Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Plasma facing components with capillary porous system and liquid metal coolant flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 °C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently, a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [A. Khodak and R. Maingi, Nucl. Mater. Energy 26, 100935 (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In the case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a fusion nuclear science facility [Kessel et al., Fusion Sci. Technol. 75, 886 (2019)]: 10 T toroidal field and 10 MW/m 2 peak incident heat flux. Finally, computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymmetry of the Ferroelectric Phase Transition in BaTiO 3

Symmetry changes during phase transformations fundamentally determine the behavior of thermodynamic systems, governing phenomena as diverse as water evaporation, fermion condensation, and epidemic spreading. Phase transitions are conventionally divided into two classes, and this classification is typically assumed to remain invariant upon reversing the transition. Here, an asymmetric phase transformation is uncovered in the ferroelectric–paraelectric transition of single-crystal BaTiO 3 , a model system for first-order transitions. Under slow temperature variation (≤0.1 °C min −1 ), thermodynamic, dielectric, and domain-structure measurements reveal that the ferroelectric-to-paraelectric transition exhibits latent heat, phase coexistence, and a discontinuous order parameter, while these signatures are absent upon cooling. Complementary phase-field simulations demonstrate similar behavior, attributing it to distinct elastic strain energy accumulation and release during heating and cooling. These findings reveal a first-order character upon heating but a second-order-like behavior upon cooling, challenging the conventional paradigm of symmetric phase-transition classification and suggesting new possibilities for ferroelectric-based energy storage.

Hershkovitz, Asaf [Technion-Israel Institute of Te↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Estimate of Gamma Dose Rates from Arrays of Fermi-1 Blanket Elements During the MEDE Process

The Enrico Fermi Atomic Power Plant Unit 1 (Fermi-1) was a sodium-cooled fast breeder reactor located in Monroe County, Michigan. The reactor was powered by a core of enriched uranium metal alloy driver fuel, which was enveloped by an axial and radial blanket material consisting of depleted uranium metal alloyed with 3 wt.% molybdenum. There are 406 axial and 559 radial irradiated sodium-bonded Fermi-1 blanket assemblies in storage at INL, totaling 34 metric tons of heavy metal. Disposal of the Fermi-1 blanket material directly into a geological repository is prohibited due to the reactive characteristic of its bond sodium. A melt drain evaporate (MEDE) process can effectively remove bond sodium from Fermi-1 blanket material. Consequently, planning is underway to apply a MEDE process to treat the 34 metric tons of heavy metal of irradiated Fermi-1 blanket material. Given the irradiated Fermi-1 blanket material’s relatively low power history and 50+ years of decay, it can be treated in a shielded glovebox. To assess the requisite shielding, the dose rates of the Fermi-1 blanket elements in various process configurations are needed. The method to perform the dose rate calculations is to first generate an average source term and associated photon source spectra for the Fermi-1 blanket material in SCALE and then use the associated photon spectra to calculate dose rates using MCNP6.2 in seven representative geometries. Dose rates in rem/h were calculated on contact (1 cm from outer geometry surface), 30 cm away from outer geometry surface, and 1 m from outer geometry surface at axial heights spanning the length of the blanket material within the geometry. The maximum average dose rate for the single Fermi-1 radial blanket element is ~0.60 rem/h, for the Fermi-1 radial blanket assembly ~1.10 rem/h, for the single Fermi-1 axial blanket element ~0.5 rem/h, for the Fermi-1 axial blanket assembly ~1.01 rem/h, for the MEDE can ~ 0.98 rem/h, for the Fermi Storage Canister ~ 0.83 rem/h, and for the MEDE cans in the DOE Standard Canister ~0.51 rem/h. Based on these maximum average values, the bounding dose rates are assumed to be 3× the average dose rates calculated for the axial blanket material and 7.6× the average dose rates calculated for the radial blanket material, based on the distribution of Fermi-1 blanket material assembly burnup.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microbubble dynamics and heat transfer in boiling droplets

Dissipating large heat fluxes from a surface is critically important in numerous industrial and natural applications. Boiling based spray cooling and surface texturing are two of the most promising methods being investigated to address this problem. Although our understanding on these topics has significantly improved over past decades, critical gaps remain in the knowledgebase stymieing the realization of their full potential. As an example, while bubble growth in pool boiling have been investigated in detail, comparatively little is known about how the bubbles evolve inside boiling drops. In the present work, we have investigated for the first time, the microbubble dynamics inside water droplets boiling on superhydrophilic textured substrates using high-speed X-ray phase contrast imaging (XRPCI). Our observations show that the transient bubble density variation follows similar characteristics irrespective of the texture spacing at a given surface temperature. For an example microstructure, we found that the number of discrete bubbles on the surface decreases as temperature is increased although their growth rate increases. Here, we observe that bubble growth is highly non-uniform during the lifetime of a drop on the surface. Initially, bubbles grow under diffusion-limited regime, but at later times they grow as ~t 1.45 due to combined effects of coalescence and evaporation. In some conditions, we found that bubbles shrink dramatically af- ter the initial growth spurt presumably due to severe quenching of the surface, and migration of bubbles on the surface. Using the bubble sizes, for the first time we analyzed the heat flux removed by a single bubble and also by all the bubbles at a given time. We find that the highest dissipation through latent- heat component (~600 W/cm 2 ) occurs just in the beginning and thereafter it decreases. We expect that our findings and the analysis would guide further work on the topic and will aid in the overarching goal of engineering surfaces that are more efficient in boiling heat transfer.

