Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow lines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Modeling of Lead-210 Data Documents Benefits in Proactively Understanding TENORM Deposition - 18515

Radioactive decay of naturally occurring Radon-222 present in just-produced natural gas can lead to deposition of its radiogenic daughter, Lead-210, and subsequent radiogenic progeny within natural gas handling, treatment, and distribution facilities. Worker safety issues and disposal challenges arise when these accumulate to radiologically problematic activity levels. This is due to the 22.3-year half-life of Lead-210, allowing for multi-decade period of accumulation to occur and to persist, even after facility operations have ceased. Due to the far shorter half-lives of Lead-210 radiogenic progeny, especially that of Polonium-210, secular equilibrium within the Lead-210-Bismuth-210-Polonium-210 decay chain is quickly approached during facility operations and achieved after facility operations end. Lead-210 that accumulates in pipe scale can complicate any subsequent intrusive facility modifications, such as disassembly and dismantlement, potentially exposing workers to adverse radioactivity and impeding recycling and/or disposal of radiologically impacted equipment or other material. Experience has shown it is not strictly the presence of Lead-210 that is problematic but rather its 'unexpected' presence when this Technologically Enhanced Naturally Occurring Radioactive Material (TENORM) is discovered during intrusive work not incorporating radiological health and safety and material handling plans. Conversely, when implementing a program that proactively considers the potential for Lead-210, this form of TENORM simply becomes another 'special waste' that can be safely, efficiently, and effectively addressed during a decommissioning effort, without associated adverse worker exposures, project cost over-runs, and schedule delays. This paper will discuss how proactive radioactive scanning quickly and safely identified Lead-210 and its radiogenic progeny within a natural gas sweetening and compressor station located in northern Montana, a portion of which was undergoing decommissioning, aiding in safe and compliant material handling and recycling. The location of this operation necessitated that the decommissioning program be completed on schedule to prevent weather-related impacts due to the onset of adverse winter conditions. Further, the radioactive data acquired during this project will be shown to provide important insight into historic behavior of Lead-210 in terms of its disposition and its more recent decay. From these data, it became possible to back-model the average activity of Radon-222 within the natural gas being processed during the life of the operation, how the estimated Radon-222 activity within the processed natural gas conformed to measured Radon-222 at various other natural gas fields, and how this information can be leveraged in developing safe and successful plans for future intrusive work at this and companion site operations. This presentation will also note the apparent preferential accumulation of Lead-210 within both rubber-based materials, such as gaskets and seals, and grease-based products found within natural gas flow lines. Thoughts regarding processes that may lead to this finding will be explored. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRITIUM AGING EFFECTS ON THE FRACTURE TOUGHNESS PROPERTIES OF STAINLESS STEEL BASE METAL AND WELDS

