Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow augmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Theoretical Investigations on the Efficiency and the Conditions for the Realization of Jet Engines

Contents: Preliminary notes on the efficiency of propulsion systems; Part I: Propulsion systems with direct axial reaction rockets and rockets with thrust augmentation; Part II: Helicoidal reaction propulsion systems; Appendix I: Steady flow of viscous gases; Appendix II: On the theory of viscous fluids in nozzles; and Appendix III: On the thrusts augmenters, and particularly of gas augmenters

Roy, Maurice↗

Aero-Heating of Shallow Cavities in Hypersonic Freestream Flow

The purpose of these experiments and analysis was to augment the heating database and tools used for assessment of impact-induced shallow-cavity damage to the thermal protection system of the Space Shuttle Orbiter. The effect of length and depth on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These rapid-response experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated immediately prior to the launch of STS-114, the initial flight in the Space Shuttle Return-To-Flight Program, and continued during the first week of the mission. Previously-designed and numerically-characterized blunted-nose baseline flat plates were used as the test surfaces. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process and the two-dimensional flow assumptions used for the data analysis. The experimental boundary layer state conditions were inferred using the measured heating distributions on a no-cavity test article. Two test plates were developed, each containing 4 equally-spaced spanwise-distributed cavities. The first test plate contained cavities with a constant length-to-depth ratio of 8 with design point depth-to-boundary-layer-thickness ratios of 0.1, 0.2, 0.35, and 0.5. The second test plate contained cavities with a constant design point depth-to-boundary-layer-thickness ratio of 0.35 with length-to-depth ratios of 8, 12, 16, and 20. Cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary results indicate that the floor-averaged Bump Factor (local heating rate nondimensionalized by upstream reference) at the tested conditions is approximately 0.3 with a standard deviation of 0.04 for laminar-in/laminar-out conditions when the cavity length-to-boundary-layer thickness is between 2.5 and 10 and for cavities in the depth-to-boundary-layer-thickness range of 0.3 to 0.8. Over this same range of conditions and parameters, preliminary results also indicate that the maximum Bump Factor on the cavity centerline falls between 2.0 and 2.75, as long as the cavity-exit conditions remain laminar. Cavities with length-to-boundary-layer-thickness ratio less than 2.5 can not be easily classified with this approach and require further analysis.

Everhart, Joel L.↗

Influence of simulated microgravity on the sympathetic response to exercise

Rats exposed to simulated conditions of microgravity exhibit reductions in aerobic exercise capacity that may be due to an impaired ability of the sympathetic nervous system (SNS) to mediate an increase in cardiac output and to redistribute blood flow. The purpose of this study was to quantify the sympathetic response to exercise in rats after exposure to 14 days of simulated microgravity or control conditions. To achieve this aim, rats were exposed to 14 days of head-down suspension (HDS) or cage control (CC) conditions. On day 14, norepinephrine (NE) synthesis was blocked with alpha-methyl-p-tyrosine, and the rate of NE depletion after synthesis blockade was used to estimate SNS activity in the left ventricle, spleen, and soleus muscle during treadmill exercise at 75% of maximal oxygen uptake. When compared with CC rats, the sympathetic response to exercise in HDS rats was characterized by a lower rate of NE depletion in the left ventricle (-82%) and spleen (-42%). The rate of NE depletion in the soleus muscle was 47% higher. These differences could contribute to the decrement in aerobic capacity of HDS rats by impairing their ability to augment cardiac output and to redirect blood flow to actively contracting skeletal muscle during exercise.

NASA Discipline Cardiopulmonary↗

Simulation of Sweep-Jet Flow Control, Single Jet and Full Vertical Tail

This work is a simulation technology demonstrator, of sweep jet flow control used to suppress boundary layer separation and increase the maximum achievable load coefficients. A sweep jet is a discrete Coanda jet that oscillates in the plane parallel to an aerodynamic surface. It injects mass and momentum in the approximate streamwise direction. It also generates turbulent eddies at the oscillation frequency, which are typically large relative to the scales of boundary layer turbulence, and which augment mixing across the boundary layer to attack flow separation. Simulations of a fluidic oscillator, the sweep jet emerging from a nozzle downstream of the oscillator, and an array of sweep jets which suppresses boundary layer separation are performed. Simulation results are compared to data from a dedicated validation experiment of a single oscillator and its sweep jet, and from a wind tunnel test of a full-scale Boeing 757 vertical tail augmented with an array of sweep jets. A critical step in the work is the development of realistic time-dependent sweep jet inflow boundary conditions, derived from the results of the single-oscillator simulations, which create the sweep jets in the full-tail simulations. Simulations were performed using the computational fluid dynamics (CFD) solver Overow, with high-order spatial discretization and a range of turbulence modeling. Good results were obtained for all flows simulated, when suitable turbulence modeling was used.

