and five cone beam computed tomography scans each), three treatment plans were made (wedge, simple intensity-modulated RT [IMRT], and full IMRT). For each treatment plan, four dose distributions were calculated. The first dose distribution was the original plan. The other three included the effects of patient setup errors (rigid displacement of the bony anatomy) or breast errors (e.g., rotations and shape changes of the breast with respect to the bony anatomy), or both, and were obtained through deformable image registration and dose accumulation. Subsequently, the effects of the plan type and error sources on target volume coverage, mean lung dose, and excess dose were determined. Results: Systematic errors of 1-2 mm and random errors of 2-3 mm (standard deviation) were observed for both patient- and breast-related errors. Planning techniques involving glancing fields (wedge and simple IMRT) were primarily affected by patient errors ({approx}6% loss of coverage near the dorsal field edge and {approx}2% near the skin). In contrast, plan deterioration due to breast errors was primarily observed in planning techniques without glancing fields (full IMRT, {approx}2% loss of coverage near the dorsal field edge and {approx}4% near the skin). Conclusion: The influences of patient and breast errors on the dose distributions are comparable in magnitude for whole breast RT plans, including glancing open fields, rendering simple IMRT the preferred technique. Dose distributions from planning techniques without glancing open fields were more seriously affected by shape changes of the breast, demanding specific attention in partial breast planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Radiation Oncologists Would Disclose Errors: Results of a Survey of Radiation Oncologists and Trainees

Purpose: To analyze error disclosure attitudes of radiation oncologists and to correlate error disclosure beliefs with survey-assessed disclosure behavior. Methods and Materials: With institutional review board exemption, an anonymous online survey was devised. An email invitation was sent to radiation oncologists (American Society for Radiation Oncology [ASTRO] gold medal winners, program directors and chair persons of academic institutions, and former ASTRO lecturers) and residents. A disclosure score was calculated based on the number or full, partial, or no disclosure responses chosen to the vignette-based questions, and correlation was attempted with attitudes toward error disclosure. Results: The survey received 176 responses: 94.8% of respondents considered themselves more likely to disclose in the setting of a serious medical error; 72.7% of respondents did not feel it mattered who was responsible for the error in deciding to disclose, and 3.9% felt more likely to disclose if someone else was responsible; 38.0% of respondents felt that disclosure increased the likelihood of a lawsuit, and 32.4% felt disclosure decreased the likelihood of lawsuit; 71.6% of respondents felt near misses should not be disclosed; 51.7% thought that minor errors should not be disclosed; 64.7% viewed disclosure as an opportunity for forgiveness from the patient; and 44.6% considered the patient's level of confidence in them to be a factor in disclosure. For a scenario that could be considerable, a non-harmful error, 78.9% of respondents would not contact the family. Respondents with high disclosure scores were more likely to feel that disclosure was an opportunity for forgiveness (P=.003) and to have never seen major medical errors (P=.004). Conclusions: The surveyed radiation oncologists chose to respond with full disclosure at a high rate, although ideal disclosure practices were not uniformly adhered to beyond the initial decision to disclose the occurrence of the error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