Tritium reservoirs are constructed from welded stainless steel forgings. While these steels are highly resistant to the embrittling effects of hydrogen isotopes and helium from tritium decay; they are not immune. Tritium embrittlement is an enhanced form of hydrogen embrittlement because of the presence of helium-3 from tritium decay which nucleates as nanometer-sized bubbles on dislocations, grain boundaries, and other microstructural defects. Steels with decay helium bubble microstructures are hardened and less able to deform plastically and become more susceptible to embrittlement by hydrogen and its isotopes. Ductility, elongation-to-failure, and fracture toughness are reduced by exposures to tritium and the reductions increase with time as helium-3 builds into the material from tritium permeation and radioactive decay. Material and forging specifications have been developed for optimal material compatibility with tritium. These specifications cover composition, mechanical properties, and select microstructural characteristics like grain size, flow-line orientation, inclusion content, and ferrite distribution. For many years, the forming process of choice for reservoir manufacturing was high-energy-rate forging (HERF), principally because the DOE forging facility owned only HERF hammers. Today, some reservoir forgings are being made that use a conventional, more common process known as press forging (PF or CF). One of the chief differences between the two forging processes is strain rate: Conventional hydraulic or mechanical forging presses deform the metal at 4-8 ft/s, about ten-fold slower than the HERF process. The material specifications continue to provide successful stockpile performance by ensuring that the two forging processes produce similar reservoir microstructures. While long-term life storage tests have demonstrated the general tritium compatibility of tritium reservoirs, fracture-toughness properties of both conventionally forged and high-energy-rate forged are needed for designing and establishing longer tritium-reservoir lifetimes, ranking materials, and, potentially, for qualifying new forging vendors or processes. Measurements on the effects of tritium and decay helium on the fracture toughness properties of CF stainless steels having similar composition, grain size, and mechanical properties to previously studied HERF steels are needed and have not been conducted until now. The compatibility of stainless steel welds with tritium represents another concern for long-term reservoir performance. Weldments have not been well-characterized with respect to tritium embrittlement, although a recent study was completed on the effect of tritium and decay helium on the fracture toughness properties of Type 304L weldments. This study expands the characterization of weldments through measurements of tritium and decay helium effects on the fracture toughness properties of Type 21-6-9 stainless steel. The purpose of this study was to measure and compare the fracture toughness properties of Type 21-6-9 stainless steel for conventional forgings and weldments in the non-charged, hydrogen-charged and tritium-charged-and-aged conditions.

08 HYDROGEN↗

Enhanced Line Integral Convolution with Flow Feature Detection

The Line Integral Convolution (LIC) method, which blurs white noise textures along a vector field, is an effective way to visualize overall flow patterns in a 2D domain. The method produces a flow texture image based on the input velocity field defined in the domain. Because of the nature of the algorithm, the texture image tends to be blurry. This sometimes makes it difficult to identify boundaries where flow separation and reattachments occur. We present techniques to enhance LIC texture images and use colored texture images to highlight flow separation and reattachment boundaries. Our techniques have been applied to several flow fields defined in 3D curvilinear multi-block grids and scientists have found the results to be very useful.

Lane, David↗

The solar wind flow along the subsolar line in the magnetic barrier and reconnection at the magnetopause

The magnetic barrier is a significant fraction of the magnetosheath region where magnetic forces react back on the plasma flow. We use a magnetohydrodynamic approach to calculate the solar wind flow around the magnetosphere. The use of so-called frozen-in coordinates, where the flow lines and the magnetic field are coordinate axes, is found to be most appropriate. Numerical solutions are presented for the problem of the flow around a blunt body. The results near the magnetopause are used as input parameters for a model of the reconnection of magnetic field lines based on shock-type structures.

Erkaev, N. V.↗

Shuttle Main Propulsion System LH2 Feed Line and Inducer Simulations

This viewgraph presentation includes simulations of the unsteady flow field in the LH2 feed line, flow line, flow liner, backing cavity and inducer of Shuttle engine #1. It also evaluates aerodynamic forcing functions which may contribute to the formation of the cracks observed on the flow liner slots. The presentation lists the numerical methods used, and profiles a benchmark test case.

Daniel Dorney↗

Real-time, In-line Assessment of Flow Performance for Compressible and Anisotropic Bulk Solids

Feeding and handling problems have been recognized as a major contributor to low production of renewable cellulosic ethanol in the US, which achieved only 7% of nameplate capacity in 2016. Current methods that assess material feeding and handling properties require multiple hours to complete, making them ill-suited for quality assurance and control (QA/QC) in production environments. This talk presents a method, based upon a custom hopper with adaptable geometry, to assess feeding and handling behavior of materials in a production or receiving line in real-time, so that those properties can be used to either sort material or adjust preprocessing conditions to ensure that incoming material meet feeding and handling specifications. Flow properties are determined by continually adjusting the size of the outlet in a plane-flow hopper to maintain a constant fill level in the hopper. The angle of the hopper walls can also be adjusted to tune the geometry to different materials. Tests conducted at approximately 1,000 lbs per hour indicate that this method readily assesses the flow performance differences of corn stover and pine wood due to changes in particle size from 3 to 13 mm and due to changes in moisture content from 10 to 20%. Comparison of this method with shear tests using an automated Schulze ring shear indicate that this method is more sensitive for determining differences in flowability performance than traditional shear tests for corn stover and pine wood. Test results, including wall pressure measurements, are compared to simulations and indicate that this method shows promise for in-line quantitative estimation of the flow properties of compressible and anisotropic materials, including bulk density, cohesion, and internal angle of friction.