flow control↗

Extending High-Level Synthesis with AI/ML Methods

Artificial Intelligence (AI) and Machine Learning (ML) methods provide significant opportunities of improving quality of results when performing high-level synthesis (HLS). For example, they can be used to model and predict metrics of the final design (e.g., area, considering aspects such as interconnect overhead for different device technologies), facilitating exploration when searching for the best design trade-offs. They can also enable identifying hidden correlations across the various phases of the synthesis and the various optimizations performed, identifying the most effective pipelines. Finally, in more general terms, bio-inspired heuristic algorithms can improve the design space exploration for the synthesis process in terms of time and quality of the result. This paper discusses opportunities and challenges to augment HLS with AI/ML using as example flow the SODA Synthesizer, an open-source hardware generation toolchain which includes SODA-OPT, a hardware/software partitioning and pre-optimization tool developed with the MLIR framework, and PandA-Bambu, a state-of-the art HLS tool. SODA interfaces with OpenROAD to provide a complete end-to-end toolchain.

artificial intelligence↗

Calculation of the longitudinal aerodynamic characteristics of STOL aircraft with externally-blown jet-augmented flaps

A theoretical investigation was made to develop methods for predicting the longitudinal aerodynamic characteristics of externally-blown, jet-augmented wing-flap combinations. A potential flow analysis was used to develop two models: a wing-flap lifting surface model and a high-bypass-ratio turbofan engine wake model. Use of these two models in sequence provides for calculation of the wing-flap load distribution including the influence of the engine wake. The method can accommodate multiple engines per wing panel and part-span flaps but is limited to the case where the flow and geometry of the configuration are symmetric about a vertical plane containing the wing root chord. Comparisons of predicted and measured lift and pitching moment on unswept and swept wings with one and two engines per panel and with various flap deflection angles indicate satisfactory prediction of lift and moment for flap deflections up to 30 to 40 degrees. At higher flap angles with and without power, the method begins to overpredict lift, due probably to the appearance of flow separation on the flaps.

Dillenius, M. F. E.↗

Vortices induced in a stagnation region by wakes - Their incipient formation and effects on heat transfer from cylinders

Horseshoe-like vortices, induced by wakes in the stagnation region of bluff bodies, are proposed as an efficient mechanism for augmentation of convective heat transfer. The vortex 'flow module' induced by single or multiple wakes, which had not been observed previously, was first documented and the resulting flow field was studied using various visualization techniques and hot-wire anemometry. In an attempt to understand the driving force behind this flow module, the conditions at which incipient formation of the vortices occurs were investigated. Existence of such a threshold is essential and was hitherto an open question in analytical studies of stability of flow in stagnation region. Finally, effects of the flow module on heat transfer from a cylinder were measured.

Nagib, H. M.↗

Dish stirling solar receiver combustor test program

The operational and energy transfer characteristics of the Dish Stirling Solar Receiver (DSSR) combustor/heat exchanger system was evaluated. The DSSR is designed to operate with fossil fuel augmentation utilizing a swirl combustor and cross flow heat exchanger consisting of a single row of 4 closely spaced tubes that are curved into a conical shape. The performance of the combustor/heat exchanger system without a Stirling engine was studied over a range of operating conditions and output levels using water as the working fluid. Results show that the combustor may be started under cold conditions, controlled safety, and operated at a constant air/fuel ratio (10 percent excess air) over the required range of firing rates. Furthermore, nondimensional heat transfer coefficients based on total heat transfer are plotted versus Reynolds number and compared with literature data taken for single rows of closely spaced tubes perpendicular to cross flow. The data show enhanced heat transfer for the present geometry and test conditions. Analysis of the results shows that the present system meets specified thermal requirements, thus verifying the feasibility of the DSSR combustor design for final prototype fabrication.

Bankston, C. P.↗

A nonoscillatory shock capturing scheme using flux limited dissipation

A method for modifying the third order dissipative terms by the introduction of flux limiters is proposed. The first order dissipative terms can then be eliminated entirely, and in the case of a scalar conservation law the scheme is converted into a total variation diminishing scheme provided that an appropriate value is chosen for the dissipative coefficient. Particular attention is given to: (1) the treatment of the scalar conservation law; (2) the treatment of the Euler equations for inviscid compressible flow; (3) the boundary conditions; and (4) multistage time stepping and multigrid schemes. Numerical results for transonic flows suggest that a central difference scheme augmented by flux limited dissipative terms can lead to an effective nonoscillatory shock capturing method.