42 ENGINEERING↗

Sunlight-absorbing aerosol amplifies the seasonal cycle in low-cloud fraction over the southeast Atlantic

Abstract. The mean altitude of the smoke loading over the southeast Atlantic moves from the boundary layer in July to the free troposphere by October. This study details the month-by-month changes in cloud properties and the large-scale environment as a function of the biomass burning aerosol loading at Ascension Island (8∘ S, 14.5∘ W) from July to October, based on island measurements, satellite retrievals, and reanalysis. In July and August, the smoke loading predominantly varies within the boundary layer. During both months, the low-cloud fraction is less and is increasingly cumuliform when more smoke is present, with the exception of a late morning boundary layer deepening that encourages a short-lived cloud development. The meteorology varies little, suggesting aerosol–cloud interactions explain the cloudiness changes. September marks a transition month during which midlatitude disturbances can intrude into the Atlantic subtropics, constraining the free tropospheric aerosol closer to the African coast. Stronger boundary layer winds on cleaner days help deepen, dry, and cool much of the marine boundary layer compared to that on days with high smoke loadings, with stratocumulus reducing everywhere but at the northern deck edge. The September free troposphere is better mixed on smoky days compared to October. Longwave cooling rates, generated by a sharp water vapor gradient at the aerosol layer top, encourage a small-scale vertical mixing that could help maintain the well-mixed smoky September free troposphere. The October meteorology primarily varies as a function of the strength of the free tropospheric winds advecting aerosol offshore. The free tropospheric aerosol loading is less than in September, and the moisture variability is greater. Low-level clouds increase and are more stratiform in October when the smoke loadings are higher. The increased free tropospheric moisture can help sustain the clouds through a reduction in evaporative drying during cloud-top entrainment. Enhanced subsidence above the coastal upwelling region, increasing cloud droplet number concentrations, may further prolong cloud lifetime through microphysical interactions. Reduced subsidence underneath stronger free tropospheric winds at Ascension Island supports slightly higher cloud tops during smokier conditions. Overall, the monthly changes in the large-scale aerosol and moisture vertical structure act to amplify the seasonal cycle in low-cloud amount and morphology. This is climatically important, as cloudiness changes dominate changes in the top-of-atmosphere radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Onset of Nucleate Boiling Prediction in a Mini Channel with the Eulerian Multiphase Flow

The prediction of boiling incipience is a critical issue for a reactor. Vapor lock causes operating instability and undesirable temperature rise, especially for small channels. This study uses the Eulerian multiphase flow boiling model to predict the onset of nucleate boiling in a millimeter scale rectangular channel. Two wall boiling models, namely the RPI (Rensselaer Polytechnic Institute) and the non-equilibrium sub cooled model are applied. Computational fluid dynamics is employed for this study to investigate the impact of operating conditions like liquid flow rate, operating pressure, heat flux, velocity profile, turbulence model, and inlet liquid temperature. Here, the effect of fundamental boiling parameters on the surface wall temperature and vapor volume fraction is also studied. The parameters under consideration are the bubble departure diameter, bubble departure frequency, nucleate site density, quenching time period, and interface heat transfer coefficients. A series of CFD calculations is conducted by varying the considered variables systematically in a wide range of flow conditions covering laminar, transition, and turbulent flows. The sub-component heat fluxes like the liquid convective, the vapor convective, the evaporative, and the quenching terms are monitored to infer the boiling dynamics in the transition region from the single-phase flow to the nucleate boiling zone. It is found that the CFD approach to detecting the boiling incipience point agrees reasonably with available experimental data. However, its limitations, like inaccuracy for lower flow rates and early transition to boiling flow, are also noticed due to the nature of the considered RPI model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of biomass burning aerosols on radiation, clouds, and precipitation over the Amazon: relative importance of aerosol–cloud and aerosol–radiation interactions