09 BIOMASS FUELS↗

Comparison of hydrodynamic and semi-kinetic treatments for plasma flow along closed field lines

Hydrodynamic and semi-kinetic treatments of plasma flow along closed geomagnetic field lines are compared. The hydrodynamic treatment is based on a simplified 16-moment set of transport equations as the equations for the heat flows are not solved; the heat flows are treated heuristically. The semi-kinetic treatment is based on a particle code. The comparison deals with the distributions of the plasma density, flow velocity, and parallel and perpendicular temperatures as obtained from the two treatments during the various stages of the flow. In the kinetic treatment, the appropriate boundary condition is the prescription of the velocity distribution functions for the particles entering the flux tubes at the ionospheric boundaries; those particles leaving the system are determined by the processes occurring in the flux tube. The prescribed distributions are half-Maxwellian with temperature T(sub 0) and density n(sub 0). In the hydrodynamic model, the prescribed boundary conditions are on density (n(sub 0)), flow velocity (V(sub 0)) and temperature (T(sub 0). It was found that results from the hydrodynamic treatment critically depend on V(sub 0); for early stages of the flow this treatment yields results in good agreement with those from the kinetic treatment, when V(sub 0) = square root of (kT(sub 0)/2 (pi)m), which is the average velocity of particles moving in a given direction for a Maxwellian distribution. During this early stage, the flows developing form the conjugate ionospheres show some distinct transitions. For the first hour or so, the flows are highly supersonic and penetrate deep into the opposite hemispheres, and both hydrodynamics and kinetic treatments yield almost similar features. It is found that during this period heatflow effects are negligibly small. When a flow penetrates deep into the opposite hemisphere, the kinetic treatment predicts reflection and setting up of counterstreaming. In contrast, the hydrodynamic treatment yields a shock in the flow. The reasons for this difference in the two treatments is discussed, showing that in view of the relatively warm ions, the coupling of ion beams and the consequent shock formation in the offequatorial region are not likely due to the enhancements in the beam temperatures. The counterstreaming in the kinetic treatment and the shock in the hydrodynamic treatment first advance upward to the equator and then downward to the ionospheric boundary from where the flow originated. The transit time for this advancement is found to be about 1 hour for the respective models. After 2 hours or so, both models predict that the flows from the ionospheric boundaries are generally subsonic with respect to the local ion-sound speed. At late stages of the flow, when a substantial fraction of ions entering the flux tube begin to return back in the kinetic treatment, the hydrodynamic treatment with the boundary condition V(sub 0) = square root of (kT(sub 0)/2(pi)m) yields an over-refilling, and the choice of V(sub 0) becomes uncertain.

Singh, Nagendra↗

The application of finite element techniques to acoustic transmission in lined ducts with flow

The finite element method (FEM) is used to analyze the propagation of sound in two-dimensional nonuniform ducts carrying a compressible subsonic mean flow. Galerkin and residual least squares (RLS) methods with natural and forced boundary conditions are considered. The accuracy of FEM results for the eigenvalue and transmission problems is assessed by comparison with alternative numerical schemes for nonuniform ducts. The results presented and those from associated investigations indicate that modal coupling is a significant feature of the acoustic field, especially at high Mach numbers. A multimodal model therefore appears to be essential if any reliable conclusions are to be drawn in the context of turbofan inlet regions. Improvements to the eigenvalue scheme following the implementation of higher-order Hermitian elements indicate a similar modification for the transmission problem.

Astley, R. J.↗