Jameson, A.↗

Calculation of aerodynamic characteristics of airplane configurations at high angles of attack

Calculation of longitudinal and lateral directional aerodynamic characteristics of airplanes by the VORSTAB code is examined. The numerical predictions are based on the potential flow theory with corrections of high angle of attack phenomena; namely, vortex flow and boundary layer separation effects. To account for the vortex flow effect, vortex lift, vortex action point, augmented vortex lift and vortex breakdown effect through the method of suction analogy are included. The effect of boundary layer separation is obtained by matching the nonlinear section data with the three dimensional lift characteristics iteratively. Through correlation with results for nine fighter configurations, it is concluded that reasonably accurate prediction of longitudinal and static lateral directional aerodynamics can be obtained with the VORSTAB code up to an angle of attack at which wake interference and forebody vortex effect are not important. Possible reasons for discrepancy at higher angles of attack are discussed.

Tseng, J. B.↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence↗

Energy Efficient Engine exhaust mixer model technology report addendum; phase 3 test program

The Phase 3 exhaust mixer test program was conducted to explore the trends established during previous Phases 1 and 2. Combinations of mixer design parameters were tested. Phase 3 testing showed that the best performance achievable within tailpipe length and diameter constraints is 2.55 percent better than an optimized separate flow base line. A reduced penetration design achieved about the same overall performance level at a substantially lower level of excess pressure loss but with a small reduction in mixing. To improve reliability of the data, the hot and cold flow thrust coefficient analysis used in Phases 1 and 2 was augmented by calculating percent mixing from traverse data. Relative change in percent mixing between configurations was determined from thrust and flow coefficient increments. The calculation procedure developed was found to be a useful tool in assessing mixer performance. Detailed flow field data were obtained to facilitate calibration of computer codes.

Larkin, M. J.↗

Development of an Additive Manufactured Cryogenic TVS Augmented Injector

Cryogenic fluid transfer is critical in ground and space systems. Transfer typically requires venting a receiver vessel during the chill and fill process to maintain a pressure favorable to fluid flow. Venting in space is problematic due to low-gravity where fluid position is indeterminate; possibly allowing fluid to flow out the vent. To control receiver tank venting the vented chill/no-vent fill methodology is attractive. An additively manufactured Injector coupled with a Thermodynamic Venting System (TVS) augmentation can enable the vented chill/no-vent fill approach with simplified operations. The TVS augmented injector includes an internal heat exchanger, fluid injector spray head, and external surface condensation heat exchange; combined with integrated flow paths in one part. Operations using the injector allow the tank vent to be closed very early in the transfer and not reopened. The TVS circuit eliminates the potential for stalled fill by maintaining cooling flow on the injector and condenser elements, reducing tank pressure. The injector can also be employed for long-term cryo fluid storage as a means of controlling tank pressure if integrated with a recirculation pump. A cryo-cooler can be used in place of/or augmenting the TVS flow circuit for a zero loss pressure control system. The Injector was developed using the principles of design for additive manufacture and printed as one part, resulting in part count reduction, improved reproducibility, shorter lead times, and reduced cost. The TVS augmented injector is compact and highly adaptable simplifying its integration. A key benefit is that this methodology enables simplified operations in reaching 100% fill conditions.

Omar Mireles↗

Modified ICED-ALE method for astrogeophysical plasma flows

The Implicit-Continuous-Eulerian-Difference Mesh-Arbitrary-Lagrangian-Eulerian (ICED-ALE) algorithm of Brackbill and Pracht (1973) is modified for the study of astrophysical plasma flows in which dynamical effects are important. In the present study the general-energy-conservation law is directly applied to the iteration process, with the total (kinetic-, specific-internal-, and magnetic-) energy density being obtained implicitly at the end of the process. An example is computed in which the convergence speed of the latter method is substantially faster than that of the former. The initializing calculation, or explicit phase, in which the electric current density, magnetic diffusion of field, energy augmentation, and zero-order approximation of the flow velocity are given, is described. Consideration is given to the iteration process, or implicit phase, from which the exact Lagrangian solution for energy density, velocity, and a magnetic field is obtained.

Wu, S. T.↗

Modifications to the streamtube curvature program. Volume 1: Program modifications and user's manual

The improvements which have been incorporated in the Streamtube Curvature Program to enhance both its computational and diagnostic capabilities are described. Detailed descriptions are given of the revisions incorporated to more reliably handle the jet stream-external flow interaction at trailing edges. Also presented are the augmented boundary layer procedures and a variety of other program changes relating to program diagnostics and extended solution capabilities. An updated User's Manual, that includes information on the computer program operation, usage, and logical structure, is presented. User documentation includes an outline of the general logical flow of the program and detailed instructions for program usage and operation. From the standpoint of the programmer, the overlay structure is described. The input data, output formats, and diagnostic printouts are covered in detail and illustrated with three typical test cases.

Ferguson, D. R.↗