Biomass burning (BB) aerosols can influence regional and global climate through interactions with radiation, clouds, and precipitation. Here, we investigate the impact of BB aerosols on the energy balance and hydrological cycle over the Amazon Basin during the dry season. We performed simulations with a fully coupled meteorology–chemistry model, the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem), for a range of different BB emission scenarios to explore and characterize nonlinear effects and individual contributions from aerosol–radiation interactions (ARIs) and aerosol–cloud interactions (ACIs). The ARIs of BB aerosols tend to suppress low-level liquid clouds by local warming and increased evaporation and to facilitate the formation of high-level ice clouds by enhancing updrafts and condensation at high altitudes. In contrast, the ACIs of BB aerosol particles tend to enhance the formation and lifetime of low-level liquid clouds by providing more cloud condensation nuclei (CCN) and to suppress the formation of high-level ice clouds by reducing updrafts and condensable water vapor at high altitudes (>8 km). For scenarios representing the lower and upper limits of BB emission estimates for recent years (2002–2016), we obtained total regional BB aerosol radiative forcings of –0.2 and 1.5 W m –2 , respectively, showing that the influence of BB aerosols on the regional energy balance can range from modest cooling to strong warming. We find that ACIs dominate at low BB emission rates and low aerosol optical depth (AOD), leading to an increased cloud liquid water path (LWP) and negative radiative forcing, whereas ARIs dominate at high BB emission rates and high AOD, leading to a reduction of LWP and positive radiative forcing. In all scenarios, BB aerosols led to a decrease in the frequency of occurrence and rate of precipitation, caused primarily by ACI effects at low aerosol loading and by ARI effects at high aerosol loading. The dependence of precipitation reduction on BB aerosol loading is greater in a strong convective regime than under weakly convective conditions. Overall, our results show that ACIs tend to saturate at high aerosol loading, whereas the strength of ARIs continues to increase and plays a more important role in highly polluted episodes and regions. This should hold not only for BB aerosols over the Amazon, but also for other light-absorbing aerosols such as fossil fuel combustion aerosols in industrialized and densely populated areas. The importance of ARIs at high aerosol loading highlights the need for accurately characterizing aerosol optical properties in the investigation of aerosol effects on clouds, precipitation, and climate.

54 ENVIRONMENTAL SCIENCES↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-extreme conditions at the Second Target Station

Three concepts for the application of multi-extreme conditions under in situ neutron scattering are described here. The first concept is a neutron diamond anvil cell made from a non-magnetic alloy. It is shrunk in size to fit existing magnets and future magnet designs and is designed for best pressure stability upon cooling. This will allow for maximum pressures above 10 GPa to be applied simultaneously with (steady-state) high magnetic field and (ultra-)low temperature. Additionally, an implementation of miniature coils for neutron diamond cells is presented for pulsed-field applications. The second concept presents a set-up for laser-heating a neutron diamond cell using a defocused CO 2 laser. Cell, anvil, and gasket stability will be achieved through stroboscopic measurements and maximum temperatures of 1500 K are anticipated at pressures to the megabar. The third concept presents a hybrid levitator to enable measurements of solids and liquids at temperatures in excess of 4000 K. This will be accomplished by a combination of bulk induction and surface laser heating and hyperbaric conditions to reduce evaporation rates. The potential for deployment of these multi-extreme environments within this first instrument suite of the Second Target Station is described with a special focus on VERDI, PIONEER, CENTAUR, and CHESS. Furthermore, considerations for deployment on future instruments, such as the one proposed as TITAN, are discussed. Overall, the development of these multi-extremes at the Second Target Station, but also beyond, will be highly advantageous for future experimentation and will give access to parameter space previously not possible for neutron scattering.

47 OTHER INSTRUMENTATION↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthesis of an Isostructural Series of 12-Coordinate Lanthanide Nitrate Hybrid Double Perovskites with Cubic Symmetry

In efforts to study the periodic chemical properties of the rare earth elements and their structural chemistry, a hybrid double perovskite phase A 2 B'BX 6 with the formula ((CH 3 ) 4 N) 2 KLn(NO 3 ) 6 (Ln = La–Lu, Y ex. Pm) was synthesized that crystallizes in the cubic space group, $Fm$$\bar{3}$$m$. This series was obtained via evaporative crystallization from a mixture of Ln(NO 3 ) 3 , KNO 3 , and (CH 3 ) 4 N·NO 3 in a 1:1:2 ratio from either H 2 O or 4.0 M HNO 3 . In this double perovskite structure, the B site containing the lanthanide ion is coordinated by six bidentate nitrate ligands, with the distal N$=$O oxygen atoms coordinating the potassium on the B' site in an octahedral six-coordinate environment. The two-remaining charge-compensating (CH 3 ) 4 N + cations occupy the interstitial voids in the lattice on the A site. This periodic series was characterized via single-crystal X-ray diffraction, powder X-ray diffraction, IR, and Raman spectroscopy. Emission spectra of the Eu complex indicate a phase transition to trigonal symmetry upon cooling. In conclusion, this series is unique as it represents a rare isostructural series spanning the entirety of the rare earth elements excluding promethium with homoleptic 12-coordinate rare earth metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