Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-I-34: Evaluating Use of AEC to Lower Dose for Lung Cancer Screening CT Protocols

Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD) image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-10: Lens Dose Reduction by Patient Position Modification During Neck CT Exams

Purpose: Irradiation of the lens during a neck CT may increase a patient’s risk of developing cataracts later in life. Radiologists and technologists at the National Institutes of Health Clinical Center (NIHCC) have developed new CT imaging protocols that include a reduction in scan range and modifying neck positioning using a head tilt. This study will evaluate the efficacy of this protocol in the reduction of lens dose. Methods: We retrieved CT images of five male patients who had two sets of CT images: before and after the implementation of the new protocol. The lens doses before the new protocol were calculated using an in-house CT dose calculator, National Cancer Institute dosimetry system for CT (NCICT), where computational human phantoms with no head tilt are included. We also calculated the lens dose for the patient CT conducted after the new protocol by using an adult male computational phantom with the neck position deformed to match the angle of the head tilt. We also calculated the doses to other radiosensitive organs including the globes of the eye, brain, pituitary gland and salivary glands before and after head tilt. Results: Our dose calculations demonstrated that modifying neck position reduced dose to the lens by 89% on average (range: 86–96%). Globe, brain, pituitary and salivary gland doses also decreased by an average of 65% (51–95%), 38% (−8–66%), 34% (−43–84%) and 14% (13–14%), respectively. The new protocol resulted in a nearly ten-fold decrease in lens dose. Conclusion: The use of a head tilt and scan range reduction is an easy and effective method to reduce radiation exposure to the lens and other radiosensitive organs, while still allowing for the inclusion of critical neck structures in the CT image. We are expanding our study to a total of 10 males and 10 females.

60 APPLIED LIFE SCIENCES↗

First Annual Progress Report on Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

The objective of this project is to develop and demonstrate methods for transmission of information in nuclear facilities by acoustic means along existing in-place metal piping infrastructure. Pipes are omnipresent in a nuclear facility, and penetrate enclosures and partitions, such as the containment building wall. In the envisioned acoustic communication (AC) system, packets of information will be transmitted as guided acoustic waves along pipes. Performance of AC hardware and network protocols for efficient and secure communications under development in this project will be eventually evaluated in a representative nuclear power plant environment. Research efforts in the first year of this project have been focused on identification of appropriate transducers, and evaluation of their performance for information transmission along nuclear-grade metallic pipes. COMSOL computer simulations were performed to study acoustic wave generation, propagation, and attenuation on pipes. An experimental benchtop system was used to evaluate signal attenuation and spectral dispersion using piezo-electric transducers (PZTs) and electromagnetic acoustic transducers (EMATs). Communication protocols under evaluation consisted on-off keying (OOK) signal modulation, in particular amplitude shift keying (ASK) and phase shift keying (PSK). Tradeoffs between signal power and communication data rate were considered for ASK and PSK coding schemes.

42 ENGINEERING↗

Approach to pediatric renal tumors: an imaging review

Renal tumors comprise 7% of all childhood cancers. A wide variety of renal tumors can affect the pediatric kidneys, which can be broadly classified as primary benign tumors, primary malignant tumors, and metastatic lesions. This article aims to enumerate usual benign and malignant renal tumors that can occur in childhood and emphasizes the characteristic imaging appearances which aid in their differential diagnosis. Additionally, the leading role of the Radiologist in primary diagnosis of renal infiltration by hematological malignancies and contiguous invasion by neuroblastoma is also introduced and unraveled. Imaging protocol comprises initial Ultrasound evaluation with subsequent computed tomography (CT) and/or Magnetic resonance imaging (MRI), all of which are invaluable in confirming the diagnosis, documenting the organ of origin, describing extent of local and distant spread. The complimentary role of nuclear medicine studies in delineating differential renal function, post-operative complications, and metastasis is also highlighted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An international survey of building energy codes and their implementation

Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, and geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.

54 ENVIRONMENTAL SCIENCES↗

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MO-AB-BRA-10: Cancer Therapy Outcome Prediction Based On Dempster-Shafer Theory and PET Imaging

Purpose: In cancer therapy, utilizing FDG-18 PET image-based features for accurate outcome prediction is challenging because of 1) limited discriminative information within a small number of PET image sets, and 2) fluctuant feature characteristics caused by the inferior spatial resolution and system noise of PET imaging. In this study, we proposed a new Dempster-Shafer theory (DST) based approach, evidential low-dimensional transformation with feature selection (ELT-FS), to accurately predict cancer therapy outcome with both PET imaging features and clinical characteristics. Methods: First, a specific loss function with sparse penalty was developed to learn an adaptive low-rank distance metric for representing the dissimilarity between different patients’ feature vectors. By minimizing this loss function, a linear low-dimensional transformation of input features was achieved. Also, imprecise features were excluded simultaneously by applying a l2,1-norm regularization of the learnt dissimilarity metric in the loss function. Finally, the learnt dissimilarity metric was applied in an evidential K-nearest-neighbor (EK- NN) classifier to predict treatment outcome. Results: Twenty-five patients with stage II–III non-small-cell lung cancer and thirty-six patients with esophageal squamous cell carcinomas treated with chemo-radiotherapy were collected. For the two groups of patients, 52 and 29 features, respectively, were utilized. The leave-one-out cross-validation (LOOCV) protocol was used for evaluation. Compared to three existing linear transformation methods (PCA, LDA, NCA), the proposed ELT-FS leads to higher prediction accuracy for the training and testing sets both for lung-cancer patients (100+/−0.0, 88.0+/−33.17) and for esophageal-cancer patients (97.46+/−1.64, 83.33+/−37.8). The ELT-FS also provides superior class separation in both test data sets. Conclusion: A novel DST- based approach has been proposed to predict cancer treatment outcome using PET image features and clinical characteristics. A specific loss function has been designed for robust accommodation of feature set incertitude and imprecision, facilitating adaptive learning of the dissimilarity metric for the EK-NN classifier.

60 APPLIED LIFE SCIENCES↗

Battery Safety Testing

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real world failure conditions. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids). Our work will provide empirical data on the mechanical behavior of batteries under compressive load to understand how a battery may behave in a vehicle crash scenario. This work is performed in collaboration with the U.S. Council for Automotive Research (USCAR) and Computer Aided Engineering of Batteries (CAEBAT). These programs have supported the design and development of a drop tower testing apparatus to close the gap between cell/string level testing and full scale crash testing with true dynamic rate effects.

25 ENERGY STORAGE↗

Battery Testing FY 2017 Annual Progress Report

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real-world failure conditions. When scaling from cell to the battery level, a detailed understanding of cell interactions provides insight on safety performance. Single point failures from a cell or group of cells can be initiated by a number of triggers including internal short circuit, misuse or abuse, or component failure at the battery or system level. Propagation of a single failure event (regardless of the initiation trigger) through an entire battery, system, or vehicle is an unacceptable outcome with regards to EV battery safety. In this FY, our work has focused on evaluating the propagation of a single cell thermal runaway event through a battery using a variety of design considerations with an emphasis on passive thermal management impacts. This has been coupled with thermal modeling by NREL for these testing conditions. In addition, alternative failure initiation methods have been evaluated to provide direct comparisons of possible energy injection between modes. This data was compiled to better identify what propagation test method is appropriate given certain battery designs. Expanding the analysis of short circuit current during failure propagation has been done for EV relevant chemistries. Ongoing test development and validation to obtain these values has been achieved. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids). Our work will provide empirical data on the mechanical behavior of batteries under compressive load to understand how a battery may behave in a vehicle crash scenario. This work is performed in collaboration with the U.S. Council for Automotive Research (USCAR) and Computer Aided Engineering of Batteries (CAEBAT). These programs have supported the design and development of a drop tower testing apparatus to close the gap between cell/string level testing and full scale crash testing with true dynamic rate effects.

25 ENERGY STORAGE↗

Battery Abuse Testing

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real-world failure conditions. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids). This year saw the stand up of a new drop tower tester capable of providing dynamic mechanical test results.

25 ENERGY STORAGE↗

I.6.C Battery Safety Testing

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real world failure conditions. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids).

25 ENERGY STORAGE↗

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Evaluation of DNA Extraction Efficiency in Diverse Algae Strains Using Commercial Kits and Lysis Approaches

Efficient DNA extraction is essential for accurately monitoring microalgae communities in large-scale cultivation systems such as raceway ponds and wastewater ponds. Traditional phenol chloroform extracts are a staple in microbiology but are obsolete for routine sampling due to its high toxicity reagents and time intensive setups. Commercial DNA extraction kits are more favorable for the microbes found in these ponds, but lack specific kits made for these communities. Little is known about which kits perform the best, leading researchers to use a variety of different kits with inconsistent results. This project compared one precipitation based commercial kit (Lucigen Masterpure) and five wash based kits (Monarch, Zymo Quick-DNA, and three Qiagen DNeasy kits) using four brackish algae strains to determine which methods yield the greatest quantity and quality of genomic DNA. Extractions were evaluated using the manufacturers protocol, and additional pretreatment options were administered before a single kit to compare its potential in being added routinely before extractions. Pretreatment options included both cryogenic freeze-thawing and heat incubation using enzymes. DNA was quantified using Qubit fluorometry and NanoDrop purity ratios. Overall, the Qiagen PowerWater kit provided the highest DNA yield and purity, but at a significantly higher cost then the precipitation-based kit (MasterPure). It was also noted that while the precipitation-based kit was significantly cheaper, provided similar results, it took significantly more time to complete a single run. Cryogenic pretreatment (6x cycles) increased average DNA yields by up to 80%, whereas enzymatic pretreatment most improved purity ratios without substantially improving quantity. The results suggest that it may be more cost and time efficient to use Qiagen kits with the addition of lysis pretreatments to procure better results. Future works includes developing a better system to efficiently collect multi variable data, and to upscale to artificial polycultures using similar methodologies alongside sequencing to confirm kit results.

59 BASIC BIOLOGICAL SCIENCES↗

File I/O for MPI Applications in Redundant Execution Scenarios

As multi-petascale and exa-scale high-performance computing (HPC) systems inevitably have to deal with a number of resilience challenges, such as a significant growth in component count and smaller circuit sizes with lower circuit voltages, redundancy may offer an acceptable level of resilience that traditional fault tolerance techniques, such as checkpoint/restart, do not. Although redundancy in HPC is quite controversial due to the associated cost for redundant components, the constantly increasing number of cores-per-processor is tilting this cost calculation toward a system design where computation, such as for redundancy, is much cheaper and communication, needed for checkpoint/restart, is much more expensive. Recent research and development activities in redundancy for Message Passing Interface (MPI) applications focused on availability/reliability models and replication algorithms. This paper takes a first step toward solving an open research problem associated with running a parallel application redundantly, which is file I/O under redundancy. The approach intercepts file I/O calls made by a redundant application to employ coordination protocols that execute file I/O operations in a redundancy-oblivious fashion when accessing a node-local file system, or in a redundancy-aware fashion when accessing a shared networked file system. A proof-of concept prototype is presented and a number of coordination protocols are described and evaluated. The results show the performance impact for redundantly accessing a shared networked file system, but also demonstrate the capability to regain performance by utilizing MPI communication between replicas and parallel file I/O.

99 GENERAL AND MISCELLANEOUS↗

SU-F-T-539: Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Radiation Therapy Treatments

Purpose: To compare the treatment plan quality and dose gradient near the hippocampus between VMAT (RapidArc) and IMRT delivery techniques for whole brain radiation therapy. Methods: Fifteen patients were evaluated in this retrospective study. All treatments were planned on Varian Eclipse TPS, using 3-Arc VMAT and 9-Field IMRT, following NRG Oncology protocol NRG-CC001 guidelines evaluated by a single radiation oncologist. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 100% of the dose covering 95% of the target volume. Identical contour sets and dose-volume constraints following protocol guidelines were also applied in all plans. A paired t-test analysis was used to compare VMAT and IMRT plans. Results: NRG-CC001 protocol dose-volume constraints were met for all VMAT and IMRT plans. For the planning target volume (PTV), the average values for D2% and D98% were 6% lower and 4% higher in VMAT than in IMRT, respectively. The average mean and maximum hippocampus doses in Gy for VMAT vs IMRT plans were (11.85±0.81 vs. 12.24±0.56, p=0.10) and (16.27±0.78 vs. 16.59±0.71, p=0.24), respectively. In VMAT, the average mean and maximum chiasm doses were 3% and 1% higher than in IMRT plans, respectively. For the left optic nerve, the average mean and maximum doses were 10% and 5% higher in VMAT than in IMRT plans, respectively. These values were 12% and 3% for the right optic nerve. The average percentage of dose gradient around the hippocampus in the 0–5mm and 5–10mm abutted regions for VMAT vs. IMRT were (4.42%±2.22% /mm vs. 3.95%±2.61% /mm, p=0.43) and (4.54%±1.50% /mm vs. 4.39%±1.28% /mm, p=0.73), respectively. Conclusion: VMAT plans can achieve higher hippocampus sparing with a faster dose fall-off than IMRT plans. Though statistically insignificant, VMAT offers better PTV coverage with slightly higher doses to OARs.

60 APPLIED LIFE SCIENCES↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